• Title/Summary/Keyword: nuclear facilities

Search Result 717, Processing Time 0.031 seconds

Shaking Table Test to Verify the Seismic Performance of Nuclear Electric Components (원자력 전기기기 부품의 내진성능 확인을 위한 진동대 실험)

  • Chang, Sung Jin;Jeon, Bub Gyu;Park, Dong Uk;Kim, Sung Wan
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.28 no.3
    • /
    • pp.141-147
    • /
    • 2024
  • Earthquakes of magnitude 3.0 or greater occur in Korea about 10 times on average yearly, and the number of earthquakes occurring in Korea is increasing. As many earthquakes have recently occurred, interest in the safety of nuclear power plants has increased. Nuclear power plants are equipped with many cabinet-type control facilities to regulate safety facilities, and function maintenance is required during an earthquake. The seismic performance of the cabinet is divided into structural and functional performances. Structural performance can be secured during the design procedure. Functional performance depends on the vibration performance of the component. Therefore, it is necessary to confirm the seismic performance of the components. Generally, seismic performance is confirmed through seismic simulation tests. When checking seismic performance through seismic simulation tests, it is difficult to determine the effect of frequency and maximum acceleration on an element. In this paper, shaking table tests were performed using various frequencies and various maximum accelerations. The seismic performance characteristics of the functions of electrical equipment components were confirmed through tests.

A Framework of Decommissioning Cost Estimation for Nuclear Research Facilities (원자력연구시설 해체비용 산정 구조)

  • Jeong Kwan-Seong;Lee Dong-Gyu;Lee Kune-Woo;Oh Won-Zin;Jung Chong-Hun;Park Jin-Ho
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.4 no.2
    • /
    • pp.171-178
    • /
    • 2006
  • Decommissioning cost estimation is a very important technique in designing and planning of nuclear facilities' decommissioning. Decommissioning cost estimation should be made according to the phases of decommissioning activities and installed components of nuclear facilities. In this paper, the basic framework necessary for decommissioning cost estimation is completed so that it could be used as a technique for decommissioning costs estimation by specifying cost items and group components and unit cost factors on which work time is calculated. Also, factors to be considered for decommissioning cost estimation of major activities and tasks are reviewed. Afterwards, these techniques will be utilized as a basic technology to establish methodology of decommissioning cost estimation and evaluation.

  • PDF

Characteristics of Operator to Malfunctions of Multi-jointed Manipulator Arm during Maintenance and Decommissioning of Nuclear Facilities (원자력시설 유지보수 및 해체 작업시 다관절 매니퓰레이터 이상동작에 대한 작업자의 특성)

  • Jeong, Kwan-Seong;Moon, Jei-Kwon;Lee, Kune-Woo;Hyun, Dong-Jun;Choi, Byung-Seon
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.10 no.2
    • /
    • pp.87-96
    • /
    • 2012
  • With a view to determine a safe speed the limit of a manipulator arm, several experiments was performed with a multi-jointed manipulator in maintenance and decommissioning tasks of nuclear facilities. Under the simulated emergency conditions, which were generated with random combinations of manipulator arm speed, failure probability and failure type, response characteristics of human operators to various malfunctions of a manipulator arm were measured in terms of reaction time, number of false alarm, and number of misses. This paper demonstrated that failure type, manipulator axes and manipulator arm speed has significant effects on human reaction time. As a whole the reaction time was slightly increased with manipulator arm speed, which is showed somewhat different pattern due to failure type. The reaction time to an axis acting on a workpiece directly, which could flex and extend, was fastest and much more its standard deviation was small. Various factors which may affect safe speed were also described.

The structural and non-linear dynamic analysis for radioactive waste container

  • Yu-Yu Shen;Kuei-Jen Cheng;Hsoung-Wei Chou
    • Nuclear Engineering and Technology
    • /
    • v.55 no.8
    • /
    • pp.3010-3016
    • /
    • 2023
  • In recent years, the development of radioactive waste containers for nuclear facility decommissioning and dismantling is a critical issue because the Taiwan domestic boiling water reactor nuclear power plant is going to be decommissioned. The main purpose of this research is to design a metal container that meets the structural requirements of related regulations. At first, the shielding analysis was performed by varying dimensions of radioactive waste to determine the storage efficiency of the container. Then, a series of structural analyses for operational and accidental conditions of the container with full load were conducted, such as lifting, stacking, and drop impact conditions. On the other hand, the field drop impact tests were carried out to ensure structural integrity. The present research demonstrates the structural safety of the developed container for decommissioned nuclear facilities in Taiwan.