• 제목/요약/키워드: oil outlet

검색결과 89건 처리시간 0.023초

A Study on Flow Characteristics of Polluted Air in Rectangular Tunnel Models Using a PIV System

  • Koh, Young-Ha;Park, Sang-Kyoo;Yang, Hei-Cheon;Lee, Yong-Ho
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제34권6호
    • /
    • pp.825-832
    • /
    • 2010
  • The objective of this study is to investigate flow behaviors of polluted air in order to prevent the impact of disaster in a tunnel. This paper presents the experimental results qualitatively in terms of flow characteristics in two kinds of rectangular tunnel models in which each distance from the centerline above the inlet vent to the exhaust vent is 0 and 60 mm, respectively. The olive oil is used as the tracer particles. The flow is tested at the flow rate of $14.16{\times}10^{-4}\;m^3/s$ and the inlet vent velocity of 1.1 m/s with the kinematic viscosity of air. The aspect ratio of the model test section is 10. The average velocity vectors, streamlines, and vorticity distributions are measured and analyzed by the Flow Manager in a particle image velocimetry(PIV) system. The PIV technology gives three different velocity distributions according to observational points of view for understanding the polluted air flow characteristics. The maximum value of mean velocity generally occurs in the inlet and outlet vent regions in the tunnel models.

냉각탑을 이용한 축열식 히트펌프시스템의 성능측정에 관한 연구 (A study on performance test of water heat storage type heat-pump system using cooling tower heat source)

  • 이상훈;박효식;한우용;김욱중
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.1099-1104
    • /
    • 2008
  • Recent year, mean energy consumptions of a people are higher than other country. And international oil price became over 120 dollar. This energy environment as well as energy war. Maybe, the Meteorological Administration is going to enforce scorching heatwave special report system from that come summer. Besides, 2008 summer, maximum demand power is expected by 64,240,000kW. The electric power equipment reserve rate appeared in to keep 12.5% level. Chilled water storage system witch is one of electric load administration system. Heat pump system used cooling tower heat recovery is advantage that use is possible to summer in small a public bath building. In this paper, we suggest that heat pump system by heat recovery using cooling tower when it is heating operation of ambient air temperature. To apply cooling tower heat recovery heat pump to chilled water heat storage type and achieved performance evaluation about operation. As a result, performance of heat pump system that about 121% in cooling mode, 138% in heating mode higher than KEPCO standard. And heating operation possible to ambient air temperature about $23^{\circ}C$, which of appear cooling tower outlet temperature about $13^{\circ}C$.

  • PDF

자동차 엔진냉각계의 해석 프로그램의 개발 (Development of Simulation Program of Automotive Engine Cooling System)

  • 배석정;이정희;최영기
    • 설비공학논문집
    • /
    • 제15권11호
    • /
    • pp.943-956
    • /
    • 2003
  • A numerical program has been developed for the simulation of automotive engine cooling system. The program determines the mass flow rate of engine coolant circulating the engine cooling system and radiator cooling air when the engine speed is adopted by appropriate empirical correlation. The program used the method of thermal balance at individual element through the model for radiator component in radiator analysis. This study has developed the program that predicts the coolant mass flow rate, inlet and outlet temperatures of each component in the engine cooling system (engine, transmission, radiator and oil cooler) in its state of thermal equilibrium. This study also combined the individual programs and united into the total performance analysis program of the engine cooling system operating at a constant vehicle speed. An air conditioner system is also included in this engine cooling system so that the condenser of the air conditioner faces the radiator. The effect of air conditioner to the cooling performance, e.g., radiator inlet temperature, of the radiator and engine system was examined. This study could make standards of design of radiator capacity using heat rejection with respect to the mass flow rate of cooling air. This study is intended to predict the performance of each component at design step or to simulate the system when specification of the component is modified, and to analyze the performance of the total vehicle engine cooling system.

Effect of Stevia rebaudiana on the Bioactive Compounds from Agarwood Leaf (Aquilaria spp.) by Lactic Fermentation and Spray Drying

  • Dong, Lieu My;Nam, Doan Trung;Phuong, Tran Thi;Thuy, Dang Kim
    • 한국미생물·생명공학회지
    • /
    • 제49권2호
    • /
    • pp.201-209
    • /
    • 2021
  • Agarwood (Aquilaria spp) has high economic value. However, essential oil production from agarwood is a time-consuming process. Additionally, agarwood leaves have not been utilized even though they contain various bioactive ingredients. In this study, agarwood leaves were fermented using Lactobacillus plantarum ATCC 8014 with or without Stevia (4, 8, and 12%; v/v). The fermented fluid was mixed with maltodextrin (15%; w/v) and subjected to spray drying (inlet temperature, 120℃; outlet temperature, 65-70℃). The contents of polyphenols, polysaccharides, saponins, and flavonoids and the viability of L. plantarum were determined. Fermentation enhanced the levels of bioactive compounds. The contents of polyphenol (69.19 ± 4.05 mg GAE/g of sample), polysaccharide (20.75 ± 0.98 mg GE/g of sample), saponin (305.23 ± 4.21 mg OAE/g of sample), and flavonoid (7.86 ± 0.72 mg QE/g of sample), and the viability of L. plantarum (8.72 ± 0.17 log CFU/ml) were markedly upregulated in the samples containing Stevia (12%; v/v). This indicated that the supplementation of Stevia during fermentation decreases the fermentation time (9 h), upregulates bioactive compound production in agarwood leaves, enhances microencapsulation during spray drying, and increases the viability of L. plantarum under simulated gastric digestion conditions.

해양 구조물용 공조덕트 열유동에 관한 수치해석 (Numerical Analysis on the Thermal and Fluid in Air Conditioning Duct for Marine Offshore)

  • 이중섭;이병호;진도훈
    • 한국기계가공학회지
    • /
    • 제17권5호
    • /
    • pp.23-29
    • /
    • 2018
  • This study is about the distribution of heat transfer in air conditioning ducts used for marine vessels and oil drilling platforms. As the convective heat transfer coefficient increased, heat transfer was conducted dynamically to inside as it exited to the outlet of duct. The experiment was to determine if the amount of heat transfer generated at the duct exit increased as the convective heat transfer coefficient increased. When the convective heat transfer coefficient was low, the temperature of the duct showed a relatively high temperature difference between the outside and inside of the duct due to the temperature influence of the internal fluid. In case of temperature distribution generated the volume of the duct along the change of the convective heat transfer coefficient, the temperature descended as heat transfer was promoted and the convective heat transfer coefficient increased.

해양 구조물용 공조덕트 열유동에 관한 수치해석 (Numerical Analysis on the Thermal and Fluid in Air Conditioning Duct for Marine Offshore)

  • 이중섭;이병호;진도훈
    • 한국기계가공학회지
    • /
    • 제18권2호
    • /
    • pp.7-13
    • /
    • 2019
  • This study is about distributions of heat transfer in air conditioning duct used for marine and oil drilling ship. As the convective heat transfer coefficient increased, heat transfer was conducted dynamically to inside as it exited to the outlet of duct. So, it was checked that the amount of heat transfer generated at duct increased as the convective heat transfer coefficient increased. In case the convective heat transfer coefficient was low, the temperature of duct showed the relatively high temperature distribution due to the temperature influence of internal fluid as the heat transfer between the outside and inside of the duct. In case of temperature distribution generated the volume of the duct along the change of the convective heat transfer coefficient, it was found out that the temperature descended as heat transfer was promoted and the convective heat transfer coefficient increased.

벤츄리 노즐 출구 형상과 작동 조건에 따른 캐비테이션 기포 발생 특성 연구 (Generation of emulsions due to the impact of surfactant-laden droplet on a viscous oil layer on water)

  • 오창훈;김준현;성재용
    • 한국가시화정보학회지
    • /
    • 제21권1호
    • /
    • pp.94-102
    • /
    • 2023
  • Three design parameters were considered in this study: outlet nozzle angle (30°, 60°, 80°), neck length (1 mm, 3 mm), and flow rate (0.5, 0.6, 0.7, 0.8 lpm). A neck diameter of 0.5 mm induced cavitation flow at a venture nozzle. A secondary transparent chamber was connected after ejection to increase bubble duration and shape visibility. The bubble size was estimated using a Gaussian kernel function to identify bubbles in the acquired images. Data on bubble size were used to obtain Sauter's mean diameter and probability density function to obtain specific bubble state conditions. The degree of bubble generation according to the bubble size was compared for each design variable. The bubble diameter increased as the flow rate increased. The frequency of bubble generation was highest around 20 ㎛. With the same neck length, the smaller the CV number, the larger the average bubble diameter. It is possible to increase the generation frequency of smaller bubbles by the cavitation method by changing the magnification angle and length of the neck. However, if the flow rate is too large, the average bubble diameter tends to increase, so an appropriate flow rate should be selected.

압전유압펌프 성능실험에 대한 연구 (On the Performance Test of the Piezoelectric-Hydraulic Pump)

  • 주용휘;황재혁;양지연;배재성;이종훈;권준용
    • 한국항공우주학회지
    • /
    • 제43권9호
    • /
    • pp.822-829
    • /
    • 2015
  • 본 논문에서는 압전재료를 이용하여 중소형 무인기 브레이크 시스템에 적용 가능한 압전유압펌프를 설계 및 제작하고, 제작된 압전유압펌프의 성능검증 실험을 수행하였다. 중소형 무인기급 목표 항공기를 선정하여 브레이크 시스템의 요구조건을 분석하였으며, 이를 바탕으로 압전유압펌프의 성능 요구조건을 선정하였다. 요구조건을 만족하는 압전유압펌프의 형상설계를 수행하였으며, 고속 동작 조건에서도 유체의 역류를 효과적으로 차단시킬 수 있는 체크밸브를 비롯한 모든 구성품을 제작하였다. 제작된 압전유압펌프의 성능검증을 위해 실험장치를 구성하여 무부하 토출특성, 부하 시 압력형성 특성실험을 수행하였다. 실험결과, 무부하 최대 토출유량은 80 Hz에서 120.04 cc/min이고, 부하 시 최대 토출압력은 140 Hz에서 783.17 psi이고, 압력형성 반응속도는 약 30 ms 이내임을 확인하였다. 이는 설계 제작된 압전유압펌프가 펌프성능 요구조건을 충족하고 있다고 판단된다.

유입·유출구가 일직선상인 C형 스트레이너 개발을 위한 유동특성 비교 (Comparison of Flow Characteristics for the Development of a C-Type Strainer with Its Inlet and Outlet on a Straight Line)

  • 신병균;권창희
    • 디지털융복합연구
    • /
    • 제14권11호
    • /
    • pp.257-265
    • /
    • 2016
  • 본 연구의 목적은 산업설비나 건축설비의 배관에서 불순물 유입을 막아 유동 시스템을 보호할 수 있는 스트레이너를 개발하기 위함에 있다. 스트레이너는 청수 또는 기름, 가스가 유입되는 배관라인의 밸브, 기기, 펌프 전단에 설치되는 장치로 형태에 따라 Y형, U형, T형이 있다. 본 연구에서는 Y형 스트레이너의 문제점을 파악하고 그 보다 개선된 새로운 모델 "유입․유출구가 일직선상에 있는 C형 스트레이너"를 개발하여 실물 시험을 통해 그 성능을 비교하였다. 시험은 기존 Y형과 C형 스트레이너 50A 실물을 한국표준과학연구원(KRISS) 유동실험실에서 4가지 상황별 실물시험으로 유동특성을 고찰하였다. 실험결과 C형 스트레이너가 Y형 보다 여과망이 없을 때는 74.9%, 여과망에 불순물이 없을 때는 54.5%, 불순물이 15% 쌓였을 때는 54.2%, 불순물이 30% 쌓였을 때는 52.4%가 용량계수(Kv)값이 높았다. 실물제작의 한계로 50A 한 종류만 시험했지만 결과로 볼 때 Y형보다 C형 스트레이너가 유동특성이 우수한 것으로 입증되어 향후 건축, 산업현장에서 유용하게 사용될 것으로 판단되었다.

습식전기집진기를 활용한 입자상 물질 및 황산화물 저감 성능에 관한 실험적 연구 (Experimental Study on Reduction of Particulate Matter and Sulfur Dioxide Using Wet Electrostatic Precipitator)

  • 김종립;오원철;이원주;최재혁
    • 해양환경안전학회지
    • /
    • 제27권6호
    • /
    • pp.898-904
    • /
    • 2021
  • 본 연구에서는 강화되는 황산화물 및 입자상물질의 배출규제를 만족시키기 위한 후처리장치로 습식전기집진기에 대한 실험적 연구를 수행하였다. 실험을 위해 선박용 중유(HFO, 황함유량 약 2.1%)를 연료로 사용하는 선박용 4행정 디젤엔진(STX-MAN B&W)을 활용하였으며, 연돌에 설치된 습식전기집진기 입/출구에서 측정을 실시하였다. 미세먼지 측정을 위해서는 광학식 계측기(OPA-102) 및 중량농도측정방식(Method 5 Isokinetic Train)을 이용하였으며, 황산화물 계측을 위해서는 FT-IR(DX-4000)을 사용하였다. 엔진부하는 50%, 75%, 100%로 변화시키면서 실험을 실시하였다. 실험 결과로, 엔진부하가 50%에서 100%로 변화함에 따라 미세먼지 저감 효율은 모든 부하 조건에서 94~98% 정도의 높은 저감 효율을 나타내었다. 추가적으로 습식전기집진기 퀜칭존에서 배기가스의 온도를 낮추는 과정 중 세정액에 의한 이산화황(SO2) 저감을 확인할 수 있었으며, 저감율은 엔진부하에 따라 55%~81%로 확인되었다.