• Title/Summary/Keyword: negative pressure

Search Result 1,280, Processing Time 0.026 seconds

Synthesis and Application of Photochromic Spiroxazine Dyes (광색변성 Spiroxazine계 색소의 합성과 응용)

  • 손세모
    • Journal of the Korean Graphic Arts Communication Society
    • /
    • v.10 no.1
    • /
    • pp.23-33
    • /
    • 1992
  • The negative pressure distribution curves of the exit of printing nip were obtained by the transducer type tackometer. As the results, found that the elasticity of rubber rollers and pastic viscosity affect to the maximum negative and positive pressure but, the gap of the printing nip didn`t affects to the tack values of ink and ink film thickness. Ink spritting is accured by negative pressure and inks viscoelasticity. And the tack value is affect by properties of the vehicle component in the inks.

  • PDF

Developing a Pressure Control Valve for Air Extraction Cupping Device (부항 장치용 압력 제어 밸브 개발)

  • Lee, Jae Yong;Shim, Dong Wook;An, Soo Kwang;Kim, Eun Seok;Lee, Byung Ryul;Yang, Gi Young
    • Korean Journal of Acupuncture
    • /
    • v.38 no.4
    • /
    • pp.308-316
    • /
    • 2021
  • Objectives : This study aimed to develop a cupping pressure control valve for limiting maximum negative pressure while achieving clinical therapeutic outcomes to minimize side effects induced by excessive negative pressure of air extraction cupping devices. Methods : To determine the clinical necessity and suitability of the cupping pressure control valve, this study was designed to measure the change in pressure with or without the valve using both a manual and an electric suction pump. Results : While the maximum pressure was limited by the pressure control valve, the pressure did not increase above a certain level regardless of the type of manual or electric pump. Conclusions : This study will contribute to the development of a safer and more effective base technology for cupping treatment in oriental medicine.

In vitro apical pressure created by 2 irrigation needles and a multisonic system in mandibular molars

  • Ronald Ordinola-Zapata;Joseph T. Crepps;Ana Arias;Fei Lin
    • Restorative Dentistry and Endodontics
    • /
    • v.46 no.1
    • /
    • pp.14.1-14.7
    • /
    • 2021
  • Objectives: The aim of this study was to evaluate the apical pressure generated by 2 endodontic irrigation needles and the GentleWave system in mandibular molars. Materials and Methods: The mesial and distal root canals of 12 mandibular molars were irrigated with a 30-gauge close-end needle or with a 30-gauge open-end needle. Procedures were performed in the mesial and distal canals. The GentleWave procedure and irrigation at 1 mm from the apex in the distal roots using an open-end needle were used, respectively, as negative and positive controls. The apical pressure was measured using a data acquisition pressure setup. Apical pressure exerted by the different needles in the 2 different canal types was statistically compared using 2-way analysis of variance. Results: Significant differences were found in the apical pressure for both needles and the canal type. The lowest values were obtained with close-end needles and in mesial canals. Negative apical pressure values were obtained using GentleWave. Conclusions: The needle and the canal type influenced the apical pressure. The GentleWave procedure produced negative apical pressure.

A Study on the direction for Facility Improvement of Nationally Designated Negative Pressure Isolation Ward through Post Occupancy Evaluation (거주 후 평가를 통한 국가지정 입원치료병상 시설 개선 방향 도출에 관한 연구)

  • Jeong, Dawoon;Kwon, Soonjung
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.27 no.3
    • /
    • pp.39-49
    • /
    • 2021
  • Purpose: The negative pressure isolation ward is a key facility in preparedness and response to infectious diseases. For the sustainable operation of the facility, appropriate facility improvement is required. The experience of medical staff responding to infectious diseases in the COVID-19 pandemic provides effective informations for facility planning. Methods: The post occupancy evaluation (POE) was conducted by interviewing medical staff who is working on Nationally designated negative pressure isolation ward in general hospital. Floor plan analysis was conducted before field surveys for identifying facility characteristic and spatial composition. After that, field surveys were conducted at 3 hospitals, and interviews and fieldwork were conducted together. Results: It is necessary to increase the standard size of ward area from 15m2 to 20m2. The size of the doffing room has to be planned for accommodation of two or more people. Equipment storage, clean storage and waste storage also should be properly planned. There were almost no problems with the circulation in the ward. There was not enough space for medical staff. Implications: For a sustainable and safe negative pressure isolation ward planning, it is necessary to exploit learning from the medical staffs who have many experiences of coping with infectious diseases.

A study on the Types of Urgent Isolation Ward (긴급치료격리병동의 평면유형)

  • Lee, Hyunjin;Kwon, Soonjung
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.28 no.4
    • /
    • pp.61-69
    • /
    • 2022
  • Purpose: In response to the rapid spread of COVID-19 in 2020, the government supported facilities and equipment through the 'Urgent Isolation Ward Expansion Project'. Design and remodeling of efficient negative pressure isolation facilities had to be done in a short period of time, and the performance gap between facilities was very large because the types of hospitals and wards of existing medical facilities were diverse. In order to secure the stability of isolation wards between medical facilities and reduce the facility gap, guidelines for planning isolation wards considering the diversity of each hospital should be appropriately presented. In consideration of these points, this study aims to provide basic data for future remodeling guidelines for each plan type of the negative pressure isolation ward first. Methods: We analyzed the plans before and after the change of 13 case hospitals that performed the urgent care bed expansion project for COVID-19 confirmed patients. Before the remodeling, the current status of the facility was analyzed according to the type of corridor, the location of the nursing station, and the location of the elevator. After remodeling, the flow of medical staff and patients, the flow of entry and exit of clean and contaminated items, and the space of negative pressure and non-negative pressure areas. Results: The ward type was divided into three types according to the corridor type and room arrangement: double loaded corridor type with two side wards, race track type with one side ward, and race track type with two side wards. Based on these three types, the standard floor plan type of the isolation ward was proposed in terms of the location of the elevator bank and Nurse station. Implications: When the existing general ward is converted into a negative pressure isolation ward, this study can be a basic data to present customized guidelines for each ward type.

A Study on the Room Conversion Type when Converting a Patient Bed-Room into a Negative Pressure Isolation Room - Focused on Nationally designated Isolation Wards and Urgent Isolation Wards (일반병실을 음압격리병실로 전환 시 병실 전환 방식에 관한 연구 - 국가지정입원치료병상과 긴급치료병상을 중심으로)

  • Kim, Jiyoon;Lee, Hyunjin;Kwon, Soonjung
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.29 no.4
    • /
    • pp.29-35
    • /
    • 2023
  • Purpose: The 2015 Middle East Respiratory Syndrome (MERS) outbreak and the recent COVID-19 pandemic have highlighted the lack of negative pressure isolation rooms and the fragility of the healthcare system. The need for healthcare facility transformation for respiratory infectious diseases has become more prominent due to COVID-19, and the purpose of this study is to provide a foundation for the rapid, economical, and safe construction of negative pressure isolation wards. Methods: This study analyzes the current status of hospitals that have been converted to negative pressure isolation rooms, and provides architectural plans and examples to provide a reference for bedroom change. Research data of this study have been obtained by analyzing the drawings of negative pressure isolation wards of nationally designated inpatient treatment beds and urgent isolation beds. In addition, the relevant literature of urgent isolation beds has been analyzed to derive bedroom change type. Result: In this study, a total of 21 isolation bed conversion methods have been presented. Implications: In order to change efficiently from a general ward to an isolation ward, it is necessary to consider the actual hospital's infectious disease transmission patterns and facility conditions.

A Peculiar Case of Ischemic Fasciitis Appeared on a Pressure Ulcer after 10 Days of Negative Pressure Wound Therapy

  • Recchi, Vania;Peltristo, Benedetta;Talevi, Davide;Scalise, Alessandro;Benedetto, Giovanni Di
    • Archives of Plastic Surgery
    • /
    • v.49 no.5
    • /
    • pp.608-610
    • /
    • 2022
  • In this article, we reported a single case of ischemic fasciitis in a young woman with a progressive immobilization due to a multifocal demyelinating disease of central nervous system, which appeared on an extensive pressure ulcer of the sacral region treated with 10 days of negative-pressure wound therapy (NPWT). Wound examination revealed a significant nontender brown neoformation (9 cm in length × 10 cm in width × 7 cm in height), fixed to the sacrum, presenting hard consistency, and grown in the central portion of the sacral pressure sore. The histologic examination showed central fibrinoid necrosis, and vascular and atypical fibroblastic proliferations, and a diagnosis of ischemic fasciitis was made. Ischemic fasciitis is a rare benign proliferation of atypical fibroblasts that occurs in physically weak patients with reduced mobility. In the literature, the relationship between the use of NPWT on pressure ulcers and the development of ischemic fasciitis is, to the best of our knowledge, not described yet.

Relation between Time Pressure, Discretionary Time and Subjective Well-Being of University Students (대학생의 시간압박감, 자유재량시간과 주관적 안녕감의 관계)

  • Yun, Jung;Kim, Jungsub
    • (The) Korean Journal of Educational Psychology
    • /
    • v.31 no.3
    • /
    • pp.389-408
    • /
    • 2017
  • The purpose of this study was to investigate the relationship of time pressure, discretionary time, and subjective well-being(SWB) of university students. In order to achieve it, 493 university students(220 male, 232 female) completed a set of questionnaires about time pressure, discretionary time, subjective well-being. The t-test, multiple regression analysis were performed to analyze the data. The results are as follows. First, There were significant differences among the positive emotion, the negative emotion and time pressure. However, there was no statistically significant difference between the satisfaction of life and discretionary time according to gender. Second, time pressure was negatively correlated with the satisfaction of life of university students but positively correlated with the negative emotion. The discretionary time was positively correlated with the satisfaction of life of university students but negatively correlated with the negative emotion. Time pressure and discretionary time were not correlated with the positive emotion. Finally time pressure significantly correlated with the satisfaction of life, the negative emotion. And It seems that time pressure had an especially strong effect on the negative emotion. Such results imply that time pressure is important for reducing university students's the negative emotion, a subfactor of subjective wellbeing.

A Dynamic Calibration Technique for Piezoelectric Sensors Using Negative Going Dynamic Pressure (부방향 동압력을 이용한 압전형 압력센서의 교정기법)

  • Kim, Eung-Su
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.12 no.4
    • /
    • pp.491-499
    • /
    • 2009
  • The determination of response characteristics for pressure sensors is routinely limited to static calibration against a deadweight pressure standard. The strength of this method is that the deadweight device is a primary standard used to generate precise pressure. Its weakness lies in the assumption that the static and dynamic responses of the sensor in question are equivalent. Differences in sensor response to static and dynamic events, however, can lead to serious measurement errors. Dynamic techniques are required to calibrate pressure sensors measuring dynamic events in milliseconds. In this paper, a dynamic calibration using negative going dynamic pressure is proposed to determine dynamic pressure response for piezoelectric sensors. Sensitivity and linearity of sensor by the dynamic calibration were compared with those by the static calibration. The uncertainty of calibration results and the goodness of fit test of linear regression analysis were presented. The results show that the dynamic calibration is applicable to determine dynamic pressure response for piezoelectric sensors.

CVT Power Transmitting Characteristics and Control Logics for Negative Torque (역방향 토크시 무단변속기 동력전달 특성과 제어로직)

  • 송한림;이희라;김현수
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.10 no.1
    • /
    • pp.255-264
    • /
    • 2002
  • In this paper, the power transmitting mechanism for negative torque of the metal V-belt (MVB) CVT were investigated by theoretically analyzing variation of band tension, block compression forces for each of the primary and secondary pulleys. An experimental study was performed to investigate the speed ratio - thrust characteristics for negative torque. The experimental results are in good acoordance with the theoretical results. CVT line pressure control logic was suggested for negative torque based the speed radio - negative torque - thrust characteristics and the thrust ratio curves. The results of this study can be used as basic design materials for developing the CVT control system for negative torque.