• Title/Summary/Keyword: obstructive sleep apnea

Search Result 322, Processing Time 0.048 seconds

A Case of Partial DiGeorge Syndrome in Prematurity (미숙아에서 발견된 부분형 DiGeorge 증후군 1례)

  • Sung, Tae Jung;Ko, Eun Young;Kim, Dal Hyon;Oh, Ji Eun;Kwon, Young Se;Lim, Dae Hyun;Son, Byong Kwan
    • Clinical and Experimental Pediatrics
    • /
    • v.45 no.3
    • /
    • pp.383-389
    • /
    • 2002
  • We experienced a case of partial DiGeorge syndrome in a $35^{+5}$ week premature female infant presented with micrognathia, fish-shaped mouth, beaked nose, nasal regurgitation, obstructive sleep apnea, velopharyngeal insufficiency and late onset hypocalcemic seizures. The chromosome 22q11 microdeletion was found by the FISH method. The lab findings showed serum calcium level of 4.4 mg/dL, ionized calcium level of 0.49 mg/dL, phosphorous level of 7.5 mg/dL, magnesium level of 1.3 mg/dL and PTH-RIA level of <1 pq/mL. Initial treatment was done with 10% calcium gluconate infusion and magnesium sulfate followed by oral calcium gluconate and low phosphorousformula milk feeding. The serum calcium level was normalized in 6 days. Nasal regurgitation, desaturation with obstructive sleep apnea continued. T-cell functions & numbers(CD 3, CD 4, CD 8)were decreased but Ig G/A/M levels were normal. No visible signs of thymus shadow were seen in either chest X-ray & chest MRI. Electrocardiography and echocardiography showed normal heart. Kidney ultrasonographby showed right side mild hydronephrosis. Neurosonography was normal but EEG showed electrical partial seizure. Hearing assessment by BERA showed mild to moderate hearing impairment. Velopharyngoplasty is scheduled for further treatment. A brief review of literature was made.

The Effect of Continuous Positive Pressure Therapy for Obstructive Sleep Apnea on Quality of Life : A Single-Institution Study (폐쇄성수면무호흡증에 대한 지속적 양압치료가 삶의 질에 미치는 영향 : 단일기관 연구)

  • Shin, Hyun Suk;Choi, Mal Rye;Kim, Shin il;Hong, Se Yeon;Eun, Hun Jeong
    • Sleep Medicine and Psychophysiology
    • /
    • v.27 no.2
    • /
    • pp.56-66
    • /
    • 2020
  • Objectives: In this study, the clinical characteristics of OSA patients and the quality of life before and after CPAP use were compared to determine the degree of improvement in quality of life according to CPAP use. Methods: Age, sex, height, weight, body mass index, Epworth Sleepiness Scale, Modified Mallampatti Score, Montreal Cognitive Assessment-Korean, and Pittsburgh Sleep Quality Index were compared between men and women through medical records. To understand the degree of improvement in quality of life resulting from use of CPAP, a personal telephone call was made to compare the VAS scores for quality of life before and after CPAP use. Results: In height (HT) (Z = -4.525, p < 0.001), weight (BW) (Z = -2.844, p < 0.05), sleep quality (PSQI) (Z = -2.671, p < 0.05), and arousal index (AI) (Z = -2.105, p < 0.05), there was a difference between men and women (p < 0.05). There was no difference in the remaining variables. Cross-analysis (Chi-square test) confirmed a difference between severity and sex of OSA. It has been found that there is no statistically significant order in size according to level-specific severity of OSA for PreCPAP QOL, PostCPAP QOL, CPAPUse Months, and CPAP4Hr/d (%) (p > 0.05). The difference between AHI before and after CPAP was 36.48 ± 21.54 (t = 11.609, p < 0.001) and the difference between QOL before and after CPAP was -25.43 ± 22.06 (t = -7.901, p < 0.001), both of which were significant (p < 0.001). Conclusion: Among OSA patients, there were differences in height (HT), weight (BW), sleep quality (PSQI), arousal index (AI), and severity of OSA between men and women, but the quality of life before and after CPAP was different. However, there was no difference between men and women in quality of life before and after CPAP. In addition, quality of life in OSA patients improved after using CPAP.

Blood Pressure Reactivity during Nasal Continuous Positive Airway Pressure in Obstructive Sleep Apnea Syndrome (폐쇄성(閉鎖性) 수면무호흡증(睡眠無呼吸症)에서 지속적(持續的) 상기도(上氣道) 양압술(陽壓術)이 혈력학적(血力學的) 변화(變化)에 끼치는 영향(影響))

  • Park, Doo-Heum;Jeong, Do-Un
    • Sleep Medicine and Psychophysiology
    • /
    • v.9 no.1
    • /
    • pp.24-33
    • /
    • 2002
  • Objectives: Nasal continuous positive airway pressure (CPAP) corrected elevated blood pressure (BP) in some studies of obstructive sleep apnea syndrome (OSAS) but not in others. Such inconsistent results in previous studies might be due to differences in factors influencing the effects of CPAP on BP. The factors referred to include BP monitoring techniques, the characteristics of subjects, and method of CPAP application. Therefore, we evaluated the effects of one night CPAP application on BP and heart rate (HR) reactivity using non-invasive beat-to-beat BP measurement in normotensive and hypertensive subjects with OSAS. Methods: Finger arterial BP and oxygen saturation monitoring with nocturnal polysomnography were performed on 10 OSAS patients (mean age $52.2{\pm}12.4\;years$; 9 males, 1 female; respiratory disturbance index (RDI)>5) for one baseline night and another CPAP night. Beat-to-beat measurement of BP and HR was done with finger arterial BP monitor ($Finapres^{(R)}$) and mean arterial oxygen saturation ($SaO_2$) was also measured at 2-second intervals for both nights. We compared the mean values of cardiovascular and respiratory variables between baseline and CPAP nights using Wilcoxon signed ranks test. Delta ($\Delta$) BP, defined as the subtracted value of CPAP night BP from baseline night BP, was correlated with age, body mass index (BMI), baseline night values of BP, BP variability, HR, HR variability, mean $SaO_2$ and respiratory disturbance index (RDI), and CPAP night values of TWT% (total wake time%) and CPAP pressure, using Spearman's correlation. Results: 1) Although increase of mean $SaO_2$ (p<.01) and decrease of RDI (p<.01) were observed on the CPAP night, there were no significant differences in other variables between two nights. 2) However, delta BP tended to increase or decease depending on BP values of the baseline night and age. Delta systolic BP and baseline systolic BP showed a significant positive correlation (p<.01), but delta diastolic BP and baseline diastolic BP did not show a significant correlation except for a positive correlation in wake stage (p<.01). Delta diastolic BP and age showed a significant negative correlation (p<.05) during all stages except for REM stage, but delta systolic BP and age did not. 3) Delta systolic and diastolic BPs did not significantly correlate with other factors, such as BMI, baseline night values of BP variability, HR, HR variability, mean SaO2 and RDI, and CPAP night values of TWT% and CPAP pressure, except for a positive correlation of delta diastolic pressure and TWT% of CPAP night (p<.01). Conclusions: We observed that systolic BP and diastolic BP tended to decrease, increase or remain still in accordance with the systolic BP level of baseline night and aging. We suggest that BP reactivity by CPAP be dealt with as a complex phenomenon rather than a simple undifferentiated BP decrease.

  • PDF

Diagnosis of Obstructive Sleep Apnea Syndrome Using Overnight Oximetry Measurement (혈중산소포화도검사를 이용한 폐쇄성 수면무호흡증의 흡증의 진단)

  • Youn, Tak;Park, Doo-Heum;Choi, Kwang-Ho;Kim, Yong-Sik;Woo, Jong-Inn;Kwon, Jun-Soo;Ha, Kyoo-Seob;Jeong, Do-Un
    • Sleep Medicine and Psychophysiology
    • /
    • v.9 no.1
    • /
    • pp.34-40
    • /
    • 2002
  • Objectives: The gold standard for diagnosing obstructive sleep apnea syndrome (OSAS) is nocturnal polysomnography (NPSG). This is rather expensive and somewhat inconvenient, however, and consequently simpler and cheaper alternatives to NPSG have been proposed. Oximetry is appealing because of its widespread availability and ease of application. In this study, we have evaluated whether oximetry alone can be used to diagnose or screen OSAS. The diagnostic performance of an analysis algorithm using arterial oxygen saturation ($SaO_2$) base on 'dip index', mean of $SaO_2$, and CT90 (the percentage of time spent at $SaO_2$<90%) was compared with that of NPSG. Methods: Fifty-six patients referred for NPSG to the Division of Sleep Studies at Seoul National University Hospital, were randomly selected. For each patient, NPSG with oximetry was carried out. We obtained three variables from the oximetry data such as the dip index most linearly correlated with respiratory disturbance index (RDI) from NPSG, mean $SaO_2$, and CT90 with diagnosis from NPSG. In each case, sensitivity, specificity and positive and negative predictive values of oximetry data were calculated. Results: Thirty-nine patients out of fifty-six patients were diagnosed as OSAS with NPSG. Mean RDI was 17.5, mean $SaO_2$ was 94.9%, and mean CT90 was 5.1%. The dip index [4%-4sec] was most linearly correlated with RDI (r=0.861). With dip index [4%-4sec]${\geq}2$ as diagnostic criteria, we obtained sensitivity of 0.95, specificity of 0.71, positive predictive value of 0.88, and negative predictive value of 0.86. Using mean $SaO_2{\leq}97%$, we obtained sensitivity of 0.95, specificity of 0.41, positive predictive value of 0.79, and negative predictive value of 0.78. Using $CT90{\geq}5%$, we obtained sensitivity of 0.28, specificity of 1.00, positive predictive value of 1.00, and negative predictive value of 0.38. Conclusions: The dip index [4%-4sec] and mean $SaO_2{\leq}97%$ obtained from nocturnal oximetry data are helpful in diagnosis of OSAS. CT90${\leq}$5% can be also used in excluding OSAS.

  • PDF

A Study of Upper Airway Resistance Syndrome : Clinical and Polysomnographic Characteristics (상기도저항 증후군에 대한 연구 : 임상 및 수면다원검사 특징)

  • Yang, Chang-Kook;Clerk, Alex
    • Sleep Medicine and Psychophysiology
    • /
    • v.3 no.2
    • /
    • pp.32-42
    • /
    • 1996
  • Objectives : Upper airway resistance syndrome(UARS) is a sleep-related breathing disorder characterized by abnormal negative intrathoracic pressure during sleep. Abnormally increased negative intrathoracic pressure results in microarousal and sleep fragmentation which underlay UARS-associated complaints of daytime fatigue and sleepiness. Although daytime dysfunction in patients with UARS is comparable to that of sleep apnea syndrome, UARS has been relatively unnoticed in clinical setting. That is why UARS is apt to be excluded in diagnosing of sleep-related breathing disorders since its respiratory disturbance index and arterial oxygen saturation are within normal limits. The current study presents a summary of clinical and polysomnographic characteristics found in patients with UARS. The present study aims (1) to explore characteristics of patients diagnosed with UARS, (2) to characterize the polysomnographic findings of UARS patients, and (3) to enhance the understanding of UARS through those clinical and laboratory characteristics. Methods : This was a retrospective study of 20 UARS patients (male 15, female 5) and 30 obstructive sleep apnea (OSA) patients (male 21, female 9) at the Stanford Sleep Disorders Clinic. We diagnosed patients as having UARS when they met critenia, RDI < 5 characteristic findings of an elevated esophageal pressure($<-10\;cmH_2O$), frequent arousals secondary to an elevated esophageal pressure, and symptoms of daytime fatigue and sleepiness. We used polysomnographic value, which is standardized by Williams et al(1974), as normal control. Statiotical test were done with student t-tests. Results : (1) Mean age of UARS was $41.0\;{\pm}\;14.8$ years and OSA was $50.9\;{\pm}\;12.0$ years. UARS subject was significantly younger than OSA subject (p<0.05). (2) The total score of Epworth Sleepiness Scale (ESS) was UARS $9.7\;{\pm}\;6.3$ and OSAS $11.2\;{\pm}\;6.3$. There was no significant difference between two groups. (3) The mean body mass index was UARS $28.1\;{\pm}\;5.7\;kg/m^2$ and OSAS $32.9\;{\pm}\;7.0\;kg/m^2$. UARS had significantly lower meen body man index than OSAS subjects (p<0.05). (4) The polysomnographic parameters of UARS were not significantly different from those of OSA except RDI(p<0.001), $SaO_2$ (p<0.001) and slow wave sleep latency (p<0.05). (5) Compared with normal control, Total sleep time in UARS subjects was significantly shorter (p<0.001), sleep efficiency index was significantly lower (p<0.001), total awakening percentage was significantly higher (p<0.001), and sleep stage 1 (p<0.001) were significantly higher. (6) OSA patients showed poor sleep quality and distinct abnormal sleep architectures compared with normal control. Conclusions : Conclusions from the above results are as follows : (1) UARS patients were younger and had lower body mass index when umpared with OSA patients. (2) The quality of sleep and sleep architectures of the UARS and OSA patients are significantly different from those of normal control. (3) ESS scores and awakening frequencies of UARS are similar with those of OSA, suggesting that daytime dysfunction of UARS patients may be comparable to those of OSA patients. (4) The RDI and the $SaO_2$ which are important indicators in diagnosing sleep-related breathing disorders, of UARS subjects are close to normal value. (5) According to the the above results, we unclude that despite the absence of $SaO_2$ drops and the absence of an elevated number of apnea and hypopnea, subjects developed clinical complaints which were associated with laborious breathing, elevated Pes nadir, and frequently snoring. (6) Accordingly, we suggest including LIARS in the differential diagnosis list when sleep related breathing disorder is suspected clinically and overnight polysomnographic findings except snoring and frequent microarousal are within normal limits.

  • PDF

Effect of adenotonsillar hypertrophy on right ventricle function in children

  • Lee, Jin Hwan;Yoon, Jung Min;Lim, Jae Woo;Ko, Kyung Og;Choi, Seong Jun;Kim, Jong-Yeup;Cheon, Eun Jung
    • Clinical and Experimental Pediatrics
    • /
    • v.57 no.11
    • /
    • pp.484-488
    • /
    • 2014
  • Purpose: Chronic upper airway obstruction causes hypoxemic pulmonary vasoconstriction, which may lead to right ventricle (RV) dysfunction. Adenotonsillar hypertrophy (ATH) is the most common cause of upper airway obstruction in children. Therefore, we aimed to evaluate RV function in children with ATH. Methods: Twenty-one children (male/female, 15/6; mean age, $92.3{\pm}39.0$ months; age range, 4-15 years) with ATH and 21 healthy age- and gender-matched controls were included in this study. Tricuspid annular plane systolic excursion and RV myocardial performance index were measured by transthoracic echocardiography. Further, the plasma level of N-terminal of probrain natriuretic peptide (NT-proBNP), an indicator of RV function, was determined. Results: The snoring-tiredness during daytime-observed apnea-high blood pressure (STOP) questionnaire was completed by the patients' parents, and loud snoring was noted in the ATH group. The plasma NT-proBNP level was significantly higher in the ATH group than that in the controls ($66.44{\pm}37.63pg/mL$ vs. $27.85{\pm}8.89pg/mL$, P=0.001). The echocardiographic parameters were not significantly different between the groups. Conclusion: We were unable to confirm the significance of echocardiographic evidence of RV dysfunction in the management of children with ATH. However, the plasma NT-proBNP level was significantly higher in the ATH group than that in the control, suggesting that chronic airway obstruction in children may carry a risk for cardiac dysfunction. Therefore, more patients should be examined using transthoracic echocardiography. In addition, pediatricians and otolaryngologists should consider cardiologic aspects during the management of children with severe ATH.

Comparison for the Optimal Pressure between Manual CPAP and APAP Titration with Obstructive Sleep Apnea Patients (한국인 폐쇄성 수면 무호흡 환자의 적정 양압을 위한 수동화 양압 측정법과 자동화 양압 측정법의 비교)

  • Kim, Dae Jin;Choi, Byoung Geol;Cho, Jae Wook;Mun, Sue Jean;Lee, Min Woo;Kim, Hyun-Woo
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.51 no.2
    • /
    • pp.191-197
    • /
    • 2019
  • Although auto-adjusting positive airway pressure (APAP) titration at home has several advantages over a CPAP titration in terms of convenience and time saving, there are still concerns as to whether it will show corresponding accuracy when compared to laboratory-based polysomnography (PSG) and CPAP titration. To obtain more evidence supporting home-based auto-titration, APAP titration was performed at home for patients who were presented with OSA on laboratory-based diagnostic PSG followed by CPAP titration. A total of 79 patients were included in the study. They all underwent split-night PSG with CPAP titration, and APAP titration for more than 7 days. The patients with successful titration at both situations were selected. The optimal pressure and apnea-hypopnea index (AHI) of CPAP and APAP titration were compared. The optimal pressure for CPAP and APAP titration were $7.0{\pm}1.8cmH_2O$ and $7.6{\pm}1.6cmH_2O$ (P<0.001), whereas the corresponding AHI were $1.3{\pm}1.5/h$ and $3.0{\pm}1.7/h$ (P<0.001). As a result, the achievement rates of optimal pressure for CPAP and APAP titration were 96.2% and 94.9% (r=-0.045, P=0.688), respectively. The results of this study did not differ with regard to the optimal pressure between CPAP and APAP titration. Overall, CPAP and APAP titrations should be chosen depending on a required situation.

A Literature Study of Samguchup - Based on the Traditional Chinese Medical Journal - (삼구첩(三九貼)에 관한 문헌적 고찰 - 중의학 잡지를 중심으로 -)

  • Lee, Sun Haeng;Kim, Cho Young;Chang, Gyu Tae
    • The Journal of Pediatrics of Korean Medicine
    • /
    • v.26 no.4
    • /
    • pp.1-9
    • /
    • 2012
  • Objectives: The Samguchup is a plaster therapy in winter to prevent and treat diseases occurring frequently in the winter. Studies on samguchup published in China were analyzed for our study in order to utilize in Korea. Methods: 15 studies with keywords such as 'Sanjiutie' or 'Dongbingdongzhi' published in CAJ (China Academic Journal) until July 31, 2012 were compared, in terms of clinical effects, herbs, acupoints, attatching time, and accompanying treatment. Results: Treatment rate ranged from 65% to 92.65%, in recurrent respiratory infection, cough, allergic rhinitis, asthma, chronic bronchitis, chronic obstructive pulmonary disease, sleep apnea, and rheumatic arthritis. The herbs used more than 5 times were Semen Sinapis Albae, Herba Asari, Ginger juice, Radix Kansui, and Rhizoma Corydalis. The acupoints used more than 5 times were BL13, BL23, GV14, CV17, CV22, and EX-B1. The attaching time were usually 4 hours, but shorter for child. The Sambokchup, Korean medicine, moxibustion on ginger, drug(western medicine), injection, and inhalation were used as accompanying treatment. Conclusions Appropriate use of Samguchup is necessary to treat or prevent diseases in winter.

Relationships between Respiratory Diseases and Safety of Pediatric Dental Sedation (소아의 호흡기 질환과 안전한 치과진정법의 연관성)

  • Chung, Woojin;Jeong, Taesung
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.42 no.4
    • /
    • pp.327-330
    • /
    • 2015
  • The safety and success of dental sedation for children depend mainly on respiratory status of patients. A special condition, that is, nasal breathing in supine position with their oral airway blocked by rubber dam, should be considered. Therefore, irrespective of medical consultation, pediatric dentists themselves should do respiratory assessment especially adenotonsillar hypertrophy, nasal obstruction, posterior nasal drainage and airway hypersensitivity. Patients with sinusitis, allergic rhinitis, asthma, snoring and OSAS(obstructive sleep apnea syndrome) can induce the sedation failure and complete management of these can improve the safety of dental sedation.

Voice Changes after Uvulopalatopharyngoplasty (구개수구개인두성형술 이후의 음성변화)

  • 손영익;김선일;윤영선;추광철;정원호
    • Journal of the Korean Society of Laryngology, Phoniatrics and Logopedics
    • /
    • v.9 no.1
    • /
    • pp.22-26
    • /
    • 1998
  • Uvulopalatopharyngoplasty(UPPP) is one of the most popular surgical procedure for the treatment of obstructive sleep apnea syndrome(OSAS) occurring at the level of oropharynx. However, voice changes after UPPP have been a challenging issue for the professional voice users, because even minor changes in voice quality or articulation may be critical to professional singers, teachers, and so on. Several acoustic changes after UPPP have been proposed. However, based on the authors understanding, there is no report about voice changes after UPPP in Korean. We measured the first, second and third formant frequencies of /a/, /i/, /u/ phonations in 20 adult male patients who had undergone UPPP surgery, and the nasalances of Rabbit, Baby, and Mama passages. These parameters were measured preoperatively, at 1 month and 3 months after the operation. Any subjective voice changes were asked to be reported at the posto-perative visits. The third formant(F3) of /u/ phonation was significantly reduced at postoperative 1 month measurement. The nasalance of Mama passage was singnificantly increased at postoperative 3 months measurement. No one complained of subjective changes in voice quality, timbre, articulation or speech. Even though there are no complaints about postoperative voice changes subjectively, significant changes in the formant characteristics of certain vowel and changes in the nasality after UPPP require the clinicians to be mort cautious and careful in deciding UPPP for the professional voice users.

  • PDF