• Title/Summary/Keyword: nonpoint source pollutant

Search Result 172, Processing Time 0.021 seconds

Performance analysis for reduction facility of nonpoint source pollutant (비점오염원 저감장치의 성능분석)

  • Lee, Jong-Seok;Kim, Chi-Gon
    • Journal of Korea Water Resources Association
    • /
    • v.52 no.3
    • /
    • pp.207-217
    • /
    • 2019
  • This study aims at development and application of a facility that is capable of reducing pollution in water quality by reducing nonpoint source pollutants (NPSP). NPSP originated from the initial rainfall caused not only large catchment of urban area pass a river but also small watershed pass a stream. For this purpose, the performance tests carried out with the field models from the facility based on the preceding study. And the tests induced reduction efficiency of biochemical oxygen demand (BOD), chemical oxygen demand (COD), total nitrogen (T-N) and suspended solid (SS), respectively. The average reduction efficiency obtained by time interval, and the result showed an excellent reduction performance. As a result, the facility satisfied reduction efficiency of NPSP of the proposed standard by the National Institute of Environmental Research, and thus it can be used in practical applications.

Design of Structural BMPs for Low Impact Development (LID) Application and Modelling Its Effect on Reduction of Runoff and Nonpoint Source Pollution: Application of LIDMOD2 (저영향개발(LID)적용을 위한 구조적 BMPs의 유출량 및 비점오염저감 효과모의: LIDMOD2 적용)

  • Kim, Jung Jin;Kim, Tae-Dong;Choi, Donghyuk;Jeon, Ji-Hong
    • Journal of Korean Society on Water Environment
    • /
    • v.27 no.5
    • /
    • pp.580-586
    • /
    • 2011
  • Low impact development (LID) technique is recently proposed as new concept to reduce surface runoff and pollutant loading with various best management practices (BMPs). In this study, LIDMOD2, which is one of the model to evaluate LID, was applied at Mohyeon developing area to evaluate the redcution of annual runoff and pollution loading, cost-reduction efficient by LID with design of structural BMPs including bioretention, wet pond, and wetland. As a simulation results, the bioretention had the highest reduction efficiency for runoff (41.43%), and 22% for T-N and 22% for BOD. Wet pont had the highest reduction efficiency for T-P as showing 25% of reduction rate. As a results of cost-reduction efficient, wet pont represented the highest cost-effective for T-N and BOD with showing 0.43 T-P kg/million won and 17.37 BOD kg/million won, respectively, and bioretention represented the highest cost-effective for T-P with showing 2.52 T-P kg/million won. LID technology could reduce effectively surface runoff and nonpoint source pollution and construct sustainable development. LIDMOD2 could be suggested as useful tool to evaluate and design LID.

Nonpoint Source Pollution Loadings from Land Uses on Small Watersheds (소유역의 토지이용에 따른 비점원오염 부하량)

  • 박승우;류순호;강문성
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.39 no.3
    • /
    • pp.115-127
    • /
    • 1997
  • Nonpoint source (NPS) pollution from small watersheds has recently been brought into attention as a potential pollutant to streams and tnbutaries, as majority of them are experiencing water quality degradation. This necessiates the quantification of NPS loadings from agricultural and forested lands. And this study attempts to quantify daily loadings from forested and farm lands using hydrologic and water quality monitoring. The hydrologic monitoring program consists of five water level gauging stations along creeks and stream at the Banweol reservoir watershed having 1220 hectare in size. Water sam pies were taken and analyzeel periodically at the streamf low gaging sites and tributaries. Soil samples were also taken and the chemical constitutes analyzed. The primary results indicate that the major sources of pollution were small villages and dairy farms on the watersheds, constituting two-third of total nutrient loadings to the reservoir. However, the loadings from paddies and upland areas may cause a problem to the water quality of the reservoir and stream as the measured levels of total nitrogen and phosporus are not low enough to ignore. Further studies are needed to quantify the effects of landuses and treatments at a watershed scale.

  • PDF

Application of BASINS/WinHSPF for Pollutant Loading Estimation in Soyang Dam Watershed (소양강댐 유역의 오염부하량 산정을 위한 BASINS/WinHSPF 적용)

  • Yoon, Chun-Gyeong;Han, Jung-Yoon;Jung, Kwang-Wook;Jang, Jae-Ho
    • Korean Journal of Ecology and Environment
    • /
    • v.40 no.2
    • /
    • pp.201-213
    • /
    • 2007
  • In this study, the Batter Assessment Science Integrating point and Nonpoint Sources (BASINS 3.0)/window interface to Hydrological Simulation Program-FPRTRAN (WinHSPF) was applied for assessment of Soyang Dam watershed. WinHSPF calibration was performed using monitoring data from 2000 to 2004 to simulate stream flow. Water quality (water temperature, DO, BOD, nitrate, total organic nitrogen, total nitrogen, total organic phosphorus and total phosphorus) was calibrated. Calibration results for dry-days and wet-days simulation were reasonably matched with observed data in stream flow, temperature, DO, BOD and nutrient simulation. Some deviation in the model results were caused by the lack of measured watershed data, hydraulic structure data and meteorological data. It was found that most of pollutant loading was contributed by nonpoint source pollution showing about $98.6%{\sim}99.0%$. The WinHSPF BMPRAC was applied to evaluate the water quality improvement. These scenarios included constructed wetland for controlling nonpoint source poilution and wet detention pond. The results illustrated that reasonably reduced pollutant loadin. Overall, BASINS/WinHSPF was found to be applicable and can be a powerful tool in pollutant loading and BMP efficiency estimation from the watershed.

Analysis of First Flush of Recreation Park and Removal Rate According to Rainfall-Runoff Storage Depth (위락시설지역의 초기세척현상과 초기 강우-유출고 저류에 따른 저감효율 분석)

  • Jung, Jae-Woon;Park, Ha-Na;Choi, Dong-Ho;Baek, Sang-Soo;Yoon, Kwang-Sik;Baek, Won-Jin;Beam, Jin-A;Lim, Byung-Jin
    • Journal of Korean Society on Water Environment
    • /
    • v.29 no.5
    • /
    • pp.648-655
    • /
    • 2013
  • Nonpoint source pollution characteristics of recreation park was investigated. Runoff ratio of recreation park ranged 23-57%, which was lower than other urban area since impervious area was less than 37%. The average BOD, COD, TOC, SS, T-N, T-P, were 14.09, 32.86, 12.19, 121.51, 7.78 and 0.72 mg/L, respectively. First flush of recreation park was analyzed by normalized cumulative load - volume curve and mass first flush ratio(MFFn), MFF10 for BOD, COD, SS, T-P, T-N, TOC were 2.90, 1.59, 2.15, 2.74, 2.60, and 1.59, respectively. Observed data showed that 62% of pollutant could be removed by storaging 5 mm rainfall-runoff and even 3 mm depth could store up to 50% of pollutant in runoff.

Estimation of Livestock Pollutant Sources Reduction Effect on Water Quality in Hapcheon Dam Watershed Using HSPF Model (HSPF 모형을 이용한 축산계 비점오염 저감에 따른 합천댐 유역 수질 영향 분석)

  • Cho, Hyun Kyung;Kim, Sang Min
    • Journal of Korean Society on Water Environment
    • /
    • v.36 no.2
    • /
    • pp.98-108
    • /
    • 2020
  • The purpose of this study was to evaluate water quality in Hapcheon dam via using the Hydrological Simulation Program-Fortran (HSPF) model and applied livestock reduction scenarios. Hapcheon dam watershed input data for the HSPF model were established using the stream, land use, digital elevation map and meteorological data and others. The HSPF model was calibrated and validated using the observed water quality data from 2000 to 2016. For water quality simulation, we calculated the generated and discharge loads of the population, livestock, industry and land use following the guideline provided by the Ministry of Environment. The pollutant data were obtained from National Institute of Environmental Research (NIER). The monthly discharge load were estimated by applying the delivery rate. The calibration and validation results showed that the annual mean BOD had a difference of 0.22 mg/L and an error of ±13 %, T-N had a difference of 0.66 mg/L and an error of ±16 % and T-P had a difference of 0.027 mg/L and an error of ±13 %. In order to evaluate the nonpoint pollutants management effects, we applied livestock reduction scenarios because livestock consists of the largest portion of pollutants. As a result of the 20 % of livestock reduction, BOD, T-N and T-P decreased by 3 %, 1 % and 3 %, respectively. When 40 % of livestock reduction was applied, BOD, T-N and T-P decreased by 5 %, 3 % and 4 %, respectively. Based on the results of this study, effective pollutant management methods can be applied to improve the water quality and achieve the target water quality of Hapcheon dam watershed.

A Study on the Estimation Methods of Nonpoint Pollutant Unit Load - Focus on Nonpoint Pollutant Unit Load in Paddy Field - (비점오염 발생 원단위 산정방법에 대한 고찰 - 논 비점오염 원단위를 중심으로 -)

  • Choi, DongHo;Choi, Soon-Kun;Kim, Min-Kyeong;Hur, Seung-Oh;Hong, Sung Chang;Yeob, So-Jin;Yoon, KwangSik
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.61 no.3
    • /
    • pp.15-22
    • /
    • 2019
  • In order to preserve water environment, Total Maximum Daily Load(TMDL) is used to manage the total amount of pollutant from various sources, and the annual average load of source is calculated by the unit load method. Determination of the unit load requires reliable data accumulation and analysis based on a reasonable estimation method. In this study, we propose a revised unit load estimation method by analyzing the unit load calculation procedure of National Institute of Environment Research(NIER) method. Both methods were tested using observed runoff ratio and water quality data of rice paddy fields. The estimated values with the respective NIER and revised NIER methods were highly correlated each other. However, the Event Mean Concentration(EMC) and the runoff ratio considered in the NIER method appeared to be influenced by rainfall classes, and the difference in unit load increases as the runoff and EMC increase. The error can be further increased when the EMC and runoff ratio are changed according to changes in rainfall patterns by climate change and change of agricultural activities. Therefore, it is recommended to calculate unit load by applying the revised NIER method reflecting the non point pollution runoff characteristics for different rainfall classes.

Evaluation of Runoff and Pollutant Loads using L-THIA 2012 Runoff and Pollutant Auto-calibration Module and Ranking of Pollutant Loads Potential (L-THIA 2012 유출 및 수질 자동 보정 모듈을 이용한 유출/비점부하량 산정 및 비점오염 부하량 포텐셜 등급화)

  • Jang, Chunhwa;Kum, Donghyuk;Ha, Junsoo;Kim, Kyoung-Soon;Kang, Dong Han;Kim, Keuk-Tai;Shin, Dong Suk;Lim, Kyoung Jae
    • Journal of Korean Society on Water Environment
    • /
    • v.29 no.2
    • /
    • pp.184-195
    • /
    • 2013
  • Urbanization from agricultural/forest areas has been causing increased runoff and pollutant loads from it. Thus, numerous models have been developed to estimate NPS loading from urban area and Long-Term Hydrologic Impact Analysis (L-THIA) model has been used to evaluate effects of landuse changes on runoff and pollutant loads. However, the L-THIA model could not consider rainfall intensity in runoff evaluation. Therefore, the L-THIA model, capable of simulating runoff using 10-minute rainfall data, was applied to the study areas for evaluation of estimated runoff and NPS. The estimated Nash-Sutcliffe coefficient (NSE) values were over 0.6 for runoff, BOD, TN, and TP for most sites and watershed. The calibrated model was further extended to other counties for pollutant load potential evaluation. Pollutant load potential maps were developed and target areas were identified. As shown in this study, the L-THIA 2012 can be used for evaluation runoff and pollutant loads with limited data sets and its estimation could be used in identifying pollutant load hot spot areas for implementation of site-specific Best Management Practices.

A Comparative Study on the Runoff Characteristics from Watershed Using SWAT and HSPF (SWAT과 HSPF의 유출특성 비교)

  • Hwang, Ha-Sun;Yoon, Chun-Gyeng
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 2002.10a
    • /
    • pp.457-460
    • /
    • 2002
  • Development and application of nonpoint pollutant source model need pertinent runoff simulation for expecting good simulation result of yield of nonpont pollutant and it's move. this study purpose was compare to runoff height among Observed of Regression, HSPF and SWAT in hukchun basis loacated Gyeonggi province yangpeong-gun in two years($1998{\sim}1999$). Result, runoff height were Regression, SWAT, HSPF is 2578.96, 2526.44, 2547.21mm respectively, Nash-Schutcliff' simulation efficiency, compare to observed, was 70.22, 73.71% respectively so two simulation run off height was pertinent. If Regression method use excess observed arrange, it include error. so it's importance using pertinent arrange of observed runoff height.

  • PDF

Determination on the component arrangement of a hybrid rain garden system for effective stormwater runoff treatment (강우유출수 처리를 위한 하이브리드 빗물정원 시스템의 구성요소 배열 연구)

  • Flores, Precious Eureka D.;Geronimo, Franz Kevin F.;Alihan, Jawara Christian P.;Kim, Lee-Hyung
    • Journal of Wetlands Research
    • /
    • v.19 no.3
    • /
    • pp.271-278
    • /
    • 2017
  • Low impact development (LID) technology has been recently applied for the treatment of nonpoint source pollutants. Rain garden is one of the widely used LIDs since it utilizes various mechanisms such as biological and physico-chemical treatment to reduce pollutants. However, problem such as clogging has been one of the issues encountered by the rain garden that do not undergo constant maintenance. Therefore, this research was conducted to develop and determine the component arrangement of a rain garden system for a more efficient volume and pollutant reduction. Two hybrid rain garden systems having different characteristics were developed and evaluated to determine the optimum design and arrangement of the system. The results showed that the components arranged in a series manner showed a volume reduction of 93% and a pollutant reduction efficiency of approximately 99%, 93% and 95% was observed for particulates, nutrients and heavy metals, respectively. While when the system is connected in a combined series-parallel, the volume and average pollutant reduction efficiency for the TSS, nutrients and heavy metals are 65%, 94%, 80% and 85%, respectively. Moreover, the component arrangement in the order of sedimentation tank, infiltration tank and plant bed exhibited a high pollutant reduction efficiency compared when the infiltration tank and plant bed were interchanged. The findings of this research will help in the further development and optimization of rain garden systems.