• 제목/요약/키워드: nonlinear SDOF system

검색결과 65건 처리시간 0.02초

Ductility and ductility reduction factor for MDOF systems

  • Reyes-Salazar, Alfredo
    • Structural Engineering and Mechanics
    • /
    • 제13권4호
    • /
    • pp.369-385
    • /
    • 2002
  • Ductility capacity is comprehensively studied for steel moment-resisting frames. Local, story and global ductility are being considered. An appropriate measure of global ductility is suggested. A time domain nonlinear seismic response algorithm is used to evaluate several definitions of ductility. It is observed that for one-story structures, resembling a single degree of freedom (SDOF) system, all definitions of global ductility seem to give reasonable values. However, for complex structures it may give unreasonable values. It indicates that using SDOF systems to estimate the ductility capacity may be a very crude approximation. For multi degree of freedom (MDOF) systems some definitions may not be appropriate, even though they are used in the profession. Results also indicate that the structural global ductility of 4, commonly used for moment-resisting steel frames, cannot be justified based on this study. The ductility of MDOF structural systems and the corresponding equivalent SDOF systems is studied. The global ductility values are very different for the two representations. The ductility reduction factor $F_{\mu}$ is also estimated. For a given frame, the values of the $F_{\mu}$ parameter significantly vary from one earthquake to another, even though the maximum deformation in terms of the interstory displacement is roughly the same for all earthquakes. This is because the $F_{\mu}$ values depend on the amount of dissipated energy, which in turn depends on the plastic mechanism, formed in the frames as well as on the loading, unloading and reloading process at plastic hinges. Based on the results of this study, the Newmark and Hall procedure to relate the ductility reduction factor and the ductility parameter cannot be justified. The reason for this is that SDOF systems were used to model real frames in these studies. Higher mode effects were neglected and energy dissipation was not explicitly considered. In addition, it is not possible to observe the formation of a collapse mechanism in the equivalent SDOF systems. Therefore, the ductility parameter and the force reduction factor should be estimated by using the MDOF representation.

비선형 변위모드법을 적용한 복합구조물의 내진성능평가 (Evaluation of Seismic Performance of Mixed Building Structures by using the Nonlinear Displacement Mode Method)

  • 김부식;송호산
    • 한국지진공학회논문집
    • /
    • 제7권6호
    • /
    • pp.71-80
    • /
    • 2003
  • 구조물의 내진 성능을 정확히 평가하기 위해서는 비선형 시각 이력 해석이 필요하지만 실용성과 단순성 측면에서 약산법이 대안이 될 수 있으며, 다층 구조물을 등가 단자유도계로 치환할 때 다층 구조물의 모드벡터는 구조물이 탄성 또는 탄소성 상태에 상관없이 탄성 상태에서의 모드 형상으로 가정되지만, 항복이 발생한 후 증가하는 하중단계에서 구조물은 비탄성으로 되기 때문에 변위 모드 특성들도 변화된다. 본 논문은 항복 이후의 구조물의 모드 변화를 고려한 비선형 변위모드를 이용하여 다자유도계를 등가 단자유도계로 변환하는 방법을 제시하였으며, 변환된 등가 단자유도계의 변위응답을 근거로 추정한 복합 구조물의 최상층 변위와 실제 지진교란을 받는 복합 구조물의 비선형 동적해석에 의한 최상층 변위를 비교함으로서 복합구조물의 지진응답예측을 위한 비선형 변위모드법의 적용성과 신뢰성을 검토하였다.

Unscented Kalman Filter를 이용한 비선형 동적 구조계의 시간영역 규명기법 (Time Domain Identification of nonlinear Structural Dynamic Systems Using Unscented Kalman Filter)

  • 윤정방
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2001년도 춘계학술대회 논문집
    • /
    • pp.180-189
    • /
    • 2001
  • In this study, recently developed unscented Kalman filter (UKF) technique is studied for identification of nonlinear structural dynamic systems as an alternative to the extended Kalman filter (EKF). The EKF, which was originally developed as a state estimator for nonlinear systems, has been frequently employed for parameter identification by introducing the state vector augmented with the unknown parameters to be identified. However, the EKF has several drawbacks such as biased estimations and erroneous estimations especially for highly nonlinear dynamic systems due to its crude linearization scheme. To overcome the weak points of the EKF, the UKF was recently developed as a state estimator. Numerical simulation studies have been carried out on nonlinear SDOF system and nonlinear MDOF system. The results from a series of numerical simulations indicate that the UKF is superior to the EKF in the system identification of nonlinear dynamic systems especially highly nonlinear systems.

  • PDF

Unscented Kalman Filter를 이용한 비선형 동적 구조계의 시간영역 규명기법 (Time Domain Identification of Nonlinear Structural Dynamic Systems Using Unscented Kalman Filter)

  • Yun, Chung-Bang;Koo, Ki-Young
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2001년도 가을 학술발표회 논문집
    • /
    • pp.117-126
    • /
    • 2001
  • In this study, the recently developed unscented Kalman filter (UKF) technique is studied for identification of nonlinear structural dynamic systems as an alternative to the extended Kalman filter (EKF). The EKF, which was originally developed as a state estimator for nonlinear systems, has been frequently employed for parameter identification by introducing the state vector augmented with the unknown parameters to be identified. However, the EKF has several drawbacks such as biased estimations and erroneous estimations especially for highly nonlinear dynamic systems due to its crude linearization scheme. To overcome the weak points of the EKF, the UKF was recently developed as a state estimator. Numerical simulation studies have been carried out on nonlinear SDOF system and nonlinear MDOF system. The results from a series of numerical simulations indicate that the UKF is superior to the EKF in the system identification of nonlinear dynamic systems especially highly nonlinear systems.

  • PDF

Evaluation of N2 method for damage estimation of MDOF systems

  • Yaghmaei-Sabegh, Saman;Zafarvand, Sadaf;Makaremi, Sahar
    • Earthquakes and Structures
    • /
    • 제14권2호
    • /
    • pp.155-165
    • /
    • 2018
  • Methods based on nonlinear static analysis as simple tools could be used for the seismic analysis and assessment of structures. In the present study, capability of the N2 method as a well-known nonlinear analysis procedure examines for the estimation of the damage index of multi-storey reinforced concrete frames. In the implemented framework, equivalent single-degree-of-freedom (SDOF) models are utilized for the global damage estimation of multi-degree-of-freedom (MDOF) systems. This method does not require high computational analysis and subsequently decreases the required time of seismic design and assessment process. To develop the methodology, RC frames with period range from 0.4 to 2.0 s under 40 records are studied. The effectiveness of proposed technique is evaluated through numerical study under near- and far-field earthquake ground motions. Finally, the results of developed models are compared with two other simplified schemes along with nonlinear time history analysis results of multi-storey frames. To improve the accuracy of damage estimation, a modified relation is presented based on the N2 method results for near- and far-field earthquakes.

제진장치가 설치된 구조물의 등가감쇠비 (Closed Form Formulas for Equivalent Damping Ratios of a Linear Structure Equipped with Damping Devices)

  • Hwang, Jae-Seung;Lee, Sang-Hyun;Min, Kyung-Won
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2002년도 가을 학술발표회 논문집
    • /
    • pp.370-377
    • /
    • 2002
  • Hwang et al (2001) proposed a new method for an evaluation of equivalent damping ratios of a linear structure with linear or nonlinear damping devices. This procedure has a disadvantage that it requires time history analysis for the whole system including damping devices, which may be troublesome for practical application. To tackle this problem closed form formulas for equivalent damping ratios are proposed in this study. It is assumed that the responses of MDOF system can be reproduced by an equivalent SDOF system which vibrates in a fundamental mode. The numerical analyses of a ten-story building equipped with linear viscous damper or active mass damper or friction damper show the effectiveness of equivalent SDOF model and closed form formulas.

  • PDF

배율조정 및 스펙트럼 맞춤 입력지반운동 모델에 대한 비선형 단자유도 시스템의 파손확률 (Failure Probability of Nonlinear SDOF System Subject to Scaled and Spectrum Matched Input Ground Motion Models)

  • 김동석;고현무;최창열;박원석
    • 한국지진공학회논문집
    • /
    • 제12권1호
    • /
    • pp.11-20
    • /
    • 2008
  • 비선형 구조계의 확률론적 지진해석 방법 중 대표적인 것은 지진 재해도 수준에 해당하는 입력지반운동 모델을 사용한 시간이력을 수행하여 그 응답의 확률분포를 예측하는 것이다. 이 연구에서는 널리 사용되고 있는 두 가지 입력지반운동 모델에 따른 구조계 응답의 분포특성 및 파손확률의 차이와 그 원인을 분석한다 입력지반운동 모델로는 실제 지진기록을 배율 조정하여 사용하는 배율조정 입력지반운동과 설계 응답스펙트럼에 상응하는 인공 지진기록을 사용하는 스펙트럼 맞춤 입력지반운동 두 가지를 고려한다. 동일한 지진재해도 수준을 고려한 해석결과 설계 응답스펙트럼에 상응하는 인공 지진기록을 사용한 입력지반운동 모델은 실제 지진기록을 배율 조정한 입력지반운동 모델보다 평균적으로 응답을 크게 평가하였고 이로 인해 파손확률 또한 더 큰 것으로 나타났다 이러한 경향은 연약한 지반에서 더욱 현저한 것으로 나타났다. 이러한 입력지반운동 모델에 따른 파손확률의 차이는 스펙트럼 맞춤 입력지반운동의 목표로 사용된 도로교 설계기준의 설계 응답스펙트럼이 실제 지진기록의 응답스펙트럼보다 장주기로 갈수록 응답을 크게 평가하도록 보수적으로 만들어졌기 때문인 것으로 나타났다.

다층 비좌굴 가새골조와 등가 단자유도계의 에너지 요구량의 비교 (Comparison of Energy Demand in Multi-Story Buckling Restrained Braced Frame and Equivalent SDOF System)

  • 김진구;원영섭
    • 한국전산구조공학회논문집
    • /
    • 제16권2호
    • /
    • pp.173-182
    • /
    • 2003
  • 비선형 정적해석 및 에너지를 이용한 설계방법에서는 구조물을 등가의 단자유도계로 치환하여 해석하는 것이 일반적이다. 본 연구에서는 지진하중에 의한 3층, 8층, 20층 철골 모멘트저항골조(MRF), 비좌굴 가새골조(BRBF)와 힌지접합 비좌굴 가새골조 (DTBF) 구조물의 에너지 요구량을 등가 단자유도계 시스템(ESDOF)의 에너지 요구량과 비교하여 등가단자유도계로 치환하는 방법의 타당성을 검토하였다 입력에너지와 이력에너지를 산정하기 위하여 연암 지반, 연약한 토사, 단층 근처의 지반에서 계측된 60개의 지진을 사용하였으며, 모드 질량계수가 0.8보다 작은 경우 ESDOF로 변환할 때 고차모드의 효과를 고려하였다. 연구결과에 따르면 3층과 8층 MRF와 DTBF에서의 이력에너지와 입력에너지는 ESDOF의 해석결과와 비교적 잘 일치하였다. 그러나 20층 BRBF에서는 ESDOF의 결과가 본 구조물의 결과를 과소평가하는 것으로 나타났다.

비선형 시간 이력법에 의한 목조 가옥의 지진응답해석 (Seismic Response Analysis of Wood Structure Using Nonlinear Time History Method)

  • 김재관
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 1998년도 춘계 학술발표회 논문집 Proceedings of EESK Conference-Spring 1998
    • /
    • pp.212-219
    • /
    • 1998
  • Dynamic analyses are performed for the wood structure modeled as a SDOF hysteretic system. The hysteresis model presented is a modified version of Takeda model. The comparison between the results of numerical simulation and the experimental results show good agreements in overall tendencies. The response of wood structure subjected to artificially generated earthquakes considering site effects is studied. It appears that the response is very strongly influenced by the intensity and the frequency contents of the ground motion.

  • PDF

Soil interaction effects on the performance of compliant liquid column damper for seismic vibration control of short period structures

  • Ghosh, Ratan Kumar;Ghosh, Aparna Dey
    • Structural Engineering and Mechanics
    • /
    • 제28권1호
    • /
    • pp.89-105
    • /
    • 2008
  • The paper presents a study on the effects of soil-structure-interaction (SSI) on the performance of the compliant liquid column damper (CLCD) for the seismic vibration control of short period structures. The frequency-domain formulation for the input-output relation of a flexible-base structure with CLCD has been derived. The superstructure has been modeled as a linear, single degreeof-freedom (SDOF) system. The foundation has been considered to be attached to the underlying soil medium through linear springs and viscous dashpots, the properties of which have been represented by complex valued impedance functions. By using a standard equivalent linearization technique, the nonlinear orifice damping of the CLCD has been replaced by equivalent linear viscous damping. A numerical stochastic study has been carried out to study the functioning of the CLCD for varying degrees of SSI. Comparison of the damper performance when it is tuned to the fixed-base structural frequency and when tuned to the flexible-base structural frequency has been made. The effects of SSI on the optimal value of the orifice damping coefficient of the damper has also been studied. A more convenient approach for designing the damper while considering SSI, by using an established model of a replacement oscillator for the structure-soil system has also been presented. Finally, a simulation study, using a recorded accelerogram, has been carried out on the CLCD performance for the flexible-base structure.