• 제목/요약/키워드: non-linear static analysis

검색결과 191건 처리시간 0.028초

리엔트런트 패널의 전면볼록성에 대한 정량적 해석

  • 허정민;이지환
    • EDISON SW 활용 경진대회 논문집
    • /
    • 제5회(2016년)
    • /
    • pp.228-233
    • /
    • 2016
  • Auxetic material is a material which has negative Poisson's ratio(NPR). Auxetic material shows some distinctive property like high energy absorbing property and high shear modulus. Among these, synclastic curvature is very interesting characteristic. When synclastic-curvature-material bends, it changes its shape like dome, contrary to non-auxetic material which changes its shape like saddle(anticlastic). This distinctive property could make it easy to manufacture curved structure like nose cone or wing panel in aerospace engineering. In this study, we studied a quantitative analysis about synclastic curvature of re-entrant panel with finite element model. We suggested a concept 'Degree of Synclasticity(DOS)', which means a ratio of curvature of load-direction and load-orthogonal direction. We studied the variation of DOS with two factor, unit cell inner angle(${\theta}$) and load position angle(${\phi}$). DOS decreases as ${\theta}$ increases because the unit cell goes out of auxetic-shape. As ${\phi}$ varies, DOS changes in a large range. So proper optimization of ${\phi}$ would be needed for application.

  • PDF

A new design method for site-joints of the tower crane mast by non-linear FEM analysis

  • Ushio, Yoshitaka;Saruwatari, Tomoharu;Nagano, Yasuyuki
    • Advances in Computational Design
    • /
    • 제4권4호
    • /
    • pp.343-365
    • /
    • 2019
  • Among the themes related to earthquake countermeasures at construction sites, those for tower cranes are particularly important. An accident involving the collapse of a crane during the construction of a skyscraper has serious consequences, such as human injury or death, enormous repair costs, and significant delays in construction. One of the causes of deadly tower crane collapses is the destruction of the site joints of the tower crane mast. This paper proposes a new design method by static elastoplastic finite element analysis using a supercomputer for the design of the end plate-type tensile bolted joints, which are generally applied to the site joints of a tower crane mast. This new design method not only enables highly accurate and reliable joint design but also allows for a design that considers construction conditions, such as the introduction of a pre-tension axial force on the bolts. By applying this new design method, the earthquake resistance of tower cranes will undoubtedly be improved.

Evaluation of seismic performance factors for tension-only braced frames

  • Shariati, Mahdi;Lagzian, Majid;Maleki, Shervin;Shariati, Ali;Trung, Nguyen Thoi
    • Steel and Composite Structures
    • /
    • 제35권4호
    • /
    • pp.599-609
    • /
    • 2020
  • The tension-only braced frames (TOBFs) are widely used as a lateral force resisting system (LFRS) in low-rise steel buildings due to their simplicity and economic advantage. However, the system has poor seismic energy dissipation capacity and pinched hysteresis behavior caused by early buckling of slender bracing members. The main concern in utilizing the TOBF system is the determination of appropriate performance factors for seismic design. A formalized approach to quantify the seismic performance factor (SPF) based on determining an acceptable margin of safety against collapse is introduced by FEMA P695. The methodology is applied in this paper to assess the SPFs of the TOBF systems. For this purpose, a trial value of the R factor was first employed to design and model a set of TOBF archetype structures. Afterwards, the level of safety against collapse provided by the assumed R factor was investigated by using the non-linear analysis procedure of FEMA P695 comprising incremental dynamic analysis (IDA) under a set of prescribed ground motions. It was found that the R factor of 3.0 is appropriate for safe design of TOBFs. Also, the system overstrength factor (Ω0) was estimated as 2.0 by performing non-linear static analyses.

Experimental and numerical investigation on in-plane behaviour of hollow concrete block masonry panels

  • Murthy, A. Rama Chandra;Ganapathi, S. Chitra;Iyer, Nagesh R.;Lakshmanan, N.;Bhagavan, N.G.
    • Computers and Concrete
    • /
    • 제10권1호
    • /
    • pp.1-18
    • /
    • 2012
  • This paper presents the details of studies conducted on hollow concrete block masonry (HCBM) units and wall panels. This study includes, compressive strength of unit block, ungrouted and grouted HCB prisms, flexural strength evaluation, testing of HCBM panels with and without opening. Non-linear finite element (FE) analysis of HCBM panels with and without opening has been carried out by simulating the actual test conditions. Constant vertical load is applied on the top of the wall panel and then lateral load is applied in incremental manner. The in-plane deformation is recorded under each incremental lateral load. Displacement ductility factors and response reduction factors have been evaluated based on experimental results. From the study, it is observed that fully grouted and partially reinforced HCBM panel without opening performed well compared to other types of wall panels in lateral load resistance and displacement ductility. In all the wall panels, shear cracks originated at loading point and moved towards the compression toe of the wall. The force reduction factor of a wall panel with opening is much less when compared with fully reinforced wall panel with no opening. The displacement values obtained by non-linear FE analysis are found to be in good agreement with the corresponding experimental values. The influence of mortar joint has been included in the stress-strain behaviour as a monolith with HCBM and not considered separately. The derived response reduction factors will be useful for the design of reinforced HCBM wall panels subjected to lateral forces generated due to earthquakes.

A simplified model proposal for non-linear analysis of buildings

  • Abdul Rahim Halimi;Kanat Burak Bozdogan
    • Earthquakes and Structures
    • /
    • 제24권5호
    • /
    • pp.353-364
    • /
    • 2023
  • In this study, a method has been proposed for the static and dynamic nonlinear analysis of multi-storey buildings, which takes into account the contribution of axial deformations in vertical load-bearing elements, which are especially important in tall and narrow structures. Shear deformations on the shear walls were also taken into account in the study. The presented method takes into account the effects that are not considered in the fishbone and flexural-shear beam models developed in the literature. In the Fishbone model, only frame systems are modeled. In the flexural shear beam model developed for shear wall systems, shear deformations and axial deformations in the walls are neglected. Unlike the literature, with the model proposed in this study, both shear deformations in the walls and axial deformations in the columns and walls are taken into account. In the proposed model, multi-storey building is represented as a sandwich beam consisting of Timoshenko beams pieced together with a double-hinged beam. At each storey, the total moment capacities of the frame beams and the coupled beams in the coupled shear walls are represented as the equivalent shear capacity. On the other hand, The sums of individual columns and walls moment at the relevant floor level are represented as equivalent moment capacity at that floor level. At the end of the study, examples were solved to show the suitability of the proposed method in this study. The SAP2000 program is employed in analyses. In a conclusion, it is observed that among the solved examples, the proposed sandwich beam model gives good results. As can be seen from these results, it is seen that the presented method, especially in terms of base shear force, gives very close results to the detailed finite element method.

정적 및 동적안전성이 우수한 SUPER concrete 100MPa 활용 부잔교 개발 (Development of static and dynamic stability utilizing superior SUPER concrete 100MPa pontoon)

  • 임형주;윤식재;이상희
    • 한국항해항만학회:학술대회논문집
    • /
    • 한국항해항만학회 2016년도 춘계학술대회
    • /
    • pp.135-136
    • /
    • 2016
  • 초고강 콘크리트를 활용한 부잔교는 강재부잔교에 비해 부식의 염려가 없어 내구성과 동적안전성이 우수하고, 일반 콘크리트에 비해 경량구조물로 건현확보가 유리하다. 현재 국내 연구개발 결과 SUPER concrete는 100MPa까지는 강섬유의 배합없이 일반골재만으로 배합이 가능하여 고부식성 환경의 항만구조물의 내구성에 적합한 강도이다. 부잔교는 상부슬래브에 작용하는 차량(DB-18) 또는 군집하중(5kN/m2)과, 외부 벽체 및 하부슬래브에 작용하는 파력의 수평과 양력성분을 견디도록 하여야 한다. 설계 파랑은 인천 연평도지역을 대상으로 50년 빈도 유의파와 주기에 해당하는 파력을 산정하여 X,Y축 위치에 따라 수평 및 양력성분을 재하하였다. 전체계 해석시 부잔교는 연직방향 경계조건이 없는 상태에서 부력 산정이 가능하도록 기하비선형 및 시간이력해석기법을 응용하였다(Strand 7). 부잔교 슬래브에 대해서는 실물모형실험을 통해 DB-18하중 재하에 따른 안전성을 확인하였다.

  • PDF

A simple approach for quality evaluation of non-slender, cast-in-place piles

  • Zhang, Ray Ruichong
    • Smart Structures and Systems
    • /
    • 제4권1호
    • /
    • pp.1-17
    • /
    • 2008
  • This study proposes a conceptual framework of in-situ vibration tests and analyses for quality appraisal of non-slender, cast-in-place piles with irregular cross-section configuration. It evaluates a frequency index from vibration recordings to a series of impulse loadings that is related to total soil-resistance forces around a pile, so as to assess if the pile achieves the design requirement in terms of bearing capacity. In particular, in-situ pile-vibration tests in sequential are carried out, in which dropping a weight from different heights generates series impulse loadings with low-to-high amplitudes. The high-amplitude impulse is designed in way that the load will generate equivalent static load that is equal to or larger than the designed bearing capacity of the pile. This study then uses empirical mode decomposition and Hilbert spectral analysis for processing the nonstationary, short-period recordings, so as to single out with accuracy the frequency index. Comparison of the frequency indices identified from the recordings to the series loadings with the design-based one would tell if the total soil resistance force remains linear or nonlinear and subsequently for the quality appraisal of the pile. As an example, this study investigates six data sets collected from the in-situ tests of two piles in Taipu water pump project, Jiangshu Province of China. It concludes that the two piles have the actual axial load capacity higher than the designed bearing capacity. The true bearing capacity of the piles under investigation can be estimated with accuracy if the amplitude of impact loadings is further increased and the analyses are calibrated with the static testing results.

일반화된 반데르발스 상태방정식을 이용한 비이상적 입자 상호작용을 갖는 알칸(선형성) 및 알킬 아민류(쌍극자성)에 대한 임계 영역 특성분석 (The Description of Near-Critical Region for the Non-Ideal Inter-Particle Interacting Molecules such as n-Alkane(linear) and Alkyl-Amine(dipolar) by using Generalized van der Waals Equation of States)

  • 김지범;이석배;전준현
    • Korean Chemical Engineering Research
    • /
    • 제48권2호
    • /
    • pp.224-231
    • /
    • 2010
  • 최근 발표된 GvdW(Generalized van der Waals) EOS에서는 상호작용이 vdWf(van der Waals force)뿐이라고 여겨지는 구체특성의 비선형적 입자에 대해 임계영역에서의 상태 특성이 잘 기술될 수 있음을 보였다. 그러나 기존의 논문에서는 선형성을 갖는 입자의 형태나 정전기적 인력 등 추가적인 상호작용이 존재하는 입자에 대해서도 GvdW가 정확성을 나타내는지에 대한 분석이 이루어지지 않아, GvdW의 범용성에 대한 논란의 여지가 남아있다. 따라서 본 논문에서는 선형성을 갖는 입자인 포화 알칸 유도체 류(R=methane, ethane, propane, butane)와 정전기적 인력이 극한적으로 나타나는 포화 아민 유도체 류($RNH_2$, R=methyl-, ethyl-, propyl-amine)에 대한 임계영역 시뮬레이션을 위하여 이들 입자들에 대한 GvdW의 파라미터 값을 정의하였으며, 이를 바탕으로 최근에 발표된 기존의 상태방정식들과 비교 분석하였다. 시뮬레이션 결과 포화 알칸 유도체 류와 포화 아민 유도체 류 입자에 대하여 GvdW는 기존의 방정식들보다 측정값에 더 가까운 정확한 임계영역 특성이 나타남을 확인할 수 있었다. 특히 분자량이 큰 부탄에 있어서는 GvdW EOS만이 임계점에 정확하게 근접함을 알 수 있었다.

재료 특성이 철근 콘크리트 슬래브의 동적 거동에 미치는 영향 (Effects of Material Characteristics on the Dynamic Response of the Reinforced Concrete Slabs)

  • 오경윤;조진구;홍종현
    • 한국농공학회논문집
    • /
    • 제49권4호
    • /
    • pp.43-49
    • /
    • 2007
  • The reinforced concrete slab is one of main structure members in the construction industry sector. However, most of researches regarding to RC slabs have been focused on two-dimensional Mindlin-type plate element on the basis of laminated plate theory since three-dimensional solid element has a lot of difficulties in finite element formulation and costs in CPU time. In reality, the RC slabs are subjected to dynamic loads like a heavy traffic vehicle load, and thus should insure the safety from the static load as well as dynamic load. Once we can estimate the dynamic behaviour of RC slabs exactly, it will be very helpful for design of it. In this study, the 20-node solid element has been used to analyze the dynamic characteristics of RC slabs with clamped edges. The elasto-visco plastic model for material non-linearity and the smeared crack model have been adopted in the finite element formulation. The applicability of the proposed finite element has been tested for dynamic behaviour of RC slabs with respect to characteristics of concrete materials in terms of cracking stress, crushing strain, fracture energy and Poisson's ratio. The effect on dynamic behaviour is dependent on not crushing strain but cracking stress, fracture energy and Poisson's ratio. In addition to this, it is shown the damping phenomenon of RC slabs has been identified from the numerical results by using Rayleigh damping.

조적허리벽이 있는 비내진 학교시설의 내진성능평가를 위한 반응수정계수 (Response Modification Factors for Seismic Performance Evaluation of Non-seismic School Buildings with Partial Masonry Infills)

  • 김범석;박지훈
    • 한국지진공학회논문집
    • /
    • 제23권1호
    • /
    • pp.71-82
    • /
    • 2019
  • Most school buildings consist of reinforced concrete (RC) moment frames with masonry infills. The longitudinal direction frames of those school buildings are relatively weak due to the short-column effects caused by the partial masonry infills and need to be evaluated carefully. In 'Manual for Seismic Performance Evaluation and Retrofit of School Facilities' published in 2018, response modification factor of 2.5 is applied to non-seismic RC moment frames with partial masonry infills, but sufficient verification of the factor has not been reported yet. Therefore, this study conducted seismic performance evaluation of planar RC moment frames with partial masonry infills in accordance with both linear analysis and nonlinear static analysis procedures presented in the manual. The evaluation results from the different procedures are compared in terms of assessed performance levels and number of members not meeting target performance objectives. Finally, appropriate response modification factors are proposed with respect to a shear-controlled column ratio.