• 제목/요약/키워드: one-way contact

검색결과 200건 처리시간 0.033초

치과용 스캐너의 광원에 따른 디지털 모형의 정확도 비교연구 (Comparative study of accuracy of digitized model fabricated by difference optical source of non-contact 3D dental scanner)

  • 김재홍;이정수;심정석
    • 대한치과기공학회지
    • /
    • 제39권4호
    • /
    • pp.227-233
    • /
    • 2017
  • Purpose: The purpose of this study was to evaluate the validity of digital models fabricated by difference optical source of non-contact 3D dental scanner. Methods: A master model with the prepared upper full arch tooth was used. Stone model(N=10) were produced from master model, and on the other hands, digital models were made with the 3D dental scanner(Blue, white, red optical source). The linear distance between the reference points were measured and analyzed on the Delcam $Copycad^{(R)}$ graphic software. The results were statistically analyzed using the one-way ANOVA and Tukey's HSD test(${\alpha}=0.05$). Results: There were considerable differences in mean values between optical source within each color(blue, white, red), and this difference was not statistically significant(p>0.05). Conclusion : Three different color of dental scanner optical source showed clinically acceptable accuracies of full arch digital model produced by them. Besides, these results will have to be confirmed in further clinical studies.

Effect of Insamyangyoung-tang on the Skin Barrier Function of Hairless Mice

  • Nam, Hae-Jeong;Kim, Yoon-Bum
    • 대한한의학회지
    • /
    • 제28권4호
    • /
    • pp.18-26
    • /
    • 2007
  • Objective : To study the effect of the Insamyangyoung-tang(ISYT) extract on the skin barrier function, the skin pH, skin humidity and transepidermal water loss(TEWL) were measured and histological changes were observed in DNCB(2,4-dinitrochloro-benzen)-induced contact dermatitis(CD) hairless mice. Methods : The male hairless mice were divided into three groups. Each group consisted of 15 mice. The normal group which had acetone- olive oil applied. The control group which had intentionally induced CD by DNCB and it was fed normal saline orally. The ISYT group which had intentionally induced CD by DNCB and it was fed ISYT extract orally for 7 days. The three groups were checked 24h, 48h and 72h later after inducing CD, and the skin pH, skin humidity and TEWL were observed. Tissue samples were taken, and damage to the epithelial cell was observed. Statistical analysis was performed by using one way-ANOVA: significance was set at p values less than 5% (p<0.05). Results : ISYTextract efficiently maintained the pH balance, it kept the skin humidity at a normal level, and it inhibited TEWL of the DNCB-induced CD hairless mouse. The damage to the epithelium was decreased and the regeneration power of the skin was increased in the ISYT group. Conclusion : Insamyangyoung-tang has a good effect on the skin barrier function of DNCB induced contact dermatitis hairless mice.

  • PDF

No-insulation 기법을 적용한 소용량 고온 초전도 코일의 영구전류 특성에 관한 연구 (A Study on the Basic Characteristics of Persistent Current Mode Operation for Small Scale High Temperature Superconducting Coil with No-insulation Winding Method)

  • 이태성;이우승;최석진;조현철;김형준;이지호;강재식;권오준;이해근;고태국
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제14권3호
    • /
    • pp.23-27
    • /
    • 2012
  • This paper aims to evaluate the feasibility of using no-insulation High Temperature Superconducting (HTS) coil in persistent current mode system. A HTS coil in persistent current mode system usually includes one or more non-superconducting joints in its circuit. And the current decaying rate of the coil is affected by the resistance of joint in persistent current circuit. If the resistance of joint is large, decaying rate of the current drastically increases. Therefore, reducing the joint resistance of the HTS coil is very important in persistent current mode system. In this paper, the no-insulation HTS coil is suggested as a way to reduce the joint resistance with the embedded parallel contact resistance naturally made by no-insulation winding method. Two small coils are fabricated with insulation and no-insulation winding method, and persistent current mode system experiment of each coil is preformed and analyzed.

Methods of Improving Operational Reliability of Oil Well Casing

  • Sergey A. Dolgikh;Irek I. Mukhamatdinov
    • Corrosion Science and Technology
    • /
    • 제23권1호
    • /
    • pp.1-10
    • /
    • 2024
  • Oil well casing leak is caused by contact of casing outer surface with formation electrolyte. It is usually associated with an aquifer with a high salt content or absence of a cement ring behind the casing. The only way to reduce external casing corrosion is through cathodic protection. Through cathodic polarization of casing structure, electron content in crystal lattice and electron density will increase, leading to a potential shift towards the cathodic region. At Tatneft enterprises, cathodic protection is carried out according to cluster and individual schemes. The main criterion for cathodic protection is the size of protective current. For a casing, the protective current is considered sufficient if measurements with a two-contact probe show that the electric current directed to the casing has eliminated all anode sites. To determine the value of required protective current, all methods are considered in this work. In addition, an analysis of all methods used to determine the minimum protective current of the casing is provided. Results show that the method of measuring potential drop along casing is one of the most reliable methods for determining the value of protective current.

보행 시작과 멈추는 거리가 보행 변인에 미치는 영향 (The Effects of Start and Finish Distance on the Gait Variables during Walking)

  • 임비오;안승현;이상우;도인영
    • 한국운동역학회지
    • /
    • 제17권1호
    • /
    • pp.17-27
    • /
    • 2007
  • It is essential for gait analysis to know the distance information. The purpose of this study was to investigate the effects of start and finish distance on the gait variable during walking. Six adolescent participated in this study. Start condition was given by six conditions.: walking forward from (1) one step, (2) three steps, (3) five steps, (4) ten steps, (5) one step after standing walk, and (6) three steps after standing walk, before contacting the force plate. Stop condition was given by four conditions. : stop after (1) one step, (2) two steps, (3) three steps, and (4) ten steps, passing force plate. Repeated measured one-way ANOVA was utilized for data analysis, and the significant level was set at .05. The largest change from the difference of gait velocity exists between the variables of ground reaction force. There were no significant differences in spatio-temporal and posture(angle) variables, as well as ground reaction force variables with walking over the three steps. There were significant differences in gait velocity, knee angle at heel contact, vertical impulse and ankle angle at toe off in short distance.

부가중합형 실리콘 교합인기재의 탄성 특성 (Elastic properties of addition silicone interocclusal recording materials)

  • 이영옥;김경남
    • 한국치위생학회지
    • /
    • 제12권3호
    • /
    • pp.513-520
    • /
    • 2012
  • Objectives : In this study, contact angle and shore D hardness were measured, and a shark fin test was conducted after selecting five addition silicon(Blu-Mousse, BM; EXABITE II, EX; PERFECT, PF; Regisil$^{(R)}$ Rigid, RE; Silagum$^{(R)}$, SI) in order to figure out the properties of elastomeric interocclusal recording materials and reduce errors at interocclusal recording. 8) Methods : A contact angle was measured using a contact angle analyzer. After placing a drop of liquid on the surface of the specimens of interocclusal recording materials, a contact angle was photographed with a CCD camera on the equipment. In terms of a shark fin test, interocclusal recording materials were mixed for the time proposed by the manufacturer and inserted into the split ring of the Shark fin device. Twenty (20) seconds exactly, a metal rod was removed to make the materials slowly absorbed. Once they hardened, fin height was measured with a caliper after separating molds and trimming the specimens. The shore D hardness was measured with a shore D hardness tester(Model HPDSD, Hans Schmidt & Co. Gmbh, Germany) in sixty (60) minutes after fabricating specimens. In each experiment, five specimens, mean and standard deviation were calculated. A one-way ANOVA test was performed at the p>0.05 level of significance. In terms of correlation among the tests, Pearson correlation coefficient was estimated. For multiple comparison, Scheffe's test was carried out. Results : A contact angle was the highest in EX with $99.23^{\circ}$ (p<0.05) while the result of the shark fin test was the longest in RE with 5.45mm. SI was the lowest (0.27mm) with statistical significance. Among the interocclusal recording materials, significant difference was observed in terms of means (p<0.05). The shore D hardness was the highest in SI with 31.0 while RE was significantly low with 16.4 (p<0.05). Among the materials, statistically significant difference was observed in terms of means when compared to the rest materials (RE), BM, RE and SI (PF and EX) and the remaining materials (BM and SI) (p<0.05). In terms of correlations among the tests, a negative correlation occurred between shore D hardness and shark fin test(r=-0.823, p=0.000). Conclusions : According to the study above, it is necessary to understand the properties of interocclusal recording materials and consider contact angle, shark fin test and properties of shore D hardness to select appropriate materials.

체간에 무게 부하를 적용한 정상 성인의 보행 분석 (Gait analysis of Healthy Adults with External Loads on Trunk)

  • 장종성;최진호;이미영;김명권
    • 대한물리의학회지
    • /
    • 제7권1호
    • /
    • pp.69-75
    • /
    • 2012
  • Purpose : The study was designed to investigate analysis of kinematics of lower extremity in healthy adults during walking with external loads on trunk. Methods : Fifteen healthy adults were recruited and The subjects provided written and informed consent prior to participation. They walked on a ten-meter walkway at a self-selected pace with loads of 0, 5, 10, and 15kg. They completed three trials in each condition and kinematic changes were measured. A three-dimensional motion analysis system was used to analyze lower extremity kinematic data. The data collected by each way of walking task and analyzed by One-way ANOVA. Results : There were significant differences in hip and knee joint on saggittal plane at initial contact and preswing, and significant differences in ankle joint on transverse plane at preswing. Conclusion : These findings revealed that increased external loads were changed joint angles and influenced postural strategies because of kinematic mechanism and future studies is recommended to find out prevention from damage of activities of daily living.

조선조여인의 쓰게에 관한 연구 (A study on the Women's Veil of Yi Dynasty)

  • 정광희
    • 대한가정학회지
    • /
    • 제20권4호
    • /
    • pp.13-22
    • /
    • 1982
  • While the women of the Korea Dynasty wore hat(笠子) and Mongsu(蒙首) on top of it when going out, the Yi Dynasty, due to more strict Contucian ethics and isolated way of life, had seen the development of the covering clothes, rather veil, for avoiding the opposite sex with diversity and both men and women began wearing PHO(coat), a Korean topcoat over the head and thurs called Changots, but originally PHO for men was named Changyi a men's outer coat. Neuwul(羅兀), like Mongsu(蒙首) of Korea Dynasty was a thin black hood worn on top of the Wowllip or a kind of skirt draped over the head and the latter was called Changots, very similar to Sgaechima, a kind of long hood formally worn by women. Meanwhile, local women wore a long veil with no arm sleeves dubbed Cheunyi(薦衣) But since western civilization and culture landed on Korea around the end of the 19th century, the women's social status has been raised to almost the same level with men and the way of life has changed towards openness, in which men and women have almost daily contact with one another, so these days we can hardly find such veil style covering clothes around us.

  • PDF

교합균형이 자세 중심(重心)에 미치는 영향에 관한 연구 (Effect of occlusal balance on center of gravity in body)

  • 이윤;최대균;이성복
    • 구강회복응용과학지
    • /
    • 제19권2호
    • /
    • pp.57-67
    • /
    • 2003
  • Suppose that dental occlusion is related to body posture. We want to find out that improving occlusal balance may affect vibration and distribution of C.O.P. in which way, by measuring change of posture and center of gravity (center of pressure, C.O.P.) which plays important role in measuring balance sensation. Total 11 students at Kyung Hee dental college students, 4 females and 9 males (age: 23-30) participated in this test, who have normal occlusion (Angle's classification I), no TMJ problems. All of the participants have no tooth loss except 3rd molar, no prosthesis over single tooth restoration, no orthopedic problems which affect balance sensation, and no otorhinolaryngological problems. First, we registrated bite by centric relation, and then fabricated stabilization splint that is increased 3.5mm vertical dimension around premolar region. By F-scan (Tekscan Inc., Boston, Mass), we measured discrepancy of average contact pressure of left and right foot. And we also measured discrepancy of vibration of C.O.P(center of pressure). before setting stabilization splint and after wearing stabilization splint at intervals of 1 week, 2 weeks, 3 weeks after. In normal human beings, improved occlusal balance by stabilization splint leads to decrease of vibration of C.O.P. (P<0.05). One week after wearing stabilization splint, vibration of C.O.P. decreased reliably (P<0.05), two weeks after wearing stabilization splint, vibration of C.O.P. decreased similarly comparing to before wearing and one week after wearing. (P<0.05) After two weeks and three weeks, however, it was hard to find reliability. (P>0.05) Difference between average contact pressure of right and left foot also decreased. (P<0.05) We could find decrease after one week of wearing stabilization splint (P<0.05) and two weeks after, the decrease was more reliable than one week after. (P<0.05) After two weeks and three weeks, however, it was hard to find reliability. Improvement of occlusal balance leads to decrease of vibration of C.O.P. and decrease of difference between right and left average contact pressure.

The Effects of Different Angles of Wedged Insoles on Knee Varus Torque in Healthy Subjects

  • Jung, Do-Young;Kwon, Oh-Yun;Yi, Chung-Hwi;Kim, Young-Ho;Kim, Jang-Hwan
    • 한국전문물리치료학회지
    • /
    • 제11권4호
    • /
    • pp.31-41
    • /
    • 2004
  • The purpose of this study was to examine the effect of the angle of a wedged insole on knee varus torque during walking. Fifteen healthy subjects were recruited. Knee varus torque was measured using three-dimensional motion analysis (Elite). Knee varus torque was normalized to gait cycle (0%: initial contact; 100%: ipsilateral initial contact) and stance phase (0%: initial contact; 100%: ipsilateral toe off). The average peaks of knee varus torque during the stance phase of the gait cycle according to the different insole angles (10 or 15 degrees) were compared using one-way ANOVA with repeated measures. The results showed that in the early stance phase, the average peak knee varus torque increased significantly for both the medial 10 and 15 degree wedged insole conditions and decreased significantly for both the lateral 10 and 15 degree wedged insole conditions as compared with no insole (p<.05). However, there were no significant differences between the 10 and 15 degree wedged insole conditions with either the medial or lateral wedged insole (p>.05). In the late stance phase, the average peak knee varus torque increased significantly for the medial 10 and 15 degree wedged insole conditions (p<.05), but not for the lateral 10 and 15 degree wedged insole conditions as compared with no insole (p>.05). We suggest that these results may be beneficial for manufacturing foot orthotic devices, such as wedged insoles, to control medial and lateral compartment forces in the knee varus-valgus deformity. Further studies of the effects of wedged insole angle on knee varus torque in patients with medial-lateral knee osteoarthritis are needed.

  • PDF