• Title/Summary/Keyword: no-cement

Search Result 895, Processing Time 0.03 seconds

COMPARATIVE STUDY ON THE FRACTURE STRENGTH OF EMPRESS 2 CERAMIC AND TARGIS-VECTRIS CROWN

  • Cha Young-Joo;Yang Jae-Ho;Lee Sun-Hyung;Han Jung-Suk
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.39 no.6
    • /
    • pp.599-610
    • /
    • 2001
  • Due to an increasing interest in esthetics and concerns about toxic and allergic reactions to certain alloys, patients and dentists have been looking for metal-free tooth-colored restorations. Recent improvement in technology of new all-ceramic materials and composite materials has broadened the options for esthetic single crown restorations. The aim of this investigation was to study the fracture strength of the metal-free posterior single crowns fabricated using two recently introduced systems, Empress 2 ceramic and Targis-Vectris. Forty premolar-shaped stainless steel dies with the 1mm-wide circumferential shoulder were prepared. Ten cylindrical crowns having a diameter of 8.0mm and total height of 7.5mm were fabricated for each crown system respectively(PFM, Empress staining technique, Empress 2 layering technique, and Targis- Vectris). The crowns were filled with cement and placed on the stainless steel dies with firm finger pressure. The crowns were then stored in distilled water at room temperature for 24 hours before testing. The crowns were tested for fracture strength in an Instron universal testing machine (Instron 6022). With a crosshead speed of 1mm/min the center of the occlusal surface of the crown was loaded using a 4-mm-diameter stainless steel ball until fracture occurred. The fracture surfaces of the crowns were gold coated and examined using scanning electron microscopy(Jeol JSM-840 Joel Ltd., Akishima, Tokyo, Japan). Within the parameters of this study the following conclusions were drawn: 1. The mean fracture strength for PFM crowns was 5829(${\pm}906$)N; for Empress staining technique the fracture strength was 1697(${\pm}604$)N; for Empress 2 Layering technique the fracture strength was 1781N(${\pm}400$)N, and the fracture strength for Targis- Vectris was 3093(${\pm}475$)N. 2. The fracture strength of the PFM crowns was significantly higher than that of the Empress 2 and the Targis-Vectris crowns (P<0.05). 3. The fracture strength of the Targis-Vectris crowns was significantly higher than that of the Empress 2 crowns (P<0.05). 4. No statistical difference was found when Empress staining technique was compared with Empress 2 layering technique. 5. The SEM image of fracture surface of Empress 2 crown showed a very dense microstructure of the lithium disilicate crystals and the SEM image of fracture surface of Targis-Vectris crown showed indentations of Vectris and some fibers tom off from Vectris.

  • PDF

A STUDY ON THE REMOVAL TORQUE OF TITANIUM IMPLANTS (Titanium Implant의 Removal Torque에 관한 연구)

  • Lee, June-Seok;Kim, Yung-Soo;Kim, Chang-Whe
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.32 no.1
    • /
    • pp.148-169
    • /
    • 1994
  • The concept of biologic attachment of load-bearing implants has developed over the past decades as an alternative to the difficulties associated with long term implantation using mechanical fixation and bone cement. The choice of implant material is also as critical an element as site preparation or insertion procedure. The properties of implants that affect host tissue responses are not limited to chemical composition alone, but also include shape, surface characteristics, site of implantation, and mechanical interaction with host tissues. Initial mechanical interlocking prevents micromotion and may be a prerequisite for direct bone apposition. A hard tightening of screws does not necessarily mean a stronger fixation and final tightening of the fixtures is dependent on the experience of the operator. Removal torque is lower than insertion torque. The purpose of this study was to investigate differences in the removal torques at the bone-implant interface of polished and sandblasted Titanium. This experiment will give insight into important factors that must be considered when interpreting in vivo screwing forces on implants during the connection of the transmucosal abutments. We evaluated the significance of different surface textures by comparison of the withdrawal forces necessary for removal of otherwise identical rough and polished implants of Titanium and also evaluated interfacial response on the light microscopic level to implant surface. And the priority of the area of insertion on osseointegration were evaluated. 9 Titanium implants - among them, 3 were for the developmental - of either a smooth or rough surface finish were inserted in the dog mandible in the right side. 3 months later Kanon Torque Gauge was used to unscrew the implants. The results were as follows : 1. No significant difference was seen in the removal torque due to variation in surface treatment, 23 Ncm for the sandblasted and 23.33 Ncm for the polished surface (p>0.05). 2. Implants in the anterior (25 Ncm) mandible showed better resistance to unscrewing in comparison to ones in the posterior (18 Ncm) region (p<0.05). 3. Developmental fixtures (22 Ncm) had similar pullout strength to the control group (p>0.05).

  • PDF

Effects of immediate and delayed light activation on the polymerization shrinkage-strain of dual-cure resin cements (즉시 광중합과 지연 광중합이 이원 중합 레진시멘트의 중합 수축량에 미치는 영향)

  • Lee, So-Yeoun;Kim, Sung-Hun;Ha, Seung-Ryong;Choi, Yu-Sung;Kim, Hee-Kyung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.52 no.3
    • /
    • pp.195-201
    • /
    • 2014
  • Purpose: This study was designed to compare the amount of polymerization shrinkage of dual-cure resin cements according to different polymerization modes and to determine the effect of light activation on the degree of polymerization. Materials and methods: Four kinds of dual-cure resin cements were investigated: Smartcem 2, Panavia F 2.0, Clearfil SA Luting and Zirconite. Each material was tested in three different polymerization modes: self-polymerization only, immediate light polymerization and 5 minutes-delayed light polymerization. The time-dependent polymerization shrinkage-strain was evaluated for 30 minutes by Bonded-disk method at $37^{\circ}C$. Five recordings of each material with three different modes were taken. Data were analyzed using one-way ANOVA and multiple comparison Scheffe′test (${\alpha}$=.05). Results: All materials, except Panavia F 2.0, exhibited the highest polymerization shrinkage-strain through delayed light-activated polymerization. No significant difference between light activation modes was found with Panavia F 2.0. All materials exhibited more than 90% of polymerization rate in the immediate or delayed light activated group within 10 minutes. Conclusion: As a clinical implication of this study, the application of delayed light activation mode to dual-cure resin cements is advantageous in terms of degree of polymerization.

A Study on the Maternal and Child Health Status in a Rural Area (일부농촌지역(一部農村地域)의 모자보건실태(母子保健實態)에 관(關)한 연구(硏究))

  • Nam, Sang-Duk
    • Journal of Preventive Medicine and Public Health
    • /
    • v.7 no.2
    • /
    • pp.333-342
    • /
    • 1974
  • In September 1974, a survey was conducted towards 900 women respondents, each representing a household, residing in 18 selected Myuns(townships) of 18 Guns(counties) in Kyunggi-Do. Fifty households were selected randomly in each Myun and the sample Myuns were also randomly selected from the 18 Guns home-visiting interviews were carried out by Myun level maternal and child health workers with questionnair forms designed to measure the maternal and child health status at each household. Major findings obtained from this survey can be summarized as follows: 1. Of the women responents who were investigated in this survey, 13.1% of them were comprised in the illiterates, indicating no difference in literacy rate from that in most urban areas. 2. Most(93.8%) of the respondents were found to have married at ages of 20-24 years old. 3. Most(85.8%) of the respondents were found to have delivered their first babies at ages of 20-24, while only 13.4% had their first babies at 25-29. 4. About 22% of the respondents had 2 children, while 19% and another 19% had 2 and 4 children, respectively. 5. A great majority of the respondents (78%) experienced not a single death of a child within the family, while about 17% experienced death of one child. 0.7% of the women experienced deaths of 4 or more children. 6. 18% and 17% of the women experienced 4 and 3 pregnancies, respectively, and 12% of them experienced 7 or more pregnancies. 7. About 29% of the women experienced an induced abortion at least once. Nearly 2% of them were found to have experience of 4 or more induced abortions. 8. One half (51%) of the women were found to have received prenatal guidances in the latest pregnancies by (Ub(town) and Myun (township) level maternal and child health workers at least once or more times. 9. 52% women received professional prenatal care in the latest pregnancies: 24% at hospitals or clinics and 20% at health centers. 10. Most (89%) of the last-born children were delivered at home, while only 8.7% were delivered at hospital or clinics. 11. Materials used at delivery comprise vinyl (40%), cement bags (32%) ana gauzed or absorbent cottons (19%). 12. The largest preportion of the attendants at delivery comprises mothers in-law (48). Only 24% were found to be attended by either doctors, midwives or maternal and child health workers. 13. In most (90%) of the deliveries scissors were used to cut the umbilicus. But most (7%) of them used unsterilized scissors, 6 while only 20% of them used sterilized ones. 14. About 68% of the last-born babies were breast-fed for 12 months or more. Those who weaned during 6-12 months were 21%. 15. During 12 months after birth, 65% of the last-born babies were breast-fed, while 24% were given a combination of breast milk and cooked rice. 16. About nine out of the 10 births were found to be registered. 17. 71% of babies received BCG vaccination, while 79% and 56% received samllpox and DPT vaccinations, respectively within a year after birth. Those who were vaccinated against poliomyelitis were about 50%. 18. About 87% of the respondents recogninized the existence of government-sponsored maternal and child health guidance program.

  • PDF

Recycling Technologies of Waste Lubricating Oils and Their Promotion Policies in Korea and Foreign Countries (국내외 폐윤활유의 재활용기술 현황 및 재활용 촉진대책 조사분석)

  • Bae, Jae-Heum;Kwon, Sun-Dae
    • Clean Technology
    • /
    • v.12 no.3
    • /
    • pp.113-127
    • /
    • 2006
  • Waste lubricating oil(WLO)s have been recycled as energy source through direct fuel in cement kilns and fossil power plants, or as fuel oils, or re-refined lubricating base oils. In our country, they have been recycled as low grade fuel oil through chemical treatment process. In 2003, extended producer responsibility (EPR) system was adopted from deposit system on sale of lubricating oils in order to promote their recycleing rate. However, our recycling rate of WLOs have been stagnant(below 70%) for last 5 years. And there has been no research work on recycling of WLOs as re-refined base oil until now in this country. Stabilization technology of thermally cracked oils to reduce tar and malodor and to improve their color for production of high grade fuel oil, and a novel process production of high grade re-refined lubricating base oil from WLOs have been developed and commercialized recently in Canada and U.S.A., respectively. Several countries like Australia, Italy, Germany and U.S.A., etc. are encouraging recycling companies to recycle WLOs as re-refined lubricating oil by giving greater subsidies or benefits compared to other recycling methods. They also adopt a policy to purchase re-refined lubricating oil preferentially in the federal or local governments and to recommend consumers to purchase it willingly. Based on the facts that several advanced countries have adopted a policy to recycle WLOs as re-refined base oil for saving of petroleum resource and reduction of environmental pollution, it is right time to be considered that our present policy for recycling of WLOs should be reevaluated and the new policy of their environmental-friendly and sustainable recycling should be established.

  • PDF

Treatment of Open Proximal Humerus Fracture by Gunshot (총격에 의한 개방성 근위 상완골 골절의 치료 - 증례 보고 -)

  • Kim, Sung-Jae;Lee, Jae-Hoo;Chun, Yong-Min
    • Clinics in Shoulder and Elbow
    • /
    • v.15 no.1
    • /
    • pp.37-42
    • /
    • 2012
  • Purpose: To consider the proper management of proximal humerus fracture on gunshot wounds. Materials and Methods: A 28-year-old male patient, who sustained a gunshot injury on the left arm 5 days ago, was admitted through the emergency department. Although he underwent an emergency surgery (bullet fragment removal and debridement), there remained bullet fragments around the proximal humerus fracture site. The wound seemed to be infected and a partial dehiscence occurred. No neurologic deficit was noted. Immediate exploration and debridement were performed, and an external fixator was applied to restore the anatomical alignment and manage the wounds. Intravenous antibiotics were administered. On the 9th postoperative day, wound debridement was done again, and cement beads mixed with antibiotics were inserted. After two weeks, the external fixator was removed, and the pin sites were closed after debridement. One week later, the open reduction and internal fixation with locking compression plate and screws were done. Result: At 3 months after the internal fixation, the bone union was obtained with satisfactory alignment of the humerus. Conclusion: The severity of the soft tissue injury influences the fracture management plan. Further, the risk on lead toxicity should be considered.

A Study on the Temperature Distribution of Rock Mass at KAERI Underground Research Tunnel: Verification on the Result of Borehole Heater Test (지하처분연구시설(KURT) 내 암반의 온도 분포에 관한 연구 : 시추공히터시험 결과의 검증)

  • Yoon, Chan-Hoon;Choi, Young-Chul;Kwon, Sang-Ki;Choi, Heui-Joo
    • Tunnel and Underground Space
    • /
    • v.23 no.4
    • /
    • pp.297-307
    • /
    • 2013
  • In this study, the thermal analysis is carried out for a result of borehole heater test using ABAQUS ver 6.10 based on finite element analysis code. Thermal-mechanical rock properties as determined by laboratory tests before the in situ test and characteristics of the atmosphere at the test section are used as the initial condition. When comparing the results of the in situ test and thermal analysis, the temperature of C3 observation hole that is 0.9 m away from the heater showed very similar patterns and figures (about $1.3^{\circ}C$ difference). But the results of the A and B observation hole showed a significant difference around $15^{\circ}C{\sim}20^{\circ}C$. To find the reason for these results, the over-coring is carried out for the A1 and B1 observation holes. As a result of checking the excavated rock core with the naked eye, there is no problem on the number and position of the sensor as the test plan. However the state of cement injection in the observation hole is poor.

Reconstruction with Extracorporeally Radiated Autogenous Bone Graft After Wide Resection of Bone Tumors (골종양 절제후 방사선 조사한 자가골을 이용한 재건술)

  • Lee, Jong-Seok;Jeon, Dae-Geun;Kim, Sug-Jun;Lee, Soo-Yong;Yang, Hyun-Seok
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.3 no.1
    • /
    • pp.32-38
    • /
    • 1997
  • PURPOSE : For the reconstruction of large bone defect after tumor resection, it is possible to reuse the bone involved by tumor with some treatment to it. Several bone-reusing methods have been reported such as autoclaving, low-heat treatment(pasteurization) and intraoperative radiotherapy. We have used extracorporeally radiated autogenous bone graft for reconstruction after tumor resection, and analyzed the periods for junctional union, functional results and complications to know the indications of this method. METHODS : From Dec. 1993 to Sept. 1995, nine patients had taken autogenous bone graft with extracorporeal irradiation. Eight cases were osteosarcoma and 1 giant cell tumor. The graft sites were 5 in femur, 3 proximal tibia and 1 femur and tibia. Stage 3 was 1 case(GCT), Stage IIB 3 and Stage IIIB 5. After wide resection, surrounding soft tissue and intramedullary and extramedullary portion of the tumor were removed. Radiation was done in 5000cGy to the resected bone. Ender nails and bone cement were inserted and filled into the medulla to prevent fracture. RESULTS : Average follow-up period was 12.3(4 to 21) months. Average junctional union period in simple X-ray was 6.5 months in 4 cases. Average functional score following Enneking's criteria was 19(12-27). Complications were as follows ; condylar fractures and femur neck fracture in 4 cases, subluxation of the knee joint 3 and infection 1. Although local recurrence was detected in 1 case, the site of recurrence was not in the radiated bone but surrounding soft tissue. At final follow-up, no recurrence was found in one case(GCT), CDF 2, AWD 2, DOD 3, and died of chemotherapy related sepsis 1. CONCLUSIONS : Extracorporeally radiated bone autograft is considered to be a method for reconstruction of the large bone defect made by tumor resection, especially in the reconstruction around the joint.

  • PDF

Fabrication of lightweight geopolymer based on the IGCC slag (IGCC 용융 슬래그를 이용한 경량 지오폴리머 제조)

  • Park, Soo-bin;Kim, Kang-duk;Kang, Seung-gu
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.27 no.6
    • /
    • pp.319-326
    • /
    • 2017
  • In this study, a lightweight geopolymer was prepared using by slag discharged from IGCC (Integrated Gasification Combined Cycle) power plant and its physical properties, the density and compressive strength, were analyzed as a function of the concentration of alkali activators, W/S ratio and aging times. Also the possibility of applying it to lightweight materials by adding Si sludge as a foaming agent to the geopolymerg was investigated. In particular, a complex composition of alkali activator and a pre-curing process were applied to improve the strength properties of lightweight geopolymers. While the compressive strength of the lightweight geopolymer using a single activator was 9.5 MPa, the specimen made with a complex composition of alkali activator had compressive strength of 2~5 times higher. In addition, the lightweight geopolymer with pre-curing process showed a compressive strength value of 18~48 % higher than that of specimen made with no precuring process. In this study, by using a complex activator and a pre-curing process. the maximum compressive strength of lightweight geopolymer was obtained as 40 MPa (The specimen was aged for 3 days and had density of $1.83g/cm^3$), which is comparable to cement concrete. By analyzing the crystal phase and microstructure of geopolymers obtained in this study using by XRD and SEM, respectively, it was confirmed that the flower-bud-like zeolite crystal was homogeneously distributed on the surface of the C-S-H gel (sodium silicate hydrate gel) in the geopolymer.

Fracture strength of zirconia ceramic crowns according to tooth position (치아 부위에 따른 지르코니아 도재관의 파절강도)

  • Lee, In-Seob;Kim, Jeong-Mi;Dong, Jin-Keun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.48 no.2
    • /
    • pp.94-100
    • /
    • 2010
  • Purpose: The purpose of this study was to compare the fracture strength of the zirconia ceramic crowns according to tooth position. Material and methods: After 10 metal dies were made for each group, the zirconia ceramic crowns were fabricated using CAD/CAM system ($Lava^{TM}$ All-Ceramic System) and each crown was cemented on each metal die with resin cement (Rely $X^{TM}$ Unicem). The cemented zirconia ceramic crowns mounted on the testing jig were inclined with 30 degrees to the long axis of the tooth and the universal testing machine was used to measure the fracture strength. Results: 1. The fracture strength of the zirconia ceramic crown in the lower 1st molar (2963 N) had the highest and that in the lower central incisor (1035 N) had the lowest. 2. The fracture strength of zirconia ceramic crown was higher than that of the IPS Empress crowns in all tooth position. 3. The fracture mode of the crowns was similar. Most of fracture lines began at the loading area and extended through proximal surface perpendicular to the long axis of the crowns. 4. There were no significant differences on the fracture strength of the zirconia ceramic crowns according to tooth position except in premolar group. Conclusion: Within the limitations of this study, the results suggested that strength of zirconia ceramic crown is satisfactory for clinical use.