• Title/Summary/Keyword: network equipment

Search Result 1,255, Processing Time 0.027 seconds

The Study on the Application of the Safety Management Utilizing USN Using Smart Safety Equipment to Reduce Falling Accident on Construction Sites (건설현장의 추락재해 감소를 위한 스마트 안전장비를 활용한 USN 활용 안전관리의 적용에 관한 연구)

  • Nam, Wook Jin
    • Journal of the Korean Society of Safety
    • /
    • v.35 no.6
    • /
    • pp.46-53
    • /
    • 2020
  • The domestic construction industry is becoming larger, high-rise and specialized. However, safety consciousness is still staying in low levels and falling accidents are apt to rise compared to other industries. So, the new way of safety management is required for reducing of the construction falling accidents. In this paper, we evaluate appropriateness of safety management on construction sites utilizing USN using smart safery equipment. Thus, we calculate loss costs of falling accidents considering accident rates and costs of the USN using smart safery equipment installation then compare both calculated costs. This research aims to propose the method for reduction of construction accidents in addition to conventional safety control methods by analyzing the propriety of applying USN using smart safery equipment on construction sites.

End-to-End Telecom Billing (완전한 통신사용 정보체계)

  • Ryu, Jeong-Mook
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2001.04b
    • /
    • pp.1137-1140
    • /
    • 2001
  • This thesis defines an end-to-end billing process model. The processes in the model can be mapped to the TMN(Telecommunications Management Network) model which is based on an international telecommunications management standard. We have identified two interfaces in this billing process model. Part 1 of this thesis provides a protocol-independent design of the UAI(Usage Accounting interface) between the service provider and the network provider. Part 2 of this thesis provides information modeling of the UMI(Usage Metering Interface) between the network provider and the equipment provider. This interface is applied to the B-ICI(Broadband ISDN Inter-Carrier Interface) environment.

  • PDF

The Activating Plan of Domestic Super-Highway Information Network Equipment Industry using Competitive Strategy Model (경쟁 전략 모형을 활용한 국내 초고속 정보통신 장비 산업 활성화 방안)

  • Ryu, Kyung-Suk;Park, Joo-Seok;Yun, Byung-Nam;Lee, Han-Gyu;Lee, Kwang-Jae
    • Information Systems Review
    • /
    • v.4 no.2
    • /
    • pp.323-341
    • /
    • 2002
  • Due to the development of information technology, IT industry has become the core factor of a country competence. So we recognized the importance of information network technology as a basis of IT industry. The infrastructure and service in domestic super-highway information networks show the rapid growth both in quantity and quality because of the government programs. However, foreign information network equipment companies have most of the domestic market-share and have controlled core part of the industry, thus national companies are having a difficulty in penetrating the industry market. In this paper, we will analyze domestic super-highway information network equipment industry and make its activating plan using competitive strategy model.

A Study on Application Plan LTE Wireless Network in the Container Terminal Yard (컨테이너터미널 장치장에서 무선네트워크 LTE 적용방안에 관한 연구)

  • Cha, Sang-Hyun;Noh, Chang-Kyun
    • Journal of Navigation and Port Research
    • /
    • v.40 no.1
    • /
    • pp.43-50
    • /
    • 2016
  • Amid of the logistics hub center competition is going to intensifying between the world major port, it is essential to pre-occupied the base in the logistics hub world take advantage of advanced technology of logistics equipment than other ports. In existing container terminal, when container moves the terminal use the omnidirectional and directional antenna in order to exchange data information on the basis of 802.11 wireless network system. Case of loading height of exceeding, the blind sport will occur and a limited frequency channel can't help using in the area. A limited frequency channel usage and nested areas happen to use the closed terminal, it has a great influence to operate the terminal working. In this paper, LTE network is configured provided by the specified company ('L' Corp,.Ltd) and terminal data extracted through LBO (Local Breakout) in the cell site which is configured directly with container terminal operation server. Using this method, container terminal yard equipment operate without overlapping arises with uninterrupted data presented for ways to efficiently. I would suggest both the existing wireless AP LAN configuration of container terminal and new LTE system and applied to the real yard operating devices situations. Through these methods presented comparative the existing network traffic with new constructed LTE configuration. I admired to suggest that wireless network LTE introduction is fundamental factors to get rid of the blind spot, the problem of limited frequency channel and overlapping arises. These essential points can be a continual improving terminal services and more efficient terminal operational management.

A Study on Design and Operation Performance of Automatic Fire Detection Equipment (P-type One-class Receiver) by Bidirectional Communication (양방향 통신이 가능한 자동화재탐지설비(P형 1급 수신기)의 설계 및 동작특성에 관한 연구)

  • Lee, Bong-Seob;Kwak, Dong-Kurl;Jung, Do-Young;Cheon, Dong-Jin
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.2
    • /
    • pp.347-353
    • /
    • 2012
  • In this paper, authors will develop the quick and precise remote controller of automatic fire detection equipment (P-type one-class receiver) based on information communication technology (IT). The remote controller detects the fire and disaster in the building automatically and quickly and then activates the facilities to extinguish the fire and disaster, monitoring such situation in a real time through wire-wireless communication network. The proposed remote controller is applied a programmable logic device (PLD) micom. of one-chip type which is small size and lightweight and also has highly sensitive-precise reliabilities. The one-chip type PLD micom. analyzes digital signals from sensors, then activates fire extinguishing facilities for alarm and rapid suppression in a case of fire and disaster. The detected data is also transferred to a remote situation room through wire-wireless network of RS232c and bluetooth communication, and then the situation room sends an emergency alarm signal. The automatic fire detection equipment (AFDE) based on IT will minimize the life and wealth loss while prevents fire and disaster.

Development of PLC Communication Line Test Simulator (PLC 통신 선로 시험 시뮬레이터 개발)

  • ku, Jayl
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.54 no.4
    • /
    • pp.122-128
    • /
    • 2017
  • In order to simplify the wiring of construction heavy equipment, researches on PLC(Power Line Communication)-CAN(Controller Area Network) communication module are actively proceeding. Even if a PLC-CAN communication module is developed, a simulator capable of judging whether the PLC-CAN communication module is operating normally is needed. In this paper, we designed and developed a simulator that can measure the status of PLC-CAN communication module. We analyzed the characteristics of the power line communication frequency band by analyzing the characteristics of the power line and compared the noise characteristics with the passenger car in order to characterize the heavy equipment noise.

Implementation and Test of GPS Jamming Monitoring Equipment (GPS 교란 감시 장치 구현 및 시험)

  • Joo, Inone;Lee, Jeom Hun;Lee, Sanguk;Kim, Jaehoon
    • Journal of Satellite, Information and Communications
    • /
    • v.8 no.4
    • /
    • pp.95-99
    • /
    • 2013
  • GPS service is generally being used in the navigation application such as the car navigation and the smart phone. Recently, GPS service continues to increase in the timing application such as the mobile telecommunication network, the smart grid, and the financial network. As GPS signals are sensitive to GPS jamming, it should be monitored and protected. In oder to prevent and minimize the damage caused by GPS jamming, many countries are developing and operating GPS jamming monitoring system. This paper presents the implementation and the test results of the GPS jamming equipment which provides the detection, the direction finding and the location of GPS jamming.

Developing the Measurement System with Establishing the PHY Performance of Best Proper Cable Modem (최적의 케이블 모뎀 PHY 성능 구현 및 케이블 망 측정 시스템 개발)

  • Lee, Kyoung-Moon;Ko, Jae-Pyung;Lee, Jang-Myung
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.14 no.2
    • /
    • pp.205-211
    • /
    • 2008
  • This paper describes the method aimed at establishing the equipment measuring the parameter of Cable Network by Best proper Cable Modem and PDA through RS232 interface. In this paper, we propose our creative experimental configuration and develope the Cable Modem (DOCSIS 2.0) superior more performing than the referred Cable Modem (DOCSIS 1.0, 1.1) and the measuring equipment of HFC network compositing of Cable Modem and PDA through RS232 interface. This equipment analyzes Upstream (U/S) and Downstream (D/S) Signal quality and generates the signal of Upstream by CW signal. The paper also provides the experimental results to check the Best Proper Cable Modem and the displayed screen for parameters for SNR, BER and the demodulated IQ diagram of 256QAM through LCD of PDA. Henceforth, it'll be possible to support a variety of the functions for E-mail, Internet, the speed test of WEB connection and the transmission of the measured result real time by PDA.

Impedance Measurement and Matching Technique for Medium-Voltage Powerline Communication (고압전력선 통신을 위한 임피던스 측정 및 정합 방안 연구)

  • 이재조;유정훈;홍충선;이대영
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.53 no.5
    • /
    • pp.345-352
    • /
    • 2004
  • Currently, high data rate PLC(Power Line Communications), up to 100 Mbps, which use frequency bandwidth between 2 MHz and 30 MHz is investigated very hard, and commercial PLC modem for low voltage powerline network (indoor) is coming soon into communication market. For the purpose of developing a fit communication system which has little distortion of signal and attenuation, it is surely necessary to know about channel environments of powerline. Especially, the impedance measurement of the powerline and impedance matching are very important. As is known, since medium-voltage powerline (22.9 ㎸) is still working, it is not so simple to measure the powerline impedance. In our study, a portable impedance measurement equipment is developed. It consists of coupling capacitor, a drain coil and impedance matching transformer. The equipment is easily connected to medium voltage line and impedance of power line is measured using a network analyzer. Also, measurement results are used for impedance matching of PLC signal. In fact, matching transformer with several different impedances are used. The matching transformer is connected between coupling capacitor and signal port. In this paper, the developed portable impedance measurement equipment and impedance measurement results are presented. Also impedance matching technique using matching transformers will be explained. We showed the result of the improved performance by the impedance matching.

A Study on the Implementation of Ambulatory Monitoring System Using Wireless Data Communication Network (무선 데이터 통신망을 이용한 보행형 감시 시스템 개발에 관한 연구)

  • Go, Seong-Il;Kim, Yeong-Gil
    • Journal of Biomedical Engineering Research
    • /
    • v.20 no.1
    • /
    • pp.75-80
    • /
    • 1999
  • Since a Holter monitor records a patients' ECG when he is in motion, it can monitor complex heart disease effectively. But it can not handle a sudden heart disease because the diagnosis process will be done only after 24 hours. So in this study, a model of ambulatory monitoring system using wireless data communication network is proposed. And a mobile ECG equipment and a doctors' terminal are developed for the proposed system implementation. As a result, we can evaluate that the proposed ambulatory monitoring system is suitable for the management of ambulatory patients who may be at risk form sudden cardiac abnormalities.

  • PDF