• 제목/요약/키워드: on-off valves

검색결과 107건 처리시간 0.03초

개폐식 밸브를 사용한 공압 서보 시스템의 효율적 밸브 개폐에 관한 연구 (Study on the Effective Operating Method on-off Valves of Pneumatic Servo System)

  • 황웅태;최서호;이정오
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1996년도 추계학술대회 논문집
    • /
    • pp.820-825
    • /
    • 1996
  • This paper is concerned with effective operating method of pneumatic on-off valves for improving position control accuracy, valve life-time and position settling time using modified pulse width modulation with dead-zone. The pneumatic system using on-off valves studied in this paper has advantage of simple construction and low cost compared with a system with servo-valves. The performance of proposed control system is investigated experimentally for the position control of a pneumatic cylinder using on-off valves. Experimental results show that the proposed algorithm for valve operation can be used to obtain fast and accurate position control and to prevent on-off valves from unnecessary switching.

  • PDF

고속전자밸브를 사용한 유압시스템의 안정성 해석에 관한 연구 (A Study on Stability Analysis of Hydraulic System Using High Speed On-Off Valves)

  • 유태재
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제27권3호
    • /
    • pp.412-420
    • /
    • 2003
  • This study describes the merits of PWM control of hydraulic system using high speed on-off valves. Generally, Electro-hydraulic valves can be classified into two classification: valves which are controlled by analog signal and which are controlled by digital. The former includes hydraulic servo valves and proportional valves which require A/D converters as interface to digital computer and too costly and sensitive to oil contamination because of complexity in structures. The latter includes high speed on-off valves which do not require A/D converters because they are normally operated in a pulse width modulation(PWM) method, and are low in price and robust to oil contamination because of their simple structures. The objectives of this study is to analyze the limit cycle which regularly appear in the position control system using 2/2way high speed on-off valves and to give a criterion for the stability of this system. The nonlinear characteristics of PWM and cylinder friction of this system are described by harmonic linearization and the effects of parameter variations to the system stability are simulated.

친환경 온/오프 다이어프램 밸브 개발 (Development of Eco-Environmental On/Off Diaphragm Valve)

  • 정선환;최성대;김신호
    • 한국기계가공학회지
    • /
    • 제6권4호
    • /
    • pp.28-35
    • /
    • 2007
  • Currently, most of all valves using at the semiconductor & LCD manufacturing process are packless type. Such valves are needed to have the functions to protect perfectly from the leakage of fluid by using bellows and diaphragm instead of the grand packing. But not only those valves made in Korea are not available at this point, but also advanced foreign manufacturers do not open enough their data on the basic technology. Otherwise although they open the data a little, they are almost data about stainless steel for pneumatic valves. In this paper, it was focused on the fluid valves for chemical & DI water based on the data of steel valves which are already using commercially. And also this study concentrated to collect the basic developing data of Eco-On/Off diaphragm valve by ourselves.

  • PDF

개폐식 밸브를 사용한 공기압 서보 시스템의 효율적 밸브 개폐 방법에 관한 연구 (Study on the Effective Operating Method of on-off Valves for a Pneumatic Servo System)

  • 황웅태;최서호;이정오
    • 한국정밀공학회지
    • /
    • 제15권1호
    • /
    • pp.109-116
    • /
    • 1998
  • This paper is concerned with effective operating method of pneumatic on-off valves for improving position control accuracy, valve life-time and position settling time using modified pulse width modulation with dead-zone (MPWMD). The pneumatic system using on-off valves has advantage of simple construction and low cost compared with a system with servo-valves. The performance of the proposed control method is investigated experimentally for the position control of a pneumatic cylinder using on-off valves. Experimental results show that the proposed algorithm for valve operation can be used to obtain fast and accurate position control compared to the conventional PWMD algorithm. It is also shown that the use of the proposed MPWMD algorithm for the position control significantly reduces the number of valve switching and noise.

  • PDF

고속전자밸브를 사용한 전기유압서보시스템의 위치제어에 관한 연구 (A Study on Position Control of an Electro-Hydraulic Servo System Using High Speed On-Off Valves)

  • 허준영
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제23권3호
    • /
    • pp.369-378
    • /
    • 1999
  • This paper presents position control of an electro-hydraulic servo system whoch is operated by four 2-2way high speed on-off valves with either PWM PID control method or sliding mode control method, The advantages of using high speed on-off valves instead of electo-hydraulic servo valves or electro-hydraulic proportional valves are low price robustness for oil contamination and direct control without a D/A converter. The system consists of load cylinder inertia car potentiometer and external load cylinder. The experiments were carried out under several conditions and the results were compared. As a result the sliding mode method has shown good control performance and the robust and stable positioning of the elector-hydraulic servo system can be achieved accurately.

  • PDF

PWM 제어 고속 온-오프 전자밸브에서 발생하는 압력맥동 저감 (Pressure Ripple Reduction in High Speed On-Off Solenoid Valves Driven by PWM Control)

  • 김도태;이상권
    • 유공압시스템학회논문집
    • /
    • 제2권2호
    • /
    • pp.8-13
    • /
    • 2005
  • This paper investigates a fast, accurate and inexpensive hydraulic motor speed control system using high speed on-off solenoid valves. In order to retain the advantages of the two position valve and obtain better performance, the valves are operated by pulse width modulation(PWM) control. PWM signal is generated from a LabWIEW program in microcomputer in order to set up various duty ratio and frequency of carrier wave in PWM signal with varying system parameters. As the results of experiments, the speed control of a hydraulic motor was successfully implemented using on-off solenoid valves. In order to attenuate the pressure ripple and speed variation due to discontinuously controlled flow through the on-off valves, a resonator hose fabricated for automobile power steering system was connected between the valve and a hydraulic motor. From experimental results obtained in the hydraulic motor system with a resonator hose, it was ascertained that the resonator hose showed excellent performances in reducing pressure ripple and motor speed variation.

  • PDF

Micro On-Off Valve 해석에 의한 최적 설계 (The optimal design by Micro On-Off Valve analysis)

  • 김동수;박상운;고창섭
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2005년도 추계학술대회 논문집
    • /
    • pp.285-290
    • /
    • 2005
  • Micro On-Off valves are currently recognized as the core technology in the fields of the micro fluid chip fur medical applications and production lines of semi-conduct chip. Micro valves that operate by compressed air need the high-speed responsibility, repeatability, the absorbability and the uniform pressure by the poppet. In this study, Micro On-Off valves that posses the high-speed responsibility and the high rate of flow have designed and analyzed through the law of equivalent magnetic circuit and Finite Element Method (FEM) respectively. In case of poppet, Flow field characteristic was analyzed by the variation of poppet and it was able to display flow field by changing the location of the poppet. Also, we verified possibility of the design through the static and dynamic pressure and the 3D distribution curve of the force by working the front poppet.

  • PDF

CNG 충전소 배관시스템용 고압 차단밸브에 대한 내부 유동해석에 관한 연구 (A Study on the Internal Flow Analysis of High-pressure Shut-off Valve for CNG Charging Station Piping System)

  • 진도훈
    • 한국산업융합학회 논문집
    • /
    • 제24권6_2호
    • /
    • pp.773-779
    • /
    • 2021
  • CNG, which has recently been attracting attention as an alternative fuel in the transportation field to reduce emissions caused by global warming, is natural gas with abundant reserves and mainly composed of methane. Being in a gaseous state, natural gas requires the compression and liquefaction processes for transportation. Until now, general shut-off valves for liquid and gas piping have been developed in Korea, but there are few studies on shut-off valves for high pressures of about 200 bar. Currently, research on the flow analysis of valves is being actively conducted around the world. However, there are relatively many studies on large valves such as low-pressure valves or shipbuilding and marine, and the safety factor through structural analysis to check the structural integrity of the valve is checked at the design stage. Since it is necessary to have a fast response speed while minimizing pressure and speed loss due to flow change, basic research was conducted on the flow analysis of the valve to secure design data, and the numerical analysis was performed on high-pressure automatic shut-off valves applied to CNG refueling stations. After securing the basic valve shape through reverse engineering for advanced products, we compared the valve flow coefficient Cv coefficient with advanced products. As a result, it was found that the reverse engineering model was at the level of about 60%. However, we compared the Cv coefficient by modifying the reverse engineering model, and the result showed that it was improved to about 96%.

급수기구 발생음의 실험실 측정방법 제2부 : 수도꼭지와 혼합꼭지의 부착방법 및 작동조건 (Laboratory tests on noise emission from appliances and equipment used in water supply installations Part 2: Mounting and operating conditions for draw-off taps and mixing valves)

  • 정갑철;양관섭;김선우
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2003년도 추계학술대회논문집
    • /
    • pp.861-863
    • /
    • 2003
  • The method of measurement for laboratory tests on noise emission from appliances and equipment used in water supply installations is specified in ISO 3822-1. This part of standard gives detailed descriptions for mounting and operating draw-off taps and mixing valves in such laboratory test. Draw-off taps and mixing valves are the most common kind of appliance used in water supply installations.

  • PDF

온수분배기용 유량제어밸브의 개발 (Development of Flow Control Valves for Hot Water Distribution Manifolds)

  • 권우철;윤준용;유선학
    • 한국유체기계학회 논문집
    • /
    • 제13권4호
    • /
    • pp.11-17
    • /
    • 2010
  • The developed control valves, installed on the hot water distribution manifolds for the floor heating system, consist of the balancing valves and the shut-off valves. The balancing valve was designed to improve the flow control performance and to reduce the noise emitted from the valve by modification of the general V port. The port of the shut-off valve was designed with two ceramic plates, working by rotating upper plate, to improve the duration and to reduce the noise. For the evaluation of the new valves, the flow rate was measured and noise level test was carried out. The test results showed that the error of the flow rate accuracy test for the flow balance of each manifold circuit was less than ${\pm}3%$ and the noise level was less than 35 dB(A).