Kim, Jong-Cheol;Kim, Yoon-Shin;Roh, Young-Man;Hong, Seung-Cheol;Lee, Cheol-Min;Jun, Hyung-Jin
Journal of Environmental Health Sciences
/
v.33
no.1
s.94
/
pp.1-10
/
2007
This study accomplished to grasp the present condition of HAPs and to examine efficiently carcinogenic and non-carcinogenic health effects through health risk assessment in new apartments from June, 2004 to May,2005. Moreover, we performed uncertainty analysis by Monte-Carlo analysis to control uncertainty of exposure factors. The major results obtained from this study were as follows. Firstly, cancer risk of formaldehyde for male was $1.67{\times}10^{-5}$ in CTE in point estimation. Cancer risk of formaldehyde was showed $2.94{\times}10^{-3}$ in RME that applied worst case used results of 95 percentile in point estimation. It exceeds $10^{-6}$ of guide line in US EPA. Moreover, cancer risks of formaldehyde for female were $3.98{\times}10^{-5}$ in CTE and $3.93{\times}10^{-3}$ RME. Secondly, every hazard index for non-carcinogenic pollutants was less than 1 of permitted standards in CTE. However, in RME of male, hazard indexes of 1,2-Dichloropropane and Toluene were 1.3 and 2.0, respectively. Hazard indexes of 1,2-Dichloropropane and Totuene for female in RME were 1.7 and 2.6, respectively.
Min-Seop SIM;Jeong-Min Lee;Do-Yean KIM;Yul-Seong Kim
Journal of Navigation and Port Research
/
v.47
no.1
/
pp.37-48
/
2023
Recently, the increase of international trade volume is leading to risk exposure and safety accidents in the port terminal industry. In addition, as Serious Disaster Punishment Act came into effect on January, 2021, various guidelines and laws to protect safety and life in port terminals are being enacted. However, despite these efforts, medium-to-large safety accidents in the port terminal industry have occurred. According to the Korea Occupational Safety and Health Agency, from 2016 to 2019, the number of casualties in the port handling industry increased by 4.2%. To build some effective follow-up management of port accidents and preparation of related safety laws/systems, a risk analysis in consideration of causes and damage of accidents should be conducted. Therefore, in this study, major risk factors and preventive measures were derived by conducting risk assessment based on 1,039 cases of port terminal accidents collected by the Korea Occupational Safety and Health Agency for five years. Priorities for preventive measures were then determined through IPA analysis, Borich needs analysis, and The Locus For Focus analysis.
Journal of Korean Society of Occupational and Environmental Hygiene
/
v.6
no.1
/
pp.1-16
/
1996
This study was conducted at an automobile assembly line located in Kyonggi-do, Korea from January 16 to February 28, 1995. The purposes of this study were to assess worker exposures to hand-arm vibration and the performance of gloves for reduction of vibration. The exposure to vibration was measured using to the ISO 5349(1986) method. Vibration acceleration and frequency spectra for each tool were determined on-line replicating actual working conditions and analyzed together with exposure time for evaluating individual worker exposure. Eight pneumatic hand tools, 60 workers exposured to hand-arm vibration, and three pairs of gloves were involved in this study. Results are summarized as follows. 1. Dominant frequencies of vibration for all tools(n=8) measured in this study ranged from 250 Hz to 800 Hz. 2. There was no significant correleration between dominant frequencies and free running speed (p>0.05). 3. Total predicted exposure times of using impact, hammer type did not exceed 40 minutes, but metal finish task, using grinder and sander exceeded 40 minutes. Total exposure time affected significantly the frequency-weighted, 4 hr equivalent acceleration. 4. Predicted prevalence and observed exposure period data were compared in workers(n=60), according to ISO 5349. In this results, 23(50.0 %) and 24(48.07 %) persons exceeded the mean latency periods for vibration-induced white finger(VWF) at 10 % (n=46) and 50 % (n=52) standards, respectively. On the basis of ISO equation, mean latent periods for VWF were 3.23, 4.72 years at 10 %, 50 % standards, respectively. 5. Reduction of vibration by gloves was evaluated. Since impact pneumatic tools produced low frequency vibrations, conventional gloves did not provide any protection. Gloves A and C amplify somewhat the signal at frequency below 400 Hz; the attenuation increases progressively by frequency to reach 18 dB ($7.94{\times}10^{-6}m/s^2$) at 1,000 Hz, slightly worsening Glove B did not provide any protection and made the situation slightly worse. However, since they make the hands warm, the occurrence of vibration-induced white fingers may be reduced.
Objectives: This study was conducted to suggest the necessity of education about toothpaste usage to infants, preschoolers, and their parents. Also, another purpose is to provide basic data that is necessary for oral health education about accurate cognition and usage of toothpaste. Methods: From October to December 2015, we conducted a survey on parents of 0~4 years old infants and preschoolers about toothpaste usage based on the data of a questionnaire with a total of 505 subjects. The survey questions were composed of general characteristics of infants, preschoolers and their parents, and toothpaste usage. Results: Usage frequency of toothpaste for infants and preschoolers increased with age (p<0.001), and infants and preschoolers in homes with monthly income under 4 million won showed high frequency of toothpaste usage (p<0.001). Toothpaste mouth rinsing of infants and preschoolers increased with age (p<0.001), while on the other hand, toothpaste swallowing decreased (p<0.001). Conclusions: In this study, it was shown that the factors that effect toothpaste usage in infants and preschoolers were age and average monthly income of the family. This suggests the necessity of oral health education to parents about usage of toothpaste in infants and preschoolers.
Park, Jinhyeon;Ryu, Hyeonsu;Heo, Jung;Cho, Mansu;Yang, Wonho
Journal of Environmental Health Sciences
/
v.45
no.1
/
pp.1-8
/
2019
Objectives: The purpose of this study was to estimate the ventilation rate of residential homes in Korea through tracer gas methods using indoor and outdoor concentrations of carbon dioxide ($CO_2$) and $CO_2$ generation rates from breathing. Methods: In this study, we calculated the number of occupants in a home by time through data on the average number of people per household from the Korean National Statistical Office and also measured the amount of $CO_2$ generation by breathing to estimate the indoor $CO_2$ generation rate. To estimate the ventilation rate, several factors such as the $CO_2$ generation rate and average volume of residential house provided by the Korean National Statistical Office, indoor $CO_2$ concentrations measured by sensors, and outdoor $CO_2$ concentrations provided by the Korea Meteorological Administration, were applied to a mass balance model for residential indoor environments. Results: The average number of people were 2.53 per household and Koreans spend 61.0% of their day at home. The $CO_2$ generation rate from breathing was $13.9{\pm}5.3L/h$ during sleep and $15.1{\pm}5.7L/h$ in a sedentary state. Indoor and outdoor $CO_2$ concentrations were 849 ppm and 407 ppm, respectively. The ventilation rate in Korean residential houses calculated by the mass balance model were $42.1m^3/h$ and 0.71 air change per hour. Conclusions: The estimated ventilation rate tended to increase with an increase in the number of occupants. Since sensor devices were used to collect data, sustainable data could be collected to estimate the ventilation rate of Korean residential homes, which enables further studies such as on changes in the ventilation rate by season resulting from the activities of occupants. The results of this study could be used as a basis for exposure and risk assessment modeling.
Acetanilide may be released into the environment through air and wastewater from its production and use sites and exposed to human. Acetanilide is known to produce an analgesic effect and may pose adverse effects on human health by overly exposure. According to the EUSES system, acetanilide showed a high MOS (Margin of safety) value exceeding 6$\times$10$^4$ on a regional exposure, which is safe enough for public health. Whereas the lowest MOS value in dermal exposure was estimated as 3$\times$10$^{-4}$ on a local basis (workplace), the risk could be partly counteracted by taking preventive measures such as using mask and globes and good ventilation in the work places. Acetanilide may pose a potential risk for workers by dust inhalation. For the sake of health protection in the work places, additional data should be accumulated with respect to repeated dose toxicity, reproduction toxicity and developmental toxicity, etc. It is, therefore, recommended that acetanilide should be a candidate for further work to supplement the lacking data until it is proved to be safe in the occupational health aspects.
International Commission on Radiological Protection (ICRP) has revised its recommendations concerning the tissue reaction to ionizing radiation in accordance with consideration of the detriment arising from non-cancer effects of radiation on health based on recent epidemiological basis. Particularly, for the lens of the eye, the threshold in absorbed dose revised to be 0.5 Gy, for occupational exposure in planned exposure situation the commission recommended "An equivalent dose limit for the lens of the eye of 20 mSv in a year, averaged over defined periods of 5 years, with no single year exceeding 50 mSv." To monitor the radiation exposure of radiation worker, TLD is typically provided and the lens of eye dose can be assessed by run of dose calculation algorithm with TL element response data. This study is to assess equivalent dose of the lens of eye using the Harshaw TLD system and its two different dose calculation algorithms. The result provides the Harshaw TLD system showed the assessment of the lens of eye dose with 48.84% error range.
Chung, Jaeyeon;Yoon, Hae-Seong;Ryu, Hee-Young;Won, Jong Uk;Paeng, Ki-Jung;Kim, Yunje
Analytical Science and Technology
/
v.21
no.3
/
pp.183-190
/
2008
PFOS (Perfluorooctane sulfonate) and PFOA (Perfluorooctanoic acid) are environmental hormones which belong to potential future persistent organic pollutants (POPs), and it is easy to exposure to human because they are used in a wide variety of consumer products. We studied exposure route and the relativity through determining and monitoring of PFOS and PFOA in Korean plasma of metropolis, small town, rural area and industrial area. And we monitored the concentration of PFOS and PFOA regarding the gender and age. The older age is, the higher concentration of PFOS is. The mean concentration of PFOS and PFOA in men (4.74 ng/mL, 2.20 ng/mL) was higher than that in women (3.53 ng/mL, 1.17 ng/mL). In the comparison of residential areas, the mean concentration of PFOS and PFOA was the lowest in metropolitan plasma (2.47 ng/mL, 0.79 ng/mL) whereas it was the highest in the industrial area (6.57 ng/mL, 2.19 ng/mL).
Background: Street vendors spend relatively more time near roadways and are vulnerable to air pollution related health disorders. However, there is limited information on the quality of the air they breathe. The objectives of this present study were to calculate the mass concentration of atmospheric particulate matter (PM) in eight size fractions ($PM_{0.4-0.7}$, $PM_{0.7-1.1}$, $PM_{1.1-2.1}$, $PM_{2.1-3.3}$, $PM_{3.3-4.7}$, $PM_{4.7-5.8}$, $PM_{5.8-9.0}$, and $PM_{9.0--0{\mu}m}$) at commercial (CML) and residential site (RSL) in Dehradun city from November 2015 to May 2016. To estimate the corresponding respiratory deposition dose (RDDs) in alveolar (AL), tracheobronchial (TB), and head airway (HD) region on street vendors working at CML and RSL. To find the association of atmospheric PM with RDDs and the incidence of respiratory related disorders among street vendors. Methods: Andersen cascade impactor was employed for calculating the PM mass concentration. Questionnaire based health survey among street vendors were carried out through personal interview. Results: A significant difference (p < 0.05; t-test) between the mean $PM_{0.4-10{\mu}m}$ mass concentration at CML and RSL was observed with ($mean{\pm}SD$) $84.05{\pm}14.5$ and $77.23{\pm}11.7{\mu}g\;m^{-3}$, respectively. RDDs in AL, TB and HD region at CML was observed to be 9.9, 7.8, and 7.3% higher than at RSL, respectively. Health survey revealed 1.62, 0.96, 0.04, and 0.57 times higher incidence of cold, cough, breathlessness, and chest pain, respectively with street vendors at CML compared to RSL. Conclusion: The site characteristics plays a major role in the respiratory health status of street vendors at Dehradun.
KIM, Do-Yean;SIM, Min-Seop;Lee, Jeong-Min;SHIN, Yong-Ran
Journal of Navigation and Port Research
/
v.46
no.1
/
pp.57-72
/
2022
The recent increase in international trade volume and explosive increase in cargo volume due to the non-face-to-face society are leading to an increase in risk exposure and safety accidents in the port logistics industry. Consequently, as the atmosphere and consensus on safety are spreading throughout the society, various safety laws are being enacted by the industry. Nevertheless, according to the industrial accidents status analysis by the Ministry of Employment and Labor, the average annual number of injured persons increased by 11.1% and the number of deaths by 4.0% from 2015 to 2019. This means that special attention should be paid to possible future risks and preventive measures for major causes of accidents should be established. Therefore, in this study, risk assessment was conducted based on 5,028 accident cases that were reported by the Korea Occupational Safety and Health Agency for 5 years, from 2016 to 2020, and major risk factors for each industry were derived, and then bow-tie analysis was conducted to perform the risk assessment; Further, the study aimed to derive the causes and preventive measures from the risk factors.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.