• 제목/요약/키워드: one-layer

검색결과 4,810건 처리시간 0.032초

Bi-layer Gravure Printed Organic Light Emitting Layers with MEH-PPV and Rubrene

  • Kim, A-Ran;Lee, Hye-Mi;Cho, Sung-Min;Chae, Hee-Yeop
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2009년도 9th International Meeting on Information Display
    • /
    • pp.1508-1510
    • /
    • 2009
  • In this work, we have compared OLED devices made of blended MEH-PPV/Ruburene mixture and MEH-PPV/Rubrene bi-layer structure devices. The emission layers were made with two different ways - one with gravure printed single layer of blended mixture of MEH-PPV and rubrene, the other with gravure printed bilayers of MEH-PPV and rubrene. Both brightness and efficiency with gravure printed bi-layer devices were higher than blended devices. In this work, we demonstrated that organic bi-layers can be formed with gravure printing technology and higher efficiency can be achieved with bi-layer structure than with blended single layer structure.

  • PDF

Bi-2223 선재를 이용한 Prototype 고온 초전도 케이블의 전기적 특성 (An Electrical Properties of Prototype HTS Cable using Bi-2223 tape)

  • 김영석;이병성;장현만;곽민환;김상현
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 C
    • /
    • pp.1551-1553
    • /
    • 2000
  • Superconducting power cable is one of the most promising energy application of high-$T_c$ superconductors (HTS). A prototype HTS cable have been constructed multi-layer cable using Bi-2223 tape and tested. The result shows that the total transport current of HTS cable in $LN_2$ was 475[A], and transport current passed through almost the outer layer (2-layer). Also, AC transport losses in outer layer of HTS cable was proportion to $I^2$ and higher than losses of inner layer. As magnetic distribution were concentrated on outer layer.

  • PDF

Simulation and Design of Optimized Three-Layer Radiation Shielding to Protect Electronic Boards of Satellite Revolving in Geostationary Earth Orbit (GEO) Orbit against Proton Beams

  • Ali Alizadeh;Gohar Rastegarzadeh
    • Journal of Astronomy and Space Sciences
    • /
    • 제41권1호
    • /
    • pp.17-23
    • /
    • 2024
  • The safety of electronic components used in aerospace systems against cosmic rays is one of the most important requirements in their design and construction (especially satellites). In this work, by calculating the dose caused by proton beams in geostationary Earth orbit (GEO) orbit using the MCNPX Monte Carlo code and the MULLASSIS code, the effect of different structures in the protection of cosmic rays has been evaluated. A multi-layer radiation shield composed of aluminum, water and polyethylene was designed and its performance was compared with shielding made of aluminum alone. The results show that the absorbed dose by the simulated protective layers has increased by 35.3% and 44.1% for two-layer (aluminum, polyethylene) and three-layer (aluminum, water, polyethylene) protection respectively, and it is effective in the protection of electronic components. In addition to that, by replacing the multi-layer shield instead of the conventional aluminum shield, the mass reduction percentage will be 38.88 and 39.69, respectively, for the two-layer and three-layer shield compared to the aluminum shield.

연약지반상 고속철도 노반 축조시 지오셀 시스템의 효과 (Reinforcement of Soft Soil Subgrade for High-Speed Railroad Using Geocell)

  • 김진만;조삼덕;윤수호;정문경;김영윤
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 1999년도 토목섬유 학술발표회 논문집
    • /
    • pp.129-141
    • /
    • 1999
  • This paper presents the results of plate load test and dynamic load test performed to evaluate the performance of geocell where it is used to reinforce soft subgrade for high-speed railroad. Efficacy of geocell was observed in increase in bearing capacity of subgrade and reduction of thickness of reinforced sub-ballast. Plate load tests were carried out at four different places with varying foundation soil strength as a function of number of geocell layer, type of filler material, thickness of cover soil, and the presence of non-woven geotextile. Dynamic load tests were performed in a laboratory. The test soil chamber consists of, from the bottom, 50 cm thick clayey soil, one layer of geocell filled with crushed stone, 10 cm thick crushed stone cover, reinforced sub-ballast of varying thickness, 35 cm thick ballast. This configuration was determined based on the results of numerical analysis and plate load tests. For each set of the dynamic load tests, loads were applied more than 80,000 times. One layer of geocell underlying a 10 cm thick cover soil led to an increase in bearing capacity three to four times compared to a crushed stone layer of the same thickness substituted for the geocell and cover soil layer. Given the test conditions, the thickness of reinforced sub-ballast can be reduced by approximately 35 cm with the presence of geocell.

  • PDF

Parametric study on the lateral strength of URM wall, retrofitted using ECC mortar

  • Niasar, Alireza Namayandeh;Alaee, Farshid Jandaghi;Zamani, Sohail Majid
    • Earthquakes and Structures
    • /
    • 제18권4호
    • /
    • pp.451-466
    • /
    • 2020
  • In this paper, the effect of Engineered Cementitious Composites (ECC) on the lateral strength of a bearing unreinforced Masonry (URM) wall, was experimentally and numerically investigated. Two half scale solid walls were constructed and were tested under quasi-static lateral loading. The first specimen was an un-retrofitted masonry wall (reference wall) while the second one was retrofitted by ECC mortar connected to the wall foundation via steel rebar dowels. The effect of pre-compression level, ECC layer thickness and one or double-side retrofitting on the URM wall lateral strength was numerically investigated. The validation of the numerical model was carried out from the experimental results. The results indicated that the application of ECC layer increases the wall lateral strength and the level of increment depends on the above mentioned parameters. Increasing pre-compression levels and the lack of connection between the ECC layer and the wall foundation reduces the influence of the ECC mortar on the wall lateral strength. In addition, the wall failure mode changes from flexure to the toe-crashing behavior. Furthermore, in the case of ECC layer connected to the wall foundation, the ECC layer thickness and double-side retrofitting showed a significant effect on the wall lateral strength. Finally, a simple method for estimating the lateral strength of retrofitted masonry walls is presented. The results of this method is in good agreement with the numerical results.

투수성해안구조물과 불규칙파의 상호작용에 관한 수치모델 연구 (A Study of the Numerical Model on the Interaction between Irregular Waves and Permeable Coastal Structures)

  • 김종욱;남인식;윤한삼;류청로
    • 한국해양공학회:학술대회논문집
    • /
    • 한국해양공학회 2001년도 춘계학술대회 논문집
    • /
    • pp.186-195
    • /
    • 2001
  • The purpose of this study is to develop the time-dependent, one-dimensional numerical model on the interaction between irregular waves and two-layer permeable coastal structures, by extending and modifying the numerical model PBREAK(Wurjanto and Kobayashi, 1992) which is applicable only to one-layer permeable coastal structures. The two-layer permeable coastal structure consists of two permeable underlayers with different permeable media resting on an impermeable slope and an armor layer covering the permeable underlayer. The numerical model of this study simulates the wave over rough permeable underlayer of arbitrary geometry as well as the waves inside two-permeable underlayers of arbitrary thickness for specified normally-incident irregular waves. The utility of the numerical model is founded from comparing with PBREAK and the four hydraulic model tests under irregular waves. The sensitivities of computed results according to typical parameters(porosity, stone diameter, horizontal width of the permeable underlayer) and major factors(friction factor of primary armor layer etc.) discussed.

  • PDF

한국의 골프 코스 그린의 설계 및 시공 특성에 관한 연구 (A Study on the Characteristics of Green Design and Construction of Golf Courses in Korea)

  • 이상재;허근영
    • 아시안잔디학회지
    • /
    • 제13권4호
    • /
    • pp.181-190
    • /
    • 1999
  • This study was carried out to survey green system, area, green slope, green turfgrass variety, green section, and particle size of green construction materials, and to investigate and evaluate the characteristics of Design and Construction in Korean golf course green for improving the quality of Korean golf course into that of the international golf course held international tournament. The results were as follows. 1. The greens of 129 Korean golf courses consisted of 2(two) green system and 1(one) green system. 2(two) green system was 50.8%, 1(one) green system was 40.7%, and 1+2 green system was 8.5% of them. 2. In 48 Korean golf courses, the green area of 2(two) green system was mostly 400~$600\m^2$(56.5%) and the green area of 1(one) green system was mostly 600~$800\m^2$(47.8%). In 48 Korean golf courses, 1.5~3% green slope appeared the highest frequency(50.0%) and the next was 3~5%(29.4%). 3. Penncross variety was the highest frequency(71.2%). The next was mixed variety (Penncross+Crenshaw, Penn A-1, Pennlinks, or Penneagle/SR 1020+SR 1019) and the frequency of mixed variety was 7.6%. 4. In 48 Korean golf courses, 70~80cm total thickness of green appeared the highest frequency(36.1%), 10~20cm thickness of green mixed sandy layer appeared the highest frequency(43.6%), and 10~20cm thickness of green coarse sandy layer appeared the highest frequency(55.6%). 0~10cm thickness of green gravel layer appeared the highest frequency(67.6%), 20~30cm thickness of green drain layer appeared the highest frequency(52.8%), and 20~30cm width of green drain layer appeared the highest frequency(44.4%). Below 1mm sand diameter used in green mixed sandy layer appeared the highest frequency(46.2%), below 2mm or over 2mm sand diameter used in green coarse sandy layer appeared the highest frequency(31.4%). 20~40mm coarse gravel diameter used in green gravel layer appeared the highest frequency(43.2%) and 0~20mm fine gravel diameter used in green gravel layer appeared the highest frequency(65.8%). 20~40mm gravel diameter used in green drain layer appeared the highest frequency(64.1%).

  • PDF

흑연의 내마모성 증진을 위한 다층 코팅 (Multi-layer Coating for Improvement Anti-wear Property of Graphite)

  • 서임춘;김동일;예병한;정발;박종욱
    • 한국세라믹학회지
    • /
    • 제31권8호
    • /
    • pp.874-878
    • /
    • 1994
  • To increase the anti-oxidation and anti-wear properties of graphite for the propellant-burning environment, SiC, Pt and Al2O3 multi-layer coatings were conducted succesisvely and the optimum condition was researched. The SiC layer was produced by pack cementation and SiC layer in thickness of 30 ${\mu}{\textrm}{m}$ coating was produced after coating for 6 hours. Pt layer was coated by sputtering, and the Al2O3 layer was coated by reactive sputtering. the thickness of Pt layer and Al2O3 layer was less than one-tenth of that of SiC layer. The pack coated specimens and multi-layer coated specimens were made using above conditions and test-fired. The test result showed that the wear rate of SiC layer is approximately 1/10 compared to that of uncoated graphite.

  • PDF

수치해석을 이용한 다겹보온자재의 내부공기층 함유에 따른 보온 특성 (Thermal Insulation Property due to Internal Air-layer Content of Warm Multi Layer Materials by using Numerical Analysis)

  • 정성원
    • 한국기계가공학회지
    • /
    • 제11권4호
    • /
    • pp.97-103
    • /
    • 2012
  • This study investigates thermal insulation properties of multi layer materials depending on thickness of air layers. Numerical analysis on the heat flow of different insulating materials was conducted to identify whether their temperature distributions demonstrate the reduced rate of heat transfer conclusively or not. Analytical model is divided into two categories. One is to distinguish temperature distribution of the air-layer materials from the non-air layer ones. The other is to compare the efficacy between eight-layered insulating materials with no air-layer contained and three-layered insulating materials which include an air-layer definitely. In the latter case, the identical thickness is assigned to each material. The effect of thermal insulation by including an air-layer is verified in the first analytical model. The result of the second model shows that the insulation of the eight-layered materials is coterminous at the three-layered ones with an air-layer and the thermal insulation of the two materials is imperceptible. The benefits of cost and energy saving are anticipated if air-layers are efficiently incorporated in multi layer insulating materials in a greenhouse.

Effect of Ti Intermediate Layer on Properties of HAp Plasma Sprayed Biocompatible Coatings

  • Take, Seisho;Otabe, Tusyoshi;Ohgake, Wataru;Atsumi, Taro
    • Corrosion Science and Technology
    • /
    • 제19권2호
    • /
    • pp.51-56
    • /
    • 2020
  • The objective of this study was to improve properties of plasma sprayed HAp layer to titanium substrate by introducing an intermediate layer with two different methods. Before applying Zn doped HAp coating on titanium substrate, an intermediate layer was introduced by titanium plasma spray or titanium anodization. Heat treatments were conducted for some samples after titanium intermediate layer was formed. Zn doped HAp top layer was applied by plasma spraying. Three-point bending test and pull-off adhesion test were performed to determine the adhesion of Zn doped HAp coatings to substrates. Long-term credibility of Zn doped HAp plasma sprayed coatings on titanium was assessed by electrochemical impedance measurements in Hanks' solution. It was found that both titanium plasma sprayed and titanium anodized intermediate layer had excellent credibility. Strong adhesion to the titanium substrate was confirmed after 12 weeks of immersion for coating samples with titanium plasma sprayed intermediate layer. Samples with titanium anodized intermediate layer showed good bending strength. However, they showed relatively poor resistance against pulling off. The thickness of titanium anodized intermediate layer can be controlled much more precisely than that of plasma sprayed one, which is important for practical application.