• Title/Summary/Keyword: neuro-imaging

Search Result 73, Processing Time 0.023 seconds

Real-Time Temporal Dynamics of Bicistronic Expression Mediated by Internal Ribosome Entry Site and 2A Cleaving Sequence

  • Lee, Soomin;Kim, Jeong-Ah;Kim, Hee-Dae;Chung, Sooyoung;Kim, Kyungjin;Choe, Han Kyoung
    • Molecules and Cells
    • /
    • v.42 no.5
    • /
    • pp.418-425
    • /
    • 2019
  • Multicistronic elements, such as the internal ribosome entry site (IRES) and 2A-like cleavage sequence, serve crucial roles in the eukaryotic ectopic expression of exogenous genes. For utilization of multicistronic elements, the cleavage efficiency and order of elements in multicistronic vectors have been investigated; however, the dynamics of multicistronic element-mediated expression remains unclear. Here, we investigated the dynamics of encephalomyocarditis virus (EMCV) IRES- and porcine teschovirus-1 2A (p2A)-mediated expression. By utilizing real-time fluorescent imaging at a minute-level resolution, we monitored the expression of fluorescent reporters bridged by either EMCV IRES or p2A in two independent cultured cell lines, HEK293 and Neuro2a. We observed significant correlations for the two fluorescent reporters in both multicistronic elements, with a higher correlation coefficient for p2A in HEK293 but similar coefficients for IRES-mediated expression and p2A-mediated expression in Neuro2a. We further analyzed the causal relationship of multicistronic elements by convergent cross mapping (CCM). CCM revealed that in all four conditions examined, the expression of the preceding gene causally affected the dynamics of the subsequent gene. As with the cross correlation, the predictive skill of p2A was higher than that of IRES in HEK293, while the predictive skills of the two multicistronic elements were indistinguishable in Neuro2a. To summarize, we report a significant temporal correlation in both EMCV IRES- and p2A-mediated expression based on the simple bicistronic vector and real-time fluorescent monitoring. The current system also provides a valuable platform to examine the dynamic aspects of expression mediated by diverse multicistronic elements under various physiological conditions.

Conceptual Study of Brain Dedicated PET Improving Sensitivity

  • Shin, Han-Back;Choi, Yong;Huh, Yoonsuk;Jung, Jin Ho;Suh, Tae Suk
    • Progress in Medical Physics
    • /
    • v.27 no.4
    • /
    • pp.236-240
    • /
    • 2016
  • The purpose of this study is to propose a novel high sensitivity neuro-PET design. The improvement of sensitivity in neuro-PET is important because it can reduce scan time and/or radiation dose. In this study, we proposed a novel PET detector design that combined conical shape detector with cylindrical one to obtain high sensitivity. The sensitivity as a function of the oblique angle and the ratio of the conical to cylindrical portion was estimated to optimize the design of brain PET using Monte Carlo simulation tool, GATE. An axial sensitivity and misplacement rate by penetration of ${\gamma}$ rays were also estimated to evaluate the performance of the proposed PET. The sensitivity was improved by 36% at the center of axial FOV. This value was similar to the calculated value. The misplacement rate of conical shaped PET was about 5% higher than the conventional PET. The results of this study demonstrated the conical detector proposed in this study could provide subsequent improvement in sensitivity which could allow to design high sensitivity PET for brain imaging.

Non Small Cell Carcinoma Metastasis to Meningioma

  • Kim, Kyung Hyun;Hong, Eun Kyoung;Lee, Seung Hoon;Yoo, Heon
    • Journal of Korean Neurosurgical Society
    • /
    • v.53 no.1
    • /
    • pp.43-45
    • /
    • 2013
  • "Tumor-to-tumor" metastasis is a rare event; meningioma has been reported as the most common primary intracranial tumor to harbor cancer metastases. Several hypotheses have been previously proposed to explain this occurrence, but the exact mechanism by which these metastases develop into meningiomas is not yet understood. Magnetic resonance imaging and spectroscopy have been valuable diagnostic tools, but preoperative diagnosis of metastasis to meningioma remains highly difficult. We present a case report of a metastasis of non-small cell lung cancer into an intracranial meningioma.

5-Hydroxytryptamine 6 Receptor (5-HT6R)-Mediated Morphological Changes via RhoA-Dependent Pathways

  • Rahman, Md. Ataur;Kim, Hanna;Lee, Kang Ho;Yun, Hyung-Mun;Hong, Jung-Hwa;Kim, Youngjae;Choo, Hyunah;Park, Mikyoung;Rhim, Hyewhon
    • Molecules and Cells
    • /
    • v.40 no.7
    • /
    • pp.495-502
    • /
    • 2017
  • The $5-HT_6R$ has been considered as an attractive therapeutic target in the brain due to its exclusive expression in the brain. However, the mechanistic linkage between $5-HT_6Rs$ and brain functions remains poorly understood. Here, we examined the effects of $5-HT_6R$-mediated cell morphological changes using immunocytochemistry, Western blot, and live-cell imaging assays. Our results showed that the activation of $5-HT_6Rs$ caused morphological changes and increased cell surface area in HEK293 cells expressing $5-HT_6Rs$. Treatment with 5-HT specifically increased RhoA-GTP activity without affecting other Rho family proteins, such as Rac1 and Cdc42. Furthermore, live-cell imaging in hippocampal neurons revealed that activation of $5-HT_6Rs$ using a selective agonist, ST1936, increased the density and size of dendritic protrusions along with the activation of RhoA-GTP activity and that both effects were blocked by pretreatment with a selective $5-HT_6R$ antagonist, SB258585. Taken together, our results show that $5-HT_6R$ plays an important role in the regulation of cell morphology via a RhoA-dependent pathway in mammalian cell lines and primary neurons.

봉독약침을 이용한 반사성 교감신경 이영양증의 치료 -치료 전후 적외선체열영상 비교-

  • Lim, Myung-Jang;Kang, In;Song, Joo-Hyun;An, Keon-Sang;Jang, Hyoung-Seok
    • Journal of Pharmacopuncture
    • /
    • v.9 no.3 s.21
    • /
    • pp.139-145
    • /
    • 2006
  • Objectives : The purpose of this case in so report the patient with Reflex sympathetic dystrophy, who is improved by Bee venom. Method : We treated the patient with Bee venom who was suffering from Reflex sympathetic dystrophy, using Digital Infrared Thermographic Imaging and Verbal Numerical Rating Scale(VNRS) to evaluate the therapeutic effects. We compared the temperature of the patient body before and after treatment. Result and Conclusion : We found that Bee venom had excellent outcome to relieve pain, atrophy and ankle joint ROM, and that Bee venom also had clinical effect on hypothermia on the Digital Infrared Thermographic Imaging.

Diffusion-Weighted MRI for the Assessment of Molecular Prognostic Biomarkers in Breast Cancer

  • Mami Iima;Masako Kataoka;Maya Honda;Denis Le Bihan
    • Korean Journal of Radiology
    • /
    • v.25 no.7
    • /
    • pp.623-633
    • /
    • 2024
  • This study systematically reviewed the role of diffusion-weighted imaging (DWI) in the assessment of molecular prognostic biomarkers in breast cancer, focusing on the correlation of apparent diffusion coefficient (ADC) with hormone receptor status and prognostic biomarkers. Our meta-analysis includes data from 52 studies examining ADC values in relation to estrogen receptor (ER), progesterone receptor (PgR), human epidermal growth factor receptor 2 (HER2), and Ki-67 status. The results indicated significant differences in ADC values among different receptor statuses, with ER-positive, PgR-positive, HER2-negative, and Ki-67-positive tumors having lower ADC values compared to their negative counterparts. This study also highlights the potential of advanced DWI techniques such as intravoxel incoherent motion and non-Gaussian DWI to provide additional insights beyond ADC. Despite these promising findings, the high heterogeneity among the studies underscores the need for standardized DWI protocols to improve their clinical utility in breast cancer management.

A Review on Brain Study Methods in Elementary Science Education - A Focus on the fMRl Method - (초등 과학 교육에서 두뇌 연구 방법의 고찰 - fMRI 활용법을 중심으로 -)

  • Shin, Dong-Hoon;Kwon, Yong-Ju
    • Journal of Korean Elementary Science Education
    • /
    • v.26 no.1
    • /
    • pp.49-62
    • /
    • 2007
  • The higher cognitive functions of the human brain including teaming are hypothesized to be selectively distributed across large-scale neural networks interconnected to the cortical and subcortical areas. Recently, advances in functional imaging have made it possible to visualize the brain areas activated by certain cognitive activities in vivo. Neural substrates for teaming and motivation have also begun to be revealed. Functional magnetic resonance imaging (fMRI) provides a non-invasive indirect mapping of cerebral activity, based on the blood- oxygen level dependent (BOLD) contrast which is based on the localized hemodynamic changes following neural activities in certain areas of the brain. The fMRI method is now becoming an essential tool used to define the neuro-functional mechanisms of higher brain functions such as memory, language, attention, learning, plasticity and emotion. Further research in the field of education will accelerate the verification of the effects on loaming or help in the selection of model teaching strategies. Thus, the purpose of this study was to review brain study methods using fMRI in science education. In conclusion, a number of possible strategies using fMRI for the study of elementary science education were suggested.

  • PDF

Pontine Necrosis Related with Radiation Therapy, Complicated with Spontaneous Hemorrhage

  • Kim, Ha Min;Hong, Bo Young;Lee, Jong In;Kim, Joon Sung;Lim, Seong Hoon
    • Brain & NeuroRehabilitation
    • /
    • v.10 no.1
    • /
    • pp.1-6
    • /
    • 2017
  • The brain necrosis induced by radiation therapy (RT) is an uncommon pathology of brain. A case of spontaneous hemorrhage at necrotic brain is also rare. A 52-year-old man who had nasopharyngeal carcinoma and had been treated with RT, presented with gait disturbance, dizziness, ataxia, dysarthria, and dysphagia. Magnetic resonance imaging (MRI) demonstrated progressed radiation necrosis of pons, and spontaneous hemorrhage at the site of necrosis. The hematoma was diminished by conservative treatment. However, the patient's neurologic symptoms did not recover. Two years later, spontaneous bleeding recurred at necrotic brain. His neurologic symptoms worsened. One year later, his neurologic symptoms were more progressed. He showed severe dysphagia, profound weakness and respiratory failure. This case provides the description of relapsed spontaneous hemorrhage and medullary dysfunction caused by pontine necrosis and progressed post-radiation injury, complicated with hemorrhage, and urges caution in that the necrotic brain tissue may be vulnerable to bleeding.

Comparison of Vendor-Provided Volumetry Software and NeuroQuant Using 3D T1-Weighted Images in Subjects with Cognitive Impairment: How Large is the Inter-Method Discrepancy?

  • Chung, Jieun;Kim, Hayoung;Moon, Yeonsil;Moon, Won-Jin
    • Investigative Magnetic Resonance Imaging
    • /
    • v.24 no.2
    • /
    • pp.76-84
    • /
    • 2020
  • Background: Determination of inter-method differences between clinically available volumetry methods are essential for the clinical application of brain volumetry in a wider context. Purpose: The purpose of this study was to examine the inter-method reliability and differences between the Siemens morphometry (SM) software and the NeuroQuant (NQ) software. Materials and Methods: MR images of 86 subjects with subjective or objective cognitive impairment were included in this retrospective study. For this study, 3D T1 volume images were obtained in all subjects using a 3T MR scanner (Skyra 3T, Siemens). Volumetric analysis of the 3D T1 volume images was performed using SM and NQ. To analyze the inter-method difference, correlation, and reliability, we used the paired t-test, Bland-Altman plot, Pearson's correlation coefficient, intraclass correlation coefficient (ICC), and effect size (ES) using the MedCalc and SPSS software. Results: SM and NQ showed excellent reliability for cortical gray matter, cerebral white matter, and cerebrospinal fluid; and good reliability for intracranial volume, whole brain volume, both thalami, and both hippocampi. In contrast, poor reliability was observed for both basal ganglia including the caudate nucleus, putamen, and pallidum. Paired comparison revealed that while the mean volume of the right hippocampus was not different between the two software, the mean difference in the left hippocampus volume between the two methods was 0.17 ml (P < 0.001). The other brain regions showed significant differences in terms of measured volumes between the two software. Conclusion: SM and NQ provided good-to-excellent reliability in evaluating most brain structures, except for the basal ganglia in patients with cognitive impairment. Researchers and clinicians should be aware of the potential differences in the measured volumes when using these two different software interchangeably.