• 제목/요약/키워드: no-load power

검색결과 516건 처리시간 0.021초

펄스형 부하에서 ZVS Full-bridge PWM 컨버터의 효율 증대를 위한 제어 방법 (Efficient Control Method of ZVS Full-bridge PWM Converter with Pulse Load Current)

  • 김정원
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2000년도 전력전자학술대회 논문집
    • /
    • pp.404-408
    • /
    • 2000
  • The novel control method of ZVS Full-bridge PWM converter with pulse load current is proposed. This new control method can reduce the switching loss of switches during no load condition. Moreover by using feed-forward load current information this method can obtain better transient dynamics compared to the system with only linear feedback control.

  • PDF

Analysis and Implementation of a New ZVS DC Converter for Medium Power Application

  • Lin, Bor-Ren;Shiau, Tung-Yuan
    • Journal of Electrical Engineering and Technology
    • /
    • 제9권4호
    • /
    • pp.1296-1308
    • /
    • 2014
  • This paper presents a new zero voltage switching (ZVS) converter for medium power and high input voltage applications. Three three-level pulse-width modulation (PWM) circuits with the same power switches are adopted to clamp the voltage stress of MOSFETs at $V_{in}/2$ and to achieve load current sharing. Thus, the current stresses and power ratings of transformers and power semiconductors at the secondary side are reduced. The resonant inductance and resonant capacitance are resonant at the transition interval such that active switches are turned on at ZVS within a wide range of input voltage and load condition. The series-connected transformers are adopted in each three-level circuit. Each transformer can work as an inductor to smooth the output current or a transformer to achieve the electric isolation and power transfer. Thus, no output inductor is needed at the secondary side. Three center-tapped rectifiers connected in parallel are used at the secondary side to achieve load current sharing. Compared with the conventional parallel three-level converters, the proposed converter has less switch counts. Finally, experiments based on a 1.44kW prototype are provided to verify the operation principle of proposed converter.

전자식 강압형 트랜스포머 (Electronic Step-down Transformer)

  • 서재현;김만고
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2005년도 전력전자학술대회 논문집
    • /
    • pp.74-77
    • /
    • 2005
  • An electronic step-down transformer is proposed. Conventional iron cored transformer is heavy and bulky and it has substantial amount of no load loss. On the other hand, electronic transformer can provide negligible no load loss, small size, and light weight. It consists of rectifier and PWM inverter. The output voltage is controlled by duty ratio. To confirm the validity of the proposed transform, simulation and experimental results are presented.

  • PDF

Losses in Power Distribution Transformers

  • Ketkaew, Chaliew;Philphud, Mana;Sungthong, Tossapol;Rachawong, Wiriya;Kalong, Putchong;Noohawm, Onurai;Rerkpreedapong, Dulpichet
    • International Journal of Advanced Culture Technology
    • /
    • 제3권2호
    • /
    • pp.144-148
    • /
    • 2015
  • The paper presents the estimation of power losses in distribution transformer of Provincial Electricity Authority (PEA) distribution system at Muang district of Suphanburi province in Thailand. Data of 416 power distribution transformers composed of transformer (kVA), load current, no load loss and full load loss which were used for calculating energy losses. It was found that the total energy loss of all transformers is approximately 1,756,380 kWh/year.

Full ZVS Load Range Diode Clamped Three-level DC-DC Converter with Secondary Modulation

  • Shi, Yong
    • Journal of Power Electronics
    • /
    • 제16권1호
    • /
    • pp.93-101
    • /
    • 2016
  • A new four-primary-switch diode clamped soft switching three-level DC-DC converter (TLDC) with full zero-voltage switching (ZVS) load range and TL secondary voltage waveform is proposed. The operation principle and characteristics of the presented converter are discussed, and experimental results are consistent with theoretical predictions. The improvements of the proposed converter include a simple and compact primary structure, TL secondary rectified voltage waveform, wide load range ZVS for all primary switches, and full output-regulated range with soft switching operation. The proposed converter also has some disadvantages. The VA rating of the transformer is slightly larger than that of conventional TLDCs in variable input and constant output mode. The conduction loss of the primary coil is slightly higher because an air gap is inserted into the magnetic cores of the transformer. Finally, the secondary circuit is slightly complex.

Investigation of Low-Frequency Characteristics of Four-Switch Three-Phase Inverter

  • Yuan, Qingwei;Cheng, Chong;Zhao, Rongxiang
    • Journal of Electrical Engineering and Technology
    • /
    • 제12권4호
    • /
    • pp.1471-1483
    • /
    • 2017
  • The low-frequency characteristics of four-switch three-phase (FSTP) inverter are investigated in this paper. Firstly, a general space vector pulse width modulation (SVPWM) directly involved the neutral point voltage of DC-link is proposed, where no sector identifications and trigonometric function calculations are needed. Subsequently, to suppress the DC offset in the neutral point voltage, the relationship between the neutral point voltage and the ${\beta}-axis$ component of the load current is derived, and then a new neutral point voltage control scheme is proposed where no low pass filter is adopted. Finally, the relationship between the load power factor and the maximum linear modulation index of the FSTP inverter is revealed. Since the operational region for the FSTP inverter in low frequency is reduced by the enlarged amplitude of the neutral point voltage, a linear modulation range enlargement scheme is proposed. A permanent magnet synchronous motor with preset rotary speed serves as the low-frequency load of the FSTP inverter. Experimental results verify that the new neutral point voltage control scheme is effective in the deviation suppression of the neutral point voltage, and the proposed scheme is able to provide a larger linear operational region in low frequency.

DME/천연가스 HCCI 기관의 연소특성(기통 간 불균형과 EGR의 영향) (Combustion Characteristics of HCCI Engine Fueled DME and Natural Gas(Unbalance of Cylinder-to-Cylinder and Effect of EGR))

  • 정석호
    • 동력기계공학회지
    • /
    • 제14권3호
    • /
    • pp.13-18
    • /
    • 2010
  • HCCI engines fueled DME and natural gas have been studied on single-cylinder engine due to availability of reducing on $NO_X$ and PM simultaneously without deteriorating into high thermal efficiency, and thus it is clarified that higher maximum engine load is achieved as DME equivalence is smaller. In this study, combustion tests were accomplished on multi-cylinder engine for practical use of it. When minimum DME equivalence achieved maximum engine load on single-cylinder engine was applied to 4-cylinders engine, there was in unstable running condition that engine revolution fluctuated greatly and cyclically. It is the reason what misfire occurred intermittently with one the same as minimum DME equivalence on single-cylinder due to increase in energy for ignition at No. 1 cylinder with lower cylinder liner temperature. Maximum engine load was achieved by adopting EGR, though it decreased because of knocking at smaller engine load than single-cylinder due to increase in minimum DME equivalence.

바인더 볏단의 크기가 자동탈곡기(自動脱糓機)의 탈곡성능(脱糓性能) 및 부하특성(負荷特性)에 미치는 영향(影響) (Effects of Binder-Sheaf Size on Threshing Performance and Load Characteristics of an Auto Feed Thresher)

  • 유수남;류관희
    • Journal of Biosystems Engineering
    • /
    • 제6권1호
    • /
    • pp.60-72
    • /
    • 1981
  • This study was carried out to find out the effects of the sheaf size of paddy harvested by the binders on the threshing performance, load characteristics and power requirement of an auto-feed thresher. The results of the study are summarized as follows: 1. The seperating performance of the thresher appeared to be satisfactory for all the sheaf sizes although the amount of rubbishes and empty grains slightly increased with the sheaf size of paddy. 2. There was no significant difference in grain output quality of the thresher among the three sheaf sizes. However, the amount of grains left unthreshed increased with the sheaf size. In the case of the largest sheaf size with the feed rate of 780kg/h, it exceeded the limit set by the national inspection regulations. 3. The position of the feed-chain rail gave a significant effect on the power requirement of the thresher. At the feed rate of 780kg/h, the net power required to convey sheafs through the feed chain was in the range of 0.37 to 0.50 PS for the middle and lowest position of feed-chain rail, and there was no significant difference among the sheaf sizes. At the highest position, however, it appeared that the smallest sheaf required more power than the others. The net power requirements at this position were 1.03, 0.59. 0.65 PS for the smallest, medium and largest sheafs respectively. 4. The torques of both the thresher and the engine shaft increased with the feed rate and were not affected by the sheaf size for the lower two feed rates of 520 and 780kg/h. At the highest feed rate of 1,040 kg/h, however, they were affected by the sheaf size. In this case, the medium sheaf size gave lower values than the others. 5. The variations in the thresher and the engine torque increased with the feed rate and were not affected by the sheaf size for the feed rate of 520kg/h. At the feed rate of 780kg/h, however, they increased with sheaf size. And at the feed rate of 1,040 kg/h, the torque variations increased greatly for all the sheaf sizes due to an over-load operating condition. 6. It appeared that the average and maximum power requirements of the thresher increased with the feed rate. But, there was no significant difference in power requirement among the sheaf sizes for the lower two feed rates. 7. The threshing efficiency of the thresher was in the range of 214-249 kg/ps.h with the feed rates of 520 and 780 kg/h, and it was not affected by both the sheaf size and the feed rate. At the feed rate of 1,040 kg/h, however, it decreased to as low as 171-174 kg/ps.h because of a sudden increase in power requirement. 8. The average power requirements of the engine were slightly higher than those of the thresher due to the slippage of flat belt between the thresher and engine. It appeared that power transmission from the engine to the thresher was maintained properly since slippages were moderately low with the range of 2.78 to 6.51% throughout the tests. 9. The specific fuel consumption of the engine (diesel 8PS) decreased as the feed rate increased. However, there was no significant reduction in specific fuel consumption as the feed rate increased above 780 kg/h.

  • PDF

A New Approach for Corrective and Preventive Control to Unsolvable Case in Power Networks having DERs

  • Dinh, Hung Nguyen;Nguyen, Minh Y.;Yoon, Yong Tae
    • Journal of Electrical Engineering and Technology
    • /
    • 제8권3호
    • /
    • pp.411-420
    • /
    • 2013
  • Recently, Korean system operating conditions have gradually approached an upper limit. When a contingency occurs, the power system may have no solutions. Different from the cases of bad initial guesses or the solutions are too close to the solvability boundary in which numerical methods can be applied, for unsolvable cases, the only way to restore solvability would be structure modifications. In this paper, a new approach for corrective and preventive control to such cases is proposed in two steps: (i) finding any solution regardless its feasibility; (ii) for the infeasible solution, make it feasible with additional modifications at load buses having Distributed Energy Resources. The test case built based on the peak load profile of 2008 by KEPCO including 1336 buses is analyzed. Since reactive power compensation is optimized to restore solvability, all demands are met, therefore no blackouts happen. The proposed method was integrated in the LP program designed by power21 Corporation.

펄스모드 스위칭 직류전원 장치에 적합한 AC/DC 컨버터 (AC/DC Converter Suitable for a Pulsed Mode Switching DC Power Supply)

  • 문상호;강성관;노의철;김인동;김흥근;전태원
    • 전력전자학회논문지
    • /
    • 제8권5호
    • /
    • pp.389-396
    • /
    • 2003
  • 직류진원 장치의 부하에 단락이 발생하는 경우 직류전원을 부하로부터 신속히 차단하고 재인가 가능한 새로운 방식의 ac/dc 컨버터를 제안하였다. 제안한 방식의 컨버터 출력전윈은 부하단락시 차단 및 정상상태로 회복시 직류전원을 재인가하여 정격출력전압으로 확립되는데 소요되는 시간이 각각 수백 $\mu\textrm{s}$ 이내에 이루어지는 특징이 있다. 또한 컨버터 출력필터 커패시터는 부하가 단락된 상태에서도 방전하지 않고 거의 정격출력전압을 유지할 수 있으므로 직류전원을 단락상태가 소멸된 정상부하에 재인가시 전압의 오버슈트 없이 신속한 부하전압 확립이 가능하다. 제안한 방식의 컨버터는 기존 방식에 비해 구조가 간단하고 소형경량화 가능한 장점이 있다. 제안한 회로방식에 대한 동작원리 설명 및 특성해석을 하였으며 실험을 통하여 그 유용성을 입증하였다.