• Title/Summary/Keyword: neutron calibration fields

Search Result 9, Processing Time 0.026 seconds

CHARACTERISTICS OF THE KAERI NEUTRON REFERENCE FIELDS FOR THE CALIBRATION OF NEUTRON MONITORING INSTRUMENTS

  • Kim, Bong-Hwan;Kim, Jang-Lyul;Chang, Si-Young;Cho, Gyu-Seong
    • Journal of Radiation Protection and Research
    • /
    • v.26 no.3
    • /
    • pp.243-248
    • /
    • 2001
  • Neutron reference fields of Korea Atomic Energy Research Institute (KAERI) for calibrating neutron measuring devices to be used in radiation workplace monitoring consist of two kinds of neutron spectra, the direct and the scattered neutron fields, which are produced by using radionuclide neutron sources, 252Cf and 241AmBe sources. Necessary parameters for calibration such as the anisotropy factor of each neutron source and the room-scattered fraction of some neutron surveymeters in the KAERI calibration facility were determined by calculation or measurement. Spectral measurement of scattered neutron fields were performed at each reference calibration point using a Bonner Multi-sphere Spectrometer (BMS) and the dosimetric quantities for calibration also estimated from the neutron energy spectra which were unfolded using the BUNKI code.

  • PDF

Determination of Microdosimetric Quantities of Several Neutron Calibration Fields at KAERI

  • Kim, B.H.;Kim, J.S.;Kim, J.L.;Chang, S.Y.;Cho, G.;McDonald, J.C.
    • Journal of Radiation Protection and Research
    • /
    • v.28 no.4
    • /
    • pp.327-335
    • /
    • 2003
  • The commercially available neutron survey meter, the REM500, which uses a tissue equivalent proportional counter (TEPC) and the self-constructed TEPC were used to determine the microdosimetric quantities of several neutron calibration fields at Korea Atomic Energy Research Institute (KAERI). Microdosimetric spectra, absorbed dose, dose equivalent as well as quality factor were derived and compared with several neutron fields which were produced by using the shadow objects to make neutron scattered and being used as a kind of realistic neutron calibration fields at KAERI. The response of REM500 as a function of mean energy was evaluated with these neutron fields using the counts measured and the predetermined reference value. The response of the self-made TEPC and the REM500 was compared using one of the neutron calibration filelds of a $^{252}Cf$ source. The reference quantities of scattered neutron calibration fields were determined using a Bonner Sphere (BS). The value of frequency-mean lineal energy, dose-mean lineal energy and quality factor of two $^{252}Cf$ sources (unmoderated and $D_2O$ moderated) were determined to check the differences in the reference neutron fields between KAERI and Pacific Northwest National Laboratory (PNNL, USA) and the results were in good agreement within 1%. It means that there is no big difference in dosimetric quantifies of neutron calibration fields of two laboratories.

Development of the Graphite-Moderated Neutron Calibration Fields Using 241Am-Be Sources in JAEA-FRS

  • Nishino, Sho;Tanimura, Yoshihiko;Ebata, Yoshiaki;Yoshizawa, Michio
    • Journal of Radiation Protection and Research
    • /
    • v.41 no.3
    • /
    • pp.211-215
    • /
    • 2016
  • Background: The moderated neutron calibration fields using $^{241}Am$-Be sources and a graphite moderator have been constructed at the Facility of Radiation Standard (FRS) in the Japan Atomic Energy Agency (JAEA). Materials and Methods: The neutron spectra of the fields were evaluated by the Monte-Carlo calculations and measurements using the Bonner Multi-sphere Spectrometer. Results and Discussion: The fields have continuous neutron spectra from several MeV to thermal neutron energy, with fluence-averaged energies of 0.84 MeV and 0.60 MeV. Reference values of fluence rates and ambient/personal dose equivalent rates were determined from neutron spectra by measurements. Conclusion: Currently, the fields are available for calibration or performance test of neutron measuring instruments.

A REVIEW OF NEUTRON SCATTERING CORRECTION FOR THE CALIBRATION OF NEUTRON SURVEY METERS USING THE SHADOW CONE METHOD

  • KIM, SANG IN;KIM, BONG HWAN;KIM, JANG LYUL;LEE, JUNG IL
    • Nuclear Engineering and Technology
    • /
    • v.47 no.7
    • /
    • pp.939-944
    • /
    • 2015
  • The calibration methods of neutron-measuring devices such as the neutron survey meter have advantages and disadvantages. To compare the calibration factors obtained by the shadow cone method and semi-empirical method, 10 neutron survey meters of five different types were used in this study. This experiment was performed at the Korea Atomic Energy Research Institute (KAERI; Daejeon, South Korea), and the calibration neutron fields were constructed using a $^{252}Californium$ ($^{252}Cf$) neutron source, which was positioned in the center of the neutron irradiation room. The neutron spectra of the calibration neutron fields were measured by a europium-activated lithium iodide scintillator in combination with KAERI's Bonner sphere system. When the shadow cone method was used, 10 single moderator-based survey meters exhibited a smaller calibration factor by as much as 3.1-9.3% than that of the semi-empirical method. This finding indicates that neutron survey meters underestimated the scattered neutrons and attenuated neutrons (i.e., the total scatter corrections). This underestimation of the calibration factor was attributed to the fact that single moderator-based survey meters have an under-ambient dose equivalent response in the thermal or thermal-dominant neutron field. As a result, when the shadow cone method is used for a single moderator-based survey meter, an additional correction and the International Organization for Standardization standard 8529-2 for room-scattered neutrons should be considered.

Standard Neutron Irradiation Facility for Calibration of Radiation Protection Instruments by Radioactive Neutron Sources (방사성 중성자선원에 의한 방사선방어측정기의 교정을 위한 표준 중성자 조사장치 연구)

  • Choi, Kil-Oung;Lee, Kyung-Ju;Hwang, Sun-Tae
    • Journal of Radiation Protection and Research
    • /
    • v.14 no.1
    • /
    • pp.66-70
    • /
    • 1989
  • In routine testing, the radioactive neutron sources are particularly suitable for producing standard. neutron fields. The ISO TC-85 has proposed neutron reference radiation for the calibration of neutron measuring devices used for radiation protection purposes. Radiation laboratory of KSRI has installed a standard irradiation facility using $^{252}Cf$ and $^{241}Am-Be$ sources for calibrating personal dosimeters according to the recommendations given in ISO TC-85. In this study, correction factors for calibration related to neutron scattering and anisotropy are obtained by experiments with commercial rem meter for demonstration purposes.

  • PDF

SPECTRUM WEIGHTED RESPONSES OF SEVERAL DETECTORS IN MIXED FIELDS OF FAST AND THERMAL NEUTRONS

  • Kim, Sang In;Chang, Insu;Kim, Bong Hwan;Kim, Jang Lyul;Lee, Jung Il
    • Nuclear Engineering and Technology
    • /
    • v.46 no.2
    • /
    • pp.273-280
    • /
    • 2014
  • The spectrum weighted responses of various detectors were calculated to provide guidance on the proper selection and use of survey instruments on the basis of their energy response characteristics on the neutron fields. To yield the spectrum weighted response, the detector response functions of 17 neutron-measuring devices were numerically folded with each of the produced calibration neutron spectra through the in-house developed software 'K-SWR'. The detectors' response functions were taken from the IAEA Technical Reports Series No. 403 (TRS-403). The reference neutron fields of 21 kinds with 2 spectra groups with different proportions of thermal and fast neutrons have been produced using neutrons from the $^{241}Am$-Be sources held in a graphite pile, a bare $^{241}Am$-Be source, and a DT neutron generator. Fluence-average energy ($E_{ave}$) varied from 3.8 MeV to 16.9 MeV, and the ambient-dose-equivalent rate [$H^*(10)/h$] varied from 0.99 to 16.5 mSv/h.

Investigation of Response of Several Neutron Surveymeters by a DT Neutron Generator (DT 중성자 발생기에 의한 중성자 검출기 반응도 조사)

  • Kim, Sang-In;Jang, In-Su;Kim, Jang-Lyul;Lee, Jung-Il;Kim, Bong-Hwan
    • Journal of Radiation Protection and Research
    • /
    • v.37 no.1
    • /
    • pp.35-40
    • /
    • 2012
  • Several neutron measuring devices were tested under the neutron fields characterized with two distinct kinds of thermal and fast neutron spectrum. These neutron fields were constructed by the mixing of both thermal neutron fields and fast neutron fields. The thermal neutron field was constructed using by a graphite pile with eight AmBe neutron sources. The fast neutron field of 14 MeV was made by a DT neutron generator. In order to change the fraction of fast neutron fluence rate in each neutron fields, a neutron generator was placed in the thermal neutron field at 50 cm and 150 cm from the reference position. The polyethylene neutron collimator was used to make moderated 14 MeV neutron field. These neutron spectra were measured by using a Bonner sphere system with an LiI scintillator, and dosimetric quantities delivered to neutron surveymeters were determined from these measurement results.

Dose Evaluation of Neutron within Containment Building of a CE type Nuclear Power Plant (CE형 원전의 격납건물내 중성자선량 평가)

  • Kim Tae Wook;Han Jae Mun;Kim Kyung Doek;Yun Cheol Whan;Suh Jang Soo;Kim Young Jae
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.3 no.1
    • /
    • pp.23-30
    • /
    • 2005
  • From measured results of the neutron fields at some principal places within the containment building in a CE type nuclear power plant in operation, the radiation exposure of a worker to the neutron at there was evaluated and the equivalent dose reflecting new recommendation (ICRP 60) was compared with that doing the old one (ICRP 26). The measured neutron field was also compared with calibration neutron field. From the analysis, the following conclusion was obtained: the average neutron radiation weighting factor according to new recommendation is 2.41 to 2.71 times higher than the old one. The average neutorn radiation weighting factor at the measured place was similar to that at calibration neutron field. The average neutron energy at measured place was between 42 and 158 keV and higher than that of calibration field of 500 keV. So, the measured equivalent dose in nuclear power plant could be overestimated compared to the real equivalent dose.

  • PDF

An Analysis on Response Characteristics of a Dual Neutron Logging using Monte Carlo Simulation (Monte Carlo 모델링을 이용한 이중 중성자검층 반응 특성 분석)

  • Won, Byeongho;Hwang, Seho;Shin, Jehyun
    • The Journal of Engineering Geology
    • /
    • v.27 no.4
    • /
    • pp.429-438
    • /
    • 2017
  • Monte Carlo N-Particle (MCNP) modeling algorithm based on the Monte Carlo method was used to perform the simulation of neutron logging in order to increase the reliability and utilization of neutron logs applied in geological and resource engineering fields. To perform the simulation using MCNP, we used a realistic three-dimensional configuration of neutron sonde and formation. Validation of the modeling was confirmed by comparing the calibration curves of sonde manufacture with those calculated by MCNP modeling. After the validation, lithology effects, pore fluid effects, borehole diameter change, casing effect, and effects of borehole water level were investigated through modeling experiments. Numerical tests indicate that changes in neutron count ratio according to the lithology were quantitatively understood. In case of a borehole with a diameter of 3 inches, ratio of counting rates was higher than expected to be interpreted as borehole fluid has small effects on neutron logging. Effect of casing was also small in general, particular when porosity increases. Since modeling results above the groundwater level showed a tendency opposite to those below the groundwater level, neutron logs can be used to detect groundwater level. The modeling results simulated in this study for various borehole environments are expected to be used for data processing and interpretation of neutron log.