• Title/Summary/Keyword: occlusal contact

Search Result 190, Processing Time 0.028 seconds

FINITE ELEMENT ANALYSIS OF MANDIBULAR STRESSES AND DENTURE MOVEMENTS INDUCED BY OVERDENTURES (Overdenture 하에서 하악응력 및 의치의 변위에 관한 유한요소법적 분석)

  • Kim, Joung-Hee;Chung, Chae-Heon;Cho, Kyu-Zong
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.28 no.1
    • /
    • pp.63-94
    • /
    • 1990
  • The purpose of this study was to analyze the displacement and the magnitude and the mode of distribution of the stresses in the lower overdenture, the mucous membrane, the abutment tooth and the mandibular supporting bone when various denture base materials, such as acrylic resin and 0.5mm metal base, and various denture base designs were subjected to different loading schemes. For this study, the two-dimensional finite element method was used. Mandibular arch models, with only canine remaining, were fabricated. In the first denture base design, a space, approximately 1mm thick, was prepared between the denture and the dome abutment. In the second denture base design, contact between the denture and the dome abutment was eliminated except the contact of the occlusal third of the abutment. In order to represent the same physiological condition as the fixed areas of the mandible under loading schemes, the eight nodes which lie at the mandibular angle region, the coronoid process and the mandibular condyle were assumed to be fixed. Each model was loaded with a magnitude of 10 kgs on the first molar region(P1) and 7 kgs on the central incisal region (P2) in a vertical direction. Then the force of 10 kgs was applied distributively from the first premolar to the second molar of each model in a vertical direction(P3). The results were as follows. : 1. When the testing vertical loads were given to the selected points of the overdenture, the overdenture showed the rotatory phenomenon, as well as sinking and the displacements of alveolar ridge, abutment and lower border of mandible under the metal base overdenture were less than those under the acrylic resin overdenture. 2. The maximum principal stresses(the maximum tensile stresses) being considered, high tensile stresses occured at the buccal shelf area, the posterior region of the ridge crest and the anterior border region of the mandibular ramus. 3. The minimum principal stresses(the maximum compressive stresses) being considered, high compressive stresses occured at the inferior and posterior border region of the mandible, the mandibular angle and the posterior border region of the mandibular ramus. 4. The vertical load on the central incisal region(P2) produced higher equivalent stress in the mandible than that on any other region(P1, P3) because of the long lever arm distance from the fixed points to the loading point. 5. Higher equivalent stresses were distributed throughout the metal base overdenture than the resin base overdenture under the same loading condition. 6. The case of occlusal third contact of the abutment to the denture produced higher equivalent stresses in the abutment, the mandibular area around the abutment and the overdenture than the case of a 1mm space between the denture and the abutment. 7. Without regard to overdenture base materials and designs, the amounts and distribution patterns of equivalent stresses under the same loading condition were similar in the mucous membrane.

  • PDF

Stress Analysis on the Supporting Bone around the Implant According to the Vertical Bone Level (치조골 높이가 다른 임프란트 주위 지지골 응력분석)

  • Boo, Soo-Boong;Jeung, Jei-Ok;Lee, Seung-Hoon;Kim, Chang-Hyun;Lee, Seung-Ho
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.23 no.1
    • /
    • pp.55-68
    • /
    • 2007
  • The purpose of this study was to analyze the distribution of stress in the surrounding bone around implant placed in the first and second molar region. Two different three-dimensional finite element model were designed according to vertical bone level around fixture ($4.0mm{\times}11.5mm$) on the second molar region. A mandibular segment containing two implant-abutments and a two-unit bridge system was molded as a cancellous core surrounded by a 2mm cortical layer. The mesial and distal section planes of the model were not covered by cortical bone and were constrained in all directions at the nodes. Two vertical loads and oblique loads of 200 N were applied at the center of occlusal surface (load A) or at a position of 2mm apart buccally from the center (load B). Von-Mises stresses were analyzed in the supporting bone. The results were as follows; 1. With the vertical load at the center of occlusal surface, the stress pattern on the cortical and cancellous bones around the implant on model 1 and 2 was changed, while the stress pattern on the cancellous bone with oblique load was not. 2. With the vertical load at the center of occlusal surface, the maximum von-Mises stress appeared in the outer distal side of the cortical bone on Model 1 and 2, while the maximum von-Mises stress appeared in the distal and lingual distal side of the cortical bone with oblique load. 3. With the vertical load at a position of 2 mm apart buccally from the center, there was the distribution of stress on the upper portion of the implant-bone interface and the cortical bone except for the cancellous bone, while there was a distribution of stress on the cancellous bones at the apical and lingual sides around the fixture and on the cortical bone with oblique load. 4. With the changes of the supporting bone on the second molar area, the stress pattern on the upper part of the cortical bone between two implants was changed, while the stress pattern on the cancellous bone was not. The results of this study suggest that establishing the optimum occlusal contact considering the direction and position of the load from the standpoint of stress distribution of surrounding bone will be clinically useful.

A Study on the Eruption Time of Permanent Teeth with the Eruption Phases in Korean-I. - Studies on the eruption phases of permanent first molars - (한국인 영구치의 단계별 붕출시기에 관한 연구-I -제일대구치의 붕출시기에 관하여-)

  • 정성창
    • Journal of Oral Medicine and Pain
    • /
    • v.3 no.1
    • /
    • pp.11-22
    • /
    • 1977
  • In order to evaluate the normal eruption time of the Korean permanennt teeth, the author had examined the eruption phases of permanent first molars in 778 males and 653 female children aged from 5 to 9-year old and analysed. The eruption was divided into 4 phases; the tip of the crown can be seen, the dull occlusal surface of the crown can be easily seen, the crown is not in contact with its antagonist, and the crown is in contact with its antagonist. The obtained results were as follows : 1. It seemed that percentage of the eruptingand erupted permanent first molar in female by age was higher than that of male. 2. In general, percentage of the erupting and erupted permanent first molar by age was higher than that of upper first molar. 3. In the correlation of age with the eruption phase, the regression equation were "y=0.43x+5.61" on male upper first molar, "y=0.41x+5.60" on male lower first molar, "y=0.44x+5.47" on female upper first molar, and "y=0.38x+5.57" on female lower first molar respectively.n female lower first molar respectively.

  • PDF

Splinted and non-splinted implant-supported restorations : prosthetic considerations for restoring multiple adjacent teeth (Splinted or Non-splinted: 다수의 인접한 치아 결손부 수복을 위한 임플란트 보철)

  • Yoon, Hyung-In
    • The Journal of the Korean dental association
    • /
    • v.54 no.3
    • /
    • pp.198-205
    • /
    • 2016
  • The purpose of this paper was to investigate the significance of splinted and non-splinted implant-supported restorations with an internal connection for multiple consecutively missing teeth. Upon examination of the effects of fixture-abutment connection, the distribution of occlusal load was favorable in splinted implant-prosthesis with an external connection, but effect of strain distribution was not significant in splinted implant-prosthesis with an internal connection. In splinted implant-prostheses for short implants, strain distribution was not affected by the method of retention. For cement-retained prostheses, the effect of strain distribution due to splinting was not significant. In clinical studies, non-splinted prostheses with an internal connection for multiple consecutively missing teeth showed high survival rate, mild marginal bone loss, and stable periodontal condition. However, failure to achieve optimal proximal contact between single-unit prostheses may lead to food impaction, and veneer fracture may be inevitable when the framework provides inadequate support in the proximal region. In conclusion, splinted implant-prosthesis is not an indication in all cases, and clinical consideration of its use should be based on the patient's oral condition, such as location and number of implants, formation of proximal contact, canine guidance, existence of parafunctional habit, and oral hygiene, when multiple consecutively missing teeth are replaced by internal connection type implant.

  • PDF

Protrusive maxillomandibular fixation for intracapsular condylar fracture: a report of two cases

  • Jeong, Yeong Kon;Park, Won-Jong;Park, Il Kyung;Kim, Gi Tae;Choi, Eun Joo
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.43 no.5
    • /
    • pp.331-335
    • /
    • 2017
  • Clinical limitations following closed reduction of an intracapsular condylar fracture include a decrease in maximum mouth opening, reduced range of mandibular movements such as protrusion/lateral excursion, and reduced occlusal stability. Anteromedial and inferior displacement of the medial condyle fragment by traction of the lateral pterygoid muscle can induce bone overgrowth due to distraction osteogenesis between the medial and lateral condylar fragments, causing structural changes in the condyle. In addition, when conventional maxillomandibular fixation (MMF) is performed, persistent interdental contact sustains masticatory muscle hyperactivity, leading to a decreased vertical dimension and premature contact of the posterior teeth. To resolve the functional problems of conventional closed reduction, we designed a novel method for closed reduction through protrusive MMF for two weeks. Two patients diagnosed with intracapsular condylar fracture had favorable occlusion after protrusive MMF without premature contact of the posterior teeth. This particular method has two main advantages. First, in the protrusive position, the lateral condylar fragment is moved in the anterior-inferior direction closer to the medial fragment, minimizing bone formation between the two fragments and preventing structural changes. Second, in the protrusive position, posterior disclusion occurs, preventing masticatory muscle hyperactivity and the subsequent gradual decrease in ramus height.

Evaluation of adjacent tooth displacement in the posterior implant restoration with proximal contact loss by superimposition of digital models

  • Jo, Deuk-Won;Kwon, Min-Jung;Kim, Jong-Hee;Kim, Young-Kyun;Yi, Yang-Jin
    • The Journal of Advanced Prosthodontics
    • /
    • v.11 no.2
    • /
    • pp.88-94
    • /
    • 2019
  • PURPOSE. This study was conducted to investigate patterns of adjacent tooth displacement in the posterior implant with interproximal contact loss (ICL) by 3-D digital superimposition method. MATERIALS AND METHODS. Posterior partially edentulous patients, restored with implant fixed partial prostheses before 2011 and suffered from food impaction of ICL between 2009 and 2011, were included. Two dental casts, at the time of delivery and at the time of food impaction in a same patient, was converted into 3-D digital models through scanning and superimposition was performed to assess chronologic changes of the dentition. Directions of tooth displacement were evaluated and the amount of ICL was calculated. Correlations between the amount of ICL and elapsed time, or between the amount of ICL and age after function, were assessed at a significance level of P<.05. RESULTS. A total number of 13 patients (8 males, 5 females) with a mean age of $65.76{\pm}9.94years$ and 17 areas (4 maxillae, 13 mandibles) were included in this retrospective study. Teeth adjacent to the implant restoration showed complex displacements but characteristic tendency according to the location of the arch. The mean amount of ICL was $0.33{\pm}0.14mm$. Elapsed time from function to ICL was $61.47{\pm}31.27months$. There were no significant differences between the amount of ICL and elapsed time, or age (P>.05). CONCLUSION. Natural teeth showed various directional movements to result in occlusal change in the arch. The 3-D superimposition of chronologic digital models was a helpful method to analyze the changes of dentition and individual tooth displacement adjacent to implant restoration.

A STUDY ON THE FACTORS AFFECTING TO TOOTH WEAR (치아교모에 영향을 미치는 요인에 관한 연구)

  • Park, Hyun-Bae;Han, Kyung-Soo;Jin, Tai-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.37 no.3
    • /
    • pp.328-342
    • /
    • 1999
  • This study was performed to investigate the factors related to tooth wear. For this study, 78 patients with temporomandibular disorders and 76 dental students without any signs and symptoms of temporomandibular disorders were selected as the patients group and as the normal group, respectively. Preferred chewing side, Angle's classification, lateral guidance pattern, head and shoulder posture were observed clinically. Electromyographic activity of anterior temporalis and masseter muscle were recorded with $BioEMG^{(R)}$ and occlusal status were recorded with $T-Scan^{(R)}$. Wear facet area of each tooth was measured from working model of upper arch corresponding to the occlusal status from T-Scan. Wear facet area were measured with planimeter in $mm^2$. Total area were divided into incisal, canine, posterior tooth area. Anterior wearfacet area was incisor area plus canine area, and unilateral area was anterior area plus posterior area. The data collected were analyzed by SAS statistical program and the results of this study were as follows: 1. There was no significant difference between the two groups in total werafacet area, and male subjects showed tendency to have larger area in the normal group but female subjects showed tendency vice versa. 2. There was no significant difference related to preferred chewing side and Angle's classification, however some difference was observed by lateral guidance pattern. Anterior wear facet area in subjects of canine guidance was the largest in the three subgroups. 3. Subjects with head tilting to right side had larger posterior and total area, and subjects with higher shoulder in right side had larger canine and anterior area than any other subgrous. 4. Electromyographic activity of masseter muscle was more correlated with wear facet area than anterior temporalis muscle, and tooth contact number and force were significantly correlated with wear facet area, but the most important factor affecting tooth attrition was age.

  • PDF

The 3-Dimensional Finite Element Analysis of Minimum Implant Structure for Edentulous Jaw (무치악에 대한 최소 임플란트의 구조물의 3차원 유한요소 해석)

  • Jang, In-Sik
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.25 no.2
    • /
    • pp.148-155
    • /
    • 2008
  • The aim of the study is to interpret the distribution of occlusal force by 3-dimensional finite element analysis of ISP(Implant Supported Prosthesis) supported by minimum number of implant to restore the edentulous patients. For this study, the Astra Tech implant system is used. Geometric modeling for 6 and 4 fixture ISP group is performed with respect to the bone, implant and one piece superstructure, respectively. Implants are arbitrarily placed according to the anatomical limit of lower jaw and for the favorable distribution of occlusal force, which is applied at the end of cantilever extension of ISP with 30mm. Element type is tetrahedral for finite element model and the typical mechanical properties, Young's modulus and Poisson's ratio of each material, cortical, cancellous bone and implant material are utilized for the finite element analysis. From this study, we can see the distribution of equivalent stress equal to real situation and speculate the difference in the stress distribution in the whole model and at each implant fixture, From the analysis, the area of maximum stress is distributed on distal contact area between bone and fixture in the crestal bone. The maximum stress is 53MPa at the 0.2mm area from the bone-implant interface in the maximum side for 300N load condition for 4 fixture case, which is slightly less than the stress calculated from allowable strain. This stress has not been deduced to directly cause the loss of crestal bone around implant fixture, but the stress can be much reduced as the old peoples may have lower chewing force. Thus, clinical trial may be performed with this treatment protocol to use 4 fixtured ISP for old patients.

Stress distribution in premolars restored with inlays or onlays: 3D finite element analysis

  • Yang, Hongso;Park, Chan;Shin, Jin-Ho;Yun, Kwi-Dug;Lim, Hyun-Pil;Park, Sang-Won;Chung, Hyunju
    • The Journal of Advanced Prosthodontics
    • /
    • v.10 no.3
    • /
    • pp.184-190
    • /
    • 2018
  • PURPOSE. To analyze stress distribution in premolars restored with inlays or onlays using various materials. MATERIALS AND METHODS. Three-dimensional maxillary premolar models of abutments were designed to include the following: 1) inlay with O cavity (O group), 2) inlay with MO cavity (MO group), 3) inlay with MOD cavity (MOD group), and 4) onlay (ONLAY group). A restoration of each inlay or onlay cavity was simulated using gold alloy, e.max ceramic, or composite resin for restoration. To simulate masticatory forces, a total of 140 N static axial force was applied onto the tooth at the occlusal contact areas. A finite element analysis was performed to predict the magnitude and pattern of stresses generated by occlusal loading. RESULTS. Maximum von Mises stress values generated in the abutment teeth of the ONLAY group were ranged from 26.1 to 26.8 MPa, which were significantly lower than those of inlay groups (O group: 260.3-260.7 MPa; MO group: 252.1-262.4 MPa; MOD group: 281.4-298.8 MPa). Maximum von Mises stresses generated with ceramic, gold, and composite restorations were 280.1, 269.9, and 286.6 MPa, respectively, in the MOD group. They were 252.2, 248.0, 255.1 MPa, respectively, in the ONLAY group. CONCLUSION. The onlay design (ONLAY group) protected tooth structures more effectively than inlay designs (O, MO, and MOD groups). However, stress magnitudes in restorations with various dental materials exhibited no significant difference among groups (O, MO, MOD, ONLAY).

The Effect of Occlusal Stabilization Splint Therapy on the Occlusal Contact Stability and Masticatory muscle Activities in the Patients with Temporomandibular Disorders (측두하악장애환자에 있어서 교합안정장치가 교합안정성 및 저작근활성에 미치는 영향)

  • Jye-Jynn Ann;Jae-Kap Choi;Jae-Hyun Sung
    • Journal of Oral Medicine and Pain
    • /
    • v.17 no.1
    • /
    • pp.73-87
    • /
    • 1992
  • 저자는 28명의 측두하악장애 환자와 31명의 정상인을 대상으로 최적기능교합의 개념에 입각하여 교합시의 치아접촉점을 동적이며 정량적인 방법으로 평가하여 교합안정장치의 사용으로 인한 교합안정성의 개선여부를 알아보고자 하였다. 이와 동시에 교근과 전측두근의 활성도를 측정하여 치료의 경과에 따른 근활성의 변화를 알아보기 위해 본 연구를 시행하였다. 측정항목은 개구범위, 두개하악장애지수, 치아접촉점 좌우균형치, 치아접촉점 전후균형치, 치아접촉점 평균시간간격, 치아접촉점의 개수, 접촉시간, 좌우측 교근과 좌우측 전측두근의 근활성, 근활성 비대칭 지수 등이었다. 이의 측정을 위해 T-Scan System, K-6 Diagnostic System 그리고 EM 2등을 사용하였으며 얻어진 자료에 대해 검정한 후 다음과 같은 결론을 얻었다. 1. 교합안정장치를 이용하여 측두하악장애 환자들을 4주간 치료한 결과 전반적인 임상증상이 호전되어 개구범위와 두개하악장애지수에 있어서 뚜렷한 개선이 있었다. 2. 측두하악장애 환자에서 최대 악물기시의 치아접촉점 좌우균형치및 평균시간 간격이 큰 것으로 나타나 치아접촉이 일어나는 순간의 교합안정성이 좋지 않은 것으로 평가되었다. 3. 치료 4주후 교하안정장치를 장착한 상태에서 측정한 치아접촉점 좌우균형치및 치아접촉점 평균시간간격은 치료전에 비해 개선된 것으로 나타났다. 4. 치료 4주후 치아접촉점의 전후방 분포가 구치부위로 이동되는 양상을 보였다. 5. 측두하악장애 환자에서 최대 악물기시의 좌우측 교근 및 전측두슨의 근활성은 정상인에 비해 낮에 나타났으며, 이는 치료기간 동안 감소되는 경향을 나타내었다. 6. 측두하악장애 환자에서 전측두근의 근활성 비대칭지수는 정상인에 비해 상당히 높게 나타났으며 이는 치료기간 동안 감소되는 경향을 나타내었다.

  • PDF