• Title/Summary/Keyword: nuclear fuel fretting

Search Result 63, Processing Time 0.026 seconds

A Comparison of Fretting Wear Characteristics of Zircaloy-4 Tube in Light Water and in Air (경수 및 공기중에서의 지르칼로이-4 튜브의 프레팅 마멸특성 비교)

  • 조광희;김태형;김석삼
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 1999.06a
    • /
    • pp.303-309
    • /
    • 1999
  • The fretting wear behaviour of Zircaloy-4 tube used as the fuel rod cladding in PWR nuclear power plants has been investigated at the different test environment, in light water and in air as a function of slip amplitude, normal load, test duration and frequency. Zircaloy-4 tubes were used for both of oscillating and stationary specimens. A fretting wear tester was designed to be suitable for this fretting test. The wear volume and specific wear rate of Zircaloy-4 tube in water were greater than those in air under various slip amplitude. It was found that delaminate debris and surface cracks were observed at low slip amplitude and high load in water Experimental results showed that the light water accelerated the wear of Zircaloy-4 tube at low slip amplitude in fretting.

  • PDF

Comparison of Fretting Wear Characteristics of Zircaloy-4 Tube in Light Water and in Air (지르칼로이-4 튜브 프레팅 마멸 특성의 환경 의존성과 마멸기구)

  • 조광희;김석삼
    • Tribology and Lubricants
    • /
    • v.15 no.1
    • /
    • pp.83-89
    • /
    • 1999
  • The fretting wear behaviour of Zircaloy-4 tube used as the fuel rod cladding in PWR nuclear power plants has been investigated at the different test environment, in light water and in air as a function of slip amplitude, normal load, test duration and frequency. Zircaloy-4 tubes were used for both of oscillating and stationary specimens. A fretting wear tester was designed to be suitable for this fretting test. The wear volume and specific wear rate of Zircaloy-4 tube in water was greater than those in air under various slip amplitude. Delaminates and surface cracks were observed at low slip amplitude and high load of fretting test in water, but the traces of adhesion and plowing were observed at and above 200 Um. The water accelerates the wear of Zircaloy-4 tube at lower slip amplitude in fretting.

Fretting Wear Mechanisms of Zircaloy-4 and Inconel 600 Contact in Air

  • Kim, Tae-Hyung;Kim, Seock-Sam
    • Journal of Mechanical Science and Technology
    • /
    • v.15 no.9
    • /
    • pp.1274-1280
    • /
    • 2001
  • The fretting wear behavior of the contact between Zircaloy-4 tube and Inconel 600, which are used as the fuel rod cladding and grid, respectively, in PWR nuclear power plants was investigated in air. In the study, number of cycles, slip amplitude and normal load were selected as the main factors of fretting wear. The results indicated that wear increased with load, slip amplitude and number of cycles but was affected mainly by the slip amplitude. SEM micrographs revealed the characteristics of fretting wear features on the surface of the specimens such as stick, partial slip and gross slip which depended on the slip amplitude. It was found that fretting wear was caused by the crack generation along the stick-slip boundaries due to the accumulation of plastic flow at small slip amplitudes and by abrasive wear in the entire contact area at high slip amplitudes.

  • PDF

Vibration Simulation Using LuGre Friction Model for Cladding Tube Fretting Wear Analysis (피복관 프레팅마모 해석을 위한 LuGre 마찰모델 성능 고찰)

  • Park, Nam-Gyu;Kim, Jin-Seon;Kim, Joong-Jin;Kim, Jae-Ik
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.26 no.1
    • /
    • pp.55-62
    • /
    • 2016
  • Nuclear fuels are always exposed to hot temperature and high speed coolant flow during the reactor operation. Thus the fuel rod accompanies small amplitude vibration due to the turbulent flow. The random vibration causes friction between the fuel rod and the grid structure which provides the lateral supports. The friction is critical to the fuel rod fretting wear, and it degrades fuel performance when a severe wear is developed. LuGre friction model is introduced in the paper, and the performance was evaluated comparing to the classical Coulomb model. It is shown that the developed friction force considering the Coulomb friction is not enough to stop or delay the motion while the stick-slip can be simulated using LuGre friction model. Numerical solutions of the two dimensional spacer grid cell model with the modern friction are also reviewed, and it is discussed that the new friction model simulates well the nonlinear mechanism.

Optimization of a Nuclear Fuel Spacer Grid Spring Using Homology (호몰로지 설계를 이용한 원자로 핵연료봉 지지격자 스프링의 최적설계)

  • Lee Jae-Jun;Song Ki-Nam;Park Gyung-Jin
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2006.04a
    • /
    • pp.828-835
    • /
    • 2006
  • Spacer grid springs support the fuel rods in a nuclear fuel system. The spacer grid is a part of a fuel assembly. Since a spring has repeated contacts with the fuel rod, fretting wear occurs on the surface of the spring. Design is usually performed to reduce the wear. The conceptual design process for the spring is defined by using the Independence of axiomatic design and the design is carried out based on the direction that the design matrix indicates. For detailed design an optimization problem is formulated. In optimization, homologous design is employed to reduce fretting wear. The deformation of a structure is called homologous if a given geometrical relationship holds for a given number of structural points before, during, and after the deformation. In this case, the deformed shape of the spring should be the same as that of the fuel rod. 1bis condition is transformed to a function and considered as a constraint in the optimization process. The objective function is minimizing the maximum stress to allow a local plastic deformation. Optimization results show that the contact occurs in a wide range. Also, the results are verified by nonlinear finite element analysis.

  • PDF

Structural Design Considerations on the Spacer Grid Assembly of PWR Nuclear Fuel (경수로 핵연료 지지격자체 구조설계에 대한 소고)

  • Song, Kee-nam
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.7 no.3
    • /
    • pp.54-60
    • /
    • 2011
  • A spacer grid, which supports nuclear fuel rods laterally and vertically with a friction grip, is one of the most important structural components in a PWR fuel. The form of grid strap and supporting parts such as grid spring and dimple is known to be closely related with the mechanical/structural performance of spacer grid and nuclear fuel assembly. In this study, reviewing various research results for enhancing the performance of the spacer grid, some structural design considerations and research directions on the spacer grid assembly are suggested for further study.

Influence of Temperature on the Fretting Wear of Advanced Nuclear Fuel Cladding Tube against Supporting Grid (온도 상승이 개량형 핵연료 피복관과 지지격자 사이의 프레팅 마멸에 미치는 영향)

  • Lee Young-Ze;Park Yong-Chang;Jeong Sung-Hoon;Kim Jin-Seon;Kim Yong-Hwan
    • Tribology and Lubricants
    • /
    • v.22 no.3
    • /
    • pp.144-148
    • /
    • 2006
  • The experimental investigation was performed to find the associated changes in characteristics of fretting wear with various water temperatures. The fretting wear tests were carried out using the zirconium alloy tubes and the grids with increasing the water temperature. The tube materials in water of $20^{\circ}C,\;50^{\circ}C\;and\;80^{\circ}C$ were tested with the applied load of 20 N and the relative amplitude of $200{\mu}m$. The worn surfaces were observed by SEM, EDX analysis and 2D surface profiler. As the water temperature increased, the wear volume was decreased, but oxide layer was increased on the worn surface. The abrasive wear mechanism was observed at water temperature of $20^{\circ}C$ and adhesive wear mechanism occurred at water temperature of $50^{\circ}C,\;80^{\circ}C$. As the water temperature increased, surface micro-hardness was decreased, but wear depth and wear width were decreased due to increasing stick phenomenon. Stick regime occurred due to the formation of oxide layer on the worn surface with increasing water temperatures

Improved Coating Process for Enhanced Wear Resistance of CrAl Coated Claddings for Accident Tolerant Fuel (공정 개선에 따른 사고저항성 CrAl 코팅 피복관의 내마모성 향상)

  • Kim, Sung Eun;Lee, Young-Ho;Kim, Dae Ho;Kim, Hyun-Gil
    • Tribology and Lubricants
    • /
    • v.38 no.4
    • /
    • pp.136-142
    • /
    • 2022
  • This paper investigates the enhanced wear performance of a CrAl coated accident tolerant fuel (ATF) cladding. In the wake of the Fukushima accident, extensive research on ATF with respect to improving the oxidation resistance of cladding materials is ongoing. Since coated Zr claddings can be applied without major changes to the criteria for reactor core design, many researchers are studying coatings for claddings. To improve the quality of the CrAl coating layer, optimization of the manufacturing process is imperative. This study employs arc ion plating to obtain improved CrAl coated claddings using CrAl binary alloy targets through an improved coating method. Surface roughness and adhesion are improved, and droplets are reduced. Furthermore, the coated layer has a dense and fine microstructure. In scratch tests, all the tested CrAl coated claddings exhibit a superior resistance compared to the Zr cladding. In a fretting wear test, the wear volume of the CrAl coated claddings is smaller compared to the Zr cladding. Furthermore, the coated cladding manufactured through the improved process exhibits better wear resistance than other CrAl coated claddings. Based on these results, we suggest that fine microstructure is attributed to a mechanically and microstructurally robust CrAl coating layer, which enhances wear resistance.

Modal Analysis and Testing for a Middle Spacer Grid of a Nuclear Fuel Rod (핵 연료봉 중간 지지격자의 모달 해석 및 실험)

  • Ryu, Bong-Jo;Koo, Kyung-Wan
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.12
    • /
    • pp.1948-1952
    • /
    • 2012
  • The paper presents modal testing and analysis in order to obtain the dynamic characteristics of a middle spacer grids of a nuclear fuel rod. A spacer grid is one of the important structural elements supporting nuclear fuel rods. Such a fuel rod can be oscillated by its thermal expansion, neutron irradiation and etc. due to cooling water flow under the operation of a nuclear power plant. When the fuel rod vibrates, fretting wear due to repeated friction motion between the fuel rods and spacer grids can be occurred, and so the fuel rod is damaged. In this paper, through modal analysis and testing, natural frequencies and modes of a middle spacer grid were calculated, and the following conclusions were obtained. Firstly the numerical first-seven natural frequencies for spacer grids of a fuel rod having complicated structures have a small difference within 3.8% with experimental natural frequencies, and so the suitability of simulation results was verified. Secondly, experimental mode shapes for a middle spacer grid of a nuclear fuel rod were verified by obtaining lower non-diagonal terms through MAC(Modal Assurance Criteria), and were confirmed by the simulation modes.