• Title/Summary/Keyword: on-off control

Search Result 2,536, Processing Time 0.032 seconds

ANALYSIS OF HUMAN DECISION MAKING PROCESS BASED ON CONDITIONAL PROBABLILTY

  • Nakamura, Masatoshi;Goto, Satoru
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1997.10a
    • /
    • pp.783-786
    • /
    • 1997
  • Automatic realization of on-off human decision making was derived based on a conditional probability. Following the proposed procedure, problems of insulator washing timing in power substations and spike detection on EEG(electroencephalogram) records were appropriately solved.

  • PDF

A Development of Monitoring System for Automatic Environmental Control (자동 환경 제어 모니터링 시스템 개발)

  • 김대업;엄현서;정광하;박흥복
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.5 no.3
    • /
    • pp.503-516
    • /
    • 2001
  • At present, environmental control system of greenhouses related with industrial automation in the korea is composed of on/off-type control machine using a timer in facilities requiring intensive labor. This system, however, makes it difficult for us to find out any status of environmental control system in greenhouses when we are situated in a remote area or at midnight. In this paper we improved a system to monitor status for manual and automatic control by means of PC by replacing an existing on/off-type controller with a display panel, It also attempts to implement DB for information on corps and to provide a user with the efficiency of getting information for plants.

  • PDF

Ground Experiment of Spacecraft Attitude Control Using Hardware Testbed

  • Oh, Choong-Suk;Bang, Hyo-Choong
    • International Journal of Aeronautical and Space Sciences
    • /
    • v.4 no.1
    • /
    • pp.75-87
    • /
    • 2003
  • The primary objective of this study is to demonstrate ground-based experiment for the attitude control of spacecraft. A two-axis rotational simulator with a flexible ann is constructed with on-off air thrusters as actuators. The simulator is also equipped with payload pointing capability by simultaneous thruster and DC servo motor actuation. The azimuth angle is controlled by on-off thruster command while the payload elevation angle is controlled by a servo-motor. A thruster modulation technique PWM(Pulse Width Modulation) employing a time-optimal switching function plus integral error control is proposed. An optical camera is used for the purpose of pointing as well as on-board rate sensor calibration. Attitude control performance based upon the new closed-loop control law is demonstrated by ground experiment. The modified switching function turns out to be effective with improved pointing performance under external disturbance. The rate sensor calibration technique by Kalman Filter algorithm led to reduction of attitude error caused by the bias in the rate sensor output.

Design Consideration for Structure of 2500-4500V RC-GCT

  • Kim E. D.;Kim S. C.;Zhang C. L.;Kim N. K.;Bai J. B.;Li J. H.;Lu J. Q.
    • Proceedings of the KIPE Conference
    • /
    • 2001.10a
    • /
    • pp.36-38
    • /
    • 2001
  • A basic structure of 2500V-4500V reverse-conducting GCT (RC-GCT) is given in this paper. The punch-through type (PT) is adopted for narrow N-base with high resistivity so that the fast turn-off and low on-state voltage can be achieved. The photo mask design was made upon the both turn-off performance and solution of separation between GCT and integrated freewheeling diode (FWD) part. The turn-on and turn-off characteristics for reserve-conducting gate commutated thyristors (RC-GCTs) were investigated by ISE simulation. Additionally, the local carrier lifetime control by proton irradiation was adopted so as not only to obtain the reduction of turn-off losses of GCT but also to reach a soft reverse recovering characteristics of FWD

  • PDF

Parametric Study of Engine Operating Conditions Affecting on Catalytic Converter Temperature (엔진 문전 조건이 촉매 온도에 미치는 영향)

  • 이석환;배충식;이용표;한태식
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.10 no.3
    • /
    • pp.61-69
    • /
    • 2002
  • To meet stringent LEV and ULEV emission standards, a considerable amount of development work was necessary to ensure suitable efficiency and durability of catalyst systems. The main challenge is to cut off the engine cold-start emissions. It is known that up to 80% of the total hydrocarbons(THC) are exhausted within the first five minutes in case of US FTP 75 cycle. Close-Coupled Catalyst(CCC) provides fast light-off temperature by utilizing the energy in the exhaust gas. However, if some malfunction occurred at engine operation and the catalyst temperature exceeds 1050$\^{C}$, the catalytic converter is deactivated and shows the poor conversion efficiency. This paper presents effEcts of engine operating conditions on catalytic converter temperature in a SI engine, which are the indications of catalytic deactivation. Exhaust gas temperature and catalyst temperature were measured as a function of air/fuel ratio, ignition timing and misfire rates. Additionally, light-off time was measured to investigate the effect of operating conditions. It was found that ignition retard and misfire can result in the deactivation of the catalytic converter, which eventually leads the drastic thermal aging of the converter. Significant reduction in light-off time can be achieved with proper control of ignition retard and misfire, which can reduce cold-start HC emissions as well.

A Study on the Position Control and Simulation of Pneumatic Servo System (공기압 서보 시스템의 위치 제어 및 시뮬레이션에 관한 연구)

  • Choi, Seo-Ho;Hong, Yeh-Sun;Lee, Chung-Oh
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.13 no.6
    • /
    • pp.102-113
    • /
    • 1996
  • An experimental and theoretical study on a pneumatic servo system has been conducted using on-off valves and a pneumatic cylinder. A V/I converter has been designed for rapid rising and falling of the solenoid current, which significantly improves the positioning accuracy and settling time of the servo system by shortening the valve opening time. Pulse width modulation was modified to operate on-off valves effectively. A state feedback controller which feeds back position, velocity and acceleration is used to control the system. The influence of controller gains on the system performance is studied to develop a scheme that automatically adjusts the gains using fuzzy logic theory. It is shown experimentally that the proposed fuzzy logic tuner works satisfactorily. A new method for measurements of valve effective areas is proposed, and a partially polytropic model is applied to simulation of the pneumatic system. Simulated results show good agreement with experimental data.

  • PDF

Biological Control of Pythium Damping-off of Bush Okra Using Rhizosphere Strains of Pseudomonas fluorescens

  • Abdelzaher, Hani M.A.;Imam, M.M.;Shoulkamy, M.A.;Gherbawy, Y.M.A.
    • Mycobiology
    • /
    • v.32 no.3
    • /
    • pp.139-147
    • /
    • 2004
  • A severe damping-off disease of bush okra caused by Pythium aphanidermatum, was diagnosed in plastic houses in Der Attia village, 15 km southwest of El-Minia city, Egypt, during the winter of 2001. Bush okra seedlings showed low emergence with bare patches inside the plastic houses. Seedlings that escaped pre-emergence damping-off showed poor growth, stunting and eventually collapsed. Examination of the infected tissues confirmed only Pythium aphanidermatum, showing its typical intercalary antheridia, and lobulate zoosporangia. P. aphanidermatum was shown to be pathogenic on bush okra under pot and field experiments. Bacteria making inhibition zones against the damping-off fungus P. aphanidermatum were selected. Agar discs from rhizosphere soil of bush okra containing colonies were transferred onto agar plate culture of P. aphanidermatum. After 2 days of incubation, colonies producing clear zones of non-Pythium growth were readily detected. The two bacteria with the largest inhibition zones were identified as Pseudomonas fluorescens. Bush okra emergence(%) in both pot and plastic houses experiments indicated that disease control could be obtained by applying P. fluorescens to the soil or coating the bacteria to the bush okra seeds before sowing. In the plastic houses, application of the bacteria onto Pythium-infested soil and sowing bush okra seeds dressed with bacteria gave 100% emergence. In addition, This was the first reported disease of bush okra by this oomycete in Egypt.

Slices Analysis Method of Petri nets in FMS Using the Transitive Matrix

  • Kim, Jung-Won;Lee, Jong-Kun;Song, Yu-Jin;Kim, Jong-Wook
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2001.10a
    • /
    • pp.132.3-132
    • /
    • 2001
  • In this paper, we focus on the analysis of the scheduling problem in FMS after slicing off some sub-nets using the transitive matrix. This class of Time Petri nets is obtained by merging subnets based on the machine's operations. We can divide original system into some subnets based on machine's operations using Time Petri nets slice and analyze the feasibility time in each schedules. In this paper, we show the usefulness of transitive matrix to slice off some subnets from the original net, and explain on an example.

  • PDF

Performance Investigation of Variable Damping Shock Attenuation Logic (가변 감쇠를 이용한 충격제어기법의 성능분석)

  • Oh, Hyun-Ung
    • Journal of Aerospace System Engineering
    • /
    • v.7 no.1
    • /
    • pp.1-7
    • /
    • 2013
  • Launch vehicles cause several shock events during their lift-off. The excessive shock loads in the several thousands of g's level can results in permanent damage to electronics, optics and other sensitive payload components. The shock can be attenuated by mounting a shock absorber. In this paper, we proposed a semi-active control logic to attenuate the shock so that the input acceleration to main instruments does not exceed the allowable maximum acceleration value. For the performance investigation, two elements model of variable damping and spring stiffness has been used and the analysis results indicate that the proposed semi-active control logic attenuates shock level better than an optimal passive and conventional semi-active on-off control system.

Development of Flow Control Valves for Hot Water Distribution Manifolds (온수분배기용 유량제어밸브의 개발)

  • Kwon, Woo-Chul;Yoon, Joon-Yong;Yoo, Sun-Hak
    • The KSFM Journal of Fluid Machinery
    • /
    • v.13 no.4
    • /
    • pp.11-17
    • /
    • 2010
  • The developed control valves, installed on the hot water distribution manifolds for the floor heating system, consist of the balancing valves and the shut-off valves. The balancing valve was designed to improve the flow control performance and to reduce the noise emitted from the valve by modification of the general V port. The port of the shut-off valve was designed with two ceramic plates, working by rotating upper plate, to improve the duration and to reduce the noise. For the evaluation of the new valves, the flow rate was measured and noise level test was carried out. The test results showed that the error of the flow rate accuracy test for the flow balance of each manifold circuit was less than ${\pm}3%$ and the noise level was less than 35 dB(A).