• 제목/요약/키워드: neutral voltage compensation

검색결과 36건 처리시간 0.024초

소형 BLDC 전동기 센서리스 드라이브의 단상 역기전력과 중성점을 이용한 제어기법 연구 (A Study on a Control Method for Small BLDC Motor Sensorless Drive with the Single Phase BEMF and the Neutral Point)

  • 조준우;황돈하;황영기;정태욱
    • 조명전기설비학회논문지
    • /
    • 제28권9호
    • /
    • pp.1-7
    • /
    • 2014
  • Brushless Direct Current(BLDC) Motor is essential to measure a rotor position because of that this motor type needs to synchronize the rotor's position and changeover phase current instead of a brush and commutator used on the existing dc motor. Recently, many researches have studied on sensorless control drive for BLDC motor. The conventional control methods are a compensation value dq, Kalman filter, Fuzzy logic, Neurons neural network, and the like. These methods has difficulties of detecting BEMF accurately at low speed because of low BEMF voltage and switching noise. And also, the operation is long and complex. So, it is required a high-performance microprocessor. Therefore, it is not suitable for a small BLDC motor sensorless drive. This paper presents control methods suitable for economic small BLDC motor sensorless drive which are an improved design of the BEMF detection circuit, simplifying a complex algorithm and computation time reduction. The improved motor sensorless drive is verified stability and validity through being designed, manufactured and analyzed.

해상풍력단지에서의 PMSG 풍력발전기를 활용한 계통연계점 불평형 전원 보상 (Compensation of Unbalanced PCC Voltage in an Off-shore Wind Farm of PMSG Type Turbines)

  • 강자윤;한대수;서용석;정병창;김정중;박종형;최영준
    • 전력전자학회논문지
    • /
    • 제20권1호
    • /
    • pp.1-10
    • /
    • 2015
  • This paper proposes a control algorithm for permanent magnet synchronous generators with a back-to-back three-level neutral-point clamped voltage source converter in a medium-voltage off-shore wind power system under unbalanced grid conditions. Specifically, the proposed control algorithm compensates for unbalanced grid voltage at the PCC (Point of Common Coupling) in a collector bus of an off-shore wind power system. This control algorithm has been formulated based on symmetrical components in positive and negative synchronous rotating reference frames under generalized unbalanced operating conditions. Instantaneous active and reactive power is described in terms of symmetrical components of measured grid input voltages and currents. Negative sequential component of AC input current is injected into the PCC in the proposed control strategy. The amplitude of negative sequential component is calculated to minimize the negative sequential component of grid voltage under the limitation of current capability in a voltage source converter. The proposed control algorithm enables the provision of balanced voltage at the PCC resulting in the high quality generated power from off-shore wind power systems under unbalanced network conditions.

Compensation of Unbalanced PCC Voltage in Off-shore Wind Farms of PMSG Type Turbine

  • Kang, Jayoon;Han, Daesu;Suh, Yongsug;Jung, Byoungchang;Kim, Jeongjoong;Park, Jonghyung;Choi, Youngjoon
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2014년도 전력전자학술대회 논문집
    • /
    • pp.215-216
    • /
    • 2014
  • This paper proposes a control algorithm for permanent magnet synchronous generator with a back-to-back three-level neutral-point clamped voltage source converter in a medium-voltage offshore wind power system under unbalanced grid conditions. The proposed control algorithm particularly compensates for the unbalanced grid voltage at the point of common coupling in a collector bus of offshore wind power system. This control algorithm has been formulated based on the symmetrical components in positive and negative rotating synchronous reference frames under generalized unbalanced operating conditions. Instantaneous active and reactive power are described in terms of symmetrical components of measured grid input voltages and currents. Negative sequential component of ac input current is injected to the point of common coupling in the proposed control strategy. The amplitude of negative sequential component is calculated to minimize the negative sequential component of grid voltage under the limitation of current capability in a voltage source converter. The proposed control algorithm makes it possible to provide a balanced voltage at the point of common coupling resulting in the generated power of high quality from offshore wind power system under unbalanced network conditions.

  • PDF

3-레벨 NPC 인버터의 전압 불균형 시 출력 상전류 보상기법 (Compensation method of output phase current when the voltage unbalance for 3-level NPC Inverter)

  • 이춘복;현승욱;홍석진;김영렬;원충연
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2014년도 추계학술대회 논문집
    • /
    • pp.187-188
    • /
    • 2014
  • 본 논문에서는 3-레벨 NPC(Neutral Point Clamped) 인버터에서 상단 커패시터 전압과 하단 커패시터의 전압의 불균형 시 나타나는 출력 상전류 왜곡에 대한 보상기법에 대하여 제안한다. 스위칭 기법은 SVPWM(Space Vector Pulse Width Modulation)을 사용하였고 상단 커패시터 전압과 하단 커패시터 전압의 불균형이 DC-Link 전압의 0% 15% 35%일 때의 보상 전과 보상 후를 비교 분석 하여 시뮬레이션으로 출력 상전류 보상기법을 검증하였다.

  • PDF

Eliminating the Third Harmonic Effect for Six Phase Permanent Magnet Synchronous Generators in One Phase Open Mode

  • Liu, Jian;Yang, Gui-Jie;Li, Yong;Gao, Hong-Wei;Su, Jian-Yong
    • Journal of Power Electronics
    • /
    • 제14권1호
    • /
    • pp.92-104
    • /
    • 2014
  • To insure stable operation and eliminate twice torque ripple, a topology for a six phase permanent magnet synchronous generator (SP-PMSG) with a neutral point connected together was analyzed in this paper. By adopting an extended transformation matrix, the mathematic model of the space vector control was established. The voltage and torque equations were deduced while considering the third harmonic flux and inductance. In addition, the suppression third harmonic method and the closed loop control strategy were proposed. A comparison analysis indicates that the cooper loss minimum method and the current magnitude minimum method can meet different application requirements. The voltage compensation amount for each of the methods was deduced which also takes into account the third harmonic effect. A simulation and experimental result comparison validates the consistency through theoretical derivation. It can be seen that all of the two control strategies can meet the requirements of post-fault.

컴퓨터부하의 직렬 동조필터 적용 및 평가에 관한 연구 (A Study on the Series Resonant Filler Application and Evaluation for Personal Computer Loads)

  • 김경철;강윤모;이일무;송영주
    • 조명전기설비학회논문지
    • /
    • 제17권3호
    • /
    • pp.40-48
    • /
    • 2003
  • 컴퓨터 부하는 현대사회 전반에 걸쳐 널리 사용되고 있다. 개인용 컴퓨터의 스위칭 모드 전원공급 장치는 고조파 전류를 발생시키는 주된 발생원이다. 고조파 전류는 전압파형 왜곡, 과다한 중성선 전류, 측정오차, 컴퓨터 일시 정지등 많은 고조파 장해를 일으킬 수 있다. 본 논문의 목적은 단상 개인용 컴퓨터 부하의 고조파 해석용 등가회로 모델링과 고조파 전류를 저감하기 위한 상품화된 직렬 동조 필터를 국제 고조파 관리 기준인 IEEE 519-1992와 IEC 1000-3-2를 근거로 평가하는데 있다.