• Title/Summary/Keyword: no-cement

Search Result 895, Processing Time 0.028 seconds

Bonding efficacy of cured or uncured dentin adhesives in indirect resin (간접 레진수복시 상아질 접착제의 중합 여부에 따른 결합 효능)

  • Jang, Ji-Hyun;Lee, Bin-Na;Chang, Hoon-Sang;Hwang, Yun-Chan;Oh, Won-Mann;Hwang, In-Nam
    • Restorative Dentistry and Endodontics
    • /
    • v.36 no.6
    • /
    • pp.490-497
    • /
    • 2011
  • Objectives: This study examined the effect of the uncured dentin adhesives on the bond interface between the resin inlay and dentin. Materials and Methods: Dentin surface was exposed in 24 extracted human molars and the teeth were assigned to indirect and direct resin restoration group. For indirect resin groups, exposed dentin surfaces were temporized with provisional resin. The provisional restoration was removed after 1 wk and the teeth were divided further into 4 groups which used dentin adhesives (OptiBond FL, Kerr; One-Step, Bisco) with or without light-curing, respectively (Group OB-C, OB-NC, OS-C and OS-NC). Pre-fabricated resin blocks were cemented on the entire surfaces with resin cement. For the direct resin restoration groups, the dentin surfaces were treated with dentin adhesives (Group OB-D and OS-D), followed by restoring composite resin. After 24 hr, the teeth were assigned to microtensile bond strength (${\mu}TBS$) and confocal laser scanning microscopy (CLSM), respectively. Results: The indirect resin restoration groups showed a lower ${\mu}TBS$ than the direct resin restoration groups. The ${\mu}TBS$ values of the light cured dentin adhesive groups were higher than those of the uncured dentin adhesive groups (p < 0.05). CLSM analysis of the light cured dentin adhesive groups revealed definite and homogenous hybrid layers. However, the uncured dentin adhesive groups showed uncertain or even no hybrid layer. Conclusions: Light-curing of the dentin adhesive prior to the application of the cementing material in luting a resin inlay to dentin resulted in definite, homogenous hybrid layer formation, which may improve the bond strength.

Clinical evaluation of the removable partial dentures with implant fixed prostheses (임플란트 고정성 보철물을 이용한 가철성 국소의치의 합병증에 관한 임상적 평가)

  • Kang, Soo-Hyun;Kim, Seong-Kyun;Heo, Seong-Joo;Koak, Jai-Young;Lee, Joo-Hee;Park, Ji-Man
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.54 no.3
    • /
    • pp.239-245
    • /
    • 2016
  • Purpose: The purpose of this study was to identify clinical complications in removable partial denture (RPD) with implant-supported surveyed prostheses, and to analyze the factors associated with the complications such as location of the implant, splinting adjacent prostheses, the type of retentive clasps, Kennedy classification, and opposing dentition. Materials and Methods: A retrospective clinical study was carried out for 11 patients (7 male, 4 female), mean age of 67.5, who received RPD with Implant-supported surveyed prostheses between 2000 and 2016. The mechanical complications of 11 RPDs and 37 supporting implant prostheses and the state of natural teeth and peripheral soft tissue were examined. Then the factors associated with the complications were analyzed. Results: The average of 3.4 implant-supported prostheses were used for each RPD. Complications found during the follow-up period of an average of 42.1 months were in order of dislodgement of temporary cement-retained prostheses, opposing tooth fracture/mobility, screw fracture/loosening, clasp loosening, veneer porcelain fracture, marginal bone resorption and mobility of implant, artificial tooth fracture. Complications occurred more frequently in anterior region compared to posterior region, non-splinted prostheses compared to splinted prostheses, surveyed prostheses applied by wrought wire clasp compared to other clasps, and natural dentition compared to other removable prostheses as opposing dentition. There were no significant differences in complications according to the Kennedy classification. Conclusion: All implant-assisted RPD functioned successfully throughout the follow-up. However, further clinical studies are necessary because the clinical evidences are still not enough to guarantee the satisfactory prognosis of implant-assisted RPD for long-term result.

Studies on the Durability of Mortars (모르타르의 내구성에 관한 연구)

  • 고재군
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.11 no.4
    • /
    • pp.1798-1802
    • /
    • 1969
  • The experiment was carried out as one of the basic studies to improve the alkali-resistance of cement mortars and it was conducted to investigate some propetties of mortars relating to weight losses when exposed to 0.1 N salution of sodium hydroxide. The experiment and the results obtained are summarized as follow; 1. The specimens used in this experiment were made of 5 centi-meter cubes of mortar having such various ratios of mix by weight as 1 : 1, 1 : 3, 1 : 5, 1 : 7 and 1 : 10. 2. Physical tests included compressive strengths at 7 days, 28 days, 3 months, and 6 month, and 5 hour boiling absorption test. 3. In alkali test, every specimen was immersed into 0.1 N solutions of sodium hydroxide. The specimens exposed to the alkali solution were weighed to determine the weight losses of the alkail-corroded at one week interval for 7 week's exposure and the old alkali solutions were also changed to fresh solutions when weighed the weight losses by alkali attack at one week interval. 4. According to the alkail test after 7 week's exposure, no weight losses were observed on ratios of mix 1:1 and 1:3 and slight weight losses occurred on ratios of mix 1:5 and 1:7, but relatively large amount of weight losses were showed by 36.6 per-cent on ratios of mix 1:10. It was also found that the weight losses of the alkali-corroded were extremely lower than those of the acid-corroded at the some concentrations as 0.1 N of solutions. 5. In order to make better quality of alkali-resistant mortar it might recomend that a 1:7 mix or richemixes, use of small amount of mixing water for watertight, 20 per cent or less absorption by 5 hour boiling 1,600 kirogram per cubic meters or denser densities by absolute dry base are available for physical properties of mortar. It could conclude acid-resistant mortars were so high alkali-resistant, that it is expected to make and improve the acid-resistant mortars for getting rid of damages by alkali attack.

  • PDF

Geochemistry of tourmalines in the Ilgwang Cu-W breccia-pipe deposit, Southeastern Gyeongsang Basin (경상남도 일광의 각력파이프형 구리(Cu)광상에서 산출되는 전기석의 지구화학)

  • 양경희;장주연
    • The Journal of the Petrological Society of Korea
    • /
    • v.11 no.3_4
    • /
    • pp.259-270
    • /
    • 2002
  • A small granodiorite-quartz monzonitic stock containing sericitic and propylitic alteration assemblages hosts a Cu-W breccia-pipe deposit in the southeastern Cyeongsang basin. The mineralized breccia-pipe contains angular to subangular brecciated fragments of granitic rocks showing clast-supported textures. An assemblage of quartz, tourmalines, sulfide minerals (mainly chalcopyrite, arsenopyrite and pyrrhotite) and calcite was precipitated as a hydrothermal cement between the brecciated fragments. A tourmaline aureole surrounds the breccia pipe. Extensive tourmalinization of the granitic rocks near and within the pipe and no tourmalinization in the sedimentary and volcanic rocks. The tourmalines are marked by Fe-rich, black charcoal-like schorl (80 mol% schorl relative) nearer the schorl-dravite solid solution. The chemical changes in the hydrothermal fluid are reflected by variations in compositional Boning from cores to rims. They generally contain cores with low values of Fe/(Fe+Mg) and high values of Na/(Na+ca) relative to rims. This is because of an increase Fe and Ca contents toward rims. The main trend of these variations is a combination of the exchange vectors Ca(Fe, Mg) $(NaAl)_{- }$ $_1$ and $Fe^{3}^{+}$ $Al_{[-10]}$ $_1$ It is thought that boiling causes the loss of $H_2$ into the vapor phase resulting in the oxidation of Fe in the aqueous phase. pH of the melt would be one of important controlling factors for the tourmaline stability. The tourmalines could be precipitated when the system evolved to the acidic hydrothermal regime as most hydrothermal brines and acidic gases exsolved from the magma. The Ilgwang tourmaline crystallization is products of hypogene orthomagmatic hydrothermal processes that were strongly pipe-controlled.

Allogeneic Inlay Cortical Strut Grafts for Large Cysts or Post-curettage Cavitary Bony Defects (거대 낭종성 골병소 또는 소파 후 잔유 골 결손부에 시행한 내재형 동종 피질 지주골 이식술)

  • Chung, Yang-Guk;Kang, Yong-Koo;Kim, Chol-Jin;Lee, An-Hi;Park, Jeong-Mi;Bahk, Won-Jong;Yoo, Hyun-Ho
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.17 no.2
    • /
    • pp.73-78
    • /
    • 2011
  • Purpose: This study was aimed to evaluate the result of inlay cortical strut bone grafts for large cysts or cavitary bone lesions in long bones. Materials and Methods: Seven patients with large cyst or cavitary bony lesions were managed with curettage, allogeneic inlay cortical strut and cancellous bone grafts. Additional plate and screw fixations were performed in 6 patients. There were three SBCs, two FDs with secondary ABC changes, one FD and one post-cement spacer removal state. Three of them had pathologic fractures. Progression of bone healing and mechanical support and functional result were evaluated. The mean follow-up period was 25.4 months. Results: Incorporations into host bones were progressed in all, average 4.2 months in six metaphyseal regions and 5.8 months in five diaphyseal regions respectively. Full structural supports were achieved in all except one patient without any additional procedures. No allograft-related complication was developed. Mean functional score according to the MSTS criteria was 29.6 at last follow up. Conclusion: Inlay cortical strut graft provided additional mechanical stability and bone stock for screw purchase in large cyst or cavitary defects of long bones, which allow early mobilization and excellent functional outcome.

IN VITRO STUDY ON THE FLUORIDE RELEASE FROM GLASS IONOMER CEMENTS AND A FLUORIDE-CONTAINING RESIN (글라스 아이오노머 시멘트와 불소함유 레진의 불소유리에 관한 연구)

  • Kim, Mi-Kyung;Lee, Ki-Soo
    • The korean journal of orthodontics
    • /
    • v.28 no.3 s.68
    • /
    • pp.399-407
    • /
    • 1998
  • In order to resolve enamel demineralization around orthodontic bracket, fluoride-releasing materials, glass ionomer cements and fluoride-containing resin, were introduced in orthodontic department. There were many studies about their fluoride release, but their results were controversial. The purpose of this study was to clarify the pattern and amounts of fluoride release from glass ionomer cements and a fluoride-containing resin during 70 days in vitro. Disc shaped specimens were prepared and immersed in polyethylene tube containing 2ml distilled deionized water. The daily amounts of the fluoride released from each specimens were measured after experiment 1 day, 3 days, 7 days, 14 days, 42 days and 70 days. They were measured by fluoride-specific electrode combined pH/Ion meter. The following results were as follow, 1. Fluorides released from fluoride-containing resin during 1 day were significantly less than those from glass ionomer cements. 2. On experiment 70 days, mean daily amounts of fluoride released from Miracle-$Mix^{\circledR}$were $3.4{\mu}g/cm^2$, those from Fuji GC $II^{\circledR}$ were $2.7{\mu}g/cm^2$, those from $Orthobond^{\circledR}$ were $2.3{\mu}g/cm^2$, those from Fuji GC $LC^{\circledR}$were $1.4{\mu}g/cm^2$ and those from fluoride-containing resin, $Heliomolar^{\circledR}$, were $0.1{\mu}g/cm^2$. 3. There were no significant differences in daily amounts of fluoride released from between self-curing glass ionomer cements and light-curing glass ionomer cements. Amounts of released fluoride varied among commercially available products. 4. In all experimental materials, amounts of released fluoride decreased rapidly until experimental 3 days and then decreased slowly until 14 days and more slowly until 70 days.

  • PDF

Fracture Resistance of Low Invasive Fixed Partial Dentures (수종 저 침습 고정성 국소의치의 수직하중에 대한 저항)

  • Choi, Jong-In;Kim, Yu-Lee;Shin, Chang-Yong;Dong, Jin-Keun
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.26 no.3
    • /
    • pp.241-251
    • /
    • 2010
  • This study aims at contributing to the restorative dentistry by examining results in the vertical load test of four different low invasive fixed partial dentures. Based on a hypothesis on the right upper first molar is missing, three units of FPDs were made for the second premolar and the second molar abutment. that is, twelve metal dies and FPDs were made for resin bonded FPD and Two Key Bridges and Human Bridge without occlusal rest and Human Bridge with occlusal rest. By using universal test machine, the numerical maximum value were recorded during the vertical load test of each FPDs after the bonding process treated by Maxcem which is resin cement. The failure process and its result of prosthesis were also observed. The maximum load was 7,295 N, 4,729 N, 2,190 N, 3,073 N from groups of resin bonded FPD, Two Key Bridge, Human Bridge without occlusal rest and Human Bridge with occlusal rest respectively. There was a statistical significance among the groups of resin bonded FPD, Two Key Bridge and Human Brides. However, there was no significant difference between Human Bridge without occlusal rest and Human Bridge with occlusal rest. Regarding the failure of prosthesis, the groups of Resin Bonded FPD and Two Key Bridge showed that one of the abutment teeth in the both side of retention part was highly failed earlier than the other one (83.2% and 66.6% respectively). While, Human Bridge without occlusal rest and Human Bridge with occlusal rest showed high percentage of failure in the abutment teeth in the both side of retention part at the same time (91.6% and 58.3% respectively). This study demonstrates that the group of Human Bridges has low resistance to the vertical loads of low invasive FPDs in comparison with the groups of resin bonded FPD and Two Key Bridge. Nevertheless, the maximum occlusal load of the restorative position, resistance to diverse restoration failure, amount of tooth reduction and patients' cooperation should be considered when they are applied in the clinic in order to choose an appropriate restoration for each patient.

Microleakage of endodontically treated teeth restored with three different esthetic post and cores (심미적 포스트 코어의 종류에 따른 미세누출에 관한 연구)

  • Park, Ji-Geun;Park, Ji-Man;Park, Eun-Jin
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.47 no.1
    • /
    • pp.53-60
    • /
    • 2009
  • Statement of problem: At present, as the esthetic demands are on the increase, there are many ongoing studies for tooth-colored post and cores. Most of them are about fiber post and prefabricated zirconia post, but few about one-piece milled zirconia post and core using CAD/CAM (computer-aided design/computer-aided manufacturing) technique. Purpose: The objective of this study was to compare microleakage of endodontically treated teeth restored with three different tooth-colored post and cores. Material and methods: Extracted 27 human maxillary incisors were cut at the cementoenamel junction, and the teeth were endodontically treated. Teeth were divided into 3 groups (n=9); restored with fiber post and resin core, prefabricated zirconia post and heat-pressed ceramic core, and CAD/CAM milled zirconia post and core. After the preparation of post space, each post was cemented with dual-polymerized resin cement (Variolink II). Teeth were thermocycled for 1000 cycles between $5-55^{\circ}C$ and dyed in 2% methylene blue at $37^{\circ}C$ for 24 hours. Teeth were sectioned (bucco-lingual), kept the record of microleakage and then image-analyzed using a microscope and computer program. The data were analyzed by one-way ANOVA and Scheffe's multiple range test (${\alpha}=0.05$). Results: All groups showed microleakage and there were no significant differences among the groups (P>.05). Prefabricated zirconia post and heat-pressed ceramic core showed more leakage in dye penetration at the post-tooth margin, but there was little microleakage at the end of the post. Fiber post and resin core group and CAD/CAM milled zirconia post and core group indicated similar microleakage score in each stage. Conclusion: Prefabricated zirconia post and heat-pressed ceramic core group demonstrated better resistance to leakage, and fiber post and resin core group and CAD/CAM milled zirconia post and core group showed the similar patterns. The ANOVA test didn't indicate significant differences in microleakage among test groups. (P>.05)

Radiologic Evaluation of Limb Salvage Operation with Tumor Prosthesis (종양 대치물을 이용한 사지 구제술의 방사선학적 평가)

  • Moon, Sang-Ho;Lee, Sang-Hoon;Kim, Han-Soo;Oh, Joo-Han;Ko, Byung-Won;Koo, Ki-Hyung;Lee, Jae-Hag;Hwang, Chung-Soo;Lee, Han-Koo
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.6 no.4
    • /
    • pp.152-162
    • /
    • 2000
  • Purpose : To verify radiological changes of limb salvage operation using tumor prosthesis. Materials and Methods : Sixty-nine cases which used tumor prosthesis were reviewed. They have been followed up for average four years and nine months. We evaluated radiographs by ISOLS(International Symposium On Limb Salvage) radiological implants evaluation system immediate postoperatively, at postoperative 1 year and last follow-up. After converting 'excellent, good, fair, poor' to '4, 3, 2, 1' for stastical analysis, data were analyzed according to the use of cement, anatomical sites, diagnosis implant designs and age (<20 year vs. ${\geq}$20 year) using t-test and ANOVA. Results : The outcomes of cemented type prostheses were superior in remodelling and interface but inferior in anchorage. The scores of proximal femur and distal tibia were worse in bone remodelling. Osteosarcoma group had lower scores in anchorage and implant articular problem. There were no significant differences according to four different implant designs and age. Conclusion : In the intermediate term follow-up radiological evaluation, cemented type prosthesis were better in the aspects of bony resorption and osteolysis, and cementless one in anchorage. Distal femur and proximal tibia have higher scores in bony resorption, and osteosarcoma was worse tumor entity in anchorage and articular problem, and chemotherapy may be the cause.

  • PDF

Axial wall thickness of zirconia abutment in anterior region (전치부 지르코니아 지대주의 축벽 두께)

  • Moon, Seung-Jin;Heo, Yu-Ri;Lee, Gyeong-Je;Kim, Hee-Jung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.53 no.4
    • /
    • pp.345-351
    • /
    • 2015
  • Purpose: The purpose of this study was to evaluate the proper axial thickness of zirconia abutment applied to implant in the anterior region. Materials and methods: Zirconia abutments were prepared at different axial wall thickness by processing pre-sintered zirconia blocks via CAD/CAM to obtain equal specimens. The abutments were each produced with a thickness of 0.5 mm (Group 1), 0.8 mm (Group 2), 1.2 mm (Group 3), or 1.5 mm (Group 4). The implant used in this study was a external connection type one (US, Osstem, Pussan, Korea) product and the zirconia abutment was prepared via replication of a cemented abutment. The crowns were prepared via CAM/CAM with a thickness of 1.5 mm and were cemented to the abutments using $RelyX^{TM}$ UniCem cement. A universal testing machine was used to apply load at 30 degrees and measure fracture strength of the zirconia abutment. Results: Fracture strength of the abutments for Group 1, Group 2, Group 3, and Group 4 were $236.00{\pm}67.55N$, $599.00{\pm}15.80N$, $588.20{\pm}33.18N$, and $97.83{\pm}98.13N$, respectively. Group 1 showed a significantly lower value, as compared to the other groups (independent Mann-Whitney U-test. P<.05). No significant differences were detected among Group 2, Group 3, and Group 4 (independent Mann-Whitney U-test. P>.05). Conclusion: Zirconia abutment requires optimal thickness for fracture resistance. Within the limitation of this study, > 0.8 mm thickness is recommended for zirconia abutment in anterior implants.