• 제목/요약/키워드: oneM2M standards

검색결과 147건 처리시간 0.022초

An Analysis of Thermal Comforts for Pedestrians by WBGT Measurement on the Urban Street Greens (도심 가로 녹음의 습구흑구온도(WBGT) 측정을 통한 보행자 열쾌적성 효과 분석)

  • Ahn, Tong-Mahn;Lee, Jae-Won;Kim, Bo-Ram;Yoon, Ho-Seon;Son, Seung-Woo;Choi, Yoo;Lee, Na-Rae;Lee, Ji-Young;Kim, Hae-Ryung
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • 제41권3호
    • /
    • pp.22-30
    • /
    • 2013
  • This study aims to measure the thermal comfort effects of urban street trees. As the usual dry bulb air temperature does not indicate properly how the average pedestrian feels the heat of a typical summer day under the strong sunshine, we adopted the Wet Bulb Globe Temperature(WBGT). WBGT involves black globe temperature to measure the direct radiation of sun beams on our bodies, for example our heads. We measured temperatures on very sunny and hot summer days, August 3, 4, and 7, 2012, on the urban streets of Seoul, Korea. Wet bulb, globe, and dry bulb temperatures were measured under direct sunlight from 1 O'clock to 5 O'clock pm. Globe and dry bulb temperatures were measured under street tree shades nearby during the same hours. Then the WBGTs were calculated with the formulae, one for sunny outdoor spaces, and the other for shaded outdoor spaces or indoor. The results are compared with the Korean Standards Association(KS A ISO 7243). The major findings were: 1) On very sunny and hot summer days in Seoul, street tree shades lower the WBGT about 1 to 4 degrees, 2) during the hours of 3 and 4 O'clock in the afternoon, the WBGT under the tree shades are about 3 to 4 degrees lower compared to those under sunshines(approx. 29 to 32 degrees respectively), 3) This difference makes a major thermal comfort for urban pedestrians because senior citizens or weak persons are recommended to move indoor, and even healthy people are recommended stop outdoor sports and take rests in the shades when WBGT is about 32. On the other hand, if the WBGT is around 29, or 3 degrees lower, slower walking, light works or sports are allowable, 4) On site questionnaire survey confirms the thermal comforts under the tree shades, and we even could not get survey subjects on the sunny parts of the sidewalks, 5) We strongly recommend change of guidelines for urban street trees from "one row of street trees on 6m~8m intervals" to "street trees to make continuous shades".

Usefulness of Minimally Invasive Radio-Guided Parathyroidectomy in Patients with Prior Central Neck Exploration (중앙 경부 수술의 과거력이 있는 환자에서의 방사능 유도 최소 침습 부갑상선 절제술의 유용성)

  • Lee, Sung-Hwan;Kim, Bup-Woo;Kim, Kuk-Jin;Lee, Yong-Sang;Jeong, Jong-Ju;Nam, Kee-Hyun;Chung, Woong-Youn;Chang, Hang-Seok;Park, Cheong-Soo
    • Korean Journal of Head & Neck Oncology
    • /
    • 제25권2호
    • /
    • pp.138-142
    • /
    • 2009
  • Introduction : Although bilateral exploration has been thought to be the standard therapeutic modality for primary hyperparathyroidism(pHPT) due to the admirable cure rate, questions have remained as to whether bilateral neck exploration for all patients with pHPT is needed because 80-85% of patients with pHPT have a single parathyroid adenoma. If the diseased parathyroid can be determined preoperatively, a directed and minimal operation is appropriate using the recent innovations of preoperative diagnosis and operation techniques for parathyroid diseases, the radio-guided parathyroid surgery(RGPS) is one of the standards. In especial, RGPS has been reported beneficial in special circumstances, such as in recurrent disease, ectopic parathyroid, and in mediastinal parathyroid. It can be also useful for the parathyroid disease in previously explored or irradiated neck. Material and Methods : We experienced 2 cases of pHPT successfully treated by RGPS in who previously underwent extensive neck dissection and concomitant external or internal radiotherapy. We adopted and modified the technique described by Dr. James Norman at the University of South Florida-the minimally invasive parathyroidectomy using intraoperative nuclear mapping with 99mTc-sestamibi scanning and radioactivity detection probe. Results : We acquired the successful results for these patients. Conclusion : RGPS is thought to be the alternative technique for the patients with prior central neck exploration and irradiation.

Calculation of Concrete Shielding Wall Thickness for 450 kVp X-ray Tube with MCNP Simulation and Result Comparison with Half Value Layer Method Calculation (MCNP 시뮬레이션을 통한 450 kVp 엑스레이 튜브의 콘크리트 차폐벽 두께 계산 및 반가층 방법을 이용한 계산과의 결과 비교)

  • Lee, Sangheon;Hur, SamSurk;Lee, Eunjoong;Kim, Chankyu;Cho, Gyu-seong
    • Journal of Radiation Industry
    • /
    • 제10권1호
    • /
    • pp.29-35
    • /
    • 2016
  • Radiation generating devices must be properly shielded for their safe application. Although institutes such as US National Bureau of Standards and National Council on Radiation Protection and Measurements (NCRP) have provided guidelines for shielding X-ray tube of various purposes, industry people tend to rely on 'Half Value Layer (HVL) method' which requires relatively simple calculation compared to the case of those guidelines. The method is based on the fact that the intensity, dose, and air kerma of narrow beam incident on shielding wall decreases by about half as the beam penetrates the HVL thickness of the wall. One can adjust shielding wall thickness to satisfy outside wall dose or air kerma requirements with this calculation. However, this may not always be the case because 1) The strict definition of HVL deals with only Intensity, 2) The situation is different when the beam is not 'narrow'; the beam quality inside the wall is distorted and related changes on outside wall dose or air kerma such as buildup effect occurs. Therefore, sometimes more careful research should be done in order to verify the effect of shielding specific radiation generating device. High energy X-ray tubes which is operated at the voltage above 400 kV that are used for 'heavy' nondestructive inspection is an example. People have less experience in running and shielding such device than in the case of widely-used low energy X-ray tubes operated at the voltage below 300 kV. In this study, Air Kerma value per week, outside concrete shielding wall of various thickness surrounding 450 kVp X-ray tube were calculated using MCNP simulation with the aid of Geometry Splitting method which is a famous Variance Reduction technique. The comparison between simulated result, HVL method result, and NCRP Report 147 safety goal $0.02mGy\;wk^{-1}$ on Air Kerma for the place where the public are free to pass showed that concrete wall of thickness 80 cm is needed to achieve the safety goal. Essentially same result was obtained from the application of HVL method except that it suggest the need of additional 5 cm concrete wall thickness. Therefore, employing the result from HVL method calculation as an conservative upper limit of concrete shielding wall thickness was found to be useful; It would be easy, economic, and reasonable way to set shielding wall thickness.

Validation of a physical activity classification table in Korean adults and elderly using a doubly labeled water method (한국 성인과 노인을 대상으로 이중표식수법을 이용한 신체활동분류표 타당도 평가)

  • Hye-Ji Han ;Ha-Yeon Jun;Jonghoon Park;Kazuko Ishikawa-Takata;Eun-Kyung Kim
    • Journal of Nutrition and Health
    • /
    • 제56권4호
    • /
    • pp.391-403
    • /
    • 2023
  • Purpose: This study evaluated the validity of a physical activity classification table (PACT) based on total energy expenditure (TEE) and physical activity level (PAL) measured using the doubly labeled water (DLW) method in Korean adults and the elderly. Methods: A total of 141 (male 70, female 71) adults and elderly were included. The reference standards TEEDLW, PALDLW were measured over a 14-day period using DLW. A 24-hour physical activity diary was kept for three days (two days during the week and one day on the weekend). PALPACT was calculated by classifying the activity type and intensity using the PACT. PALPACT was multiplied by resting energy expenditure measured by indirect calorimetry to estimate TEEPACT. Results: The mean age of the study participants was 50.5 ± 18.8 years, and the mean body mass index was 23.4 ± 3.3 kg/m2. A comparison of TEEDLW and TEEPACT by sex and age showed no significant differences. The bias, the difference between TEEDLW and TEEPACT, was male 17.3 kcal/day and female -4.5 kcal/day. The percentage of accurate predictions (values within ± 10% of the TEEDLW) of TEEPACT was 58.6% in males and 54.9% in females, with the highest prediction values in the age group 40-64 years (70.9%) in males and over 65 years (73.9%) in females. The spearman correlation coefficient (r) between TEEPACT and TEEDLW was 0.769, indicating a significant positive correlation (p < 0.001). Conclusion: In this study, the use of a new PACT for calculating TEE and PAL was evaluated as valid. A web version of the software program and a smartphone application need to be developed using PACT to make it easier to apply for research purposes.

Corrections on CH4 Fluxes Measured in a Rice Paddy by Eddy Covariance Method with an Open-path Wavelength Modulation Spectroscopy (개회로 파장 변조 분광법과 에디 공분산 방법으로 논에서 관측된 CH4 플럭스 자료의 보정)

  • Kang, Namgoo;Yun, Juyeol;Talucder, M.S.A.;Moon, Minkyu;Kang, Minseok;Shim, Kyo-Moon;Kim, Joon
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • 제17권1호
    • /
    • pp.15-24
    • /
    • 2015
  • $CH_4$ is a trace gas and one of the key greenhouse gases, which requires continuous and systematic monitoring. The application of eddy covariance technique for $CH_4$ flux measurement requires a fast-response, laser-based spectroscopy. The eddy covariance measurements have been used to monitor $CO_2$ fluxes and their data processing procedures have been standardized and well documented. However, such processes for $CH_4$ fluxes are still lacking. In this note, we report the first measurement of $CH_4$ flux in a rice paddy by employing the eddy covariance technique with a recently commercialized wavelength modulation spectroscopy. $CH_4$ fluxes were measured for five consecutive days before and after the rice transplanting at the Gimje flux monitoring site in 2012. The commercially available $EddyPro^{TM}$ program was used to process these data, following the KoFlux protocol for data-processing. In this process, we quantified and documented the effects of three key corrections: (1) frequency response correction, (2) air density correction, and (3) spectroscopic correction. The effects of these corrections were different between daytime and nighttime, and their magnitudes were greater with larger $CH_4$ fluxes. Overall, the magnitude of $CH_4$ flux increased on average by 20-25% after the corrections. The National Center for AgroMeteorology (www.ncam.kr) will soon release an updated KoFlux program to public users, which includes the spectroscopic correction and the gap-filling of $CH_4$ flux.

A Study on the Water Quality of Reservoir Tank in the Building Complex on Jeonnam Area (대형건축물 저수조의 수질실태 및 개선방안에 관한 연구)

  • Lee, J.H.;Lee, H.H.;Kim, H.B.;Ahn, G.W.;Park, K.N.;Kim, Y.K.;Bae, J.S.;Mun, H.;Park, C.U.;Oh, E.H.;Park, S.I.;Seo, Y.G.
    • Journal of environmental and Sanitary engineering
    • /
    • 제15권4호
    • /
    • pp.59-77
    • /
    • 2000
  • This study was carried out to investigate on several factors, which contaminative the water quality through the water pipe during feeding water, in 42 largescaled apart-ments(total 84 cases) and assayed the Volatile Organic Compounds(VOCs) and concen-tration of heavy metals that inflow and outflow in reservior water in Jeonnam area(Mokpo, Suncheon, Yeosu) from January 1999 to December 1999. The results obtained were summarized as follows ; 1. The quality of the water pipe composition in the order of frequency in the quality of water pipes were Copper(45.2%)> Zinc(38.9%)> Stainless steel(9.5%)> PVC(4.8%)> PM(2.4%) in observing 42 sites. All of the drain pipes were used the cast iron quality. 2. The result of certification curve from 12 items(17kind) of VOCs was $1.0-4.0{\mu{g}}/{\ell}$ range, a coefficient of correlation was shown 0.99 over. A MDL of each substance range was within $0.1-1.0{\mu{g}}/{\ell}$. 3. The result of the assay, 5 kinds(Viny chloride, Dichloromethane, Ethylbenzene, M,P-xylene, Styrene) of the VOCs of 14 kinds was not detected and the other items were detected slightly. The detection rate of one item and over in total VOCs samples, were 25.9% in inflow and 27.9% in outflow. And frequency of detect in inflow/outflow of THM(Chloroform, Bromodichloro-methane, Dibromochloromethane, Bromoform) were shown higher than 94.1%, 97.0% each stages. It comes to the conclusion that all of the samples were reason able for drinking water standards. 4. The coefficient of correlation were reasonable, it shown 0.999 over in $0.1-1.0{\mu{g}}/{\ell}$ of a measuring range conditions of 4kinds in organic substance(Zn, Cu, Fe, Mn). 5. The results were showed suitability in 78 cases(92.9%) and unsuitability in 6 cases (7.1%), in 84 cases of in organic substances. Compare to inflow stage, mean concentrations of heavy metal, were increased slightly in Zn, Cu, Fe except Mn than outflow stage. The result of the mean concentration in organic substance inflow and outflow in the apartment water tank using Pair-compared T-test, in 95% reliance index, were $0.179mg/{\ell}(0.151-0.307mg/{\ell})$ in Zinc, $0.136mg/{\ell}(0.113-0.230mg/{\ell})$ in Copper, $0.052mg/{\ell}(0.048-0.098mg/{\ell})$ in Fe, and there was a bit growing tendency but there was no differece in Mn. 6. The mean concentration of Copper which used Cu pipe as a water supply pipe in apartment were $0.216mg/{\ell}(0.161-0.338mg/{\ell})$ in case of the Zine pipe were $0.286mg/{\ell}(0.204-0.435mg/{\ell})$. It shows that the detection rate was more higher than the other material used in Cu or Zn as the water supply pipe. We supposed to Cu and Zn substance were gushing out water supply pipe.

  • PDF

Susceptibility tests of oral antibiotics including cefixime against Escherichia coli, isolated from pediatric patients with community acquired urinary tract infections (소아 원외 요로감염 환아에서 분리된 E. coli에 대한 cefixime을 포함한 경구 항생제의 감수성 연구)

  • Lee, Soo Young;Lee, Jung Hyun;Kim, Jong Hyun;Hur, Jae Kyun;Kim, Sun Mi;Ma, Sang Hyuk;Kang, Jin Han
    • Clinical and Experimental Pediatrics
    • /
    • 제49권7호
    • /
    • pp.777-783
    • /
    • 2006
  • Purpose : Urinary tract infection(UTI) is one of the most frequent infections in children. E. coli is the most frequent etiological micropathogen in pediatric community UTI, and E. coli has developed resistance to many antibiotics, highlighting the need for regular surveys of this organism resistant patterns in the community. The aim of this study was to determine the oral antibiotic susceptibility patterns of E. coli, isolated from pediatric patients with uncomplicated community acquired UTI. Methods : E. coli isolates, obtained from pediatric patients with uncomplicated community acquired UTI between October in 2004 to September in 2005. And minimal inhibitory concentrations(MICs) of oral aminopenicillins and beta-lactamase inhibnitors(ampicillin, amoxacillin, ampicillin-sulbactam), oral cephalosporins(cefaclor, cefixime) and sulfa drug(trimethoprime-sulfamethoxazole) were performed according to the National Committee for Clinical Laboratory Standards(NCCLS) guide line. Results : Total 211 organisms were isolated from pediatric out-patients with community UTI. E. coli was the most common organism(89 percent), followed by E. fecalis, Proteus species, S. aureus, M. morganii, and P. aeruginosa. The resistant rates of aminopenicillins and beta-lactamase inhibitors, cefaclor and sulfa drug to E. coli were very high. But, the resistant rate of cefixime was markedly low, and ESBL strains were isolated with small rates. Conclusion : Our study results suggest that aminopenicillins, cefaclor and sulfa drug may not be useful as first line empirical antibiotics to treat pediatric patients with community UTI in Korea. But, 3rd generation cephalosporin such as cefixime can be used as effective second line antibiotics after primary treatment failure, also may be useful as an empirical first line antibiotic. Finally, we conclude that a continuous surveillance study to monitor susceptibility patterns of E. coli in community UTI will be needed for the standard guide lines of empirical oral antibiotic treatment.