• Title/Summary/Keyword: on-line analysis

Search Result 7,874, Processing Time 0.037 seconds

The Effects of Line Dance Program on Muscle Strength, Balance, Flexibility, Pain, and Mood State in Post-menopausal Women (라인댄스가 폐경 이후 여성의 근력, 균형감, 유연성, 통증 및 기분상태에 미치는 효과)

  • Cho, Kyung Sook;Choi, Hee Kwon;Nam, Hye Kyung
    • Journal of muscle and joint health
    • /
    • v.19 no.3
    • /
    • pp.263-271
    • /
    • 2012
  • Purpose: The purpose of this study was to examine the effects of line dance program on muscle strength, balance, flexibility, pain, and mood state in post-menopausal women. Methods: A quasi-experimental research design (one group pretest-posttest) was employed. A total of 13 post-menopausal women completed 12-week line dance program(60min/day, 2days/wk) in S city. Descriptive statistics, Wilcoxon signed rank test were used in the data analysis by SPSS 18.0. Results: Muscle strength and balance were higher, and pain level were lower than before the line dance program. However, flexibility and mood state were not significantly changed after the line dance program. Conclusion: Findings of this study indicated that the 12-week line dance program were effective on muscle strength, balance, and pain relief in the post-menopausal women. Future study is needed to explore the effect of the line dance program on flexibility and mood state with the post-menopausal women.

Transient Analysis and Evaluation of 345kV Combined Transmission Line Connected with GIL (345kV급 GIL이 연계된 혼합송전선로의 뇌서지해석 및 평가)

  • Jang, Hwa-Youn;Lee, Jong-Beom;Kim, Yong-Kap;Jung, Chae-Kyun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.11
    • /
    • pp.1949-1955
    • /
    • 2010
  • This paper describes the characteristic and effectiveness of combined GIL transmission line through lightning surge analysis. In addition the XLPE cable is analyzed in the same condition to compare with GIL. Lighting surge analysis is carried out by EMTP/ATP-Draw to obtain overvoltage of GIL and XLPE cable at service-point and load-out area of underground line. Propagation velocity is calculated in combined transmission lines with GIL and XLPE cable. The overvoltage is also analyzed on GIL and XLPE cable with or without arrester operation. The Analysis results show that overvoltage of GIL is occurred higher than XLPE cable at the same condition. Therefore it is evaluated that the application of GIL at the field should be considered cautiously when more detailed transient analysis, another electrical testes and economic evaluations are implemented.

Design and Analysis of an Interleaved Boundary Conduction Mode (BCM) Buck PFC Converter

  • Choi, Hangseok
    • Journal of Power Electronics
    • /
    • v.14 no.4
    • /
    • pp.641-648
    • /
    • 2014
  • This paper presents the design considerations and analysis for an interleaved boundary conduction mode power factor correction buck converter. A thorough analysis of the harmonic content of the AC line current is presented to examine the allowable voltage gain (K value) for meeting the EN61000-3-2, Class D standard while maximizing efficiency. The results of the harmonic analysis are used to derive the required value of K and therefore the output voltage necessary to meet the class D requirements for a given AC line voltage. The discussed design consideration and harmonic current analysis are verified on a 300W universal line experimental prototype converter with an 80V output. The measured efficiencies remain above 96% down to 20% of the full load. The input current harmonics also meet the IEC61000-3-2 (class D) standard.

CFD Analysis on the 2nd Cylinder Discharge line in Hydrogen Reciprocating Compressor

  • Lee, Gyeong-Hwan;Woo, Ju-Sik;Shin, Yong-Han;Jeong, Hyo-Min;Chung, Han-Shik
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.34 no.5
    • /
    • pp.695-702
    • /
    • 2010
  • Numerical analysis information will be very useful to improve fluid system. General information about an internal gas flow is presented by numerical analysis approach. Relating with hydrogen compressing system, which have an important role in hydrogen energy utilization, this should be a useful tool to observe the flow quickly and clearly. Flow characteristic analysis, including pressure and turbulence kinetic energy distribution of hydrogen gas coming to the cylinder of a reciprocating compressor are presented in this paper. Suction-passage model is designed based on real model of hydrogen compressor. Pressure boundary conditions are applied considering the real condition of operating system. The result shows pressure and turbulence kinetic energy are not distributed uniformly along the passage of the Hydrogen system. Path line or particles tracks help to demonstrate flow characteristics inside the passage. The existence of vortices and flow direction can be precisely predicted. Based on this result, the design improvement, such as reducing the varying flow parameters and flow reorientation should be done. Consequently, development of the better hydrogen compressing system will be achieved.

Characteristic Analysis of Line-start Permanent Magnet Synchronous Motor considering Skew Effect (Skew를 고려한 유도기동형 영구자석 동기전동기의 특성 해석)

  • Oh, Young-Jin;Lee, In-Woo
    • Proceedings of the KIEE Conference
    • /
    • 2005.04a
    • /
    • pp.12-14
    • /
    • 2005
  • This study investigates the characteristic analysis of Line-start Permanent Magnet Synchronous Motor considering skew effect. The effects of the skew on machine characteristic are analyzed by using direct co-simulation of Matlab Simulink and Flux2D. Validity of analysis method is confirmed by the analysis result of Non-skew Model.

  • PDF

A Case Study on Use of the Production Innovation Methods for Improving Productivity (생산혁신 기법을 활용한 생산성향상 사례연구)

  • Kim, Kwang Soo;Seo, Chen Beom;Chuhg, Soon Seok
    • Asia-Pacific Journal of Business Venturing and Entrepreneurship
    • /
    • v.8 no.3
    • /
    • pp.147-155
    • /
    • 2013
  • This paper study is for enhance the productivity. The purpose of this study is save the cost and contribute the enhancing company's competitiveness by analysis overall wastes in production line and improve the wastes in production line. Many company does not have clear process for analysis the wastes in production line. so they use classical IE tool and advanced IE tool by considering their current situation but the result was not so effective. The study to arrange the classic IE and advanced IE by each step to analysis the wastes by each production line include assembly line and processing line and automation line so that we can predict the mount of the overall wastes and easily select / focus on the tool for maximize the improvement result. It will contribute to establish the mid term and long term improvement activity plan.

  • PDF

The Design, Manufacture and Applications of a Gap Noise Generator for Testing the Characteristics of EMI from Transmission Lines (송전선로 EMI 특성 실험용 인공잡음발생장치 설계, 제작 및 적용)

  • Ju, Yun-Ro;Yang, Gwang-Ho;Myeong, Seong-Ho;Lee, Dong-Il;Sin, Gu-Yong
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.51 no.1
    • /
    • pp.23-28
    • /
    • 2002
  • In order to survey the radiation characteristics of pure line noise of unwanted noise from overhead high voltage AC transmission lines, a disk type gap noise generator was manufactured. Disk size which decides capacitance between the noise generator and earth was selected through preliminary indoor experiments and analysis by using surface charge method. The capacitance is one of principal parameters related to the injection of a proper noise current into lines. On the basis of the capacitance obtained from calculation, 5mm of space was given to the gap of the noise generator to be installed o test line and an aluminum disk of 60cm radius was made. The field experiments were performed with the noise generator hung on the Kochang 765 kV full scale test line. As the results, the useful data which can be used to analysis the radiation characteristics of noise from transmission lines were obtained. Those are the directivity of antenna toward the line, lateral profiles, frequency spectra, height pattern and so on.

Examining Line-breaks in Korean Language Textbooks: the Promotion of Word Spacing and Reading Skills (한국어 교재의 행 바꾸기 -띄어쓰기와 읽기 능력의 계발 -)

  • Cho, In Jung;Kim, Danbee
    • Journal of Korean language education
    • /
    • v.23 no.1
    • /
    • pp.77-100
    • /
    • 2012
  • This study investigates issues in relation to text segmenting, in particular, line breaks in Korean language textbooks. Research on L1 and L2 reading has shown that readers process texts by chunking (grouping words into phrases or meaningful syntactic units) and, therefore, phrase-cued texts are helpful for readers whose syntactic knowledge has not yet been fully developed. In other words, it would be important for language textbooks to avoid awkward syntactic divisions at the end of a line, in particular, those textbooks for beginners and intermediate level learners. According to our analysis of a number of major Korean language textbooks for beginner-level learners, however, many textbooks were found to display line-breaks of awkward syntactic division. Moreover, some textbooks displayed frequent instances where a single word (or eojeol in the case of Korean) is split between different lines. This can hamper not only learners' learning of the rules of spaces between eojeols in Korean, but also learners' development in automatic word recognition, which is an essential part of reading processes. Based on the findings of our textbook analysis and of existing research on reading, this study suggests ways to overcome awkward line-breaks in Korean language textbooks.

Preliminary Design of mooring line in floating wave energy farm (부유식 파력발전단지 조성을 위한 계류선 초기설계)

  • Jung, DongHo;Song, JaeHa;Shin, SeungHo
    • Journal of Ocean Engineering and Technology
    • /
    • v.27 no.6
    • /
    • pp.16-21
    • /
    • 2013
  • In this paper, the mooring system for a floating wave energy farm is designed based on a two-dimensional analysis. The mooring system uses an anchorless mooring line linking two floaters in a floating wave energy farm. The basic equation to determine the length of the mooring line between the two floaters is proposed. The other properties such as the diameter and pretension are taken from the mooring line for a single floater. The dynamic behavior and safety of the designed mooring system under extreme ocean conditions are analyzed with the commercial software Orcaflex. A numerical study shows the stability and high safety in tension of the designed mooring lines for a floating wave energy farm. The proposed anchorless mooring system for a floating wave energy farm results in a considerable reduction in the length of the mooring line, contributing to the economics of a floating wave energy farm.

The Development Plan of Voltage Security On-Line Monitoring System (전압안전성 온라인 감시시스템의 개발방안)

  • Jeon, D.H.;Kweon, S.G.;An, G.W.
    • Proceedings of the KIEE Conference
    • /
    • 1998.07c
    • /
    • pp.1173-1175
    • /
    • 1998
  • This paper presented the development plan of voltage security on-line monitoring system (VSECOMs). VSECOMs consists of voltage security monitoring system and data management system. VSECOMs has the function of bus voltage watch. voltage stability analysis, and voltage security assessment. EMS data on-line acquisition, PSS/E file conversion, and overall data management. VSECOMs is designed with client/server structure. We will seek stable operation of KEPCO's power system by installation of VSECOMs in EMS of KEPCO.

  • PDF