• 제목/요약/키워드: oblique distance

검색결과 105건 처리시간 0.024초

하악골 운동시 과두의 이동범위에 관하여 (THE NORMAL RANGE OF CONDYLAR MOVEMENT)

  • 최한업
    • 치과방사선
    • /
    • 제8권1호
    • /
    • pp.43-47
    • /
    • 1978
  • The purpose of this study was to investigate the normal range of condylar movement of normal adults. The author has observed roentgenographic images of four serial positions of condylar head taken by modified transcranail lateral oblique projection. The serial positions are centric occlusion, rest position, 1 inch open position and maximal open position. The results were obtained as follow; 1. Inter-incisal distance was 46.85㎜ in maximal open position. 2. The length between the deepest point of glenoid fossa and summit of condylar head in rest position was wider than that in centric occlusion by 0.8㎜. 3. In 1 inch open position, condylar head moved forward from the standard line in 12.64㎜ of horizontal direction and moved downwards from the standard line in 1.84㎜ of vertical direction. 4. In maximal open position, condylar head moved forward from the standard line in 19.06㎜ of horizontal direction and moved downwards from thestanard line in 0.4㎜ of vertical direction. 5. In centric occlusion, the width between glenoid fossa and margin of condylar head was greater in the posterior portion than in the anterior portion by 0.4㎜. 6. Except for the estimated figures of 1 inch open position, all of the estimated figures was greater in male than in female.

  • PDF

충돌제트계에서 사다리형 로드 배열에 의한 열전달촉진에 관한 연구 (Heat Transfer Enhancement by Trapezoid Rod Array in Impinging Jet System)

  • 임태수;금성민
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 추계학술대회논문집B
    • /
    • pp.260-267
    • /
    • 2001
  • The objective of this study was to investigate the characteristics of jet flow and heat transfer caused by trapezoid rods array in impinging jet system. In this study, trapezoid rods have been set up in front of flat plate to serve as a turbulence promoter. The bottom width of trapezoid rod was W=4, 8mm and oblique angle were $80^{\circ}$. The space from rods to the heating surface was C=1, 2, 4mm, the pitch between each rods was P=30, 40, 50mm, and the distance from nozzle exit to flat plate was H=100, 500mm. This results were compared with the case without trapezoid rods. As a result, when rods are installed in front of the impinging plate, the acceleration of the jet flow and the eddies due to the rods seem to contribute to the heat transfer enhancement. Among test conditions, the heat transfer performance was best for the condition of W=8mm, C=1mm, P=30mm and H/B=10. The maximum heat transfer rate is about 1.9 times larger than that without trapezoid rods.

  • PDF

A Simulation Tool for Ultrasonic Inspection

  • Krishnamurthy, Adarsh;Mohan, K.V.;Karthikeyan, Soumya;Krishnamurthy, C.V.;Balasubramaniam, Krishnan
    • 비파괴검사학회지
    • /
    • 제26권3호
    • /
    • pp.153-161
    • /
    • 2006
  • A simulation program SIMULTSONIC is under development at CNDE to help determine and/or help optimize ultrasonic probe locations for inspection of complex components. SIMULTSONIC provides a ray-trace based assessment for immersion and contact modes of inspection. The code written in Visual C++ operating in Microsoft Windows environment provides an interactive user interface. In this paper, a description of the various features of SIMULTSONIC is given followed by examples illustrating the capability of SIMULTSONIC to deal with inspection of canonical objects such as pipes. In particular, the use of SIMULTSONIC in the inspection of very thin-walled pipes (with 450 urn wall thickness) is described. Ray trace based assessment was done using SIMULTSONIC to determine the standoff distance and the angle of oblique incidence for an immersion mode focused transducer. A 3-cycle Hanning window pulse was chosen for simulations. Experiments were carried out to validate the simulations. The A-scans and the associated B-Scan images obtained through simulations show good correlation with experimental results, both with the arrival time of the signal as well as with the signal amplitudes.

Reflection Seismology in the Southern Ayu Trough, a Slow-spreading Divergent Boundary

  • Hong, Jong-Kuk;Lee, Sang-Mook
    • Ocean and Polar Research
    • /
    • 제24권3호
    • /
    • pp.189-196
    • /
    • 2002
  • A multichannel seismic survey was conducted in the southern Ayu Trough which is the only spreading boundary between the Philippine Sea and Caroline plates. The seismic system used in this study comprises of 2.46-l sleeve gun and a 12-channel streamer with a group interval of 6.25m. Migration technique was used to analyze seismic velocity, and poststack depth migration was applied to the stacked data. The sediment thickness obtained from the depth section tends to increase with distance from the spreading axis. Sedimentation rates are poorly constrainted in the study area. The apparent half-spreading rates estimated from the sediment thickness and sedimentation rate from DSDP hole on the caroline plate are 4.7mm/yr and 7.9mm/yr at $1^{\circ}24'N\;and\;0^{\circ}42'N$, respectively, which are fester than Previously suggested. On the basis of new oblique spreading geometry, the recalculated spreading rates are 5.4mm/yr and 9.1mm/yr at $1^{\circ}24'N\;and\;0^{\circ}42'N$, respectively. Seismic sections show that the topography is asymmetric across the Ayu Trough and the acoustic basement is rough. These features are consistent with the earlier suggestion that the Ayu Trough is a slow-spreading divergent boundary. A detailed examination of seismic profiles away from the axis shows that sediments can be divided into two layers which implies a possible change in the spreading rate anuor sedimentation condition during the formation of the trough.

하악(下顎) 제1대구치(第一大臼齒)의 맹출과정(萌出過程)에 관(關)한 연구(硏究) (THE STUDY OF THE ERUPTION PATTERN OF THE MAMDIBULAR FIRST PERMANENT MOLAR)

  • 황의강
    • 대한소아치과학회지
    • /
    • 제3권1호
    • /
    • pp.19-31
    • /
    • 1976
  • To study the eruption pattern of the mandibular first permanent molar, the author took 263 cases of Oblique Cephalogram from age 3 to 6 years old children and observed the vertical and mesiodistal directional change and tooth axis change. The following results were obtained.; 1. The eruption pattern of the mandibular first permanenl molar was changed at about 60~66 months or calcification stage IX. 2. At the early stage, the path of eruption of the mandibular first permanent molar directed upward and forward and after calcification stage IX it changed to the direction of upward. 3. The height of the alveolar bone of the upper part of the mandibular first permanent molar was almost equal to that of the interseptal bone of the first and second deciduous molar, but the height showed gradual descent afterwards. 4. At the early stage, the distance from the distal end of the mandibular second deciduous molar to the anterior portion of the ascending ramus was 1.2~1.4 times larger than the mesio-distal diameter of the mandibular first permanent molar, but at the later stage it was enlarged 1.7~1.9 times larger than the mesiodistal diameter of the mandibular first permanent molar.

  • PDF

충돌제트계에서 사다리형 로드 배열에 의한 열전달 및 유동특성 (Heat Transfer and Flow Characteristics by Trapezoid Rod Array in Impinging Jet System)

  • 금성민
    • 설비공학논문집
    • /
    • 제13권9호
    • /
    • pp.904-913
    • /
    • 2001
  • The objective of this study was to investigate the characteristics of jet flow and heat transfer caused by trapezoid rods array in impinging jet system. In this study, trapezoid rods have been set up in front of flat plate to serve as a turbulence promoter. The bottom width of trapezoid rod was W=4, 8 mm and oblique angle were 80$^{\circ}$. The space from rods to the heating surface was C=1, 2, 4 mm, the pitch between each rods was P=30, 40, 50 mm, and the distance from nozzle exit to flat plate was H=100, 500 mm. This results were compared with the case without trapezoid rods. As a result, when rods are installed in front of the impinging plate, the acceleration of the jet flow and the eddies due to the rods seem to contribute to the heat transfer enhancement. Among test conditions, the heat transfer performance was best for the condition of W=8 mm, C=1 mm, P=30 mm and H/B=10. The maximum heat transfer rate is about 1.9 times larger than that without trapezoid rods.

  • PDF

Design of Multipurpose Phantom for External Audit on Radiotherapy

  • Lim, Sangwook
    • 한국의학물리학회지:의학물리
    • /
    • 제32권4호
    • /
    • pp.122-129
    • /
    • 2021
  • Purpose: This study aimed to design a multipurpose dose verification phantom for external audits to secure safe and optimal radiation therapy. Methods: In this study, we used International Atomic Energy Agency (IAEA) LiF powder thermoluminescence dosimeter (TLD), which is generally used in the therapeutic radiation dose assurance project. The newly designed multipurpose phantom (MPP) consists of a container filled with water, a TLD holder, and two water-pressing covers. The size of the phantom was designed to be sufficient (30×30×30 cm3). The water container was filled with water and pressed with the cover for normal incidence to be fixed. The surface of the MPP was devised to maintain the same distance from the source at all times, even in the case of oblique incidence regardless of the water level. The MPP was irradiated with 6, 10, and 15 MV photon beams from Varian Linear Accelerator and measured by a 1.25 cm3 ionization chamber to get the correction factors. Monte Carlo (MC) simulation was also used to compare the measurements. Results: The result obtained by MC had a relatively high uncertainty of 1% at the dosimetry point, but it showed a correction factor value of 1.3% at the 5 cm point. The energy dependence was large at 6 MV and small at 15 MV. Various dosimetric parameters for external audits can be performed within an hour. Conclusions: The results allow an objective comparison of the quality assurance (QA) of individual hospitals. Therefore, this can be employed for external audits or QA systems in radiation therapy institutions.

정수생태계 동물플랑크톤 채집 시 네트 인양 유형 및 수심에 따른 군집 정보 비교 (A Comparative Study on the Information of Zooplankton Community Based on Towing Type and Depth in the Lake Ecosystems)

  • 오혜지;채연지;구도영;김유진;왕정현;최보형;지창우;곽인실;박영석;남귀숙;김용재;장광현
    • 생태와환경
    • /
    • 제53권4호
    • /
    • pp.365-373
    • /
    • 2020
  • 호소 생태계에 대한 생물측정망 조사 및 평가지침은 동물플랑크톤 조사의 편의성을 고려하여 출현 종 수와 개체군 밀도, 군집 지수 등을 상대적으로 비교하기 위해 수심 5m 이하의 얕은 호소-수변부에서 사선끌기, 수심 20 m 이상 호소-전수심 수직끌기, 그 이상의 깊은 호소-20 m까지의 수심을 대상으로 한 수직끌기를 제시하고 있다. 본 연구에서는 지침에서 제시하는 방법 중 사선끌기법과 20 m 수직 끌기법을 각각 전수심을 대상으로 한 조사 방법과 비교하여 동물플랑크톤 군집 정보의 차이 및 특성에 대해 분석하였다. 군집 지수의 경우 수심이 얕은 호수에서의 사선끌기법/수직끌기법 비교에서는 차이를 보이지 않은 반면, 수심이 깊은 호소에서는 끌기 수심을 20 m로 제한할 경우보다 전수심 수직끌기를 적용했을 때 다양도 및 풍부도 지수가 상승하는 것으로 나타났다. 또한, 사선끌기 및 20 m 수직끌기를 통해 채집한 동물플랑크톤 시료로부터 표면~저층 상층부까지의 전수심을 채집 대상으로 설정한 경우보다 약 3배 정도 높은 개체군 밀도가 계산되어, 동물플랑크톤 총 개체 밀도가 크게 과대 평가되는 것으로 나타났다. 이러한 차이는 동물플랑크톤 수직 분포 특성상 발생하는 수층별 동물플랑크톤 개체 밀도 차이 및 여과된 원수량의 차이에서 비롯된 결과로 판단되며, 이에 따라 호소를 대변하여 수체 간 또는 수체 내 변동을 보다 정확히 파악하고 호 내 2차 생산과 관련한 기능적 정량 지표로서 동물플랑크톤 군집 정보의 활용을 고려할 경우, 수심에 따른 개체군 밀도 분포와 전체 개체수 환산 시 수층별 기여율을 고려한 전수심 수직끌기 방법의 적용이 보다 적절할 것으로 분석되었다.

연령에 따른 원·근거리 난시의 굴절력 변화에 대한 연구 (A Study for the Change and Distribution of Far Sighted and Near Sighted Astigmatism Power according to Age)

  • 주석희;박성종
    • 한국안광학회지
    • /
    • 제12권2호
    • /
    • pp.25-36
    • /
    • 2007
  • 이 연구는 안질환이 없고 눈 수술의 경험이 없는 1,598안(남 698안, 여 900안)을 대상으로 양안 개방형 자동굴절검사 기기를 이용한 검사를 실시하여, 5세에서 67세 사이의 12개 연령 군으로 나누어 각각 원거리, 근거리 상태에서의 연령별 난시 굴절력 분포와 원거리에서 근거리로 주시선이 이동할 때 난시 굴절력 변화를 비교 분석하였다. 그 결과 원거리 난시의 평균 굴절력은 전체난시에서 직난시가 -0.79D, 각막난시에서 직난시가 -1.07D, 잔여난시에서 도난시가 -0.79D로 각각 가장 높게 나타났다. 원거리에서 각막난시와 전체난시의 상관관계는 y=0.7493 x + 0.5661 r=0.6510, 잔여난시와 전체난시의 상관관계는 y=0.248 x - 0.5926 r=0.2598, 각막난시와 잔여난시의 상관관계는 y=-0.4439 x - 0.1813 r=-0.5551 을 나타냈다. 전체난시는 잔여난시보다 각막난시의 변화와 관계가 크며, 난시성분별 상관관계는 전체난시와 각막난시의 상관성이 가장 높게 나타났다. 근거리 난시의 평균 굴절력은 전체난시에서 직난시가 -0.92D, 각막난시에서 직난시가 -1.12D, 잔여난시에서 도난시가 -0.87D로 각각 가장 높게 나타났다. 근거리에서 각막난시와 전체난시의 상관관계는 y=0.6872 x + 0.5934 r=0.6204, 잔여난시와 전체난시의 상관관계는 y=0.303 x - 0.6066 r=0.3165, 각막난시와 잔여난시의 상관관계는 y=-0.46 x - 0.0626 r=-0.5322을 나타냈다. 근거리전체난시는 잔여난시 보다 각막난시의 변화와 관계가 크며, 난시성분별 상관관계는 각막난시와 전체난시의 상관성이 가장 높게 나타났다. 원거리에서 근거리 주시 시 난시 성분별 굴절력 차이는 전체난시 $-0.07D{\pm}0.44D$, 각막난시 $-0.04D{\pm}0.54D$, 잔여난시 $0.01D{\pm}0.53D$ 차이로 잔여난시의 사난시를 제외하고는 근거리에서 대부분 난시굴절력이 증가하는 것으로 나타났다, 원거리에서 근거리 주시 시 난시굴절력의 변화가 있는 경우가 전체난시 540안 (33.7%), 각막난시 638안(39.9%), 잔여난시 841안(52.6%)으로 나타났다.

  • PDF

임플란트 고정체의 나사산 형태와 하중조건에 따른 응력분석 (Finite Element Stress Analysis of the Implant Fixture According to the Thread Configuration and the Loading Condition)

  • 안옥주;정제옥;김창현;강동완
    • 구강회복응용과학지
    • /
    • 제21권2호
    • /
    • pp.153-167
    • /
    • 2005
  • The purpose of this study was to compare the v-shape thread with the square shape thread of fixture in the view of stress distribution pattern using finite element stress analysis. The finite element model was designed with the parallel placement of two standard fixtures(4.0 mm diameter ${\times}$ 11.5 mm length) on the region of mandibular 1st and 2nd molars. Three dimensional finite element model was created with the components of the implant and surrounding bone. This study simulated loads of 200 N at the central fossa in a axial direction (load A), 200 N at the buccal offset load that is 2 mm apart from central fossa in a axial direction (load B), 200 N at the buccal offset load that was 4 mm apart from central fossa in a axial direction (load C). These forces of load A',B',C' were applied to a $15^{\circ}$ inward oblique direction at that same site with 200 N. Von Mises stress values were recorded and compared in the supporting bone, fixture, and abutment screw. The following results have been made based on this study : 1. The highest stress concentration occurred at the cervical region of the implant fixture. 2. Von Mises stress value of off-site region was higher than that of central fossa region. 3. Square shape thread type showed more even stress distribution in the vertical and oblique force than V-shape thread type. 4. Stress distribution was the most effective in the case of buccal offset load (2, 4 mm distance from central fossa) in the square shape thread type. 5. V-shape thread type revealed higher von Mises stress value than square shape thread type in all environmental condition. The results from numerical analyses concluded that square shape thread type had the lower destructive stress and more stress distribution between the fixture and bone interface than V-shape thread type. Therefore, square shape thread type was regarded as optimal thread configuration in biomechanical concepts.