• Title/Summary/Keyword: novel materials

Search Result 1,904, Processing Time 0.03 seconds

A novel brief questionnaire using a face rating scale to assess dental anxiety and fear

  • Takuya Mino;Aya Kimura-Ono;Hikaru Arakawa;Kana Tokumoto;Yoko Kurosaki;Yoshizo Matsuka;Kenji Maekawa;Takuo Kuboki
    • The Journal of Advanced Prosthodontics
    • /
    • v.16 no.4
    • /
    • pp.244-254
    • /
    • 2024
  • PURPOSE. This study aimed to evaluate the reliability and validity of a four-item questionnaire using a face rating scale to measure dental trait anxiety (DTA), dental trait fear (DTF), dental state anxiety (DSA), and dental state fear (DSF). MATERIALS AND METHODS. Participants were consecutively selected from patients undergoing scaling (S-group; n = 47) and implant placement (I-group; n = 25). The S-group completed the questionnaire both before initial and second scaling, whereas the I-group responded on the pre-surgery day (Pre-day), the day of implant placement (Imp-day), and the day of suture removal (Post-day). RESULTS. The reliability in the S-group was evaluated using the test-retest method, showing a weighted kappa value of DTA, 0.61; DTF, 0.46; DSA, 0.67; DSF, 0.52. Criterion-related validity, assessed using the State-Trait Anxiety Inventory's trait anxiety and state anxiety, revealed positive correlations between trait anxiety and DTA/DTF (DTA, ρ = 0.30; DTF, ρ = 0.27, ρ: correlation coefficient) and between state anxiety and all four items (DTA, ρ = 0.41; DTF, ρ = 0.32; DSA, ρ = 0.25; DSF, ρ = 0.25). Known-group validity was assessed using the initial data and Imp-day data from the S-group and I-group, respectively, revealing significantly higher DSA and DSF scores in the I-group than in the S-group. Responsiveness was gauged using I-group data, showing significantly lower DSA and DSF scores on post-day compared to other days. CONCLUSION. The newly developed questionnaire has acceptable reliability and validity for clinical use, suggesting its usefulness for research on dental anxiety and fear and for providing patient-specific dental care.

Efficient Red-Color Emission of InGaN/GaN Double Hetero-Structure Formed on Nano-Pyramid Structure

  • Go, Yeong-Ho;Kim, Je-Hyeong;Gong, Su-Hyeon;Kim, Ju-Seong;Kim, Taek;Jo, Yong-Hun
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.08a
    • /
    • pp.174-175
    • /
    • 2012
  • (In, Ga) N-based III-nitride semiconductor materials have been viewed as the most promising materials for the applications of blue and green light emitting devices such as light-emitting diodes (LEDs) and laser diodes. Although the InGaN alloy can have wide range of visible wavelength by changing the In composition, it is very hard to grow high quality epilayers of In-rich InGaN because of the thermal instability as well as the large lattice and thermal mismatches. In order to avoid phase separation of InGaN, various kinds of structures of InGaN have been studied. If high-quality In-rich InGaN/GaN multiple quantum well (MQW) structures are available, it is expected to achieve highly efficient phosphor-free white LEDs. In this study, we proposed a novel InGaN double hetero-structure grown on GaN nano-pyramids to generate broad-band red-color emission with high quantum efficiency. In this work, we systematically studied the optical properties of the InGaN pyramid structures. The nano-sized hexagonal pyramid structures were grown on the n-type GaN template by metalorganic chemical vapor deposition. SiNx mask was formed on the n-type GaN template with uniformly patterned circle pattern by laser holography. GaN pyramid structures were selectively grown on the opening area of mask by lateral over-growth followed by growth of InGaN/GaN double hetero-structure. The bird's eye-view scanning electron microscope (SEM) image shows that uniform hexagonal pyramid structures are well arranged. We showed that the pyramid structures have high crystal quality and the thickness of InGaN is varied along the height of pyramids via transmission electron microscope. Because the InGaN/GaN double hetero-structure was grown on the nano-pyramid GaN and on the planar GaN, simultaneously, we investigated the comparative study of the optical properties. Photoluminescence (PL) spectra of nano-pyramid sample and planar sample measured at 10 K. Although the growth condition were exactly the same for two samples, the nano-pyramid sample have much lower energy emission centered at 615 nm, compared to 438 nm for planar sample. Moreover, nano-pyramid sample shows broad-band spectrum, which is originate from structural properties of nano-pyramid structure. To study thermal activation energy and potential fluctuation, we measured PL with changing temperature from 10 K to 300 K. We also measured PL with changing the excitation power from 48 ${\mu}W$ to 48 mW. We can discriminate the origin of the broad-band spectra from the defect-related yellow luminescence of GaN by carrying out PL excitation experiments. The nano-pyramid structure provided highly efficient broad-band red-color emission for the future applications of phosphor-free white LEDs.

  • PDF

소설과 말기 암환자를 통해 본 한국인의 죽음의 의미

  • Jeon, Hye-Won;Kim, Bun-Han
    • Korean Journal of Hospice Care
    • /
    • v.3 no.2
    • /
    • pp.34-54
    • /
    • 2003
  • Every one experiences death one day, however no one can knows exactly what it is because people can not experience death until it comes, it is therefore impossible to judge correctly on the phenomenon of the death. On the whole, man experiences indirect death through the mass communications such as TV drama, fiction, magazine etc because those methods can easily access by every one. In addition to this, people usually acquire the negative awareness of death through the dramatic change of story like dying of cancer for dramatic effect by giving scare and fear to the cancers. The purpose of this study is to provide basic information on the spiritual care that enables the facing death patients to accept death as a part of life and divert hope from scare about after death by comparing and analyzing of two aspects of death meaning I.e, Korean fiction and the end stage cancer patients. Additionally, for medical staff to understand the facing death cancer patients by making to aware patients correctly and provide the better quality of care. The study was performed from September 28, 2002 to February, 28 2003. The materials of this study were collected by direct data obtained from observation, interviews, note and diary of end stage of cancer patients and written materials acquired from Korean contemporary fiction. Participants of this study were 4 end stage cancer patients including 2 lung cancer patients, 1 liver cancer patient and 1 esophagus cancer patient. The methodology used in this study was divided into two types; Huberman & Miles methodology was used for fiction to find and categorize subject, and Colaizzi, one of phenomenological methodology was used for end stage cancer patients to find the major meaning, subject and categorization. 1.The death investigated in the fiction, was found as a progress of negative emotion, acceptance and sublimation, life related subjects in the negative emotion were tenacity for life, anxiety, lingering attachment, responsibility, abandonment and death related subjects were shock, isolation, fear, scare and rejection. Acceptance related subjects were acceptance, destiny, secularism, preparation and arrangement, and sublimation related subjects were sublimation through Christian and Buddhism. 2.The death showed in the participants was negative emotion, acceptance and sublimation, life related subjects were repentance, anxiety, responsibility and hopelessness, and death related subjects were dejection, solitude, anger, fear and scare. The acceptance was a type of religious acceptance that admitted instantly by reaching an understanding with the God, and death was accepted as a progress of preparation, arrangement, acceptance and hope. Sublimation related subjects were Christian sublimation and relief or destiny incurred from self-reflective sublimation through communications and thoughts. 3.The death in view of fiction and participants were positively accepted both death and negative emotion, and the study disclosed the fact that death was sublimated dependent on religion. 4.The progress of negative emotion, acceptance and sublimation was disclosed more complicated and various in the real end stage cancer patients and acceptance only found in the patients on the form of religious acceptance, according to the results compared with fiction and real end stage cancer patients. The death showed in the fiction was standardized, gradated and similar progress with psychological status of Kubler-Ross. However, death in the participants was showed complex and various feelings simultaneously, and sometimes they accepted death positively. The sublimation through religion was found in Buddhism and Christian in the fiction and mostly Christian in the participants due to a number of Hospice patients. It was found that negative emotion various types of death was more found in the participants than fiction. It is therefore necessary to study on the response of death in various types. In the participants death was incurred more systematic and variously, we knew that nursing practice focused on experience of participants is required and reality on death is much profound than we analyzed and presented, lots of situations and reactions should be premised because we can not completely rule out the negligence possibility of care mediation of participants. In caring for the facing death patients, we discovered and confirmed again through this study that the spiritual care should be needed as a mediation method.

  • PDF

Synthesis and Screening of the System $SrO-Gd_2O_3-Al_2O_3$Doped with Tb by Polymerized-Complex Combinatorial Chemistry (고분자 착체 조합 화학법을 이용한 Tb이 첨가된 $SrO-Gd_2O_3-Al_2O_3$계 형광물질의 합성 및 탐색)

  • Jeong, Yang Sun;Kim, Chang Hae;Park, Hee Dong;Park, Joon Taik;Kang, Sung Kwon
    • Journal of the Korean Chemical Society
    • /
    • v.45 no.5
    • /
    • pp.461-469
    • /
    • 2001
  • The combinatorial approach has been applied to discover and optimize the composition of the novel or enhanced materials. In this study, we screened the optimum composition of the system SrO-Gd$_2$O$_3$-Al$_2$O$_3$ doped with $Tb^{3+}$ by a polymerized-complex combinatorial chemistry method. Mixtures with compositions of Sr, Gd and Al component that is in the range from 0 to 1 in about 0.05 increments could be tested. The sample powders were synthesized by a polymerized complex method. To prepare appropriately polymeric precursors, we used the metallic nitrates, citric acid and ethylene glycol. The luminescence properties of the synthesized powders are investigated using the UV and VUV (Vacuum-UV: 147 nm) photoluminescence spectrometer. In addition, the crystallinity and morphology of powder were monitored by X-ray diffraction spectrometer and scanning electron microscopy. In result of VUV PL works, there are good luminescent samples with the composition of 0.595 < x < 0.733 and 0.016 < y < 0.017 in Gd1-x-yAlxTbyO$\delta$ and 0.049 < x < 0.064 and 0.02 < y < 0.039 in $Sr_xAl_{1-x-y}Tb_yO_$\delta$$, their materials can be applicable to plasma display panels as the green phosphor.

  • PDF

A Novel in Vitro Method for the Metabolism Studies of Radiotracers Using Mouse Liver S9 Fraction (생쥐 간 S9 분획을 이용한 방사성추적자 대사물질의 새로운 체외 측정방법)

  • Ryu, Eun-Kyoung;Choe, Yearn-Seong;Kim, Dong-Hyun;Lee, Sang-Yoon;Choi, Yong;Lee, Kyung-Han;Kim, Byung-Tae
    • The Korean Journal of Nuclear Medicine
    • /
    • v.38 no.4
    • /
    • pp.325-329
    • /
    • 2004
  • Purpose: Usefulness of mouse liver S9 fraction was evaluated for the measurement of the metabolites in the in vitro metabolism study of $^{18}F$-labeled radiotracers. Materials and Methods: Mouse liver S9 fraction was isolated at au early step in the course of microsome preparation. The in vitro metabolism studies were tarried out by incubating a mixture containing the radiotracer, S9 fraction and NADPH at $37^{\ciirc}C$, and an aliquot of the mixture was analyzed at the indicated time points by radio-TLC. Metabolic defluorination was further confirmed by the incubation with calcium phosphate, a bone mimic. Results: The radiotracer $[^{18}F]1$ underwent metabolic defluorination within 15 min, which was consistent with the results of the in vivo method and the in vitro method using microsome. Radiotracer $[^{18}F]2$ was metabolized to three metabolites including $4-[^{18}F]fluorobenzoic$ acid within 60 min. It is likely that the one of these metabolites at the origin of radio-TLC was identical with the one that obtained from the in vivo and in vitro (microsome) method. Compared with the in vitro method using microsome, the method using S9 fraction gave a similar pattern of the metabolites but with a different ratio, which can be explained by the presence of cytosol in the S9 fraction. Conclusion: These results suggest that the findings of the in vitro metabolism studies using S9 fraction can reflect the in vivo metabolism of novel radiotracers in the liver. Moreover, this method can be used as a tool to determine metabolic defluorination along with calcium phosphate absorption method.

Highly Doped Nano-crystal Embedded Polymorphous Silicon Thin Film Deposited by Using Neutral Beam Assisted CVD at Room Temperature

  • Jang, Jin-Nyeong;Lee, Dong-Hyeok;So, Hyeon-Uk;Hong, Mun-Pyo
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.08a
    • /
    • pp.154-155
    • /
    • 2012
  • The promise of nano-crystalites (nc) as a technological material, for applications including display backplane, and solar cells, may ultimately depend on tailoring their behavior through doping and crystallinity. Impurities can strongly modify electronic and optical properties of bulk and nc semiconductors. Highly doped dopant also effect structural properties (both grain size, crystal fraction) of nc-Si thin film. As discussed in several literatures, P atoms or radicals have the tendency to reside on the surface of nc. The P-radical segregation on the nano-grain surfaces that called self-purification may reduce the possibility of new nucleation because of the five-coordination of P. In addition, the P doping levels of ${\sim}2{\times}10^{21}\;at/cm^3$ is the solubility limitation of P in Si; the solubility of nc thin film should be smaller. Therefore, the non-activated P tends to segregate on the grain boundaries and the surface of nc. These mechanisms could prevent new nucleation on the existing grain surface. Therefore, most researches shown that highly doped nc-thin film by using conventional PECVD deposition system tended to have low crystallinity, where the formation energy of nucleation should be higher than the nc surface in the intrinsic materials. If the deposition technology that can make highly doped and simultaneously highly crystallized nc at low temperature, it can lead processes of next generation flexible devices. Recently, we are developing a novel CVD technology with a neutral particle beam (NPB) source, named as neutral beam assisted CVD (NBaCVD), which controls the energy of incident neutral particles in the range of 1~300eV in order to enhance the atomic activation and crystalline of thin films at low temperatures. During the formation of the nc-/pm-Si thin films by the NBaCVD with various process conditions, NPB energy directly controlled by the reflector bias and effectively increased crystal fraction (~80%) by uniformly distributed nc grains with 3~10 nm size. In the case of phosphorous doped Si thin films, the doping efficiency also increased as increasing the reflector bias (i.e. increasing NPB energy). At 330V of reflector bias, activation energy of the doped nc-Si thin film reduced as low as 0.001 eV. This means dopants are fully occupied as substitutional site, even though the Si thin film has nano-sized grain structure. And activated dopant concentration is recorded as high as up to 1020 #/$cm^3$ at very low process temperature (< $80^{\circ}C$) process without any post annealing. Theoretical solubility for the higher dopant concentration in Si thin film for order of 1020 #/$cm^3$ can be done only high temperature process or post annealing over $650^{\circ}C$. In general, as decreasing the grain size, the dopant binding energy increases as ratio of 1 of diameter of grain and the dopant hardly be activated. The highly doped nc-Si thin film by low-temperature NBaCVD process had smaller average grain size under 10 nm (measured by GIWAXS, GISAXS and TEM analysis), but achieved very higher activation of phosphorous dopant; NB energy sufficiently transports its energy to doping and crystallization even though without supplying additional thermal energy. TEM image shows that incubation layer does not formed between nc-Si film and SiO2 under later and highly crystallized nc-Si film is constructed with uniformly distributed nano-grains in polymorphous tissues. The nucleation should be start at the first layer on the SiO2 later, but it hardly growth to be cone-shaped micro-size grains. The nc-grain evenly embedded pm-Si thin film can be formatted by competition of the nucleation and the crystal growing, which depend on the NPB energies. In the evaluation of the light soaking degradation of photoconductivity, while conventional intrinsic and n-type doped a-Si thin films appeared typical degradation of photoconductivity, all of the nc-Si thin films processed by the NBaCVD show only a few % of degradation of it. From FTIR and RAMAN spectra, the energetic hydrogen NB atoms passivate nano-grain boundaries during the NBaCVD process because of the high diffusivity and chemical potential of hydrogen atoms.

  • PDF

Patient Setup Aid with Wireless CCTV System in Radiation Therapy (무선 CCTV 시스템을 이용한 환자 고정 보조기술의 개발)

  • Park, Yang-Kyun;Ha, Sung-Whan;Ye, Sung-Joon;Cho, Woong;Park, Jong-Min;Park, Suk-Won;Huh, Soon-Nyung
    • Radiation Oncology Journal
    • /
    • v.24 no.4
    • /
    • pp.300-308
    • /
    • 2006
  • $\underline{Purpose}$: To develop a wireless CCTV system in semi-beam's eye view (BEV) to monitor daily patient setup in radiation therapy. $\underline{Materials\;and\;Methods}$: In order to get patient images in semi-BEV, CCTV cameras are installed in a custom-made acrylic applicator below the treatment head of a linear accelerator. The images from the cameras are transmitted via radio frequency signal (${\sim}2.4\;GHz$ and 10 mW RF output). An expected problem with this system is radio frequency interference, which is solved utilizing RF shielding with Cu foils and median filtering software. The images are analyzed by our custom-made software. In the software, three anatomical landmarks in the patient surface are indicated by a user, then automatically the 3 dimensional structures are obtained and registered by utilizing a localization procedure consisting mainly of stereo matching algorithm and Gauss-Newton optimization. This algorithm is applied to phantom images to investigate the setup accuracy. Respiratory gating system is also researched with real-time image processing. A line-laser marker projected on a patient's surface is extracted by binary image processing and the breath pattern is calculated and displayed in real-time. $\underline{Results}$: More than 80% of the camera noises from the linear accelerator are eliminated by wrapping the camera with copper foils. The accuracy of the localization procedure is found to be on the order of $1.5{\pm}0.7\;mm$ with a point phantom and sub-millimeters and degrees with a custom-made head/neck phantom. With line-laser marker, real-time respiratory monitoring is possible in the delay time of ${\sim}0.17\;sec$. $\underline{Conclusion}$: The wireless CCTV camera system is the novel tool which can monitor daily patient setups. The feasibility of respiratory gating system with the wireless CCTV is hopeful.

Development of Calcification-Resistant Bovine Pericardium with $PEO-SO_3$ (I) - An implantation study of bovine pericardium at aorta and pulmonary artery in canine model - ($PEO-SO_3$를 이용한 항석회화 조직첨포의 개발 (I) - 잡견을 이용한 대동맥과 폐동맥 이식 실험연구 -)

  • Kim, Hyoung-Mook;Baek, Man-Jong;Sun, Kyung;Kim, Kwang-Taik;Lee, In-Sung;Kim, Hark-Jei;Lee, Won-Kyu;Park, Ki-Dong
    • Journal of Chest Surgery
    • /
    • v.31 no.10
    • /
    • pp.919-923
    • /
    • 1998
  • Background: Calcific degeneration is unavoidable in either homo- or heterografts implanted in the human body. We have developed a calcification-resistant cardiovascular tissue patch using a novel technique of anticalcification. Materials and methods: Fresh bovine pericardium was harvested at the slaughter house and transfered to the laboratory in Hank's solution. After trimming and fixing the pericardium, it was embedded in 4$^{\circ}C$ 0.65% glutaraldehyde for a week and then washed by phosphate-buffered saline(PBS) of pH 7.4. This prepared pericardium was then stored in 2.5% sulphonated polyethyleneoxide(PEO-SO3) solution for 2 days at room temperature and reversed by 4$^{\circ}C$ NaBH4 solution for 16 hours. To evaluate the calcification-resistance of surface modified bovine pericardium with PEO-SO3, either glutaraldehyde- treated(GA group, n=4) or PEO-SO3-treated pericardial patch(PEO-SO3 group, n=4) was implanted into adult mongrel dog to reconstruct the main pulmonary artery and the descending aorta using a partial clamp technique. After 1 month follow-up, the implanted patches were retrieved to evaluate the pathologic findings and the content of calcium and phosphorous. Results: The PEO-SO3 group showed substantially less retraction and significantly less calcium deposition than the GA group in both aortic(7.10$\pm$1.05 vs. 13.81$\pm$2.33 mg/g of dried tissue) and pulmonary positions(1.55$\pm$0.29 vs. 6.72$\pm$0.70 mg/g)(p<0.01). Phosphorous contents were also less in the PEO-SO3 group than the GA group significantly, 8.11$\pm$1.07 mg/g vs. 19.33$\pm$4.31 mg/g in the aortic and 2.58$\pm$0.40 vs. 12.60$\pm$3.40 mg/g in thepulmonary position(p<0.01). Conclusions: These findings suggest that PEO-SO3 modified bovine pericardium is highly calcification-resistant but further study is needed to evaluate the long-term biological safety and compatibility of the prosthesis.

  • PDF

Effects of 166Holmium and 166Holmium-chitosan Complex(166Ho-CHICO) on Normal Brain of Rats (홀뮴 및 홀뮴-키토산 복합체가 정상 백서 뇌에 미치는 효과에 대한 연구)

  • Sun, Jing He;Joh, Chul W;Ahn, Young Hwan;Park, Chan Hee;Shim, Chull;Park, Kyung Bae;Cho, Kyung Gi
    • Journal of Korean Neurosurgical Society
    • /
    • v.29 no.10
    • /
    • pp.1309-1315
    • /
    • 2000
  • Objectives : We performed an in vivo experiment to investigate the effect of $^{166}Holmium$ and $^{166}Holmium$-chitosan complex($^{166}Ho$-CHICO) on the normal brain of rats and to determine the sublethal dose of $^{166}Ho$-CHICO. Materials and Methods : $^{166}Ho$ is a beta and gamma ray emitter. $^{166}Ho$-CHICO is a novel radio-pharmaceutical complex with chitosan to facilitate the transport of $^{166}Ho$ obtained from Korea Atomic Energy Research Center(Taejon, Korea). It is in acidic form and becomes gel state at alkaline pH. One hundred and seventy consecutive rats were divided into four groups : $^{166}Ho$ treated(n=50), $^{166}Ho$-CHICO treated(n=57), saline treated(n=5) and chitosan treated(n=5) groups. $^{166}Ho$ and $^{166}Ho$-CHICO were injected into the rat brain stereotactically with various doses of 0.1mCi/$20{\mu}l$, 0.2mCi/$20{\mu}l$, 0.3mCi/$20{\mu}l$, and 0.4mCi/$20{\mu}l$ using an automated microinjector. Nuclear imaging, histopathological and hematological studies were performed in 10 rats in each group at 1 day, 3days, 7 days, 1 month and 3 months after the injections. Results : An infiltration of inflammatory cells and necrotic changes were noted in $^{166}Ho$ treated group at 1 week after the injection. A wedge-shaped tissue defect due to necrosis, lined with infiltrated glial cells in $^{166}Ho$ treated group and a cystic defect lined with reactive astroglial cells in $^{166}Holmium$-CHICO treated group at 3 months after the injection were observed. $^{166}Ho$ alone without chitosan leaked out and caused necrotic lesion on the cerebral surface but $^{166}Holmium$-CHICO treated group did not show this feature. As the dose of $^{166}Ho$ increased, the mortality rates were also increased. The mortality rate of the $^{166}Holmium$-CHICO group was higher than the $^{166}Ho$ treated group at a dose of 0.4mCi/$20{\mu}l$/300g. There was no detectable radioactivity due to the leakage or extravasation from the injected site of the brain on the scintigraphy performed at 1 hour, 24 hours and 48 hours after the injection. There was also no detectable activity of $^{166}Holmium$-CHICO in other organs including spleen, liver and kidney. Conclusions : $^{166}Ho$-CHICO did not leak out to the critical cortical surface of the brain from the injection site and induced radiation changes of the parenchyma around the injection site without cortical damage. The sublethal dose of $^{166}Ho$-CHICO for the normal brain in rats was determined to be 0.2mCi/$20{\mu}l$/300g.

  • PDF

Accuracy and Clinical Outcomes of Ultrasound-guided Glenohumeral joint Injection: Acromioclavicular Approach in Patients with Adhesive Capsulitis (초음파를 이용한 견관절 관절강내 주사의 정확성과 임상적 결과: 유착성 관절낭염 환자의 견봉 쇄골 접근법)

  • Lhee, Sang-Hoon;Hwang, Seok-Min
    • The Journal of Korean Orthopaedic Ultrasound Society
    • /
    • v.5 no.1
    • /
    • pp.9-14
    • /
    • 2012
  • Purpose: The purpose of the study was to evaluate the accuracy and clinical outcome of ultrasound-guided glenohumeral joint steroid injection on adhesive capsulitis. Materials and Methods: Patients who were diagnosed as adhesive capsulitis by MRI and physical examination and did not improve their symptom with physical therapy and NSAIDS treatment more than 6 months were included in the study. Patients who showed any other shoulder pathology or history if trauma were excluded from the study. 33 patients including 15 males and 18 females were enrolled in the study, the average age being 55.1 (age 42~72). Cocktail of steroid, lidocaine, saline and contrast medium injected inside shoulder glenohumeral joint using novel approach (which we called acromioclavicular approach) under ultrasound guidance. Clinical outcome was measured through passive range of motion and VAS scoring system. Results: Based on radiographic findings, cases were classified according to the leakage of contrast medium; perfect confinement of contrast-medium inside the capsule, partial leakage of the medium and contrast-medium found at outside the joint. Total 25 cases (76%) out of 33 cases showed perfect confinement of contrast-medium inside the glenohumeral joint. Partial leakage was observed in 6 cases (18%), and contrast medium was observed outside of the glenohumeral joint in 2 cases (6%). Perfect-confinement group showed $111^{\circ}$($80{\sim}140^{\circ}$) of forward flexion and $48^{\circ}$($0{\sim}90^{\circ}$) of external rotation before injection, and improved to $134^{\circ}$($90{\sim}150^{\circ}$) of forward flexion and $70^{\circ}$($30{\sim}90^{\circ}$) of external rotation after injection (p<0.01). Partial leakage showed $120^{\circ}$($90{\sim}150^{\circ}$) of forward flexion and $70^{\circ}$($10{\sim}90^{\circ}$) of external rotation before injection, and improved to $139^{\circ}$($135{\sim}140^{\circ}$) of forward flexion and $78^{\circ}$($50{\sim}90^{\circ}$) of external rotation after injection (p<0.01). VAS score improved from 7.1 (score 3~9) to 2.6 (score 0~5) (p<0.01) in perfect confinement group, from 7.5 (score 7~9) to 3.3 (score 2~4) (p<0.01) in partial leakage group. Two group showed no significant difference. Conclusion: Accuracy of Acromioclavicular approach was 94% which is better than any other methods published so far. Partial leakage of the injection material did not show inferior result compared to perfect injection.

  • PDF