• Title/Summary/Keyword: non-data aided

Search Result 59, Processing Time 0.031 seconds

CAE Analysis of Powder Injection Molding Process for Dental Scaler Mold (치과용 스케일러 금형의 분말사출성형 CAE 해석설계)

  • Ko Y. B.;Park H. P.;Chung S. T.;Rhee B. O.;Hwang C. J.
    • Transactions of Materials Processing
    • /
    • v.14 no.6 s.78
    • /
    • pp.570-576
    • /
    • 2005
  • Powder Injection Molding(PIM) has recently been recognized as an advanced manufacturing technology for low-cost mass production of metal or ceramic parts of complicated geometry With this regards, design technology of dental scaler tip PIM mold, which has complex shape and small core pin (diameter=0.6mm), with the help of computer-aided analysis of powder injection molding process was developed. Computer-aided analysis for dental scaler tip mold was implemented by finite element method with non-Newtonian fluid, modified Cross model viscosity, PvT data of powder/binder mixture. Compter-aided analysis results, such as filling pattern, weldline formation, air vent position prediction were compared with experimental result, and eventually have been shown good agreement. The core pin (diameter=0.6mm) deflection analysis of dental scaler tip PIM mold during PIM filling process was also investigated before mold fabrication.

Biased SNR Estimation using Pilot and Data Symbols in BPSK and QPSK Systems

  • Park, Chee-Hyun;Hong, Kwang-Seok;Nam, Sang-Won;Chang, Joon-Hyuk
    • Journal of Communications and Networks
    • /
    • v.16 no.6
    • /
    • pp.583-591
    • /
    • 2014
  • In wireless communications, knowledge of the signal-to-noise ratio is required in diverse communication applications. In this paper, we derive the variance of the maximum likelihood estimator in the data-aided and non-data-aided schemes for determining the optimal shrinkage factor. The shrinkage factor is usually the constant that is multiplied by the unbiased estimate and it increases the bias slightly while considerably decreasing the variance so that the overall mean squared error decreases. The closed-form biased estimators for binary-phase-shift-keying and quadrature phase-shift-keying systems are then obtained. Simulation results show that the mean squared error of the proposed method is lower than that of the maximum likelihood method for low and moderate signal-to-noise ratio conditions.

A Development of Automation Program for Forging Die Design of Non-Axisymmetric Parts (비축대칭 부품의 단조금형 설계용 자동화 프로그램 개발)

  • Kwon, Soon-Hong;Choi, Jong-Ung
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.5 no.1
    • /
    • pp.11-19
    • /
    • 2002
  • This study described computer aided die design system for cold forging of non-axisymmetric parts such as gears and splines. To design the cold forging die, an integrated approach based on a rule-base system and commercial F. E. code were adopted. This system is implemented on the personal computer and its environment is a commercial CAD package named as Auto CAD. The system includes four modules. In the initial data input module, variables which are necessary to design of die are inputted by user and die material are selected from the database according to the variables. In the analysis and redesign module, stress distribution acting on the designed die is analyzed by commercial FEM code NISA II with elastic mode. If die failure predicted, the designed die would modified in four ways to prevent die failure in both states of stress free and pressurizing. The developed system provides useful date and powerful capabilities for die design of non-axisymmetric parts.

  • PDF

ENHANCED FUZZY SLIDING MODE CONTROLLER FOR LAUNCH CONTROL OF AMT VEHICLE USING A BRUSHLESS DC MOTOR DRIVE

  • Zhao, Y.S.;Chen, L.P.;Zhang, Y.Q.;Yang, J.
    • International Journal of Automotive Technology
    • /
    • v.8 no.3
    • /
    • pp.383-394
    • /
    • 2007
  • Due to the clutch's non-linear dynamics, time-delays, external disturbance and parameter uncertainty, the automated clutch is difficult to control precisely during the launch process or automatic mechanical transmission (AMT) vehicles. In this paper, an enhanced fuzzy sliding mode controller (EFSMC) is proposed to control the automated clutch. The sliding and global stability conditions are formulated and analyzed in terms of the Lyapunov full quadratic form. The chattering phenomenon is handled by using a saturation function to replace the pure sign function and fuzzy logic adaptation system in the control law. To meet the real-time requirement of the automated clutch, the region-wise linear technology s adopted to reduce the fuzzy rules of the EFSMC. The simulation results have shown hat the proposed controller can achieve a higher performance with minimum reaching time and smooth control actions. In addition, our data also show that the controller is effective and robust to the parametric variation and external disturbance.

Shear bond strengths of aged and non-aged CAD/CAM materials after different surface treatments

  • Kilinc, Hamiyet;Sanal, Fatma Ayse;Turgut, Sedanur
    • The Journal of Advanced Prosthodontics
    • /
    • v.12 no.5
    • /
    • pp.273-282
    • /
    • 2020
  • PURPOSE. To assess shear bond strengths (SBS) of resin composites on aged and non-aged prosthetic materials with various surface treatments. MATERIALS AND METHODS. Cerasmart (CE), Vita Enamic (VE), Vita Mark II (VM), and IPS e.max CAD (EC) blocks were sliced, and rectangular-shaped specimens (14 × 12 × 1.5 mm; N = 352) were obtained. Half of the specimens were aged (5000 thermal cycles) for each material. Non-aged and aged specimens were divided into 4 groups according to the surface treatments (control, air abrasion, etching, and laser irradiation; n = 11) and processed for scanning electron microscopy (SEM). The repair procedure was performed after the surface treatments. SBS values and failure types were determined. Obtained data were statistically analyzed (P≤.05). RESULTS. The material type, surface treatment type, and their interactions were found significant with regard to SBS (P<.001). Aging also had a significant effect on prosthetic material-resin composite bonding (P<.001). SBS values of non-aged specimens ranged from 12.16 to 17.91 MPa, while SBS values of aged specimens ranged from 9.46 to 15.61 MPa. Non-aged VM in combination with acid etching presented the highest score while the control group of aged CE showed the lowest. CONCLUSION. Etching was more effective in achieving durable SBS for VM and EC. Laser irradiation could be considered as an alternative surface treatment method to air abrasion for all tested materials. Aging had significant effect on SBS values generated between tested materials and resin composite.

매뉴얼 프로그램에 의한 비구면 형상 가공에 관한 연구

  • 박준용;권영균;이동주
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2002.10a
    • /
    • pp.280-285
    • /
    • 2002
  • Copy machines have been used in the 3 dimensional shape machining like the non-sphere surface. This study is intended to show the possibility of manufacturing of a non-sphere shape without a exclusive CAM(Computer Aided Manufacturing) software in the process of metallic mold. It has been examined under the two types of working conditions. One is a cutting by manual programming and the other is a cutting by a general-purpose CAM software. Two kinds of output data were compared and analyzed, and data by a manual program were discovered more accurate than those of a general-purpose CAM software. In this study, I came to a conclusion it is possible to manufacture a 3 dimensional shape without a exclusive CAM software.

  • PDF

A Comparison between Food and Nutrition Major, and Non-major, Female University Students in terms of their Nutrient Intakes and Hematological Status, with an Emphasis on Serum Iron (식품영양 전공 및 비전공 여대생 영양섭취상태 및 혈액성상에 관한 비교 연구 - 혈청 철분을 중심으로 -)

  • 정선희;장경자
    • Journal of Nutrition and Health
    • /
    • v.35 no.9
    • /
    • pp.952-961
    • /
    • 2002
  • The purpose of this study was to compare nutrient intakes and the serum iron status of 74 Food and Nutrition major, and 45 non-major, female students at a university in Incheon. This cross-sectional survey was conducted using a self-administered questionnaire and the data were analyzed by the SPSS 10.0 program. The nutrient intake data collected from three-day dietary recalls were analyzed by the Computer Aided Nutritional Analysis Program. Anthropometric data and hematological indices of iron in the blood were measured. Average heights, weights, body fat and mid-upper arm circumference of Food and Nutrition major and non-major female students were 160.3 cm, 53.5kg, 25.8%, 23.7cm and 159.8cm, 55.5kg, 28.9%, 24.8cm, respectively. There were significant differences in body fat percentage and mid-upper arm circumference between the major and non-major students. In all subjects, daily dietary intakes of nutrients- except protein, vitarrlin B1, vitamin C and phosphorus - were lower than the Korean RDA. In particular, calcium and iron intakes of all subjects were under 60% of the Korean RDA. Values of RBC (red blood cell) count, Hb (hemoglobin), Hct (hematocrit), MCV (mean cell volume), MCH (mean cell hemoglobin), and MCHC (mean corpuscular hemoglobin concentration) of the non-major students were significantly higher compared to those of the major students. The diastolic blood pressure of the major students was negatively correlated with MCV, MCH, TS, and serum iron levels. Triceps skinfold thickness, mid-upper arm circumference and waist-to-hip ratios of the non-major students were negatively correlated with TIBC. Fat intake was positively correlated with RBC, Hb, Hct, and TIBC (total iron binding capacity) in the major students. Vitamin C intake was positively correlated with serum iron in the major students. Carbohydrate intake was positively correlated with Hb, Hct, and MCHC in the non-major students. Niacin and iron intakes were positively correlated with Hb and Hct in the non-major students. Therefore, nutrition education is necessary for female university students to improve nutritional status and to practice optimal nutrition strategies. (Korean J Nutrition 35(9) : 952~961, 2002)

Isogeometric Analysis of Mindlin Plate Structures Using Commercial CAD Codes (상용 CAD와 연계한 후판 구조의 아이소-지오메트릭 해석)

  • Lee, Seung-Wook;Koo, Bon-Yong;Yoon, Min-Ho;Lee, Jae-Ok;Cho, Seon-Ho
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.24 no.3
    • /
    • pp.329-335
    • /
    • 2011
  • The finite element method (FEM) has been used for various fields like mathematics and engineering. However, the FEM has a difficulty in describing the geometric shape exactly due to its property of piecewise linear discretization. Recently, however, a so-called isogeometric analysis method that uses the non-uniform rational B-spline(NURBS) basis function has been developed. The NURBS can be used to describe the geometry exactly and play a role of basis functions for the response analysis. Nevertheless, constructing the NURBS basis functions in analysis is as costly as a meshing process in the FEM. Since the isogeometric method shares geometric data with CAD, it is possible to intactly import the model data from commercial CAD tools. In this paper, we use the Rhinoceros 3D software to create CAD models and export in the form of STEP file. The information of knot vectors and control points in the NURBS is utilized in the isogeometric analysis. Through some numerical examples, the accuracy of isogeometric method is compared with that of FEM. Also, the efficiency of the isogeometric method that includes the CAD and CAE in a unified framework is verified.

Robust Frequency Offset Estimation with a Single Symbol for FH-OFDMA (단일 심볼을 이용한 FH-OFDMA의 주파수 옵셋 추정)

  • Yoon Dae jung;Han Dong seog
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.30 no.4A
    • /
    • pp.250-258
    • /
    • 2005
  • An initial carrier frequency offset estimation algorithm is proposed for a multi-user frequency bowing orthogonal frequency division modulation-frequency division multiple access (FH-OFDMA) system with a single preamble symbol. To mitigate the effect of the frequency offset, every mobile station needs to accurately and rapidly acquire synchronization. The proposed algorithm uses only one preamble symbol in which two kinds of subcarriers are designed for coarse and fine frequency offset estimation. The non-data aided estimation using the energy spectrum is exploited for fine offset estimation, and maximum likelihood estimation using correlation for coarse offset estimation. By combining the two estimation results, an accurate frequency offset can be estimated with a single symbol. Through simulations, the performance of the proposed algorithm is evaluated by comparing estimation error variance with a conventional method.

Evaluation of the reproducibility of various abutments using a blue light model scanner

  • Kim, Dong-Yeon;Lee, Kyung-Eun;Jeon, Jin-Hun;Kim, Ji-Hwan;Kim, Woong-Chul
    • The Journal of Advanced Prosthodontics
    • /
    • v.10 no.4
    • /
    • pp.328-334
    • /
    • 2018
  • PURPOSE. To evaluate the reproducibility of scan-based abutments using a blue light model scanner. MATERIALS AND METHODS. A wax cast abutment die was fabricated, and a silicone impression was prepared using a silicone material. Nine study dies were constructed using the prepared duplicable silicone, and the first was used as a reference. These dies were classified into three groups and scanned using a blue light model scanner. The first three-dimensional (3D) data set was obtained by scanning eight dies separately in the first group. The second 3D data set was acquired when four dies were placed together in the scanner and scanned twice in the second group. Finally, the third 3D data set was obtained when eight dies were placed together in the scanner and scanned once. These data were then used to define the data value using third-dimension software. All the data were then analyzed using the non-parametric Kruskal-Wallis H test (${\alpha}=.05$) and the post-hoc Mann-Whitney U-test with Bonferroni's correction (${\alpha}=.017$). RESULTS. The means and standard deviations of the eight dies together were larger than those of the four dies together and of the individual die. Moreover, significant differences were observed among the three groups (P<.05). CONCLUSION. With larger numbers of abutments scanned together, the scan becomes more inaccurate and loses reproducibility. Therefore, scans of smaller numbers of abutments are recommended to ensure better results.