• 제목/요약/키워드: nonpalpable breast lesion

검색결과 3건 처리시간 0.016초

Applicability of Radioguided Occult Lesion Localization for Non-Palpable Benign Breast Lesions, Comparison with Wire Localization, a Clinical Trial

  • Alikhassi, Afsaneh;Saeed, Farzanefar;Abbasi, Mehrshad;Omranipour, Ramesh;Mahmoodzadeh, Habibollah;Najafi, Massoome;Gity, Masoumeh;Kheradmand, Ali
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제17권7호
    • /
    • pp.3185-3190
    • /
    • 2016
  • Background: This study was designed to compare radioguided versus routine wire localization of nonpalpable non-malignant breast lesions in terms of efficacy for complete excision, ease of use, time saving, and cosmetic outcome. Materials and Methods: Patients with non-palpable breast masses and non-malignant core biopsy results who were candidates for complete surgical lumpectomy were enrolled and randomly assigned to radioguided or wire localization groups. Radiologic, surgical, and pathologic data were collected and analyzed to determine the difficulty and duration of each procedure, ease of use, accuracy, and cosmetic outcomes. Results: This prospective randomized study included 60 patients, randomly divided into wire guided localization (WGL) or radioguided occult lesion localization (ROLL) groups. The mean duration of localization under ultrasound guidance was shorter in the ROLL group (14.4 min) than in the WGL group (16.5 min) (p<0.001). The ROLL method was significantly easier for radiologists (p=0.0001). The mean duration of the surgical procedure was 22.6 min (${\pm}10.3min$) for ROLL and 23.6 min (${\pm}9.6min$) for WGL (p=0.6), a non-significant difference. Radiography of the surgical specimens showed 100% lesion excision with clear margins, as proved by pathologic examination, with both techniques. The surgical specimens were slightly heavier in the ROLL group, but the difference was not significant (p=0.06). Conclusions: The ROLL technique provides effective, fast, and simple localization and excision of non-palpable non-malignant breast lesions.

컴퓨터보조진단을 이용한 유방 초음파영상에서의 미세석회화 검출 효율 (Detection Efficiency of Microcalcification using Computer Aided Diagnosis in the Breast Ultrasonography Images)

  • 이진수;고성진;강세식;김정훈;박형후;최석윤;김창수
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제35권3호
    • /
    • pp.227-235
    • /
    • 2012
  • 유방영상은 유방 전체의 재현 가능한 영상을 만들며, 만져지지 않는 조기 유방암의 가장 중요한 소견인 미세석회화와 종괴를 발견할 수 있어 유방 질환의 일차적인 선별검사로 이용되고 있다. 유방 병변의 미세석회화는 조기 유방암의 진단에 있어서 중요한 병변으로 보고되고 있지만 유방초음파 검사에서 검출이 어렵다. 본 연구에서는 유방초음파 영상에서 미세석회화 검출을 위해 6가지의 질감분석 파라미터를 이용하였으며, 정상 초음파영상과 미세석회화가 보이는 초음파 영상 간의 병변인식률을 알아보았다. 실험결과로는 유방촬영영상과 유방 초음파영상에서 병변을 구별하는 컴퓨터자동진단 인식률은 70~98%로 상당히 높은 결과를 나타내었다. ROC 분석에서도 평균대조도와 엔트로피 파라미터의 특이도는 다소 낮게 나타났으나, 나머지 4개 파라미터의 민감도와 특이도는 90% 이상을 나타내어 초음파영상에서 미세석회화 검출의 가능성을 보였다. 향후 6가지 질감분석 알고리즘들 외에 추가적인 파라미터 알고리즘의 연구가 계속 진행되어 컴퓨터자동진단의 실용화기반을 마련한다면 전문의 진단의 예비단계로서 더욱 중요한 의미를 가질 것이며, 유방암의 조기진단에 매우 유용할 것으로 사료된다.

Stereotactic Vacuum-Assisted Core Biopsy Results for Non-Palpable Breast Lesions

  • Agacayak, Filiz;Ozturk, Alper;Bozdogan, Atilla;Selamoglu, Derya;Alco, Gul;Ordu, Cetin;Pilanci, Kezban Nur;Killi, Refik;Ozmen, Vahit
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제15권13호
    • /
    • pp.5171-5174
    • /
    • 2014
  • Background: The increase in breast cancer awareness and widespread use of mammographic screening has led to an increased detection of (non-palpable) breast cancers that cannot be discovered through physical examination. One of the methods used in the diagnosis of these cancers is vacuum-assisted core biopsy, which prevents a considerable number of patients from undergoing surgical procedures. The aim of this study was to present the results of stereotactic vacuum-assisted core biopsy for suspicious breast lesions. Materials and Methods: Files were retrospectively scanned and data on demographic, radiological and pathological findings were recorded for patients who underwent stereotactic vacuum-assisted core biopsy due to suspicious mammographic findings at the Interventional Radiology Centre of the Florence Nightingale Hospital between January 2010, and April 2013. Statistical analysis was carried out using Pearson's Chi-square, continuity correction, and Fisher's exact tests. Results: The mean age of the patients was 47 years (range: 36-70). Biopsies were performed due to BIRADS 3 lesions in 8 patients, BIRADS 4 lesions in 77 patients, and BIRADS 5 lesions in 3 patients. Mammography elucidated clusters of microcalcifications in 73 patients (83%) and focal lesions (asymmetrical density, distortion) in 15 patients (17%). In terms of complications, 1 patient had a hematoma, and 2 patients had ecchymoses (3/88; 3.3%). The histopathologic results revealed benign lesions in 63 patients (71.6%) and malignant lesions in 25 patients (28.4%). The mean duration of the procedure was 37 minutes (range: 18-55). Although all of the BIRADS 3 lesions were benign, 22 (28.6%) of the BIRADS 4 lesions and all of the BIRADS 5 lesions were malignant. Among the malignant cases, 80% were in situ, and 20% were invasive carcinomas. These patients underwent surgery. Conclusions: In cases where non-palpable breast lesions are considered to be suspicious in mammography scans, the vacuum-assisted core biopsy method provides an accurate histopathologic diagnosis thus preventing a significant number of patients undergoing unnecessary surgical procedures.