• Title/Summary/Keyword: non-PVC

Search Result 86, Processing Time 0.027 seconds

Evaluation of Biocompatibility of Extracorporeal Circuit - Development of a Quantification Technique using in-vivo Injection of Tc99m Radioactive Platelets - (체외순환도관의 혈액적합성 평가 - 방사선 동위원소(Tc99m) 활성화 혈소판의 생체 내 주입을 이용한 정량분석법의 개발 -)

  • Lee, Sung-Ho;Sun, Kyung;Choi, Jai-Geol;Son, Ho-Sung;Jung, Jae-Seung;Ahn, Sang-Soo;Oh, Hye-Jung;Lee, Whan-Sung;Lee, Hye-Won;Kim, Kwang-Taik;Jeong, Yoon-Seop;Kim, Young-Ha;Kim, Hyoung-Mook
    • Journal of Chest Surgery
    • /
    • v.35 no.3
    • /
    • pp.171-176
    • /
    • 2002
  • Background: Blood-foreign interaction cause activation of coagulation and inflammatory process that may lead to multiorgan dysfunction and determine the surgical outcomes. Of the methods for assessing the biocompatibility, the platelet adhesion study is considered as the most valuable evaluation step in blood-foreign interaction. As the most studies have used in-vitro or ex-vivo conditions, we have developed a technique of quantification for platelet adhesion on the blood contact surface by using in-vivo injection of radioactive platelets. Material and Method: A coupled bypass circuit was designed to connect the proximal and descending thoracic aorta in 6 piglets(20∼25 Kg). One side of the circuit tube was consisted of a heparin coated PVC tube(10mm in ID, n=6, Experimental group), and the other, a non-heparin coated PVC tube(10mm in ID, n=6, Control group). After cannulation, the blood was circulated through the circuit for 2 hours. Platelet concentrate was prepared from homologous pig blood 24 hours before the experiment. The platelet concentrate was incubated with Tc-99m-HMPAO for 30 min and then centrifuged for 10 min. The supernatant was discarded and the radio-labeling efficacy was measured. The radio-labeled platelet concentrate was mixed with the autologous plasma to make the volume 5 ml, and the mixture was injected intravenously into the experimental animal. After 2 hour circulation, 5 pieces of the specimen(10mm in length each) were obtained from each PVC tube. The radioisotopes were counted with a gamma counter(Cobra ll, Packard, USA), and the ratio of radioisotope count was compared between the control and experimental group. Result: The radioisotope count number was 537.3221.1 Ci/min in the control group and 311.1 184.5 Ci/min in the experimental group(p=0.0104). The ratio between the groups was 1 to 0.58 (p=0.004). Conclusion: In vivo quantification using technetium-99m-HMPAO labeled platelets is simple and reproducible in evaluating platelet adhesion on a foreign surface. We suggest this technique to be a useful tool for blood compatibility test.

Overload Reduction Design and Performance Evaluation for Connection Information Audit in ATM Switch (ATM교환기에서 연결 정보에 대한 감사 기능 수행에 따른 부하 경감 방안 및 성능 평가)

  • 김태희;전병실
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.41 no.10
    • /
    • pp.11-16
    • /
    • 2004
  • This paper proposes the overload reduction method for the connection information audit processor in ATM switch. Based on this method, we design the simple IPC exchange method and non-stop auditing method for IPC loss. We evaluate the performance about the proposed Audit method. At the result of evaluation, we figure out that the p개posed audit method reduces the load of call control processor because of a fewer IPC and prevent stopping audit function for IPC loss because of requesting the lost connection information again. Therefore, we confirm that the proposed audit method can reestablish a Mismatched connection information with a little load and elevate correctness about audit function.

Causes of Wrinkle in Silky Wallpaper and Its Solution

  • Won, Jong-Myoung
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.39 no.5
    • /
    • pp.32-38
    • /
    • 2007
  • The purpose of this study is to investigate the cause of fine wrinkles occurred in silky wallpaper and its solution. The characteristics of base papers, wallpapers and adhesives (conventional and modified) were evaluated to find the possibility for the occurrence of fine wrinkles. It was found that the base papers and wallpapers did not cause the occurrence of silky wallpaper. It was concluded that the fine wrinkles in silky wallpaper was caused by the nonuniform distribution of adhesive, the localized shrinkage of adhesive and the breaking the balance between the resistance of wallpaper and shrinkage of adhesive. Three possible solutions for the prevention of the occurrence of fine wrinkles in silky paper were recommended.

Freshness Keeping of Shiitake Mushroom by Vacuum Cooling (진공예냉에 의한 표고버섯의 선도 연장)

  • Kim, Byeong-Sam;Nahmgung, Bae;Kim, Oui-Woung;Kim, Dong-Chul
    • Korean Journal of Food Science and Technology
    • /
    • v.27 no.6
    • /
    • pp.852-859
    • /
    • 1995
  • Vacuum cooling were carried out for freshness keeping of shiitake mushroom. Shiitake mushroom was cooled within 30 minutes from $20.5^{\circ}C$ to $0.5^{\circ}C$ by vacuum cooling, and then temperature drop of $6.6^{\circ}C$ per weight loss of 1% was taken place during precooling. Weight loss, surface discoloration and softening were reduced by precooling. Judging from organoleptic properties such as cap opening, discoloration, texture and off-flavor, shelf-life of precooled mushroom was lengthed by 20% than that of non-treated mushrooms. Considering effect of packing material on freshness of shiitake mushroom after precooling, weight retention, hardness and organoleptic properties of mushroom packed with PVC wrap were superior to those packed in carton box.

  • PDF

The Improvement on Insulation Performance of Underground Distribution Power Cables (지중배전케이블 절연성능 향상 방안)

  • Lee, Jae-Bong;Lee, Byung-Sung;Kim, Sang-Joon;Jang, Sang-Ok;Han, Yong-Huei;Oh, Jae-Hyoung
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2004.05a
    • /
    • pp.497-501
    • /
    • 2004
  • The primary failure causes of underground distribution power cables are water penetration in insulation layer and stress enhancement at inner semi-conductive layer. Accordingly, it is needed to improve the materials and the structure of power cables for extending lifetime and preventing failure. We uses non-flaming PE materials instead of PVC as a covering material and encapsulating structure. We also use super smooth class material as a inner semi-conductive layer. The newly developed cables are improved in AC breakdown voltage after ageing tests.

  • PDF

A Review on Nanocomposite Based Electrical Insulations

  • Paramane, Ashish S.;Kumar, K. Sathish
    • Transactions on Electrical and Electronic Materials
    • /
    • v.17 no.5
    • /
    • pp.239-251
    • /
    • 2016
  • The potential of nanocomposites have been drawing the intention of the researchers from energy storage to electrical insulation applications. Nanocomposites are known to improve dielectric properties, such as the increase in dielectric breakdown strength, suppressing the partial discharge (PD) as well as space charge, and prolonging the treeing, etc. In this review, different theories have been established to explain the reactions at the interaction zone of polymer matrix and nanofiller; the characterization methods of nanocomposites are also presented. Furthermore, the remarkable findings in the fields of epoxy, cross-linked polyethylene (XLPE), polypropylene and polyvinyl chloride (PVC) nanocomposites are reviewed. In this study, it was observed that there is lack of comparison between results of lab scale specimens and actual field aged cables. Also, non-standardization of the preparation methods and processing parameters lead to changes in the polymer structure and its surface degradation. However, on the positive side, recent attempt of 250 kV XLPE nanocomposite HVDC cables in service may deliver a promising performance in the coming years. Moreover, materials such as self-healing polymer nanocomposites may emerge as substitutes to traditional insulations.

Separation of Mixed Plastics using the Drum type Tribo-Electrostatic Separation Process (드럼형 마찰대전장치를 이용한 혼합플라스틱의 정전선별)

  • Kim Do Kyun;Cho Hee Chan;Jeon Ho Seok
    • Resources Recycling
    • /
    • v.13 no.1
    • /
    • pp.39-46
    • /
    • 2004
  • Triboelectrostatic separation process is a technology that different particles charged after contact and rubbing different materials are separated in a high electric field. This technology has an advantage in that it can be used for separating non-conducting materials such as plastics unlike other electrostatic separation processes. There are two objectives in this study. One is to develop an effective continuous tribo-electrostatic separation process. The other is to apply the developed device for the separation of mixed plastics. Results show that almost all tested plastics reaches over 95% in yield and grade after separation.

Late Fall Nitrogen Application and Turf Cover for Zoysiagrass (Zoysia japonica) Spring Green-up

  • Oh, Jun-Suk;Lee, Yu-Jin;Lee, Sang-Kook
    • Weed & Turfgrass Science
    • /
    • v.4 no.4
    • /
    • pp.383-389
    • /
    • 2015
  • The use of zoysiagrass (Zoysia japonica Steud.) in the transition zone is limited because of a lack of cold hardiness although zoysiagrass has many advantages compared to other warm-season and cool-season grasses. Late-fall N fertilization is often applied for darker green color of turfgrass in early spring and more extensive root growth without rapid top growth. The objective of the study was to evaluate the effects of late fall N application and turf cover for zoysiagrass spring green-up. Clear polyvinyl chloride (PVC) film was used for turf cover. The amount of N applied were 5 and $10g\;N\;m^{-2}$ for the low and high N rate treatments, respectively. Covered zoysiagrass had greater turfgrass color and quality in early spring than non-covered zoysiagrass. The high N rate had 0.6 to 2.3 greater turfgrass quality than the low N rate on 7 of 9 rating dates. Slow-release N as late fall fertilization is more effective for turfgrass color and quality than fast-release N in spring. Turf cover could reduce the period of yellow zoysiagrass, and the earlier time of spring green-up could be advanced by increasing turfgrass quality and growth of zoysiagrass.

A Novel Iron(III) Selective Membrane Electrode Containing a Tripodal Polycatacholamine as Sensor

  • Bera, Rati Kanta;Sahoo, Suban K;Baral, Minati;Kanungo, B.K.
    • Bulletin of the Korean Chemical Society
    • /
    • v.32 no.10
    • /
    • pp.3592-3596
    • /
    • 2011
  • A novel poly(vinylchloride)-based membrane sensor using $N^1$,$N^3$,$N^5$-tris(2-(2,3-dihydroxybenzylamino)-ethyl)cyclohexane-1,3,5-tricarboxamide (CYCOENCAT, L) as ionophore has been prepared and explored as $Fe^{3+}$ selective electrode. The membrane electrode composed of ionophore, poly(vinylchloride) and o-nitropheyloctyl ether in the optimum ratio 4:33:63 gave excellent potentiometric response characteristics, and displayed a linear log[$Fe^{3+}$] versus EMF response over a wide concentration range of $1.0{\times}10^{-5}-1.0{\times}10^{-1}$ M with super nernstian slope of 28.0 mV/decade and the detection limit of $8.0{\times}10^{-6}$ M. The proposed ion selective electrode showed fast response time (< 15 s), wide pH range (3.0-7.0), high non-aqueous tolerance (up to 20%) and adequate long life time (120 days). It also exhibited very good selectivity for $Fe^{3+}$ relative to a wide variety of alkali, alkaline earth, transition and heavy metal ions. Further, the analytical applicability of the sensor was tested as an indicator electrode in the potentiometric titration of $Fe^{3+}$ with EDTA.

Air-coupled ultrasonic tomography of solids: 2 Application to concrete elements

  • Hall, Kerry S.;Popovics, John S.
    • Smart Structures and Systems
    • /
    • v.17 no.1
    • /
    • pp.31-43
    • /
    • 2016
  • Applications of ultrasonic tomography to concrete structures have been reported for many years. However, practical and effective application of this tool for nondestructive assessment of internal concrete condition is hampered by time consuming transducer coupling that limits the amount of ultrasonic data that can be collected. This research aims to deploy recent developments in air-coupled ultrasonic measurements of solids, described in Part 1 of this paper set, to concrete in order to image internal inclusions. Ultrasonic signals are collected from concrete samples using a fully air-coupled (contactless) test configuration. These air coupled data are compared to those collected using partial semi-contact and full-contact test configurations. Two samples are considered: a 150 mm diameter cylinder with an internal circular void and a prism with $300mm{\times}300mm$ square cross-section that contains internal damaged regions and embedded reinforcement. The heterogeneous nature of concrete material structure complicates the application and interpretation of ultrasonic measurements and imaging. Volumetric inclusions within the concrete specimens are identified in the constructed velocity tomograms, but wave scattering at internal interfaces of the concrete disrupts the images. This disruption reduces defect detection accuracy as compared with tomograms built up of data collected from homogeneous solid samples (PVC) that are described in Part 1 of this paper set. Semi-contact measurements provide some improvement in accuracy through higher signal-to-noise ratio while still allowing for reasonably rapid data collection.