• Title/Summary/Keyword: nonrestraint

Search Result 5, Processing Time 0.016 seconds

A Study on the Mechanical Properties and Residual Stress Distribution of Ti Welding Material (Ti 용접재의 기계적 특성 및 잔류응력의 분포에 관한 연구)

  • 최병기;장경천;국중민;정장만;구남열
    • Journal of the Korean Society of Safety
    • /
    • v.18 no.1
    • /
    • pp.1-7
    • /
    • 2003
  • The objective of this paper was to investigate the welding characteristics according to the restraint condition. the pass number, and the shield gas quantity with titanium commonly using in power stations, aircrafts, ships, and so forth. The residual stress distribution was measured under restraint and nonrestraint welding conditions. The tensile strength and elongation of the 4 pass welded specimen were shown higher about 10% and 30% than those of the 7 pass welded specimen at the same welding conditions respectably. Also, the more shield gas quantity and the shorter natural cooling time, the higher tensile strength and the lower elongation.

Implementation of a Respiration Measurement System Based on a Nonrestraint Approach (무구속 방식의 호흡 측정 시스템 구현)

  • Cho, Seok-Hyang;Cho, Seung-Ho
    • Journal of the Korea Society of Computer and Information
    • /
    • v.19 no.11
    • /
    • pp.33-41
    • /
    • 2014
  • In this paper, we implemented a system to measure respiration rate with nonrestraint sensors comfortable for people to do their everyday life. The proposed system consists of a pad covered with a Piezoelectric sensor, a respiration measuring device able to send the signal data after amplifying and filtering the source signals to the viewer, a viewer providing sensor data visualization and implementing the respiration measuring algorithm. The algorithm is based on a breathing cycle with the local peak points extracted from threshold on sensor data. Respiration measurements on 3 subjects were performed by changing moving averages and thresholds. The proposed system showed less than 5% error rate when proper moving averages are N=50~60 and a range of thresholds is 800~1300. The system will contribute to preventing suffocation during sleep for infants and the elderly living alone.

Comparative Studies on the ECG Using a Floating Electrode and Flexible Electrode (플로팅 전극과 플랙시블 전극의 심전도 비교연구)

  • Shin, Seung-Chul;Lee, Se-Hoon;Kim, Kyung-Ho
    • Proceedings of the Korean Society of Computer Information Conference
    • /
    • 2011.01a
    • /
    • pp.301-302
    • /
    • 2011
  • 본 연구에서는 Floating Electrode와 Flexible Electrode를 사용한 심전도 측정결과의 비교연구를 진행하였다. 일반적으로 심전도 측정시 사용되고 있는 Floating Electrode를 이용하여 심전도 측정을 할 경우 비교적 안정적인 데이터를 얻기 용이하다는 장점이 있지만, 여러 개의 전극을 몸에 붙이는 번거로움과 피실험자의 불쾌감 등 단점도 있다. 반면, 본 연구에서 제안하는 방법은 Flexible Electrode를 침대 혹은 의자와 설치하여 무구속적인 측정 방법을 통하여 사용자의 편이를 향상시키고 불편함을 최소화를 목표로 한다. 신호검출의 가능성은 확인하였으며, 향후 검출된 데이터를 이용하여 일상생활을 하면서 건강상태를 모니터링 할 수 있는 헬스 케어 응용 서비스로의 연구를 진행하고자 한다.

  • PDF

The Characteristic of Temperature in Ventilating Fans by Festraint or Nonrestraint (무 구속·구속 실험에 의한 환풍기 온도 특성)

  • Kim, Sung-Sam
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.30 no.1
    • /
    • pp.44-48
    • /
    • 2016
  • In this paper, we analyzed the operating characteristics of a ventilating fan due to overload and overheating. The experiment assumed the forcible restraint of the blade due to external objects and the aging process. We analyzed the experimental temperature and operating characteristics of the three places in the interior of the ventilating fan. As a result of the analysis, the temperature distribution was highest to lowest in the following order: the thermal fuse, the motor inside, and the above winding. There was smell of burning enamel in the restraint experiment. Following the thermal fuse operation, the insulation of motor winding was good. In the case of rated voltage and new ventilating fan restrained for about 4hours, and the results of restraint experiments in the presence or absence of the thermal fuse, no risk of deformation or fire due to overheating was identified. Henceforward, ignition hazard experiments will be required for additional factors of aging, pollution, and defective insulation.

A Study on the assessment of stress using Wireless ECG (무선 심전도측정을 통한 스트레스 평가에 관한 연구)

  • Lim, Chae-Young;Kim, Kyung-Ho
    • Journal of the Korea Society of Computer and Information
    • /
    • v.16 no.2
    • /
    • pp.17-23
    • /
    • 2011
  • In this paper, daily life stress monitoring system is proposed. The proposed wireless ECG module, reducing the noise and increasing the size of signal, amplification circuit was designed for. Using HRV(Heart Rate Variability), extracted by measuring R-wave, stress diagnostic algorithms to assess the stress of human emotion were developed. For monitoring the activities, the proposed system is consist of small rectangular size for portable and by simple measurement it is possible to measure at any time. Through experiments, the proposed approach to represent user's stress level can be confirmed. Through that, it can see appropriate structure to obtain R-wave for stress assess as well as high resemblance to the clinical electrocardiogram. In this paper, performed experiments was developed nonrestraint measuring and wearable wireless biometric scanner that is able to monitor the heart's electrical activity of everyday life.Using this, the algorithm system, that is able to assess stress index through time-domain and frequency-domain analysis of the front and the rear of performing stress load protocol, was developed,