• Title/Summary/Keyword: oblique

Search Result 1,727, Processing Time 0.024 seconds

Transient Inferior Oblique Muscle Palsy Following Transconjunctival Lower Lid Blepharoplasty

  • Lee, Hye Jin;Rhiu, Soolienah;Oh, Dong Eun;Jeong, Jin Ho
    • Kosin Medical Journal
    • /
    • v.33 no.2
    • /
    • pp.208-214
    • /
    • 2018
  • Although the inferior oblique (IO) muscle is positioned considerably deep in the orbit, transconjunctival lower lid blepharoplasty may affect it and transient or permanent IO muscle palsy might result. Therefore diplopia should be explained before cosmetic blepharoplasty performed with transconjunctival approach.

Development of a Helical Type Drum with an Oblique Cutting Condition for the Sawdust Machine (톱밥 제조기용 3차원 절삭 헬리컬형 드럼의 개발)

  • Oh, Sang-Yeob;Bae, Yong-Hwan;Ha, Min-Su
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.7 no.4
    • /
    • pp.419-424
    • /
    • 2004
  • In order to increase the efficiency of the sawdust machine, the helical type drums with an oblique cutting condition (3D) were developed. The preexisting drums have an orthogonal cutting condition (2D) considering of a saw cutter and a wood cutting pattern. Unfortunately, the disadvantages of this type drum are the big cutting resistance, the high cost of a cutting power and the extreme occurrence of a vibration. To improve this shortcoming, the helical type drum with an oblique cutting condition was developed. Therefore, this type drum decreased the vibration and the cutting resistance of the sawdust machine, and also improved the productivity of 30% or more and the porosity of the sawdust.

  • PDF

Oblique-angle sputtering에 의한 Indium tin oxide 이중층 반사방지막 특성에 관한 연구

  • Kim, Yong-Jun;Le, Anh Huy Tuan;Kim, Seon-Bo;Lee, Jun-Sin
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2016.02a
    • /
    • pp.297.1-297.1
    • /
    • 2016
  • 높은 굴절률(n_H) 의 ITO films 위에 homoepitaxial 성장 기술로 낮은 굴절률(n_L) 의 ITO를 이중으로 증착한 반사방지막을 연구하였다. 우리는 기판 상에 vapor flux 입사 각도 및 columnar 성장막과 경사각 사이의 상관 관계에 기초하여 낮은 굴절률의 ITO 박막을 Oblique-angle sputtering을 사용하여 증착하였다. Oblique-angle 증착동안 columns 경사각이 incident flux angle 의 증가에 따라 linear 하게 증가했다. 반대로 incident flux angle 이 증가할때 ITO 박막의 굴절률은 현저하게 감소하였는데, 이는 원자의 shadowing effect와 표면 diffusion으로 인하여 필름내의 porosity를 증가시킨 것으로 보여진다. 이러한 결과로 homoepitaxial으로 성장시킨 ITO 이중층 구조 반사방지막 특성이 향상되었으며, 유리 기판 위에서 weight average reflectance가 n_L=1.72, n_H=1.90 에서 6.57%를 달성하였다.

  • PDF

Correction of Bilateral Tessier No. 2, 3, and 12 Facial Cleft with Anopthalmia

  • Moon, Seong-Yong;Kim, Seong-Gon;Park, Young-Ju;Park, Young-Wook
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.35 no.4
    • /
    • pp.243-247
    • /
    • 2013
  • Oblique facial cleft is a rare congenital deformity. Its incidence has been reported as 0.24% of all reported cases of facial cleft. We report on a patient who had a left-sided oblique facial cleft with anopthamia, including lip and palate, nose alar base, and medial canthus. The patient also had a right-sided oblique facial cleft, which included lip and palate, nose alar base, medial canthus, and upper eye brow. Primary closure of the facial cleft was performed using multiple Z-plasty after excision of scar tissue.

THE STUDY OF THE INTERPRETATION OF THE TMJ RADIOGRAPHY USING SUBTRACTION TECHNIQUE (Subtraction법을 이용한 악관절 X-선사진 판독에 관한 연구)

  • Na Choon-Wha;Yoo Dong-Soo
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.17 no.1
    • /
    • pp.175-181
    • /
    • 1987
  • The purpose of this study is to know the value of the photographic subtraction technic in the transcranial oblique lateral projection of the TMJ. The author examined the transcranial oblique lateral projection radiographs which comprise 50 cases of 32 persons, compared the transcranial oblique lateral projection films and those subtraction films. The following results were obtained. 1) The condyle at closed jaw position had showed a reversed tone image, but the condyle at the opening position had showed a re-reversed ordinary image. Both condyles had showed one subtraction film because radiographic interpretation of TMJ was easy. 2) On 50 cases of subtraction films, 46 cases had showed same radiographic images compared with trascranial oblique lateral projection films. Four cases (3 cases of erosion, 1 cases of sclerosis) had showed additional changes of images so that capability of interpretation was improved.

  • PDF

Development of a Helical Type Drum with Oblique Cutting Condition for Sawdust Machine (톱밥 제조기용 3차원 절삭 헬리컬형 드럼의 개발)

  • 오상엽;배용환
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2004.04a
    • /
    • pp.88-92
    • /
    • 2004
  • We developed a helical type drum with an oblique cutting condition for sawdust machine. The existing drum has an orthogonal cutting(2D) condition considering of saw cutter and wood cutting pattern. Additional disadvantage of this type include big cutting resistance, high cost of cutting power and extreme occurrence of vibrations. To improve this shortcoming, we developed a helical type drum with an oblique cutting(3D) condition, therefore, this type drum decreased the vibration and cutting resistance of sawdust machine, and also improved productivity and sawdust porosity.

  • PDF

Activation of Trunk Muscles during Stabilization Exercises in Four-point Kneeling (네발기기 자세에서 실시하는 안정화 운동에 따른 체간 근육의 활성도)

  • Lee, Hyun-Ok
    • The Journal of Korean Physical Therapy
    • /
    • v.22 no.5
    • /
    • pp.33-38
    • /
    • 2010
  • Purpose: This study examined the activation of the rectus abdominis (RA), external abdominal oblique (EO), transversus abdominis, internal abdominal oblique (TrA/IO), and Multifidus (MF) muscles while stabilization exercise was performed in a four-point kneeling position. Methods: Experiments were conducted on 21 healthy male adults (mean age=25.29 years) who voluntarily agreed to participate in the study. Each subject was instructed regarding maximal voluntary contractions (MVC) and stabilization exercise in four-point kneeling. While MVC and stabilization exercise of individual muscles were being performed, activation of the muscles was measured using surface electromyography (EMG). Activation of the muscles while performing stabilization exercise in four-point kneeling was normalized to a percentages of the MVC. Results: Left RA, right TrA/IO, right and left MF muscles showed significant differences among the positions. Conclusion: Selecting an optimal position can aid subjects on physical conditions while performing stabilization exercises in the four-point kneeling position.

Echelon Feeder of Brown Rice for On-line Inspection Using Image Processing (영상처리식 온라인 품위판정을 위한 현미의 정렬공급장치)

  • Kim, Tae-Min;Noh, Sang-Ha
    • Journal of Biosystems Engineering
    • /
    • v.35 no.3
    • /
    • pp.197-205
    • /
    • 2010
  • An automatic echelon feeder of brown rice was presented for quality inspection system using color image processing. A echelon feeder was developed with vibratory feeder and cylindrical indent singulator having oblique light. The vibratory feeder consisted of a hopper, electromagnetic vibrator and multichannel grooves and supply the grain sample to the singulator. The feeding performance such as feed rate, blocking frequency of the channel was dependent on the size of groove and vibration pattern. A cylindrical indent singulator consisted of a rotating cylinder, prisms and a tungsten-halogen light source. It delivered grain kernels under the camera in a echelon form and illuminate the kernels with oblique ray and ambient light. The size of the indents installed on the surface of the rotating cylinder was determined by the dimensions of the paddy and a small triangular prism was placed in each indent to apply $ 20^{\circ}$ oblique light to the grain kernel.

Transdiscal Superior Hypogastric Plexus Block with the Patient in Oblique Position -A case report- (사위에서 행한 경추간판적 상하복신경총 차단)

  • Shim, Jae-Chol;Kim, Dong-Won;Jeon, Young-Seok;Won, Seok-Kyu;Lee, Myoung-Eui
    • The Korean Journal of Pain
    • /
    • v.10 no.1
    • /
    • pp.93-96
    • /
    • 1997
  • Block of superior hypogastric plexus has been advocated as a useful technique in the palliation of various of pelvic pain syndromes. This technique has been performed under fluroscopic or CT guidance using bilateral placement of needles. We performed a modification of transdiscal approach with the patient in oblique position permitting successful superior hypogastric plexus block using a single needle placed under fluoroscopic guidance. Our experience suggest transdiscal approach performed in oblique position allows easier, safer, and more accurate needle placement for superior hypogastric plexus block.

  • PDF

Effects of Fluid Resistance Coefficient on Wave Characteristics around Permeable Submerged Breakwater

  • Kim, Namhyeong;Woo, Sumin;Ko, Yongsu
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2014.06a
    • /
    • pp.244-245
    • /
    • 2014
  • Recently, the studies on submerged breakwater are increased due to needs considering the quality of water and the scenic view. In this paper, waves coming to permeable submerged breakwater coming with oblique angle are computed numerically by using wave pressure function. The wave pressure function throughout the analytical region including the fluid and submerged breakwaters is used. An unknown quantity expressed by the wave pressure function is simulated by boundary element method. The maximum reflection coefficient shows the tendency of decrease with the increase of oblique angle and The reflection coefficient shows the tendency of increase with the increase of the values of the linear dissipation coefficient and the added mass coefficient. It is means that the reflection coefficients are strongly dependent on the oblique angle and resistance coefficients.

  • PDF