• Title/Summary/Keyword: neutrons dose

Search Result 83, Processing Time 0.024 seconds

A Study on the Photoneutron Dose Estimation in Flattening Filter Mode and Flattening Filter Free Mode for Medical Linear Accelerator (의료용 선형가속기의 Flattening Filter Mode와 Flattening Filter Free Mode 간에 광중성자 선량 평가)

  • Yang, Oh Nam;Lim, Cheong Hwan
    • Journal of radiological science and technology
    • /
    • v.40 no.2
    • /
    • pp.297-302
    • /
    • 2017
  • In this study, the generation of photoneutrons between the 10 MV FF mode and the FFF mode was evaluated and the amount of photoneutrons generated by the 10 MV and 15 MV energy changes in the FFF mode was evaluated. The generated neutrons were evaluated at 13 measurement points and the KTEPC was used to collect the generated neutrons. 10 MV FF mode was measured at 10 MV FF mode and FFF mode at all measurement points. In the superior direction, 0.455mSv and 0.152mSv were the largest, and more than 33% optical neutron was generated in FF. 10 MV in FFF mode, 15 MV in 15 MV, and 0.402 mSv in the direction of Superior, and 6.9% in the direction.

INITIAL ESTIMATION OF THE RADIONUCLIDES IN THE SOIL AROUND THE 100 MEV PROTON ACCELERATOR FACILITY OF PEFP

  • An, So-Hyun;Lee, Young-Ouk;Cho, Young-Sik;Lee, Cheol-Woo
    • Nuclear Engineering and Technology
    • /
    • v.39 no.6
    • /
    • pp.747-752
    • /
    • 2007
  • The Proton Engineering Frontier Project (PEFP) has designed and developed a proton linear accelerator facility operating at 100 MeV - 20 mA. The radiological effects of such a nuclear facility on the environment are important in terms of radiation safety. This study estimated the production rates of radionuclides in the soil around the accelerator facility using MCNPX. The groundwater migration of the radioisotopes was also calculated using the Concentration Model. Several spallation reactions have occurred due to leaked neutrons, leading to the release of various radionuclides into the soil. The total activity of the induced radionuclides is approximately $2.98{\times}10^{-4}Bq/cm^3$ at the point of saturation. $^{45}Ca$ had the highest production rate with a specific activity of $1.78{\times}10^{-4}Bq/cm^3$ over the course of one year. $^3H$ and $^{22}Na$ are usually considered the most important radioisotopes at nuclear facilities. However, only a small amount of tritium was produced around this facility, as the energy of most neutrons is below the threshold of the predominant reactions for producing tritium: $^{16}O(n,\;X)^3H$ and $^{28}Si(n,X)^3H$ (approximately 20 MeV). The dose level of drinking water from $^{22}Na$ was $1.48{\times}10^{-5}$ pCi/ml/yr, which was less than the annual intake limit in the regulations.

Enhancing Gamma-Neutron Shielding Effectiveness of Polyvinylidene Fluoride for Potent Applications in Nuclear Industries: A Study on the Impact of Tungsten Carbide, Trioxide, and Disulfide Using EpiXS, Phy-X/PSD, and MCNP5 Code

  • Ayman Abu Ghazal;Rawand Alakash;Zainab Aljumaili;Ahmed El-Sayed;Hamza Abdel-Rahman
    • Journal of Radiation Protection and Research
    • /
    • v.48 no.4
    • /
    • pp.184-196
    • /
    • 2023
  • Background: Radiation protection is crucial in various fields due to the harmful effects of radiation. Shielding is used to reduce radiation exposure, but gamma radiation poses challenges due to its high energy and penetration capabilities. Materials and Methods: This work investigates the radiation shielding properties of polyvinylidene fluoride (PVDF) samples containing different weight fraction of tungsten carbide (WC), tungsten trioxide (WO3), and tungsten disulfide (WS2). Parameters such as the mass attenuation coefficient (MAC), half-value layer (HVL), mean free path (MFP), effective atomic number (Zeff), and macroscopic effective removal cross-section for fast neutrons (ΣR) were calculated using the Phy-X/PSD software. EpiXS simulations were conducted for MAC validation. Results and Discussion: Increasing the weight fraction of the additives resulted in higher MAC values, indicating improved radiation shielding. PVDF-xWC showed the highest percentage increase in MAC values. MFP results indicated that PVDF-0.20WC has the lowest values, suggesting superior shielding properties compared to PVDF-0.20WO3 and PVDF-0.20WS2. PVDF-0.20WC also exhibited the highest Zeff values, while PVDF-0.20WS2 showed a slightly higher increase in Zeff at energies of 0.662 and 1.333 MeV. PVDF-0.20WC has demonstrated the highest ΣR value, indicating effective shielding against fast neutrons, while PVDF-0.20WS2 had the lowest ΣR value. The Monte Carlo N-Particle Transport version 5 (MCNP5) simulations showed that PVDF-xWC attenuates gamma radiation more than pure PVDF, significantly decreasing the dose equivalent rate. Conclusion: Overall, this research provides insights into the radiation shielding properties of PVDF mixtures, with PVDF-xWC showing the most promising results.

Irradiation Induced Defects in a Si-doped GaN Single Crystal by Neutron Irradiation

  • Park, Il-Woo
    • Journal of the Korean Magnetic Resonance Society
    • /
    • v.12 no.2
    • /
    • pp.74-80
    • /
    • 2008
  • The local structure of defects in undoped, Si-doped, and neutron irradiated free standing GaN bulk crystals, grown by hydride vapor phase epitaxy, has been investigated by employing electron magnetic resonance(EMR), Raman scattering and cathodoluminescence. The GaN samples were irradiated to a dose of $2{\times}10^{17}$ neutrons in an atomic reactor at Korea Atomic Energy Research Institute. There was no appreciable change in the Raman spectra for undoped GaN samples before and after neutron irradiation. However, a forbidden transition, $A_1$(TO) mode, appeared for a neutron irradiated Si-doped GaN crystal. Cathodoluminescence spectrum for the neutron irradiated Si-doped GaN crystal became much broader or was much more broadened than that for the unirradiated one. The observed EMR center with the g value of 1.952 in a neutron irradiated Si-doped GaN may be assigned to a Si-related complex donor.

Fast Neutron Dosimetry in Nuclear Criticality Accidents (핵임계사고시(核臨界事故時)에 있어서 속중성자선량(速中性子線量) 측정(測定))

  • Yook, Chong-Chul;Ro, Seung-Gy
    • Journal of Radiation Protection and Research
    • /
    • v.2 no.1
    • /
    • pp.17-23
    • /
    • 1977
  • The neutron dosimetrical parameters, i. e., the fission neutron spectrum-averaged cross-sections and the fluence-to-dose conversion factors have been calculated for some threshold detectors with the aid of a computer. The threshold detectors under investigation were the $^{115}In(n,\;n')^{115m}In,\;^{32}S(n,\;p)^{32}P$ and $^{27}Al(n,\;{\alpha})^{24}Na$ reactions. It is revealed that the average cross-sections($\bar{\sigma}$) for the $^{32}S(n,\;p)^{32}P$ reaction are independent of the spectral functions, namely, the Watt-Cranberg and Maxwellian forms. In the case of the $^{27}Al(n,\;{\alpha})^{24}Na$ reaction a variation of the $\bar{\sigma}$ values appears to be highly dependent on the fissioning types. It seems that both the average cross-section for the $^{115}In(n,\;n')^{11m}In$ reaction and the conversion factor are insensitive to the spectral deformation of fission neutrons. These phenomena make it applicable to use indium as a possible integral fast neutron dosimeter in nuclear criticality accidents provided that the virgin fission neutrons are completely free from the scattered neutrons.

  • PDF

Average and Effective Energies, and Fluence-Dose Equivalent Conversion Factors for $^{239}Pu-Be,\;^{241}Am-Li\;and\;^{241}Am-F$ Neutron Sources

  • Ro, Seung-Gy;Yoo, Young-Soo
    • Nuclear Engineering and Technology
    • /
    • v.3 no.3
    • /
    • pp.155-160
    • /
    • 1971
  • Average and effective energies for 239Pu-Be, 241Am-Li and 241Am-F neutron sources have been calculated from a number of published data for the neutron spectra and for the dose equivalent as a function of neutron energies by a numerical method. Also a calculation of the dose equivalent conversion factors, i. e., the first collision dose equivalent and the surface (or multicollision) dose equivalent that equals the product of surface-absorbed dose and a corresponding quality factor, per unit fluence of neutrons from these sources has been carried out in the same way as before. The results are as follows : 1. for average energies 4.07$\pm$0.33, 0.42 and 1.41 MeV; 2. for effective energies based on the concept of the first collision process in the human body 4.45$\pm$0.344, 0.51 and 1.47 MeV; 3. for effective energies based on the concept of the multi-collision process in the human body 4.50$\pm$0.36, 0.50 and 1.45 MeV; 4. for fluence-first collision dose equivalent conversion factors (2.74$\pm$0.07)10$^{-8}$ , 1.58$\times$ 10$^{-8}$ and 2.34$\times$10$^{-8}$ rems/(n/$\textrm{cm}^2$); and 5. for fluence-surface dose equivalent conversion factors (3.55$\pm$0.09)10$^{-8}$ , 2.19$\times$10$^{-8}$ and 2.82$\times$10$^{-8}$ rems/(n/$\textrm{cm}^2$) : respectively.

  • PDF

Estimation of Dose Distribution on Carbon Ion Therapy Facility using Monte Carlo Simulation (몬테카를로 시뮬레이션을 이용한 중입자 치료실의 선량분포 추정)

  • Song, Yongkeun;Heo, Seunguk;Cho, Gyuseok;Choi, Sanghyun;Han, Moojae;Park, Jikoon
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.6
    • /
    • pp.437-442
    • /
    • 2017
  • Heavy ion therapy has a high cure rate for cancer cell. So many countries are introducing heavy ion therapy facility. When treating a cancer using heavy ion therapy, neutrons and gamma rays are generated and affect electronic equipment. A budget of about KRW 200 billion is needed to build a heavy ion therapy facility, and it takes more than five years to build it. Therefore it is important to observe the dose distribution in the treatment room using the monte carlo simulation before construction. In this study, we used the FLUKA of monte carlo simulation to investigate the dose distribution in the heavy ion treatment room.

Fast Neutron Dosimetry with Two Threshold Detectors in Criticality Accidents of Nuclear Reactors

  • Ro, Seung-Gy
    • Nuclear Engineering and Technology
    • /
    • v.2 no.2
    • /
    • pp.85-95
    • /
    • 1970
  • An attempt has been made to do interpretation of the fast neutron dose with two threshold detectors incorporated with the Harwell criticality locket. This method is based on the assumption that the spectral distribution of fission neutrons in criticality accidents may be governed by one spectral parameter. The surface-absorbed dose for a unit fission neutron fluence seems to be insensitive to spectral shifts of the fission neutron spectrum. The average cross-sections for the activation detectors, however, are considerably changed with the neutron spectral shape, which may lead to a large error in calculating the dose from the reaction rate if one uses a fixed value for the average cross sections regardless of the neutron spectral distribution. Besides, the doses calculated from three representative formulae for fission neutron spectra have been compared : these formulae are Watt, Cranberg at al. and Maxwellian forms. The results obtained front the Maxwellian formula show a departure from the Watt and Cranberg's, both being similarly close.

  • PDF

Investigation on Individual Variation of Organ Doses for Photon External Exposures: A Monte Carlo Simulation Study

  • Yumi Lee;Ji Won Choi;Lior Braunstein;Choonsik Lee;Yeon Soo Yeom
    • Journal of Radiation Protection and Research
    • /
    • v.49 no.1
    • /
    • pp.50-64
    • /
    • 2024
  • Background: The reference dose coefficients (DCs) of the International Commission on Radiological Protection (ICRP) have been widely used to estimate organ doses of individuals for risk assessments. This approach has been well accepted because individual anatomy data are usually unavailable, although dosimetric uncertainty exists due to the anatomical difference between the reference phantoms and the individuals. We attempted to quantify the individual variation of organ doses for photon external exposures by calculating and comparing organ DCs for 30 individuals against the ICRP reference DCs. Materials and Methods: We acquired computed tomography images from 30 patients in which eight organs (brain, breasts, liver, lungs, skeleton, skin, stomach, and urinary bladder) were segmented using the ImageJ software to create voxel phantoms. The phantoms were implemented into the Monte Carlo N-Particle 6 (MCNP6) code and then irradiated by broad parallel photon beams (10 keV to 10 MeV) at four directions (antero-posterior, postero-anterior, left-lateral, right-lateral) to calculate organ DCs. Results and Discussion: There was significant variation in organ doses due to the difference in anatomy among the individuals, especially in the kilovoltage region (e.g., <100 keV). For example, the red bone marrow doses at 0.01 MeV varied from 3 to 7 orders of the magnitude depending on the irradiation geometry. In contrast, in the megavoltage region (1-10 MeV), the individual variation of the organ doses was found to be negligibly small (differences <10%). It was also interesting to observe that the organ doses of the ICRP reference phantoms showed good agreement with the mean values of the organ doses among the patients in many cases. Conclusion: The results of this study would be informative to improve insights in individual-specific dosimetry. It should be extended to further studies in terms of many different aspects (e.g., other particles such as neutrons, other exposures such as internal exposures, and a larger number of individuals/patients) in the future.

Calculation of Route Doses for Korean-based International Airline Routes using CARI-6 and Estimation of Aircrew Exposure (CARI-6를 이용한 국제선 노선별 선량 및 항공승무원의 피폭선량 평가)

  • Hong, J.H.;Kwon, J.W.;Jung, J.H.;Lee, J.K.
    • Journal of Radiation Protection and Research
    • /
    • v.29 no.2
    • /
    • pp.141-150
    • /
    • 2004
  • Dose rate characteristics of cosmic radiation field at flight altitudes were analyzed and the route doses to the personnels on board due to cosmic-ray were calculated for Korean-based commercial international airline routes using CARI-6. Annual individual doses to aircrew and the collective effective dose of passengers were estimated by applying the calculated route doses to the flight schedules of aircrew and the air travel statistics of Korea. The result shows that the annual doses to aircrew, around 2.62 mSv, exceed the annual dose limit of public and are comparable to doses of the group of workers occupationally exposed. Therefore it is necessary to consider the frequent flyers as well as the aircrew as the occupational exposure group. The annual collective dose to 11 million Korean passengers in 2001 appeared to be 136 man-Sv. The results should be modified when the dose rates of cosmic radiation at high altitude are revised by taking into account the changes in the radiation weighting factors for protons and neutrons as given in ICRP 92.