• 제목/요약/키워드: off-load

검색결과 909건 처리시간 0.033초

공기윤활 다엽포일 저널 베어링의 회전축 부상 특성에 관한 연구 (A Study on the Lift-off Characteristics of an Air-lubricated Multi-leaf Foil Journal Bearing)

  • 이용복;김태호;김창호;이남수;장건희
    • Tribology and Lubricants
    • /
    • 제17권4호
    • /
    • pp.290-296
    • /
    • 2001
  • Lift-off means that the rotating journal surface separates from the leaf surface in an air-lubricated multi-leaf foil journal bearing. Lift-off builds up minimum film thickness which will provide load capacity between leaves and journal. In this paper an analysis of air-lubricated multi-leaf foil journal bearing was performed with effects of multi-leaf foil deflection and compressible lubrication equation simultaneously. Minimum film thickness built up versus journal speed predicts the lift off characteristics and these results will be useful in designing and selecting the proper speed of the air-lubricated multi-leaf foil journal bearing.

Energy-Saving Oriented On/Off Strategies in Heterogeneous Networks : an Asynchronous Approach with Dynamic Traffic Variations

  • Tang, Lun;Wang, Weili;Chen, Qianbin
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제12권11호
    • /
    • pp.5449-5464
    • /
    • 2018
  • Recent works have validated the possibility of reducing the energy consumption in wireless heterogeneous networks, achieved by switching on/off some base stations (BSs) dynamically. In this paper, to realize energy conservation, the discrete time Markov Decision Process (DTMDP) is developed to match up the BS switching operations with the traffic load variations. Then, an asynchronous decision-making algorithm, which is based on the Bellman equation and the on/off priorities of the BSs, is firstly put forward and proved to be optimal in this paper. Through reducing the state and action space during one decision, the proposed asynchronous algorithm can avoid the "curse of dimensionality" occurred in DTMDP frequently. Finally, numerical simulations are conducted to validate the effectiveness and advantages of the proposed asynchronous on/off strategies.

차량 하중 변동에 따른 전조등 컷오프라인 자동 보상에 대한 연구 (A Study on Automatic Compensation for Head Lamps Cut-off Line Under Load Variation)

  • 김기현;김준현;변동규;이동익
    • 한국자동차공학회논문집
    • /
    • 제19권2호
    • /
    • pp.92-97
    • /
    • 2011
  • Vehicle lightings are very important for safe driving during night time. Since the eye recovery time after an exposure to oncoming headlights would take after several seconds, the aiming point of vehicle head lamps have to pass safety requirements. Despite the fact that vehicle inclination is variable with vehicle load conditions, the head lamps aiming point is usually fixed at a constant position which is set by car manufacturer. Consequently, vehicle head lamps under varying load conditions often make people in the opposing vehicle uncomfortable, and even worse, can cause an accident. This paper presents an active vehicle lighting mechanism to automatically adjust its aiming point, or cut-off line, in order to compensate the change in vehicle inclination resulting from load variations. The effectiveness of the proposed method is demonstrated through a set of simulations and experiments with a real vehicle.

유압유의 동점도와 부하변화에 따른 압력의 영향 (The Effects of Dynamic Viscosity and Load od Hydraulic Oil on Pressures)

  • 박주석;김일수;손준식;안영호
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1995년도 추계학술대회 논문집
    • /
    • pp.573-576
    • /
    • 1995
  • The realization by many industrial countries that manufacturing is a critical ingredient for attaining economic strength and stability has led to the development of automated systems which were proviously considered as gimmicks. The adaptive skill of the human operator is now being simulated and reproduced by computer that have become more powerful and less expensive. The work presented in this paper forms an investigation of the effects of dynamic viscosity and load of hydraulic oil an pressures with three different circuit(meter-in, meter-out and bleed off). The experimental results showed that pressures increase with an increase in dynamic viscosity and load in bleed off circuit, but there is no variation of pressure in meter-In meter-out circuit.

  • PDF

이중구조 오리피스 팽창장치의 유동특성에 관한 실험적 연구 (An Experimental Study on Flow Characteristics for Dual-Structured Orifice)

  • 곽경민;김하덕;이중형;배철호;김종엽
    • 설비공학논문집
    • /
    • 제14권12호
    • /
    • pp.1039-1046
    • /
    • 2002
  • To investigate the characteristics of orifice as an expansion devices, the experimental apparatus was made and experiments are being peformed using R22 and R290. The main idea of this control method of refrigerant flow rate with coupled orifices is to control the ON/OFF state of T and Ball type orifice corresponding to the subdivided region of thermal load. When system requires minimum thermal load, both T and Ball type orifices are closed, but refrigerant can flow through small hole of T type orifice. In regular thermal load, when ball type orifice is closed, T type orifice is opened and mass flow rate increase more than OFF state of T type orifice, due to large diameter. In maximum thermal load, both T and Ball type orifices are open and the much refrigerant can flow. The flow characteristics on T type orifice and parallel-combined orifice are obtained in the subdivided region of thermal load.

무정전 전원장치 효율 향상에 대한 연구 (Efficiency Improvement of Uninterruptible Power Supply Systems)

  • 오홍일;권종원;박용만;오드게럴;김희식
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 심포지엄 논문집 정보 및 제어부문
    • /
    • pp.288-290
    • /
    • 2006
  • An efficiency improving method for Uninterruptible Power Supply System(UPS) was developed by using OP-AMP based application circuits such as voltage detection device, current detection device and static switch control device. The efficiency improving algorithm was made by mixing the operating concepts of On-Line type UPS with the operating concepts of Off-Line type UPS. The UPS' inverter does not work if the UPS' output load current is not higher than the low load operating current which is about 0-30(%) of the UPS' output load capacity. The low load operating current is adjustable within the half of the UPS' output load capacity. If the UPS' output load current is rising over than the low load operating current, the UPS' inverter starts working and the inverter output power feeds to the loads of UPS. If UPS' input power breaks out while UPS' inverter does not operate because the load current is low, the inverter starts working within 4(ms) with excessive output voltage which is ${\pm}$8(%) of normal UPS' output voltage. Like these. UPS can continuously feeds power to it's load device and reduce power consumptions.

  • PDF

Exergy Analysis of On/Off Controlled Heat Pump

  • Jang, Ki-Tae;Nam, Kwan-Woo;Jeong, Sang-Kwon
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제7권
    • /
    • pp.22-32
    • /
    • 1999
  • A multi-type heat pump controls the mass flow rate of the working fluid to cope with variable heat loads when it is under dynamic load condition. This paper describes the exergy analysis associated with the unsteady response of a heat pump. First, a basic heat pump cycle is examined at a steady state to show the general trends of exergy variations in each process of the cycle. Entropy generation issue for the heat exchangers is discussed to optimize the heat pump cycle. Secondly, the performance of the inverter-driven heat pump is compared to that of the conventional one when the heat load is variable. Thirdly, the exergy destruction rate of the heat pump with On/Off operation is calculated by simulating the thermodynamic states of the working fluid in the condenser and the evaporator. The inefficiency of On/Off operation during the transient period is quantitatively described by the exergy analysis.

  • PDF

3상 오프라인 무정전 전원 시스템의 돌입전류 제거 (Inrush Current Elimination for a Three-Phase Off-Line UPS System)

  • ;권병일
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2015년도 제46회 하계학술대회
    • /
    • pp.944-945
    • /
    • 2015
  • Many sensitive loads always rely on UPS systems to maintain continuous power during abnormal utility power conditions. As any disturbance occurs at the utility side, an off-line UPS system takes over the load within a quarter cycle to avoid a blackout. However, the starting of the inverter can root the momentous inrush current for the transformer installed before the load, due to its magnetic saturation. The consequences of this current can be a reduction of line voltage and tripping of protective devices of the UPS system. Furthermore, it can also damage the transformer and decrease its lifetime by increasing the mechanical stresses on its windings. To prevent the inrush current, and to avoid its disruptive effects, this paper proposes an off-line UPS system that eliminates the inrush current phenomenon while powering the transformer coupled loads, using a current regulated voltage source inverter (CRVSI) instead of a typical voltage source inverter (VSI). Simulations have been performed to validate the operation of proposed off-line UPS system.

  • PDF

부분축열식 빙축열시스템의 냉방에너지소비 절약을 위한 냉동기 On-Off 제어기법의 평가 (Evaluation of Chiller On-Off Control of Partial Ice Storage System for Energy Saving in Cooling Operation)

  • 이경호;최병윤;이상렬;한승호
    • 한국에너지공학회:학술대회논문집
    • /
    • 한국에너지공학회 2000년도 춘계 학술발표회 논문집
    • /
    • pp.69-74
    • /
    • 2000
  • This paper describes an operation strategy of ice storage systems for energy saving during building cooling. In this study, chiller is assumed not having function of part load control. Thus, it is needed to adopt on-off control with the objective function of summed energy consumption for minimum energy consumption. A conventional control strategy compared with the chiller-on-off control is chiller-priority control. in this control chiller operates as its full capacity and ice storage meets the rest of the cooling load.

  • PDF

On/Off 밸브를 이용한 공압 매니퓰레이터의 고정도 위치제어 (Accurrate Position Control of Pneumatic Manipulator Using On/Off Valves)

  • 표성만;안경관
    • 제어로봇시스템학회논문지
    • /
    • 제11권2호
    • /
    • pp.103-108
    • /
    • 2005
  • Loading/Unloading task in the real industry is performed by crane, but most of the loading/unloading task with the weight of 5kg∼30kg is done by human workers and this kind of work causes industrial disaster of workers. Therefore it is necessary to develop low cost loading/unloading manipulator system to prevent this kind of industrial accidents. This paper is concerned with the design and fabrication of 2 axis pneumatic manipulators using on/off solenoid valves and accurate position control without respect to the external load and low damping in the pneumatic rotary actuator. To overcome the change of external load, switching of control parameter using LVQNN (Learning Vector Quantization Neural Network) is newly applied, which estimates the external loads in the pneumatic cylinder. As an underlying controller, a state feedback controller using position, velocity and acceleration is applied to the switching control system. The effectiveness of the proposed control algorithms are demonstrated through experiments of pneumatic cylinder with various loads.