• 제목/요약/키워드: noise in image data

검색결과 747건 처리시간 0.036초

Modified Gaussian Filter based on Fuzzy Membership Function for AWGN Removal in Digital Images

  • Cheon, Bong-Won;Kim, Nam-Ho
    • Journal of information and communication convergence engineering
    • /
    • 제19권1호
    • /
    • pp.54-60
    • /
    • 2021
  • Various digital devices were supplied throughout the Fourth Industrial Revolution. Accordingly, the importance of data processing has increased. Data processing significantly affects equipment reliability. Thus, the importance of data processing has increased, and various studies have been conducted on this topic. This study proposes a modified Gaussian filter algorithm based on a fuzzy membership function. The proposed algorithm calculates the Gaussian filter weight considering the standard deviation of the filtering mask and computes an estimate according to the fuzzy membership function. The final output is calculated by adding or subtracting the Gaussian filter output and estimate. To evaluate the proposed algorithm, simulations were conducted using existing additive white Gaussian noise removal algorithms. The proposed algorithm was then analyzed by comparing the peak signal-to-noise ratio and differential image. The simulation results show that the proposed algorithm has superior noise reduction performance and improved performance compared to the existing method.

AWGN 환경에서 잡음 특성을 고려한 변형된 가우시안 필터 (Modified Gaussian Filter Considering Noise Characteristics in AWGN Environments)

  • 천봉원;김남호
    • 융합신호처리학회논문지
    • /
    • 제20권3호
    • /
    • pp.125-131
    • /
    • 2019
  • 4차 산업혁명을 통해 다양한 디지털 장비가 보급되고 있으며, 이에 따라 데이터 처리의 중요성이 높아지고 있다. 데이터 처리는 장비의 신뢰성에 큰 영향을 미치는 만큼 그 중요성이 증가하고 있으며, 다양한 연구가 진행되고 있다. 본 논문에서는 영상에 존재하는 잡음의 특성을 고려하여 AWGN을 제거하기 위한 알고리즘을 제안하였다. 제안한 알고리즘은 영상의 잡음 표준편차를 유추하여 필터링 과정에 사용하였으며, 필터링 마스크의 표준편차와 비교해 고주파 성분에 대한 필터와 저주파 성분에 대한 필터를 구분하여 잡음을 제거하였다. 제안하는 알고리즘을 평가를 위해 기존 방법들과 시뮬레이션하였으며, 차영상 및 PSNR과 프로파일을 통해 비교 분석하였다. 제안한 알고리즘은 잡음의 영향을 최소화하였으며, 영상의 중요 특성을 보존하며 효율적으로 잡음을 제거하는 성능을 보였다.

선형모형과 표준편차에 기반한 잡음영상에 효과적인 에지 검출 방법 (An effective edge detection method for noise images based on linear model and standard deviation)

  • 박영호
    • 응용통계연구
    • /
    • 제33권6호
    • /
    • pp.813-821
    • /
    • 2020
  • 최근 다양한 분야에서 사진, 동영상 등과 같이 비정형 데이터를 이용한 연구가 활발하게 진행되고 있다. 이 중에서도 영상을 활용하는 연구들은 영상에 포함된 정보를 사용하기 위하여 많은 영상처리 기법들을 사용하고 있다. 에지 검출은 영상에서 정보를 추출하기 위해 많은 영상처리 응용 프로그램에서 사용되는 기본 도구이다. 그러나 잡음이 포함된 영상은 에지와 잡음이 모두 고주파 성분을 가지고 있기 때문에 에지 검출을 수행하는 것은 매우 어렵다. 본 논문은 잡음이 감소된 에지를 추출하는 방법으로 선형모형과 표준편차를 이용하였다. 화소 블록에 포함된 화소들의 표준편차와 선형모형의 적합으로 얻어진 잔차에 대한 표준편차의 차이로 에지를 검출하였다. 에지 검출의 결과는 영상처리 분야에서 대표적으로 사용되는 소벨 에지 검출기의 결과와 비교하였다. 잡음이 포함되지 않은 영상은 소벨 에지 검출 결과와 제안한 에지 검출의 결과가 유사하게 나타나고, 제안한 방법이 다양한 수준의 잡음이 추가된 영상에서 잡음에 의한 에지가 적게 나타나는 것을 확인하였다.

Point-Jacobian 반복 MAP 추정을 이용한 고해상도 영상복원 (Image Restoration of Remote Sensing High Resolution Imagery Using Point-Jacobian Iterative MAP Estimation)

  • 이상훈
    • 대한원격탐사학회지
    • /
    • 제30권6호
    • /
    • pp.817-827
    • /
    • 2014
  • 위성 원격 탐사에서는 센서 운영 환경으로 인하여 영상을 수집하는 동안 영상의 질 저하가 일어나며 이러한 영상의 질 저하는 관측된 자료로부터 유용한 정보를 확인하거나 추출하는 데 악 영향을 미치는 번짐 현상(blurring)과 잡음 (noise)을 야기시킨다. 본 연구는 원격 탐사 영상 자료의 질 저하 현상을 모형화하기 위해 Gaussian 가산 잡음과 Markov random field로 정의되는 공간적 연결성을 가정하였다. 그리고 질 저하된 관측 자료로부터 원래 강도의 영상을 복원하기 위한 Point-Jacobian 반복 maximum a posteriori (MAP) 추정 법을 제안한다. 제안 연구는 이웃 창의 형태로 8 개 방향의 창으로 구성된 방사형을 사용하며 각 방향에서의 중심 화소와의 이웃 화소들 간의 Mahalanobis 제곱 거리를 경계 근접성 측정치로 사용한다. 제안 방법의 성능을 평가하기 위해서 고해상도 영상 자료에 나타날 수 있는 다양한 형태의 패턴을 사용하는 simulation 자료를 생성하여 화소 단위 분류 법을 사용하여 정량적 평가를 수행하였고 한반도 안양 북부 지역에서 관측된 1 m 급 IKONOS 자료의 무감독 분할을 통해 정성적 평가를 수행하였다. 실험 결과는 고해상도 원격 탐사 자료 분석에서 제안 영상 복원 법을 적용하면 현저히 분석의 정확성을 높이는 것을 보여 준다.

선형 보간법 및 공간 가중치를 이용한 Salt and Pepper 잡음 제거 (Salt and Pepper Noise Removal using Linear Interpolation and Spatial Weight value)

  • 권세익;김남호
    • 한국정보통신학회논문지
    • /
    • 제20권7호
    • /
    • pp.1383-1388
    • /
    • 2016
  • 영상 신호처리는 다양한 분야에서 활용되고 있으며, 영상 데이터는 전송 과정에서 여러 가지 원인으로 열화가 발생된다. 일반적으로 salt and pepper 잡음 환경에 의해 훼손된 영상의 잡음을 제거하는 대표적인 방법에는 CWMF, A-TMF, AWMF 등이 있으며 이 필터들은 고밀도 잡음 환경에서 잡음제거 특성이 다소 부족하다. 따라서 본 논문에서는 중심화소가 비잡음인 경우 원 화소로 대치하고, 잡음인 경우 국부 마스크를 네 방향으로 세분화하여 선형 보간법을 이용하여 원 화소를 추정하고 추정된 화소에 공간 가중치를 적용하여 처리하는 알고리즘을 제안하였다. 제안한 알고리즘은 salt and pepper 잡음(P = 50%)에 훼손된 House 영상에서 26.86[dB]의 높은 PSNR을 보이고 있고, 기존의 CWMF, A-TMF, AWMF에 비해 각각 16.46[dB], 12.28[dB], 12.32[dB] 개선되었다.

경사조사(傾斜照射) 강판튜브 방사선 관측영상의 수직 방향 공간분석 (Vertical Space Analysis for Gradient Radiating Steel-tube Radiographic Image)

  • 황중원;황재호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 심포지엄 논문집 정보 및 제어부문
    • /
    • pp.29-31
    • /
    • 2007
  • In this paper we propose an directional analytic approach in image data space for X-ray image which is detected from the X-ray projection system. Such a radiographic nondestructive testing has long been used for steel-tube inspection and weld monitoring. The welded area and thickness of steel-tube are detected from gradient radiating mechanism based on the evaluation of biased X-ray source position. The welded area is an ellipse type on low contrast X-ray image including noise. Noise originates from most of elements of the system. such as shielding CCD camera, imaging screen, X-ray source, inspected object, electronic circuits and etc.. Projection incorrectness and noise influence on imaging quality is to be represented by vertical pixels' distribution. Space analysis due to vertical direction also shows the segmental possibility between regions by visual edge evaluation.

  • PDF

Frequency Filter를 사용한 MRI 영상 화질의 향상 (Improving Image Quality of MRI using Frequency Filter)

  • 김동현
    • 한국콘텐츠학회논문지
    • /
    • 제9권11호
    • /
    • pp.309-315
    • /
    • 2009
  • MRI로부터 얻어지는 영상신호는 주파수 영역 데이터에 주파수 필터를 적용한 후 이를 역 퓨리에 변환하여 영상을 재구성하는 방법을 적용하고 있다. 의료 영상들을 임상에서 효율적으로 활용할 수 있도록 하기 위해 다양한 영상처리 기법들이 사용되고 있다. 즉 영상 진단 장비로 획득한 영상을 전처리과정(Preprocessing)을 수행하는 영상처리 기법과 이차원 영상을 삼차원으로 나타내는 영상 재구성 방법, 영상을 효율적으로 저장하고 전송하기 위한 영상 압축 기법과 복원 기법 등이 있다. 그리고 다양한 영상기기들로부터 획득한 영상을 조합하여 진단에 활용하는 기법, 영상기기 또는 주위 환경으로부터 발생한 로이즈 및 이물질의 제거, 영상의 신호강도와 신호대잡음비 (SNR, Signal to Noise Ratio)를 증가시키고 대조도를 향상시켜 영상의 화질을 개선하는 기법 등이 있다. 본 논문에서는 MRI로부터 획득한 k-space 데이터의 주파수 및 위상 성분을 변화시킬 수 있는 필터들을 설계한 후 각각의 특성을 비교 분석하여 임상에서 질환의 진단에 적용 가능한 최적의 필터, 즉 변형된 Fermi-Dirac 필터를 고안하였고 이 필터는 기존 MR 영상보다 영상의 화질을 개선시키는 것을 알 수 있었다.

Invariant Range Image Multi-Pose Face Recognition Using Fuzzy c-Means

  • Phokharatkul, Pisit;Pansang, Seri
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2005년도 ICCAS
    • /
    • pp.1244-1248
    • /
    • 2005
  • In this paper, we propose fuzzy c-means (FCM) to solve recognition errors in invariant range image, multi-pose face recognition. Scale, center and pose error problems were solved using geometric transformation. Range image face data was digitized into range image data by using the laser range finder that does not depend on the ambient light source. Then, the digitized range image face data is used as a model to generate multi-pose data. Each pose data size was reduced by linear reduction into the database. The reduced range image face data was transformed to the gradient face model for facial feature image extraction and also for matching using the fuzzy membership adjusted by fuzzy c-means. The proposed method was tested using facial range images from 40 people with normal facial expressions. The output of the detection and recognition system has to be accurate to about 93 percent. Simultaneously, the system must be robust enough to overcome typical image-acquisition problems such as noise, vertical rotated face and range resolution.

  • PDF

영상처리를 통한 케이블의 진동 계측 (Vibration Measurement of Cable by Image Processing Technique)

  • 곽문규;신지환;구재량;배용채
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2014년도 추계학술대회 논문집
    • /
    • pp.303-305
    • /
    • 2014
  • This paper is concerned with the vibration measurement of cable by image processing technique. The measurement system consists of a CCD camera and zoom lens. The image data can be transferred to PC via USB or IEEE1394 port. In this study, a Matlab program was made to process the acquired image data. After acquiring an image data for each frame, this data is binarized for tracing cable vibrations. Then the area occupied by the cable is marked by 1 and the background is covered by 0. In this way, we can calculate the displacement of the cable. Experimental results show that the tracing of cable displacements is possible and natural frequencies and mode shapes can be computed. The accuracy of the image processing system for vibration measurement depends on the maximum frame rate of the CCD camera. The use of a high-speed camera enables us to compute more higher modes. The laboratory experiments guarantee the vibration measurement of real transmission lines.

  • PDF

고밀도 임펄스 잡음에 훼손된 영상 복원을 위한 적응형 가중치 필터 알고리즘 (Adaptive Weight Filter Algorithm for Restoration Images Corrupted by High Density Impulse Noise)

  • 천봉원;김남호
    • 한국정보통신학회논문지
    • /
    • 제26권10호
    • /
    • pp.1483-1489
    • /
    • 2022
  • 최근 4차 산업혁명의 영향과 통신매체의 발전으로 다양한 디지털 영상장비가 산업현장에서 사용되고 있다. 영상 데이터는 카메라와 센서로부터 취득되는 과정 및 송수신 과정에서 잡음에 훼손되기 쉬우며, 훼손된 영상은 시스템의 처리과정에 영향을 미치기 때문에 잡음제거가 필수적으로 선행되고 있다. 본 논문에서는 고밀도의 임펄스 잡음에 훼손된 영상을 복원하기 위해 가중치 그래프를 사용한 가중치 필터 알고리즘을 제안하였다. 제안한 알고리즘은 영상의 필터링 마스크 내부의 화소값을 사용하여 가중치 그래프를 구하였으며, 최종 가중치를 필터링 마스크에 적용하여 영상을 복원하였다. 제안하는 알고리즘의 잡음제거 성능을 분석하기 위해 시뮬레이션을 진행하였으며, 확대영상 및 PSNR을 사용하여 기존 방법과 비교하였다. 제안한 알고리즘의 결과 영상은 고밀도 임펄스 잡음을 제거하며 우수한 성능을 보였다.