• Title/Summary/Keyword: one camera

Search Result 1,569, Processing Time 0.19 seconds

EFFECT OF LIGHT IRRADIATION MODES ON THE MARGINAL LEAKAGE OF COMPOSITE RESIN RESTORATION (광조사 방식이 복합레진 수복물의 변연누출에 미치는 영향)

  • 박은숙;김기옥;김성교
    • Restorative Dentistry and Endodontics
    • /
    • v.26 no.4
    • /
    • pp.263-272
    • /
    • 2001
  • The aim of this study was to investigate the influence of four different light curing modes on the marginal leakage of Class V composite resin restoration. Eighty extracted human premolars were used. Wedge-shaped class Y cavities were prepared on the buccal surface of the tooth with high-speed diamond bur without bevel. The cavities were positioned half of the cavity above and half beyond the cemento-enamel junction. The depth, height, and width of the cavity were 2 mm, 3 mm and 2 mm respectively. The specimens were divided into 4 groups of 20 teeth each. All the specimen cavities were treated with Prime & Bond$^{R}$ NT dental adhesive system (Dentsply DeTrey GmbH, Germany) according to the manufacturer's instructions and cured for 10 seconds except group VI which were cured for 3 seconds. All the cavities were restored with resin composite Spectrum$^{TM}$ TPH A2 (Dentsply DeTrey GmbH, Germany) in a bulk. Resin composites were light-cured under 4 different modes. A regular intensity group (600 mW/${cm}^2$, group I) was irradiated for 30 s, a low intensity group (300 mW/${cm}^2$, group II) for 60 s and a ultra-high intensity group (1930 mW/${cm}^2$, group IV) for 3 s. A pulse-delay group (group III) was irradiated with 400 mW/${cm}^2$ for 2 s followed by 800 mW/${cm}^2$ for 10 s after 5 minutes delay. The Spectrum$^{TM}$ 800 (Dentsply DeTrey GmbH, Germany) light-curing units were used for groups I, II and III and Apollo 95E (DMD, U.S.A.) was used for group IV. The composite resin specimens were finished and polished immediately after light curing except group III which were finished and polished during delaying time. Specimens were stored in a physiologic saline solution at 37$^{\circ}C$ for 24 hours. After thermocycling (500$\times$, 5-55$^{\circ}C$), all teeth were covered with nail varnish up to 0.5 mm from the margins of the restorations, immersed in 37$^{\circ}C$, 2% methylene blue solution for 24 hours, and rinsed with tap water for 24 hours. After embedding in clear resin, the specimens were sectioned with a water-cooled diamond saw (Isomet$^{TM}$, Buehler Co., Lake Bluff, IL, U.S.A.) along the longitudinal axis of the tooth so as to pass the center of the restorations. The cut surfaces were examined under a stereomicroscope (SZ-PT Olympus, Japan) at ${\times}$25 magnification, and the images were captured with a CCD camera (GP-KR222, Panasonic, Japan) and stored in a computer with Studio Grabber program. Dye penetration depth at the restoration/dentin and the restoration/enamel interfaces was measured as a rate of the entire depth of the restoration using a software (Scion image, Scion Corp., U.S.A.) The data were analysed statistically using One-way ANOVA and Tukey's method. The results were as follows : 1. Pulse-Delay group did not show any significant difference in dye penetration rate from other groups at enamel and dentin margins (p>0.05) 2. At dentin margin, ultra-high intensity group showed significantly higher dye penetration rate than both regular intensity group and low intensity group (p<0.05). 3. At enamel margin, there were no statistically significant difference among four groups (p>0.05). 4. Dentin margin showed significantly higher dye penetration rate than enamel margin in all groups (p<0.05).

  • PDF

Influence of Gating and Attenuation-correction for Diagnostic Performance of Usual Rest/stress Myocardial Perfusion SPECT in Coronary Artery Disease (게이트 방법과 감쇠보정이 심근 관류 SPECT의 관상동맥질환 진단 성능에 미치는 영향)

  • Lee, Dong-Soo;Yeo, Jeong-Seok;So, Young;Cheon, Gi-Jeong;Kim, Kyeong-Min;Chung, June-Key;Lee, Myung-Chul
    • The Korean Journal of Nuclear Medicine
    • /
    • v.33 no.2
    • /
    • pp.131-142
    • /
    • 1999
  • Purpose: Either gated myocardial perfusion SPECT or attenuation corrected SPECT can be used to improve specificity in the diagnosis of coronary artery disease. We investigated in this study whether gating or attenuation correction improved diagnostic performance of rest/stress perfusion SPECT in patients having intermediate pre-test likelihood of coronary artery disease. Materials and Methods: Sixty-eight patients underwent rest attenuation-corrected T1-20l/dipyridamole stress gated attenuation-corrected Tc-99m -MIBI SPECT using an ADAC vertex camera (M:F=29:39, aged $59{\pm}12$ years, coronary artery stenosis ${\geq}70%$, one vessel: 13, two vessel: 18, three vessel: 8, normal: 29). Using a five-point scale, three physicians graded the post-test likelihood of coronary artery disease for each arterial territory (1:normal, 2: possibly normal, 3:equivocal, 4. possibly abnormal, 5: abnormal). Sensitivity, specificity and area under receiver-operating-characteristic curves were compared for each operator between three methods : (A) non-attenuation-corrected SPECT; (B) gated SPECT added to (A): and (C) attenuation-corrected SPECT added to (B). Results: When grade 3 was used as the criteria for coronary artery disease, no differences in sensitivity and specificity were found between the three methods for each operator. Areas under receiver-operating-characteristic curves for diagnosis of coronary artery disease revealed no differences between each modality (p>0.05). Conclusion: In patients at intermediate risk of coronary artery disease, gated SPECT and attenuation- corrected SPECT did not improve diagnostic performance.

  • PDF

Study on the Usefulness of Using Anterior and Posterior Views for Calculation of Total Relative Uptake Ratio in 99mTc-DMSA Renal Scan (99mTc-DMSA 검사에서 상대 신섭취율 산출 시 양면상 촬영의 유용성에 대한 고찰)

  • Kim, Joo-Yeon;Lee, Han-Wool;Kwon, O-Jun;Kim, Jung-Yul;Park, Min-Soo;Cho, Seok-Won;Kang, Chun-Goo;Kim, Jae-Sam
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.19 no.1
    • /
    • pp.37-43
    • /
    • 2015
  • Purpose $^{99m}Tc-DMSA$ renal scintigraphy serves as location, size and shape of kidney, so it has been used for diagnosis and passage observation after the operation or treatment. There are 3 methods of calculating the relative renal uptake ratio such as geometric mean of the counts from the anterior and posterior views, arithmetical mean from the only posterior view and posterior view which applied the renal depths. In this study, we seek to correlation between the change of total relative uptake ratio according to different inspection methods of obtaining the renal count rate. Materials and Methods The phantom experiments proceeded 5 times depending on each renal depth with the kidney phantom and tissue equivalent materials. In the clinical research, we investigated 36 adult patients who had visited our hospital from february to october, 2014 and received $^{99m}Tc-DMSA$ renal scan. The equipment was used as a gamma camera named INFINIA (General Electric Healthcare, milwaukee, USA) and we drew the region of interests through semiautomatic method by using Xeleris Ver. 2.1220 of GE. In addition, we obtained the lateral view of kidney to measure the renal depth of each patient. Then the results were compared with 3 methods of calculating relative renal uptake ratio. Results The phantom studies show when the difference between the left ant right kidney depth were less than 1 cm, there were no statistically significant difference among values calculated through anterior and posterior views and only posterior view (P>0.05), while the excess of 1cm, the results showed a statistically significant change in the value (P<0.05). In case of clinical research, the correlation between total relative uptake ratio by obtaining both sides of image and posterior view applied the kidney depth (r=0.999) was higher than by obtaining only posterior view and applying the kidney depth to one side image (r=0.988). Conclusion This study has found that, the difference of calculating total relative uptake ratio compared with obtaining anterior and posterior views and only posterior view. In order to reduce the error, we recommend the method of obtaining anterior and posterior views and is considered to be useful, particularly the patients have similar uptake ratio of left and right kidney and difficulties of measurements of kidney depth.

  • PDF

Comparison of the effect of removing artificial dental plaque depending on various interdental cleaning products on the interdental surface of zirconia crowns (치간 세정 용품에 따른 지르코니아 크라운 인접면의 인공 치면 세균막 제거 효과)

  • Kim, Hyun-Wook;Song, Ha-Kyung;Park, Eun-Jin
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.59 no.3
    • /
    • pp.291-298
    • /
    • 2021
  • Purpose. The purpose of this study is to compare five interdental cleansing products' effectiveness on removing artificial dental plaque on the interdental space of zirconia crowns. Materials and methods. A model with abutments on the right mandibular second premolar and first molar were prepared. 10 zirconia crowns for each abutment were fabricated. After applying artificial dental plaque between the zirconia crowns, a single clinician attempted to remove the plaque with five products: interdental toothbrush, end-tuft toothbrush, dental floss, Easypick, Water pik. They were conducted 10 times per group. The aspect and area of removed surfaces were analyzed using images taken with a digital camera. One factor analysis of variance was performed as a statistical analysis, and a post-hoc test was performed using the Scheffé method (P < .05). Results. There were differences in the area and the pattern according to the characteristics of the products. The largest area, including the marginal portion, was removed in the dental floss group. Interdental toothbrush group was the most effective in removing the dental plaque at the marginal portion. Easypick was less effective than the interdental toothbrush. The end-tuft toothbrush showed better results than other products in cleansing mesiobuccal and distobuccal area, but could not cleanse the area directly below the contact point. In Water pik group, artificial dental plaque was scarcely removed. The removal rate of artificial dental plaque was in the order of floss (69.47%), end-tuft toothbrush (49.36%), interdental toothbrush (44.20%), Easy pick (13.04%), and Water pik (0.59%). Conclusion. Dental floss showed the highest removal rate in the interdental space restored with zirconia crowns, while interdental toothbrush was the most effective in removing the dental plaque at the marginal portion.

A Study On The Identity Of Yeonsegeuk(Kino-Drama) (연쇄극의 정체성 논의 - 총체예술론적 관점에서 -)

  • Kim, Sunam
    • (The) Research of the performance art and culture
    • /
    • no.25
    • /
    • pp.5-30
    • /
    • 2012
  • I. Identity of Yeonsegeuk as total arts. The purpose of the thesis is to arrange the identy of Yeonsegeuk(Kino-Drama) which is theatre or film. The process of study is tried to discuss on the aethetic of Yeonsegeuk. II. Appearance of Yeonsegeuk and negative disputation of yeonsegeuk The first imported Yeonsegeuk from Japanese in Korea is made by the group of Mizuno Ganggetsu(水野觀月) on Oct. 16. 1915 at Pusan and also to run in Seoul at Hwanggeumgwan. The first of Korean Yeonsegeuk is by Kim, Dosan, a leader of Singeukjwa(theare group) on Oct. 27. 1919 at Danseongsa. Before the liberation of Korea from Japan all made korean Yeonsegeuk are 28 works. III. Dramatic form of Yeonsegeuk I study on the relation between Yeonsegeuik and Sinpageuik(new theatre of modern drama in 1920's). I find that Yeonsegeuik admitted the thechnics of the Sinpageuik and the contents. If We think that the theatre is synthetic art which genealize all arts, we can insist that the Yeonsegeuk is valued the total art as new performance to comply with film art to theatre. Conclusionly Yeonsegeuk is called 'Expanded Theatre' as the new performance which must be dicussed in the view of total art. VI. Discussion on the the aethetic of Yeonsegeuk When we compare the structure of film with the structure of theatre, we can't find a diffrent element between the structure of two art in art semiotic. But we find a fact that film art has special elements in mechanics character which are camera working and motage. These technics influence on the audience's mind. It is different point between Japan and Korean's Kino-drama and Germany's that is to admit the aethetic of total art or not. V. Yeonsegeuk as new performance During Korean modern times Kino-drama was first a kind of total art with stage and screen. But it is regretable that Kino-drama didn't have the background of theory which discourse on the comprehension of total art. As the result Kino-drama bring the confusion of argument that Kino-drama is total art or expanded theatre. This confusion will be disputed on film art as performing arts or future art as expanded film and total art.

A study on inspection methods for waste treatment facilities(II): Derivation of problems and improvement direction in inspection methods (폐기물처리시설의 세부검사방법 마련연구(II): 세부검사방법 문제점도출 및 개선방향 설정)

  • Pul-Eip Lee;Eunhye Kwon;Jun-Ik Son;Jun-Gu Kang;Taewan Jeon;Dong-Jin Lee
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.31 no.1
    • /
    • pp.85-100
    • /
    • 2023
  • In this study, in order to improve the installation periodical inspection method of waste treatment facilities, we conducted on-site surveys of waste treatment facilities classified into six fields, grasped the problems of inspection methods, and made improvements accordingly. And revised the inspection method for waste treatment facilities. As a result, in the field of incineration and incineration heat recovery, inspection methods such as total temperature measurement and one-year TMS data comparison using a thermal imaging camera were established. And for the safety of the inspected person, it was applied so that the waste can be replaced with a document without opening it. In the case of landfill facilities, the details regarding the use of video information processing equipment and the management of facilities covering the upper part of the landfill facility are presented in the law, but the items that do not have a inspection methods were applied to the inspection method. In the case of Food Waste Treatment Facility, inspection methods were put in place to ensure compliance with standards for foul-smelling fish in odor control, a major cause of complaints. As a result, 10 out of 18 improvement proposals were reflected in the incineration and sterilization grinding, cement kiln, and incineration heat recovery facilities, and 11 out of 12 improvement proposals were reflected in the landfill facility. In the case of food distribution waste treatment facilities, 10 out of 12 improvement proposals were reflected, and a total of 31 inspection methods were improved.

Mobile Camera-Based Positioning Method by Applying Landmark Corner Extraction (랜드마크 코너 추출을 적용한 모바일 카메라 기반 위치결정 기법)

  • Yoo Jin Lee;Wansang Yoon;Sooahm Rhee
    • Korean Journal of Remote Sensing
    • /
    • v.39 no.6_1
    • /
    • pp.1309-1320
    • /
    • 2023
  • The technological development and popularization of mobile devices have developed so that users can check their location anywhere and use the Internet. However, in the case of indoors, the Internet can be used smoothly, but the global positioning system (GPS) function is difficult to use. There is an increasing need to provide real-time location information in shaded areas where GPS is not received, such as department stores, museums, conference halls, schools, and tunnels, which are indoor public places. Accordingly, research on the recent indoor positioning technology based on light detection and ranging (LiDAR) equipment is increasing to build a landmark database. Focusing on the accessibility of building a landmark database, this study attempted to develop a technique for estimating the user's location by using a single image taken of a landmark based on a mobile device and the landmark database information constructed in advance. First, a landmark database was constructed. In order to estimate the user's location only with the mobile image photographing the landmark, it is essential to detect the landmark from the mobile image, and to acquire the ground coordinates of the points with fixed characteristics from the detected landmark. In the second step, by applying the bag of words (BoW) image search technology, the landmark photographed by the mobile image among the landmark database was searched up to a similar 4th place. In the third step, one of the four candidate landmarks searched through the scale invariant feature transform (SIFT) feature point extraction technique and Homography random sample consensus(RANSAC) was selected, and at this time, filtering was performed once more based on the number of matching points through threshold setting. In the fourth step, the landmark image was projected onto the mobile image through the Homography matrix between the corresponding landmark and the mobile image to detect the area of the landmark and the corner. Finally, the user's location was estimated through the location estimation technique. As a result of analyzing the performance of the technology, the landmark search performance was measured to be about 86%. As a result of comparing the location estimation result with the user's actual ground coordinate, it was confirmed that it had a horizontal location accuracy of about 0.56 m, and it was confirmed that the user's location could be estimated with a mobile image by constructing a landmark database without separate expensive equipment.

The Quantitative Assessment of Renal Function and Size by Differences of Acquisition Counts in $^{99m}Tc$-DMSA Renal Scan ($^{99m}Tc$-DMSA 신장검사에서 획득 계수의 차이에 따른 기능 및 형태 평가)

  • Shim, Dong-Oh;Kim, Ho-Sung;Chung, Eun-Mi
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.117-121
    • /
    • 2010
  • Purpose: In nuclear medicine study, there are two methods, preset count method and preset time method, to acquire static images. We usually use preset count method for static image in $^{99m}Tc$-DMSA renal scan, but occasionally use preset time method. In case of using preset count method, we always acquire same counts but it causes a difference of scan time. In case of using preset time method, it takes same scan time to acquire images but it causes different counts. Therefore, the purpose of this study is to investigate any differences of function and formal information in both kidney by acquisition counts Materials and Methods: From January 11, 2010 to March 31, 2010, we analyzed the 30 patients (M: 11, W: 19). who were examined by $^{99m}Tc$-DMSA scan and have one side of functioning kidney relatively between 40~60%. And the patients who have cold and hot region in image were analyzed but we did not accept images of patients when it was hard to divide kidney into cortex. There was no division between subjects and age of subjects is $14.83{\pm}22.07$ old. We used the BrightView gamma camera from PHILIPS. To analyze function and formal of kidney, we used JET stream release 3.0 version from PHILIPS. Using SPSS 12.0 program, we compared descriptive statistics and paired T-test. Images were acquired sequentially in the same parameters, but there are three methods which different from acquisition time and scan time, 100 kcounts, 300 kcounts and 7 minutes method (exceed 300 kcounts). To assess function and formal information of kidney, we measured renal relative function, geometric mean and size of kidney and analyzed each difference. Results: In case of renal relative function in both kidney, 100 kcounts method was $50.52{\pm}3.64%$. 300 kcounts method was $50.38{\pm}3.66%$ and 7 minutes method was $49.91{\pm}3.40%$ and there were no statistical significant differences between each method. In case of geometric mean, 100 kcounts method was $50.08{\pm}3.25%$. 300 kcounts method was $49.89{\pm}3.40%$ and 7 minutes method was $49.91{\pm}3.24%$. And also, there were no statistical significant differences. When comparing size of kidney, 100 kcounts method was $8.23{\pm}1.96$ cm. 300 kcounts method was $8.12{\pm}1.90$ cm and 7 minutes method was $8.35{\pm}1.97$ cm. In case of right kidney, 100 kcounts method was $7.91{\pm}1.88$ cm. 300 kcounts method was $8.12{\pm}1.90$ cm and 7 minutes method was $8.25{\pm}1.96$ cm. From those values, we recognized that there were significant differences each method (p<0.05). Conclusion: From results of this study, there were no statistical differences in renal relative function and geometric mean by acquisition counts. However, in shape of kidney, the more acquisition counts are increasing, the more size of kidney is getting big. And there were statistical significant differences. Therefore, to perform reliable quantitative result, preset count method is more desirable than preset time method. Especially, in case of a follow-up test, if we use preset time method, it will cause differences of formal results in kidney due to acquisition counts each time we examine patients.

  • PDF

APICAL FITNESS OF NON-STANDARDIZED GUTTA-PERCHA CONES IN SIMULATED ROOT CANALS PREPARED WITH ROTARY ROOT CANAL INSTRUMENTS (전동화일로 형성된 근관에서 비표준화 Gutta-percha Cone의 적합성)

  • Kwon, O-Sang;Kim, Sung-Kyo
    • Restorative Dentistry and Endodontics
    • /
    • v.25 no.3
    • /
    • pp.390-398
    • /
    • 2000
  • The purpose of this study was to evaluate the apical fitness of non-standardized gutta-percha cones in root canals prepared with rotary Ni-Ti root canal instruments of various tapers and apical tip sizes. Simulated sixty curved root canals of plastic blocks were prepared with crown-down technique using rotary root canal instruments of Maillefer ProFile$^{(R)}$ .04 and .06 taper (Maillefer Instrument SA, Switzerland). Specimens were divided into six groups and prepared as follows: Group 1, prepared up to size 25 of .04 taper ; Group 2, prepared up to size 30 of .04 taper ; Group 3, prepared up to size 35 of .04 taper ; Group 4, prepared up to size 25 of .06 taper ; Group 5, prepared up to size 30 of .06 taper ; Group 6 ; prepared up to size 35 of .06 taper. After cutting off the coronal portion of plastic, blocks perpendicular to the long axis of the canal with the use of a diamond saw, apical 5mm of canal space was analyzed. Prepared apical canal spaces were duplicated using rubber base impression material to evaluate two dimensional total area of apical canal space. Various sized gutta-percha cones were applied in the 5mm-apical canal space, which were size 25, size 30 and size 35 standardized gutta-percha cone, Diadent Dia-Pro ISO-.04$^{TM}$ and .06$^{TM}$(Diadent, Korea), and medium-fine (MF), fine (F), fine-medium (FM) and medium (M) sized non-standardized gutta-percha cones (Diadent, Korea). Coronal excess gutta-percha were cut off with a sharp blade. Photographs of impressed apical canal spaces and gutta-percha cones were taken with a CCD camera under a stereomicroscope and stored in a computer. Areas of the total canal space and gutta-percha cones were calculated using a digitalized image analysing program, CompuScope (Sungjin Multimedia Co., Korea). Ratio of apical fitness was obtained by calculating the area of gutta-percha cone to the total area of the canal space. The data were analysed statistically using One-way Analysis of Variance and Duncan's Multiple Range Test. The results were as follows: 1. In canals prepared up to size 25 ProFile$^{(R)}$ of .04 taper, non-standardized MF and F cones occupied significantly more canal space than Dia-Pro ISO-.04$^{TM}$ or size 25 standardized ones (p<0.05). 2. In canals prepared up to size 30 ProFile$^{(R)}$ of .04 taper, non-standardized F cones occupied significantly more canal space than Dia-Pro ISO-.04$^{TM}$ or size 30 standardized ones (p<0.05), and non-standardized MF cones occupied more canal space than size 30 standardized ones (p<0.05). 3. In canals prepared up to size 35 ProFile$^{(R)}$ of .04 taper, there was no significant difference in canal space occupation among non-standardized MF and F, size 35 standardized, and Dia-Pro ISO-.04$^{TM}$ cones (p>0.05). 4. In canals prepared up to size 25 ProFile$^{(R)}$ of .06 taper, non-standardized MF and F cones occupied significantly more canal space than Dia-Pro ISO-.06$^{TM}$, or size 25 standardized ones (p<0.05), and Dia-Pro ISO-.06$^{TM}$, cones occupied significantly more space than size 25 standardized ones (p<0.05). 5. In canals prepared up to size 30 ProFile$^{(R)}$ of .06 taper, non-standardized FM cones occupied significantly more canal space than Dia-Pro ISO-.06$^{TM}$ or size 30 standardized ones (p<0.05), and non-standardized F cones occupied significantly more canal space than size 30 standardized ones (p<0.05). 6. In canals prepared up to size 35 ProFile$^{(R)}$ of .06 taper, non-standardized M and FM, Dia-Pro ISO-.06$^{TM}$ occupied significantly more canal space than size 35 standardized ones (p<0.05). In summary, in both canals prepared with .04 or .06 taper ProFile$^{(R)}$, non-standardized cones showed better fitness than Dia-Pro ISO$^{TM}$ or standardized ones, which was more characteristic in smaller canals.

  • PDF