• Title/Summary/Keyword: old building

Search Result 587, Processing Time 0.025 seconds

Origin and Preservation Status of the 'Gongju Junghakdong Old Missionary House', the Registered Cultural Property No. 233 (등록문화재 제233호 '공주 중학동 구 선교사가옥'의 유래와 보존현황)

  • Suh, Mancheol;Kim, Sung Bae
    • Journal of Conservation Science
    • /
    • v.34 no.1
    • /
    • pp.11-21
    • /
    • 2018
  • The result of the study on the origin and preservation status of the 'Gongju Junghakdong old missionary house', the Registered Cultural Property No. 233, reveals that the building was approved on October 23, 1921, and missionary Alice H. Sharp was living in the building until her retirement from her missionary life of 39 years in Korea in 1939. In order to review internal and external preservation status of the building, condition of wood material, the composition of the window, the damage of the wall, and the leaning of the building were examined. In particular, in the case of window facilities, it is necessary to restore it to the original upper and lower sliding window. As a result of investigation of the preservation status of the external facilities, it is necessary to restore the original shape of the staircase and a deck of the building on south western side and the well. In addition, the results of the non-destructive diagnosis of the ground revealed that the building was built on uneven surface layer of 2-5 m thickness and the boundary between the surface layer and the upper part of the weathered rock is inclined following geomorphology. This phenomenon shows that when the water content of the ground increases in the rainy season, the bearing capacity of the ground is lowered, and there is a possibility of uneven subsidence. Especially, landslides may occur in case of heavy rain. Therefore, it is desirable to install a masonry facility at the southwest boundary of the site, and it is recommended to install a drainage facility to ensure rapid drainage.

A Study on the Unification of the Grounding System of SeoulMetro (서울메트로 접지설비 표준화 방안 연구)

  • Kim, Gyun-Sig;Park, Han-Yeong;Back, Yu-Ho
    • Proceedings of the KSR Conference
    • /
    • 2007.05a
    • /
    • pp.1027-1036
    • /
    • 2007
  • Since the opening of the Seoul Metro in 1974, the electric railway passengers have been increased rapidly and as the advanced equipments(OC,PSD) were introduced, additional power facilities were built in a limited area for the comfortable transportation environment. Present grounding system were built according to old Electric equipment standards and all the electric signal, communication and electronic equipments were built only for the purposes of protecting building structure, people and electronic equipments. Grounding system which was additionally built in the limited area caused problems with the building structure and it caused secondary damages when earth fault happens. One of the problems is grounding system of the building structure; grounding system does not work properly since grounding equipments are not separated from each other. So, existing grounding system needs to be improved and unified grounding system in the building should be established. The purposed of this study is to analyze all the grounding systems that had been built in different year and to establish unified grounding system of Seoul Metro.

  • PDF

A Study on the Actual Condition Analysis and Improvement of Rebar Work in Korean Building Construction (국내 철근공사 실태분석 및 개선방안에 관한 연구)

  • Park, U-Yeol;Kim, Gwang-Hui;Gang, Gyeong-In
    • Journal of the Korea Institute of Building Construction
    • /
    • v.4 no.3
    • /
    • pp.83-91
    • /
    • 2004
  • With labor shortage and high-wage era, the construction cost is rising and the construction business is dull, demanding the construction environment of Korea to raise profitability through major cost savings and rationalization of construction management. However, although reinforcing bar(rebar) work, which greatly effects the building's safety, endurance, and construction time, is an important phase in construction, it holds serious problem of quality and productivity deterioration due to its characteristic of intensive-labor and maintaining of old work methods resulting in poor management, and costs increase. Therefor in this study to investigate current situation and problems of rebar work and to find methods of betterment, a survey was conducted to site engineers and individuals in division of cost estimate of domestic construction company. The survey questions were on the subjects of (1) calculating rebar quantity, (2) ordering and procurement, (3) rebar cutting and bending, and (4) rebar work management. Method of improvement was sought by analyzing the results of the survey

Inactivation of Indoor Airborne Fungi Using Cold Atmospheric Pressure Plasma (저온 대기압 플라즈마의 실내공기 중 곰팡이 생장억제 효과)

  • Paik, Namwon;Heo, Sungmin;Lee, Ilyoung
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.29 no.3
    • /
    • pp.351-357
    • /
    • 2019
  • Objectives: The objectives of this study were to investigate fungal contamination in a 31-year old university building in Seoul, Korea, and to study the inactivation of fungi using cold atmospheric pressure plasma(CAP). Methods: To investigate the fungal contamination in a university building, air samples were collected from five locations in the building, including two study rooms, a storage room, a laboratory, and a basement. The sampling was performed in a dry season(February to April) and in a wet season(July). To study the inactivation efficacy of fungi by CAP, airborne fungal concentrations were measured before and after the operation of the CAP generator. Results: Humidity was an important factor affecting fungal growth. The airborne fungal concentrations determined in the wet season(July) were significantly higher than those determined in the dry season(February to April). In the basement, the values determined in the dry and wet season were 319 and $3,403CFU/m^3$, respectively. The inactivation efficiency of fungi by CAP was 83-90% over five to nine days of operation. Conclusions: The university building was highly contaminated by airborne fungi, especially in summer. It is concluded that humidity is an important factor affecting fungal growth and CAP is a highly useful technique for inactivation of indoor airborne fungi.

An Analysis of the Characteristics of Changes in Carbonation Components by Environmental Exposure in Deteriorated Building Structures (노후 건축물 구조부별 환경 노출에 따른 탄산화 성분 변화 특성 분석)

  • Park, Su-In;Kang, Eun-Song;Son, Byeung-Hun;Lee, Ji-Soo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2021.05a
    • /
    • pp.49-50
    • /
    • 2021
  • However, in the case of concrete, there is a concern that carbonation may proceed due to environmental factors. However, in the case of concrete, there is a concern that carbonation may proceed due to environmental factors. Research is steadily underway to prevent carbonation because carbonation decreases durability and increases the risk from disasters. However, there are many cases in which studies related to carbonation have been conducted only with materials in the same space. Therefore, in this study, FT-IR was used to analyze the difference in carbonation components by structural parts of old buildings. As a result, it was confirmed that there was a difference in peak values for each structural part of the building. The difference in peak values was determined to indicate differences in components, so the level of carbonation progress was different, and it is believed that differentiated repair and reinforcement methods will be needed depending on the structure.

  • PDF

A Study on the Maintenance of the Library of Unified Germany and Its Information Service System (통일독일의 도서관 및 정보서비스체계 정비에 관한 연구)

  • Kim Soon-Won
    • Journal of the Korean Society for Library and Information Science
    • /
    • v.26
    • /
    • pp.235-256
    • /
    • 1994
  • The purpose of this paper is to review concerns and activities related to the library of Germany as well as to look over recent trends referred to the maintenance of the library and its information service system since the unification of Germany in 1990. In fact, since the unification, many libraries in old East Germany have been closed with some precious books being lost. Also since most of libraries are short of funds and proper materials, it is real situation that they can not actively respond to the demand of information by library users who want to adapt themselves to changes, while only urgently requesting some support from old West Germany. In the meantime, the new government and libraries of Germany are giving a great effort to building an efficient document delivery system through financial support for the expansion of books and the purchase of urgently necessary library equipments in the poor libraries of old East Germany and support for the course to re-educate the in-service or unemployeed librarians, and also systematic organization between similar libraries, integration of national bibliographies, and maintenance of the interlibrary loan system. The nationwide interlibrary loan system, an expanded form of the system of old West Germany, allows the delivery of document to be easily performed, centered on both central cataloues for East Germany and West. However, in order to build an efficient information service system which covers whole Germany, it seems there needs more time required.

  • PDF

Studies on the population biology of some clonal plants in a coastal reclaimed land

  • Choung, Yeon-Sook;Joon-Ho Kim
    • The Korean Journal of Ecology
    • /
    • v.14 no.3
    • /
    • pp.327-343
    • /
    • 1991
  • Clonal growth and rhizome architecture of calmagrostis epigeios, were studied in a 15-year old coastal reclamed land. As c. epigeios patch grew from center to margin radially over time, concentric annuli were added. the radial increases of the mature patch were 80~130cm/yr. the patch ages of c. epigeios estimated by relationships between the diameter and is radial increament, were 1~6year old. There were the marked variations of density, phytomass, shoot height and inflorecence frequency with increasing age of rhizome system within the patch. the maximum performance occurred at 2-year-old concentric annuli of the patch. The growth phasic continuum with aging was divided into 5 grwth phases ; pioneer, building, matyre, senile and degenerate. The rhizome aging had a more significant effect on the inflorescence frequency than on the other attributes. new rhizomes tended to diverge from the direction of the parent ramet by sympodial growth. in a 1-year-old patch, average length of rhizome segment was 7cm, average number of internode was 6, and the tillering frequency was 27%. The tillering in the early stage resultd in the increase of shoot density and the producation of multibranching rhizome. as the result of that, circular patchwas formed in a year. The branching structure based on such facts was represented graphically in branching degree of 60 and 100. therefore, c. epigeios with clonal growth may establish and grow vigorously earlier than other glycophytes in high salt conditions such as the coastal reclaimed land.

  • PDF

A Study on Cheongju Townscape in the 1960s through the Restoration Model (1960년대 청주 도심경관고 -도심 복원모델의 제작을 통하여-)

  • Kim, Tai-Young;Oh, Sungjin
    • Journal of the Korean Institute of Rural Architecture
    • /
    • v.20 no.4
    • /
    • pp.19-29
    • /
    • 2018
  • This study examines the 1960s' townscape through the small-scale restoration model in Seongan-dong and Jungang-dong, Cheongju, one of the historical cities in South Korea. In the 1960s, Jungang-dong actively was developed outside the north gate of Cheongju castle, and Cheongju's townscape was changed by the relocation of railway station and construction of city hall. In the streetscape, the new roads, the east-west Sajik-ro and north-south Sangdang-ro were opened instead of old railroads, and they clarified the typical grid road system with the existing Seongan-ro, which connected north and south gate of the old castle. In the buildingscape, city hall was built in front of the railway station outside the north gate of old castle, and had a great effect on the existing buildings and facilities. The public, educational, and commercial buildings had been replaced by reinforced concrete, and the cement brick & block public housing were distributed widely. But the existing dwelling areas, located in the inside of old castle and outside south gate, showed the low and dense townscape, sustaining the former streets and building types.

Improvement plan for 'Newly found ideographs(新出漢字)' in the digitalizing business of the old Korean documents (고전 자료 디지털화사업에서의 신출한자 처리 개선방안)

  • Lee, Jeong-Hwa
    • Korean Journal of Oriental Medicine
    • /
    • v.10 no.1
    • /
    • pp.1-14
    • /
    • 2004
  • As entering the information age of the 21st century, Korea is actively processing many digitalizing businesses related to information source of the Korean academic science at the government level based on the Korean advanced digital technologies, which makes them more evolved through the internet networks in Korea. The definition of 'Newly found ideographs(新出漢字)' are made by researching and extracting from the old Chinese documents through the digitalizing process and they are not registered yet among the block of Unicode & extended Chinese characters those are existent international standard. Presently Korea is in the middle of brisk developing computerized old documents in the huge scale. Meanwhile, the international standard of Chinese characters in mostly Asian countries where using them is processing and developing by IRG. Therefore, Korean processing works is very important which are included extracting precisely 'Newly found ideographs' founded from building its database, organizing as an international standard code, submitting the International organization and finally registering as the best standard code.

  • PDF

Characteristics of Wave Forces by Installation of New Circular Caisson on the Back of Old Circular Caisson (기존 원형케이슨 후면에 신규 원형케이슨 설치에 따른 파력특성 분석)

  • Park, Min Su
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.31 no.6
    • /
    • pp.395-402
    • /
    • 2019
  • In order to increse the stability of old caissons, the design and the construction are performed by installation of new caissons on the back of or on the front of old caissons. In this study, we use the eigenfunction expasnion method to analyze the characteristics of wave forces when new circular caissons are installed on the back of old caissons. The comparison of numerical results between eigenfunction expansion method and ANSYS AQWA is made and the wave force acting on each circular caisson is calculated by considering the wave-structure interaction effect.