• Title/Summary/Keyword: new effective temperature

Search Result 455, Processing Time 0.027 seconds

A cycle simulation of the S.I. engine and it's verification test (S.I. 엔진의 사이클 시뮬레이션 및 이의 확인 실험)

  • 목희수;김승수
    • Journal of the korean Society of Automotive Engineers
    • /
    • v.10 no.6
    • /
    • pp.72-84
    • /
    • 1988
  • Engine performance is one of the main objectives specified at the beginning of a new engine design project. The cycle simulation for SI engine is based on the zero-dimensional gas exchange model and a heat release expression by Viebe. This program also requires minimum input data and takes only a short time to run. Heat transfer from cylinder transfer formula. The flow coefficient (effective area) is calculated from valve lift using the standard flow coefficient curve and engine friction is calculated from the Millington and Hartles' engine friction formula. The chemical species considered in burned gas are 6 species CO, CO, H$_{2}$, H$_{2}$O, $O_{2}$, N$_{2}$ and the cylinder pressure, homogeneous cylinder temperature, gas composition and burned fraction are calculated at each crank angle through the cycle. To check the validity and accuracy, experimental study was done with 3 engines for measuring cylinder pressure, indicated mean effective pressure, brake mean effective pressure and air flow rate, etc. Despite its simple assumptions, cycle simulation showes excellent breathing and performance correlation when compared with data of tested engines, and have been proved useful in engine design.

  • PDF

Effects of Process Variables on the Gas Penetrated Part in Gas-Assisted Injection Molding

  • Han, Seong-Ryeol;Park, Tae-Won;Jeong, Yeong-Deug
    • International Journal of Precision Engineering and Manufacturing
    • /
    • v.7 no.2
    • /
    • pp.8-11
    • /
    • 2006
  • Gas-assisted injection molding (GAIM) process reduces the required injection pressure during mold filling stage as well as the shrinkage and warpage of the part and cycle time. Despite of these advantages, this process needs new parameters and makes the application more difficult because gas and melt interact during the injection molding process. Important GAIM factors involved in this process are gas penetration design, locations of gas injection points, shot size, delay time to inject gas as well as common injection molding parameters. In this study, the experiments are conducted to investigate effects of GAIM process variables on the gas penetration for PP (Polypropylene) and ABS (Acrylonitrile Butadiene Styrene) moldings by changing the gas injection point. Taguchi method is used for the design of the experiments. When the gas is injected at a cavity's center, the most effective factor is the shot size. When the gas is injected at a cavity's end, the most effective factor is the melt temperature. The injection speed is also an effective factor in GAIM process.

An Experimental Study on the Heat Transport Characteristics of a Sodium Heat Pipe for a Solar Furnace (태양열 반응로용 나트륨 히트파이프의 열이송 특성에 관한 실험적 연구)

  • Boo, Joon-Hong;Park, Cheol-Min;Kim, Jin-Soo;Kang, Yong-Heack
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2008.05a
    • /
    • pp.178-181
    • /
    • 2008
  • Cylindrical stainless-steel/sodium heat pipe for a high-temperature application was manufactured and tested for transient and steady-state operations. The container material was made of stainless-steel 316, and the working fluid was sodium. Stainless-steel 316 mesh screen was inserted as a capillary structure. The working fluid fill charge ratio was approximately 64 $\sim$ 181% based on the pore space of the wick. The outer diameter of the heat pipe was 12.7 mm and the total length was 250 mm. The evaporator part was 150 mm and the condenser 80 mm. The performance test of the heat pipe has been conducted in the furnace with up to 800 W. The variation of the average heat transfer coefficient was investigated as a function of heat flux and vapor temperature. As input thermal load increased, it was showed that difference of temperatures in evaporator and condenser decreased and that operating section and heat transfer characteristics at the heat pipe increased.

  • PDF

Study on the aquifer utilization for a ground water heat pump system (지하수 히트펌프 시스템의 대수층 활용 사레 연구)

  • Shim, Byoung-Ohan;Lee, Chul-Woo
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2006.11a
    • /
    • pp.32-35
    • /
    • 2006
  • The validation of a groundwater source heat pump system installation site is estimated by bydrogeothermic model ing. The hydraulic characteristics of the aquifer system is evaluated from pumping and recovery tests. In addition, the temperature distribution by the pumping and the injection of groundwater, and water level fluctuations are simulated by numerical modeling. The total cooling and heating load for the building is designed as 120RT(refrigeration ton) and the ground water source heat pump system covers 50RT as a subsidiary system The scenario of heat pump operation is organized as pumping and inject ion of groundwater that is performed for 8 hours per day in cooling mode for 90 days during the summer season The heat transfer by the injected warm water is limited near the inject ion wells in the simulated temperature distribution. The reason is that the given operation time is too short to expect broad thermal diffusion in large volume of the aquifer in the simulation time The simulated groundwater level and temperature distribution can be used as important data to develope an energy effective pumping and injection well system. Also it will be very useful to evaluate the hydraulic capacity of a target groundwater reservoir.

  • PDF

Photodetection Mechanism in Mid/Far-Infrared Dual-Band InAs/GaSb Type-II Strained-Layer Superlattice

  • No, Sam-Gyu;Lee, Sang-Jun;Krishna, Sanjay
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.02a
    • /
    • pp.127-127
    • /
    • 2010
  • Owing to many advantages on indirect intersubband absorption from the hole miniband to the electron miniband based on the type-II band alignment in InAs/GaSb strained-layer superlattice (SLS), InAs/GaSb SLS infrared photodetector (SLIP) has emerged as a promising system to realize high-detectivity quantum photodetector operating up to room temperature in the spectral range of mid-infrared (MIR) to far-infrared (FIR). In particular, n-barrier-n (n-B-n) structure designed for blocking the majority-carrier dark current makes it possible for MIR/FIR dual-band SLIP whose photoresponse (PR) band can be exclusively selected by the bias polarity. In this study, we present the MIR and FIR photoresponse (PR) mechanism identified by dual-band PR spectra and photoluminescence (PL) profiles taken from InAs/GaSb SLIP. In the MIR/FIR PR spectra measured by changing bias polarity, each spectrum individually shows a series of distinctive peaks related to the transitions from the hole subbands to the conduction one. The PR mechanism at each polarity is discussed in terms of diffusion current, and a superposition of MIR-PR in the FIR-PR spectrum is explained by tunnelling of electrons activated in MIR-SLS. The effective FIR-PR spectrum decomposed into three curves for HH1, LH1, and HH2 has revealed the edge energies of 120, 170, and 220 meV, respectively, and the temperature variation of the MIR-PR edge energies shows that the temperature behavior of the SLS systems can be approximately expressed by the Varshni empirical equation.

  • PDF

Investigation into the Worst Stress Condition for an Accelerated Life Test of a Compressor in Refrigerators - Acceleration Factor and the Reducible Test Time under High Temperature - (냉장고용 압축기의 가속수명시험을 위한 가혹조건 탐색 - 고온 가혹조건에서의 가속계수와 단축 시험기간 -)

  • Jung, Y.M.;Joo, W.J.;Jeong, S.K.
    • Journal of Power System Engineering
    • /
    • v.16 no.3
    • /
    • pp.44-50
    • /
    • 2012
  • The reliability qualification test is essential in order to ensure the life time of the product under the normal operation conditions when a new product is developed. The reliability qualification test period has an important impact on the development time of new product. Therefore, some researches to reduce the test time of reliability qualification test have been actively studied. Generally, accelerated life test is well known as one method that can save the test time of the reliability qualification test. This test is conducted under the higher stress condition than normal condition. So we need to investigate what factor affects to the higher stress condition. This paper shows the relationship between the acceleration factor and reliability qualification test period. Especially, we focused on the method to obtain effective acceleration factors under the high temperature condition. Through some experiments for a refrigerator's compressor, we were able to confirm how to increase acceleration factors and how to reduce the reliability qualification test period with minimum samples.

Influence of Various Catalysts on the Biomass Pyrolysis Reaction (바이오매스 열분해 반응에서 다양한 촉매의 영향)

  • BAK, YOUNG-CHEOL;CHOI, JOO-HONG
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.28 no.5
    • /
    • pp.536-544
    • /
    • 2017
  • The effects of catalysts addition on the pyrolysis reaction of biomass have been studied in a thermogravimetric analyzer (TGA). The sample biomasses were Bamboo, Pine and Hinoki. The catalysts tested were K, Zn, Cu metal compounds. The pyrolysis reactions were tested in the nonisothermal condition from the room temperature to $550^{\circ}C$ at a heating rate $50^{\circ}C/min$ on the flowing of $N_2$ purge gases. Cellulose contents of Bamboo was higher than that of Pine and Hinoki. As the results, the pyrolysis reaction of volatile matter was finished near the temperature $450^{\circ}C$. The initial decomposition temperatures of the volatile matters ($T_i$) were $165^{\circ}C$ for Bamboo, $190^{\circ}C$ for Pine, and $193^{\circ}C$ for Hinoki. $T_i$ decreased with increasing the catalyst amounts in the sample biomasses. The temperature of maximum reaction rate ($T_{max}$) were $338^{\circ}C$ for Bamboo, $378^{\circ}C$ for Pine, and $377^{\circ}C$ for Hinoki. The effects of catalysts addition on the $T_{max}$ were to decreased it. The reducing effects about $T_{max}$ was the most effective for K metal compounds catalyst. The char amounts remained after pyrolysis at $550^{\circ}C$ were 26.2% for Bamboo, 20.7% for Pine, and 20.9% for Hinoki. The char amounts increased with the catalyst amounts.

The Effects of Silica-Alumina Type Inorganic Compounds on the Pyrolysis Reaction of EVA to Produce Fuel-Oil (EVA 수지 이용 연료유 생성을 위한 열분해 반응에서 실리카-알루미나 계열 무기물의 영향)

  • Bak, Young-Cheol;Choi, Joo-Hong;Oh, Se-Hui
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.22 no.5
    • /
    • pp.706-713
    • /
    • 2011
  • The effects of silica-alumina type catalysts addition on the thermal decomposition of ethylene vinyl acetate (EVA) resin have been studied in a thermal analyzer (TGA, DSC) and a small batch reactor. The silica-alumina type compounds tested were kaolinite, bentonite, perlite, activated clay and clay. As the results of TGA experiments, pyrolysis starting temperature for EVA resin had the 1st pyrolysis temperature range of 300~$400^{\circ}C$ and the 2nd pyrolysis temperature range of 425~$525^{\circ}C$. The silica-alumina type catalysts did not affect the pyrolysis rate in EVA pyrolysis reaction. In the DSC experiments, addition of kaolinite and bentonite catalysts reduced the heat of fusion and heat of 2nd pyrolysis reaction. In the batch system experiments, the mixing of silica-alumina type catalysts enhanced the yield of fuel oil, and affected to the distribution of carbon numbers. In the silica-alumina type inorganic material used in this experiments, bentonite was the most effective from the pyrolysis heat, yields, and the characteristics of fuel oil.

Experimental and numerical studies on the shear connectors in steel-concrete composite beams at fire and post fire exposures

  • Mirza, Olivia;Shil, Sukanta Kumer;Rashed, M.G.;Wilkins, Kathryn
    • Steel and Composite Structures
    • /
    • v.39 no.5
    • /
    • pp.529-542
    • /
    • 2021
  • Shear connectors are required to build composite (concrete and steel) beams. They are placed at the interface of concrete and steel to transfer shear and normal forces between two structural components. Such composite beams are sensitive to provide structural integrity when exposed to fire as they loss strength, stiffness, and ductility at elevated temperature. The present study is designed to investigate the shear resistance and the failure modes of the headed stud shear connectors at fire exposure and post-fire exposure. The study includes ordinary concrete and concrete with carbon nanotubes (CNTs) to build composite (concrete-steel) beams with structural steel. Experimental push tests were conducted on composite beams at ambient and elevated temperatures, such as 200, 400 & 600℃. Moreover, push tests were performed on the composite beams after being exposed to 200, 400 & 600℃. Push test results illustrated the reduction of ultimate shear capacity and stiffness of headed stud shear connectors as the temperature increased. Although similar values of ultimate shear were obtained for the headed stud connectors in both ordinary and CNT concrete, the CNT modified concrete reduced the concrete spalling and cracking compared to ordinary concrete and was observed to be effective at temperatures greater than 400℃. All specimens showed a lower shear resistance at fire exposures compared to the corresponding post-fire exposures. Moreover, numerical simulation by Finite Element (FE) analyses were carried out at ambient temperature and at fire conditions. The FE analysis results show a good agreement with the experimental results. In the experimental studies, failure of all specimens occurred due to shear failure of headed stud, which was later validated by FE analyses using ABAQUS.

Numerical Simulation for the Subsurface Temperature Distribution Disturbed by Heat-Pump Operation (지열펌프 구동에 의한 지중 온도 분포 변화 모델링 연구)

  • Shin, Ji-Youn;Bae, Gwang-Ok;Lee, Kang-Kun
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2006.11a
    • /
    • pp.40-43
    • /
    • 2006
  • Public demand for the heat pump system as a next generation energy equipment is increasing for its eco-friendly and cost-effective advantage. Many researches have been concentrated on how to calculate and develop its own efficiency, while the possible effect of the heat pump operation on the whole subsurface temperature distribution is relatively less considered, During the current study, subsurface temperature disturbance caused by seasonal surface temperature cycle in Busan area and general W-tube heat pump operation is simulated in 3-dimensional heterogeneous medium. It shows that subsurface deeper than 10m from the surface remains nearly unchanged throughout the 4 seasons and groundwater convect ion in highly permeable layer near the surface acts like a main path of heat plume from heat pump system, This implies the significance of detail descript ion in shallow sedimentary layer or highly permeable layer which plays an important role on the regional flow advection and heat transfer. Also, the effect of groundwater convection increases when the arrangement of the 2 injection pipes and 2 extract ion well is maintained parallel to groundwater flow. Therefore, more careful and detail investigation is required before installation and operation of heat pump system that it may not cause any possible change of microbial ecosystem in the shallow subsurface environment or 'contamination of temperature' for groundwater use as well as the loss of efficiency of the equipment itself. This can also help to design the optimized grouting system for heat pump.

  • PDF