압력손실을 고려한 양돈시설의 반폐회로 환기시스템의 환기량 및 혼합비율 평가 (Evaluation of Ventilation Rate and External Air Mixing Ratio in Semi-closed Loop Ventilation System of Pig House Considering Pressure Loss)

  • 박유미;김락우;김준규
    • 한국농공학회논문집
    • /
    • 제65권1호
    • /
    • pp.61-72
    • /
    • 2023
  • The increase in the rearing intensity of pigs has caused deterioration in the pig house's internal environment such as temperature, humidity, ammonia gas, and so on. Traditionally, the widely used method to control the internal environment was through the manipulation of the ventilation system. However, the conventional ventilation system had a limitation to control the internal environment, prevent livestock disease, save energy, and reduce odor emission. To overcome this problem, the air-recirculated ventilation system was suggested. This system has a semi-closed loop ventilation type. For designing this system, it was essential to evaluate the ventilation rates considering the pressure loss of ducts. Therefore, in this study, pressure loss calculation and experiment were conducted for the quantitative ventilation design of a semi-closed loop system. The results of the experiment showed that the inlet through which external air flows should always be opened. In addition, it was also found that for the optimum design of the semi-closed loop ventilation system, it was appropriate to install a damper or a backflow prevention device rather than a ventilation fan.

광양지역의 PM10, O3농도와 거주자의 알레르기 증상과의 연관성 (Relationship between PM10 and O3 concentration and allergy symptoms among residents in the Gwangyang area)

  • 오유진;최지희;박희진;김태종;김근배;손부순
    • 실내환경 및 냄새 학회지
    • /
    • 제16권3호
    • /
    • pp.277-286
    • /
    • 2017
  • The objectives of this study were to investigate the effects of $PM_{10}$ and $O_3$ concentration on the symptoms of allergic diseases. The questionnaire was used to determine whether or not symptoms of allergic diseases were present from September to October 2012. The air pollution concentration data used was the corresponding point CEM (continuous emission monitoring) data. The average concentration of $PM_{10}$ was $56.09{\mu}g/m^3$ in the control area, and the concentration in the exposed area was $40.44{\mu}g/m^3$. In the two areas, concentration of $O_3$ was 28.73 ppb and 28.74 ppb, respectively. The total average concentrations of $PM_{10}$ and $O_3$ were $45.66{\mu}g/m^3$ and 28.73 ppb in the Gwangyang area. The rate of asthma diagnosis was higher in the control area (9.6%) than in the exposed area (4.1%), but the rate of allergy eye disease was higher in the exposed area (23.9%) than in the control area (16.5%). There was a significant difference in the symptoms of some allergic diseases when the relative concentration of $PM_{10}$ and $O_3$ were high and low.