• Title/Summary/Keyword: one-way delay

Search Result 163, Processing Time 0.025 seconds

A Survey on the Perceived Importance and Difficulty to Set up the Job Duties of Nutrition Teachers in Elementary School (초등학교 영양교사 직무설정을 위한 직무중요도 및 난이도 조사)

  • Sin, Gyeong-Hui;Sin, Eun-Gyeong;Park, Yu-Hwa;Kim, Hyeon-Hui;Bae, In-Suk;Lee, Yeon-Gyeong
    • Journal of the Korean Dietetic Association
    • /
    • v.12 no.2
    • /
    • pp.105-117
    • /
    • 2006
  • The purpose of this study was to investigate the needs of educators, learners and parents in elementary schools for implementing a systematic nutrition education program by nutrition teachers to begin in 2006. The subjects were 833 dietitians, 808 principals, 3,141 teachers, 7,577 students and 6,003 parents in elementary schools. A fairly large proportion of the principals (98.4%), teachers (95.5%), parents (96.6%) and students (62.8%) responded that nutrition education is urgently needed. Every dietitian, principal and teacher has recognized that for the enforcement of a nutrition program in the future, the placement of one nutrition teacher in every school is needed without a moment's delay. Many subjects responded that elementary low grades are the most proper time for nutrition education for students and it is also needed to extend this not only to students, but also parents and teachers who have a direct influence on them. In the education hour, they responded that it is proper one hour a month for teachers and one hour a week for students. Fifty-six percent of dietitians, 58.3% of principals and 67.0% of teachers responded that the best educational way to heighten the effect of nutrition education was education through discretional activities. It was found that 46.4% of students have wanted nutrition education to be enforced during special activities. Education through their school homepage or in-school broadcasting system, while it has been most utilized, was low in a degree of preference with 10.9%. In regards to a nutrition program, principals and parents have attached much importance to the dining etiquette, dietary attitudes, and relations of foodstuffs with health, while dietitians and teachers have made much of a balanced eating habit, and the relations of dietary life with health. Finally, for a nutrition program to be enforced towards a direction that the educators and students want, it is judged that first of all the role of nutrition teachers is the most important, furthermore the support of manpower and the budget should be made.

  • PDF

An Experimental Study for Substitutability of Sand Mat with Fiber Mat (Fiber Mat의 Sand Mat 대체가능성평가를 위한 실험적 연구)

  • Lee Song;Jeong Yong-Eun
    • Journal of the Korean Geotechnical Society
    • /
    • v.21 no.5
    • /
    • pp.225-230
    • /
    • 2005
  • At present, there are several problems related with sand mat which is used as a way to accelerate consolidation settlement, to act like an underground drainage layer and to increase trafficability simultaneously. First of all, the unbalance of the demand and supply of sand is one of the biggest problems, which causes not only price rise but also delay of the term of the total construction work. Secondly, the damage of ecosystem and scenery is triggered by thoughtless sand dredging or mining. So, the need that sand mat should be replaced with a new environmentally friendly material has been increased. Fiber mat may be one of the proper materials that suits the need. Therefore, we intended to compare the drainage properties of sand mat with those of fiber mat by experimental model tests. On the basis of the test results, fiber mat took shorter period of consolidation than sand mat and the amount of settlement in the farmer showed a little bit bigger than in the latter. As a conclusion, the substitutability of sand mat with fiber mat could be placed highly in view of drainage efficiency. Furthermore, when fiber mat is used, it has an advantage that spoiled soil of the construction site or nearby site can be used for the purpose of increasing trafficability in addition to a role of drainage layer.

Batching delivery for VCR-like functions in video-on-demand service system (주문형 비디오 서비스 시스템에서 VCR 기능을 위한 Batching 전송)

  • 박호균;유황빈
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.22 no.12
    • /
    • pp.2852-2859
    • /
    • 1997
  • Video-On-Demand system provides electronic video rental services from remote video servers on a broadband communication networks. Most of proposed VOD systems are typically designed for one-to-one conncetion between a user and video server. Therefore, video server stream services to customers individually by allocating a dedicated transmission channel and a set of video server resources for each customer. However, it is inefficiency and wxpensive way when server support multiple users who access the same video stream with a dedicated video channel. Therefore, to achieve cost-effectiveness, batching have studied method that uses multicast communication to simultaneously service all users requesting the same video with a single video with a single video stream. However, the application of the multicast communication by batching detract from the VCR-like function and on-demand nature of the system. In this paepr, we propose a scheme that can support an interactive VCR for all user requesting the same video stream with batching. To reduce a server I/O and network bandwidth requirement, dynamic buffer is allocated to access node which has variable playout poit. Consequently, it makes possible interactive VCR operation as if customer uses true VOD system. Also, this scheme can just deliver a multicast stream without delay after an initial request or VCR action occurred. The policy can guarantee acceptable services to number of users at minimum cost.

  • PDF

A study on improving fairness and congestion control of DQDB using buffer threshold value (버퍼의 문턱치값을 이용한 DQDB망의 공평성 개선 및 혼잡 제어에 관한 연구)

  • 고성현;조진교
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.22 no.4
    • /
    • pp.618-636
    • /
    • 1997
  • DQDB(Distributed Queue Dual Bus) protocol, the IEEE 802.6 standard protocol for metropolitan area networks, does not fully take advantage of the capabilities of dual bus architecture. Although fairness in bandwidth distribution among nodes is improved when using so called the bandwidth balancing mechanism, the protocol requires a considerable amount of time to adjust to changes in the network load. Additionally, the bandwidth balancing mechanism leaves a portion of the available bandwidth unused. In a high-speed backbone network, each node may act as a bridge/ router which connects several LANs as well as hosts. However, Because the existence of high speed LANs becomes commonplace, the congestionmay occur on a node because of the limitation on access rate to the backbone network and on available buffer spaces. to release the congestion, it is desirable to install some congestion control algorithm in the node. In this paper, we propose an efficient congestion control mechanism and fair and waster-free MAC protocol for dual bus network. In this protocol, all the buffers in the network can be shared in such a way that the transmission rate of each node can be set proportional to its load. In other words, a heavily loaded node obtains a larger bandwidth to send the sements so tht the congestion can be avoided while the uncongested nodes slow down their transmission rate and store the incoming segments into thier buffers. this implies that the buffers on the network can be shared dynamically. Simulation results show that the proposed probotol significantly reduces the segment queueing delay of a heavily loaded node and segment loss rate when compared with original DQDB. And it enables an attractive high throughput in the backbone network. Because in the proposed protocol, each node does not send a requet by the segment but send a request one time in the meaning of having segments, the frequency of sending requests is very low in the proposed protocol. so the proposed protocol signigificantly reduces the segment queuing dely. and In the proposed protocol, each node uses bandwidth in proportion to its load. so In case of limitation of available buffer spaces, the proposed protocol reduces segment loss rate of a heavily loaded node. Bandwidth balancing DQDB requires the wastage of bandwidth to be fair bandwidth allocation. But the proposed DQDB MAC protocol enables fair bandwidth without wasting bandwidth by using bandwidth one after another among active nodes.

  • PDF

EFFECT OF LIGHT IRRADIATION MODES ON THE MARGINAL LEAKAGE OF COMPOSITE RESIN RESTORATION (광조사 방식이 복합레진 수복물의 변연누출에 미치는 영향)

  • 박은숙;김기옥;김성교
    • Restorative Dentistry and Endodontics
    • /
    • v.26 no.4
    • /
    • pp.263-272
    • /
    • 2001
  • The aim of this study was to investigate the influence of four different light curing modes on the marginal leakage of Class V composite resin restoration. Eighty extracted human premolars were used. Wedge-shaped class Y cavities were prepared on the buccal surface of the tooth with high-speed diamond bur without bevel. The cavities were positioned half of the cavity above and half beyond the cemento-enamel junction. The depth, height, and width of the cavity were 2 mm, 3 mm and 2 mm respectively. The specimens were divided into 4 groups of 20 teeth each. All the specimen cavities were treated with Prime & Bond$^{R}$ NT dental adhesive system (Dentsply DeTrey GmbH, Germany) according to the manufacturer's instructions and cured for 10 seconds except group VI which were cured for 3 seconds. All the cavities were restored with resin composite Spectrum$^{TM}$ TPH A2 (Dentsply DeTrey GmbH, Germany) in a bulk. Resin composites were light-cured under 4 different modes. A regular intensity group (600 mW/${cm}^2$, group I) was irradiated for 30 s, a low intensity group (300 mW/${cm}^2$, group II) for 60 s and a ultra-high intensity group (1930 mW/${cm}^2$, group IV) for 3 s. A pulse-delay group (group III) was irradiated with 400 mW/${cm}^2$ for 2 s followed by 800 mW/${cm}^2$ for 10 s after 5 minutes delay. The Spectrum$^{TM}$ 800 (Dentsply DeTrey GmbH, Germany) light-curing units were used for groups I, II and III and Apollo 95E (DMD, U.S.A.) was used for group IV. The composite resin specimens were finished and polished immediately after light curing except group III which were finished and polished during delaying time. Specimens were stored in a physiologic saline solution at 37$^{\circ}C$ for 24 hours. After thermocycling (500$\times$, 5-55$^{\circ}C$), all teeth were covered with nail varnish up to 0.5 mm from the margins of the restorations, immersed in 37$^{\circ}C$, 2% methylene blue solution for 24 hours, and rinsed with tap water for 24 hours. After embedding in clear resin, the specimens were sectioned with a water-cooled diamond saw (Isomet$^{TM}$, Buehler Co., Lake Bluff, IL, U.S.A.) along the longitudinal axis of the tooth so as to pass the center of the restorations. The cut surfaces were examined under a stereomicroscope (SZ-PT Olympus, Japan) at ${\times}$25 magnification, and the images were captured with a CCD camera (GP-KR222, Panasonic, Japan) and stored in a computer with Studio Grabber program. Dye penetration depth at the restoration/dentin and the restoration/enamel interfaces was measured as a rate of the entire depth of the restoration using a software (Scion image, Scion Corp., U.S.A.) The data were analysed statistically using One-way ANOVA and Tukey's method. The results were as follows : 1. Pulse-Delay group did not show any significant difference in dye penetration rate from other groups at enamel and dentin margins (p>0.05) 2. At dentin margin, ultra-high intensity group showed significantly higher dye penetration rate than both regular intensity group and low intensity group (p<0.05). 3. At enamel margin, there were no statistically significant difference among four groups (p>0.05). 4. Dentin margin showed significantly higher dye penetration rate than enamel margin in all groups (p<0.05).

  • PDF

GET Imaging Evaluation of Patients with Esophageal Cancer (식도암 환자의 GET 영상 평가)

  • Moon, Jong Wun;Lee, Chung Wun;Seo, Young Deok;Yun, Sang Hyeok;Kim, Yong Keun;Won, Woo Jae
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.17 no.2
    • /
    • pp.31-36
    • /
    • 2013
  • Purpose: Measure gastric emptying time (GET: Gastric Emptying Time) is a non-invasive and quantitative evaluation methods, mainly by endoscopic or radiological examination confirmed no mechanical obstruction in patients with symptoms of congestion is checked. Such tests are not common gastric emptying time measured esophageal cancer patients (who underwent esophagectomy) patients after surgery for gastric emptying time was measured test. And the period of time for more than one year after the gastric emptying time measurement was performed. By comparing the two kinds of tests in the chest cavity after surgery as the evaluation of gastrointestinal function tests evaluate the usefulness of GET, and will evaluate the characteristics of the image. Materials and Methods: 93 patients who underwent esophagectomy with gastric emptying time measurement of subject tests immediately after surgery and after 1 year or longer were twice. Preparation of the patient before the test is more than 12 hours of overnight fasting is important, in addition to the medicine or to stop smoking, and diabetes insulin injections should be early in the morning is ideal to test. Generally labeled with $^{99m}Tc-DTPA$ resin which is used to make steamed egg, seaweed and fermented milk with a high viscosity after eating, three hours in the standing position was measured. Evaluation of gastric emptying curves on the way intragastric radioactivity level by 50% the time (half-time [T1/2]) was calculated, based on the half-life was divided into three steps: over 180 minutes was defined as delayed gastric emptying, within 180minutes was defined as intermediate gastric emptying and when all the radioisotopes were dumped into the jejunum as soon as swallowed, was defined as rapid gastric emptying. Results: Gastric emptying time of a typical images stomach of antrum and fundus additional images appear stronger over time move on to the small intestine. but esophageal cancer who underwent esophagectomy side of the thoracic cavity showed a strong image. Immediately after surgery, the half-time (T1/2) of rapid gastric emptying appeared to 12.9%, intermediate gastric emptying appeared to 52.7%, delay gastric emptying appeared to 34.4%. After more than a year the results of the half-life after surgery, 67% of rapid gastric emptying to intermediate gastric emptying was changed, 69% of delay gastric emptying to intermediate gastric emptying changed. Intermediate gastric emptying worse in patients rapid gastric emptying and the delay gastric emptying is 24% in the case. Conclusion: Esophagectomy for esophageal cancer who underwent half-time measurement test (T1/2) rapid gastric emptying and delay gastric emptying are the result of the comparison over time, changes were observed intermediate gastric emptying. Mainly seeing of gastric emptying time measurement in the esophagus instead of thoracic cavity to check the evaluation of gastrointestinal function can be useful even means. And segmentation criteria and narrow time interval of checking if more accurate information and analysis of the clinical diagnosis and evaluation seems to be done.

  • PDF

Vacuum Packaging of MEMS (Microelectromechanical System) Devices using LTCC (Low Temperature Co-fired Ceramic) Technology (LTCC 기술을 이용한 MEMS 소자 진공 패키징)

  • 전종인;최혜정;김광성;이영범;김무영;임채임;황건탁;문제도;최원재
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.10 no.1
    • /
    • pp.31-38
    • /
    • 2003
  • In the current electronic technology atmosphere, MEMS (Microelectromechanical System) technology is regarded as one of promising device manufacturing technologies to realize market-demanding device properties. In the packaging of MEMS devices, the packaged structure must maintain hermeticity to protect the devices from a hostile atmosphere during their operations. For such MEMS device vacuum packaging, we introduce the LTCC (Low temperature Cofired Ceramic) packaging technology, in which embedded passive components such as resistors, capacitors and inductors can be realized inside the package. The technology has also the advantages of the shortened length of inner and surface traces, reduced signal delay time due to the multilayer structure and cost reduction by more simplified packaging processes owing to the realization of embedded passives which in turn enhances the electrical performance and increases the reliability of the packages. In this paper, the leakage rate of the LTCC package having several interfaces was measured and the possibility of LTCC technology application to MEMS devices vacuum packaging was investigated and it was verified that improved hermetic sealing can be achieved for various model structures having different types of interfaces (leak rate: stacked via; $4.1{\pm}1.11{\times}10^{-12}$/ Torrl/sec, LTCC/AgPd/solder/Cu-tube; $3.4{\pm}0.33{\times}10^{-12}$/ Torrl/sec). In real application of the LTCC technology, the technology can be successfully applied to the vacuum packaging of the Infrared Sensor Array and the images of light-up lamp through the sensor way in LTCC package structure was presented.

  • PDF

Effect of Timing of Light Curing on the Shear Bond Strength of Three Self-adhesive Resin Cements

  • Yoo, Yeon-Kwon;Kim, Sung-Hun;Ryu, Jae-Jun;Ryu, Jae-Jun
    • Journal of Korean Dental Science
    • /
    • v.1 no.1
    • /
    • pp.28-34
    • /
    • 2008
  • Objectives. The objectives of this study were: 1) to compare the effect of varying timing of light curing on shear bond strength, and; 2) to compare the shear bond strength of three self-adhesive cements. Materials and methods. A total of 72 extracted non-carious teeth were divided into 24 for Unicem tests, 24 for Maxcem tests, and 24 for Biscem tests; they were assigned 3 * 2 subgroups of 12 teeth each. The specimens were prepared as follows: 1) The calculus and periodontal ligament were removed from the teeth; 2) The teeth were stored in normal saline; 3) The occlusal enamel of each tooth was removed using high-speed coarse diamond burs under water cooling, and; 4) Finally, the teeth were flattened by 600-grit silicone carbide paper disks. Resin blocks were adhered using either Unicem, Maxcem, or Biscem. Light curing timing was divided into two groups: U10, M10, and B10 were exposed to light after 10 seconds, and; U150, M150, and B150 on the other side were exposed to light after 150 seconds. Shear bond strength was measured by a Universal testing machine with cross head speed of 1mm/min. T-test and One way ANOVA were used for the statistical analysis of data. Results. The shear bond strength of U150 was not significantly higher than that of U10 (U150: 20.55.7Mpa, U10: 18.73.80Mpa). On the other hand, the shear bond strength of M150 was significantly higher than that of M10. The shear bond strength of B150 was also significantly higher than that of B10 (M150:14.45.7Mpa, M10: 9.94.2Mpa, B150: 24.38.3Mpa, B10: 17.27.3Mpa). When the light curing timing was 10sec after bonding, the shear bond strength of Unicem was highest; the shear bond strength of Biscem was highest when the light curing timing was 150sec after bonding (U10: 18.73.80Mpa, B150: 24.38.3Mpa). Significance. Since Unicem is less sensitive based on light curing timing, dentists seem to use it without considering the light curing timing. Maxcem showed the lowest bonding strength (especially M10). Thus, when using Maxcem, dentists need to delay the light curing after adhesion.

  • PDF

The Objective Image Analysis for HCC and HH with a Axial Image of Liver CT Scan (Liver CT 단면영상에서 간세포암과 간혈관종의 객관적 영상분석)

  • Hwang, In-Gil;Ko, Seong-Jin;Choi, Seok-Yoon
    • The Journal of the Korea Contents Association
    • /
    • v.15 no.9
    • /
    • pp.411-417
    • /
    • 2015
  • To distinguish between HCC and HH is one of the important test methods in determining the treatment method by determining the treatment method by distinguishing malignant growth and benign tumors in liver CT scan. Currently, the specialist is reading CT images by their subjective judgment. So, the purpose of this study is to treat reading the CT images even more objective way. The test times after injection contrast medium in this study are the before injection phase(Pre.), artery phase(35sec), portal phase(70sec) and delay phase(180sec). The general pattern change of HCC in change of contrast enhancement pattern shows 26.6% matching. And the case of HH shows 16.6% matching. In order to observe the change of HU value between HCC and HH, each average values and standard deviation was confirm and as a result, it shows the lagre difference between artery and portal phase in lesion.(HCC$19.76{\pm}23.52$, HH$60.23{\pm}29.43$). And it shows the 76.6% matching in HCC and 80.0% matching in HH. Thorough this study, to suggest a HU value as objective analysis method and if the anlaysis method was used in clinical will assist in the diagnosis.

Layer 2 Routing with Multi-Spanning Tree Per a Node (노드 당 다중 스패닝 트리를 이용한 2계층 라우팅)

  • Suh, Chang-Jin;Shin, Ji-Soo;Kim, Kyung-Mi
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.33 no.9B
    • /
    • pp.751-759
    • /
    • 2008
  • Carrier Ethernet backbone network integrates distributed layer-2 based metro networks. In this networks, Multiple Spanning Tree Protocol (MSTP) has been uscd as a main routing protocol that allows multiple spanning trees in a network. A better routing protocol called IEEE802.1aq - Shortest Path Bridging (SPB) is recently proposed, that generates the shortest spanning tree per a destination node. As SPB provides a routing path per a destination node, there is no way to adapt network traffic at normal condition. If we are free from the principle of "a spanning tree per a destination node", we can achieve adaptive routing. Based on this philosophy, we propose a new spanning tree based protocol - Edge Node Divided Spanning Tree (ENDIST). ENDIST divides an edge node into sub-nodes as many as connecting links from the node and each sub-node generates a single shortest path tree based on SPB. Depending on network or nodal status, ENDIST chooses a better routing path by flow-basis. This added traffic engineering ability contributes to enhanced throughput and reduced delay in backbone networks. The simulation informs us that ENDIST's throughput under heavy load performs about 3.4-5.8 and 1.5-2.0 times compared with STP's and SPB's one respectively. Also, we verified that ENDIST's throughput corresponds to the theoretical upper bound at half of cases we investigated. This means that the proposed ENDIST is a dramatically enhanced and the close-to-perfect spanning tree based routing schemes.