• Title/Summary/Keyword: one-way void slab

Search Result 4, Processing Time 0.023 seconds

Development of One-way Void Support Device for Flexible Table Form (가변형 테이블폼용 일방향 중공관 지지장치 개발)

  • Kwon, Woobin;Lee, Dongmin;Lee, Changsu;Cho, Hunhee;Kang, Kyung-In
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2019.11a
    • /
    • pp.12-13
    • /
    • 2019
  • Flexible Table Form is being used more frequently at the level of formwork in construction site. However, one of the most common structural frameworks, the RC column-beam structure, is having problems in these factors. To improve this problems, this study developed support devices and proposed installation specifications to enable application of the one-way void slab method to flexible table form. It is expected that the effects of reducing the self-weight of the slab in the floor slab construction using flexible table form.

  • PDF

Structural Performance of One-way Void Plywood Slab System with form work Pane (거푸집 패널이 부착된 1방향 중공슬래브의 구조 성능)

  • Hur, Moo-Won;Chae, Kyoung-Hun;Hwang, Kyu-Seok;Yoon, Sung-Ho;Park, Tae-Won
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.25 no.1
    • /
    • pp.7-15
    • /
    • 2021
  • In this study, we developed Void Plywood Slab (VPS) that improved the shape of existing hollow materials. Its performance was evaluated through one-way flexural and one-way shear tests using the developed VPS. As a result of the one-way flexural performance tests of VPS, the yield load value for FPS series(longitudinal direction specimens with hollow materials) was approximately 97.5% compared to FPS-00(without hollow materials) specimen. The tests showed that the yield load was not much different. In addition, FNS series(transverse direction specimens with hollow materials) also represented about 97% of FPS-00 specimen. The one-way flexural performance was shown to have little impact from void materials. Therefore, it is confirmed that the presented system is applicable to the VPS to the slab design. The results of the one-way shear performance tests of VPS showed that it was about 92% compared to the SS-00(without hollow materials) specimen. These results were somewhat insufficient for the SS-00 specimen. Shear strength equation is expressed as the sum of shear force by concrete and shear force by reinforcement. However, in the case of void slab, it is believed that the concrete section has been deleted by the void material. However, the strength of the structure applied to the shear design, as with the flexural design, is also applied to the design based on the yield load value.

Experimental Study on Bending and Shear Performance of Deck Type Void Slab with Trapezoidal Hollow Ball (사다리꼴 형상의 경량체를 가진 데크형 중공슬래브의 휨 및 전단성능에 대한 실험적 연구)

  • Kim, Pil Jung;Kim, Sang Mo;Park, Joon Hyuk
    • Journal of Korean Society of Steel Construction
    • /
    • v.29 no.6
    • /
    • pp.443-453
    • /
    • 2017
  • In this study, a trapezoidal hollow ball is used, instead of a spherical hollow ball commonly used in void slab, to secure the high hollow ratio in the deck type void slab. The bending and shear performance was measured with consideration for the shape change of the hollow ball. And to confirm the effect of deck plate and truss wire on shear performance, experiments were performed depending on the installation directions of the one-way deck plate. As a result, the bending performance of the deck type void slab with a trapezoidal hollow ball was similar to that of the void slab with a spherical hollow ball. However, according to the data of shear strength examined, the contribution of shear performance enhancement of the truss wire had a more effect on the shear performance of deck type void slab, rather than the influence by changing of the shape of hollow ball. In the previous studies, the shear strength is reduced to about 60%, due to the reduction of the effective section of concrete by installation of hollow ball. But in this experiment, the maximum load of specimen, in which the deck was installed in horizontal direction, so expected to have no influence on the shear performance, was only reduced to about 87%, due to the truss framework of truss wire.

An Experimental Study on Estimation of Size and Thickness of Cavitation(Void)s under Concrete Slabs and Tunnel Linings Using Law Frequency Type Radar(GPR) (저주파수 레이더(GPR)에 의한 콘크리트 상판 및 터널 라이닝 배면 공동의 크기 및 두께 추정에 관한 실험 연구)

  • Park, Seok-Kyun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.10 no.6
    • /
    • pp.95-104
    • /
    • 2006
  • The presence of cavitations under pavements or behind tunnel linings of concrete is likely to result in collapse. One method of detecting such voids by non-destructive means is low frequency type radar(GPR). By the way, the size and thickness of small cavitation can't be detected by the present radar technology with low frequency and low resolution when it apply to civil structures like that. To overcome these problems and limitations, this study aims to develope and propose a new analysis method for estimating the depth, cross-sectional size and thickness of cavitations using low frequency radar. A new proposed method is based on the experiments that are carried out for analyzing the correlation between the measurement values(the amplitudes of radar return) of low frequency radar and various type of cavitations. In this process, the threshold value for radar image processing which aims to represent only cavitations to be fitted size can be obtained. As the results, it is clarified that a proposed method has a possibility of estimating cavitation depth, size and thickness with good accuracy in laboratory scale.