• Title/Summary/Keyword: needle tip

Search Result 160, Processing Time 0.023 seconds

Effect of Ambient Temperature on the AC Electrical Treeing Phenomena in an Epoxy/Layered Silicate Nanocomposite

  • Park, Jae-Jun
    • Transactions on Electrical and Electronic Materials
    • /
    • v.14 no.4
    • /
    • pp.221-224
    • /
    • 2013
  • Effects of ambient temperature on the ac electrical treeing and breakdown behaviors in an epoxy/layered silicate (1 wt%) were carried out in needle-plate electrode geometry. A layered silicate was exfoliated in an epoxy base resin,, using our ac electric field apparatus. To measure the treeing initiation and propagation, and the breakdown rate, constant alternating current (ac) of 10 kV (60 Hz) was applied to the specimen in a needle-plate electrode arrangement, at $30^{\circ}C$, $90^{\circ}C$ or $130^{\circ}C$ of insulating oil bath. At $30^{\circ}C$, the treeing initiation time and the breakdown time in the epoxy/layered silicate (1 wt%) system were 1.4 times higher than those of the neat epoxy resin. At $90^{\circ}C$ (lower than Tg), electrical treeing was initiated in 55 min, and propagated until 1,390 min at the speed of $0.35{\times}10^{-3}mm/min$, which was 4.4 times higher than that at $30^{\circ}C$; however, there was almost no further treeing propagation after 1,390 min. At $130^{\circ}C$ (higher than Tg), electrical treeing was initiated in 44 min, and propagated until 2,000 min at the speed of $0.96{\times}10^{-3}mm/min$. Typical branch type electrical treeing was obtained from the neat epoxy and epoxy/layered silicate at $30^{\circ}C$, while bush type treeing was observed out from the needle tip at $90^{\circ}C$ and $130^{\circ}C$.

Analysis of Intravascular Flow Patterns following Cervical Transforaminal Epidural Injection (경부 경추간공 경막외 차단술 시 혈관 내 조영에 대한 분석)

  • Hwang, Su Jin;Han, Kyung Ream;Kim, Sae Young;Kim, Nan Seol;Kim, Chan
    • The Korean Journal of Pain
    • /
    • v.22 no.1
    • /
    • pp.52-57
    • /
    • 2009
  • Background: Transforaminal epidural injection (TEI) may be useful to treat unilateral pain that has a dermatomal distribution. In this approach, the needle tip can be placed closer to the dorsal root ganglion and ventral aspect of the nerve root. However many studies have reported that serious complications following TEI occurred more frequently when it was conducted at the cervical level. One of the presumptive mechanisms of the complication is intravascular injection. Therefore this study was conducted to identify the incidence of complications in response to intravascular injections at cervical segments. Methods: This study included all patients, who visited our pain clinic and had radicular symptoms or herpes zoster associated pain. All procedures were conducted under fluoroscopic guidance with contrast enhancement by one of the authors. After the ideal needle position was confirmed by biplanar fluoroscopy, the blood aspiration through the needle hub was evaluated, and a 3 ml mixture of nonionic contrast (2 ml) with normal saline (1 ml) was injected at a rate of 0.3-0.5 ml/sec continuously under real time fluoroscopic visualization. We then classified the contrast spreading pattern as neural, simultaneous neural and vascular, or vascular. Results: A total 71 cervical TEIs were performed. In 26 cases (36.6%), the contrast only spread to the nerve sheath. However, 45 cases (63.4%) showed an intravascular spreading pattern, 37 (52.1%) of which showed a neural and vascular pattern and 8 (11.3%) of which showed only a vascular pattern. Conclusions: Approximately two thirds of the cases of cervical TEI were found to lead to intravascular spreading, which is much higher than the incidence reported in previous studies.

Discharge Characteristics between Needle and Plane Electrodes in Water under Impulse Voltages (임펄스전압에 의한 침 대 평판전극에서 수중방전특성)

  • Choi, Jong-Hyuk;Park, Geon-Hun;Lee, Bok-Hee
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.8
    • /
    • pp.67-74
    • /
    • 2008
  • In this paper we describe discharge characteristics between needle-to-plane electrodes in water in various conditions such as different impulse voltages, polarities and water resistivities. Streamer corona is initiated at the tip of needle electrode and propagates toward plane electrode, and it experiences the final jump across the test gap. The branched channels of streamer coronas for lower water resistivities are much thicker and brighter than those for higher water resistivities at the same level of applied voltage. The negative streamer coronas not only have more branches but also widely spread out compared to the positive streamer coronas. A number of pulse-like currents ranging from some hundreds mA to a few A after streamer corona onset were produced with discharge developments. The time-lags-to breakdown for the positive polarity were remarkably shorter than those for the negative polarity. The pre-breakdown energy supplied into the test gap was inversely proportional to water resistivity.

Characteristics of ionic Wind in a DC Corona Discharge in Needle-to-punched plate Geometry (침 대 중공평판전극에서 직류코로나 방전에 의한 이온풍 특성)

  • Lee, Bok-Hee;Kil, Hyeong-Joon;Eom, Ju-Hong;Ahn, Chang-Hwan
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.17 no.4
    • /
    • pp.74-80
    • /
    • 2003
  • Ionic wind is produced by a corona discharge when a DC high voltage is applied across the point-to-plane gap geometry. The corona discharge phenomena have been investigated in several beneficial application fields such as electrostatic cooling, ozone generation, electrostatic precipitation and electrostatic spraying. Recently ionic wind might be used in aerodynamic, for example, heat transfer, airflow modification, and etc. In this work, in order to analyze the control behavior of the velocity and amount of ionic wind produced by the positive DC corona discharges. The ionic wind velocity was measured as a function of the applied voltage, diameter of the punched hole on plate electrode and separation between the point-to-plate electrodes. As a results, the airflow is generated from the tip of needle to the plate electrode in the needle-to-punched-plate electrode systems. The ionic wind velocity is linearly increased with an increase in applied voltage and ranges from 1 to 3 m/sec at the locations of 100-200 mm from the punched-plate.

Measurement of S1 foramen depth for ultrasound-guided S1 transforaminal epidural injection

  • Ye Sull Kim;SeongOk Park;Chanhong Lee;Sang-Kyi Lee;A Ram Doo;Ji-Seon Son
    • The Korean Journal of Pain
    • /
    • v.36 no.1
    • /
    • pp.98-105
    • /
    • 2023
  • Background: Ultrasound-guided first sacral transforaminal epidural steroid injection (S1 TFESI) is a useful and easily applicable alternative to fluoroscopy or computed tomography (CT) in lumbosacral radiculopathy. When a needle approach is used, poor visualization of the needle tip reduces the accuracy of the procedure, increasing its difficulty. This study aimed to improve ultrasound-guided S1 TFESI by evaluating radiological S1 posterior foramen data obtained using three-dimensional CT (3D-CT). Methods: Axial 3D-CT images of the pelvis were retrospectively analyzed. The radiological measurements obtained from the images included 1st posterior sacral foramen depth (S1D, mm), 1st posterior sacral foramen width (S1W, mm), the angle of the 1st posterior sacral foramen (S1A, °), and 1st posterior sacral foramen distance (S1ds, mm). The relationship between the demographic factors and measured values were then analyzed. Results: A total of 632 patients (287 male and 345 female) were examined. The mean S1D values for males and females were 11.9 ± 1.9 mm and 10.6 ± 1.8 mm, respectively (P < 0.001); the mean S1A 28.2 ± 4.8° and 30.1 ± 4.9°, respectively (P < 0.001); and the mean S1ds, 24.1 ± 2.9 mm and 22.9 ± 2.6 mm, respectively (P < 0.001); however, the mean S1W values were not significantly different. Height was the only significant predictor of S1D (β = 0.318, P = 0.004). Conclusions: Ultrasound-guided S1 TFESI performance and safety may be improved with adjustment of needle insertion depth congruent with the patient's height.

Optimum Operating Conditions of a Vacuum Nozzle Seeder (진공노즐식 파종기의 최적 작동조건)

  • 민영봉;김성태;정태상
    • Journal of Biosystems Engineering
    • /
    • v.25 no.6
    • /
    • pp.463-470
    • /
    • 2000
  • For maximum seeding efficiency of a nozzle type seeder, the performance of the nozzle should be considered sufficiently. This study was carried out to investigate the optimum operating conditions of a seeder attached the vacuum nozzle which was modified syringe needle acting on the plug seedling tray and the seed plate. Such operating factors as the hole diameter of the nozzle (d), the distance from the nozzle tip to the bottom plate of seed hopper(D) the absorbing air pressure of the nozzle tip(P) the bounding height of seed from the vibrated bottom plate of seed hopper and the seeding speed were selected based on the weight of a grain of seed(W). The treated materials were pepper seed as the flat type, cucumber seed as the oval type and radish seed as the spherical type. The optimum operating conditions of the experimental seeder were revealed as follows: 1. The height of the seed bounding from the bottom plate of seed hopper and the distance from nozzle tip to bounded seed were 5 mm and 0.5 mm at all seeds. The hole diameter of the nozzle and the absorbing pressure for pepper seed, cucumber seed and radish seed was 0.45 mm, 0.65 mm. 0.65mm and 39.2 kPa, 88.3 kPa, 58.8 kPa, respectively. 2. The absorbing pressure P was represented as P=η.4W/$\pi$d$^2$ where η was 100. The seeding speed using a 128 cell tray was 2.4 cm/s which was same transfer as 2.5 trays per minute. 3. The maximum seeding rate in case of the pepper seed was 97% the cucumber seed was 95% and the radish seed was 100% under the optimum operating conditions of the seeder.

  • PDF

Discharge Characteristics near the tip of needle in water (수중에서 침전극 끝단의 방전특성)

  • Lee, Bok-Hee;Choi, Jong-Hyuk;Park, Geon-Hun;Jun, Byung-Wook;Kim, Hoe-Gu;Beak, Young-Hwan;Lee, Kyu-Sun
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2007.11a
    • /
    • pp.239-241
    • /
    • 2007
  • In this paper we describe streamer propagations characterizing underwater pre-breakdown and breakdown behaviour under impulse voltages. Streamer corona branches in lower resistivities are much thicker and brighter than those in higher resistivities. The negative streamer channels not only have more branches but also widely spread out than the positive streamer channels. The succession of streamer coronas during re-breakdown produces a stepwise propagation. The pre-breakdown currents consist of the conduction current and streamer corona current pulses.

  • PDF

Effect of Nozzle Material on Drop Size Distribution in Electrohydrodynamic Spraying (전기수력학적 분무에서 노즐재질이 입경분포에 미치는 영향)

  • 김명찬;이상용
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.26 no.10
    • /
    • pp.1451-1457
    • /
    • 2002
  • When an aqueous liquid such as water having high electric conductivity and high surface tension is discharged from a nozzle under a strong DC electric field, fine drops ranging from 30 to 450 microns can be obtained only through the spindle mode. In the present study, effects of the electric conductivity and the surface wettability of nozzle materials on formation of drops with this mode were investigated. For that, three nozzles with the same size but with different materials were prepared and tested; a stainless steel needle, and a plain and a metal (gold)-coated (except for the tip portion) silica needles. Uniform drops were obtained with the gold-coated silica nozzle over the wider range of the DC voltage input. That is, formation of the liquid cone and detachment of the liquid spindle (ligament) can be more stabilized and frequent with the needles having high electric conductivity but with low surface wettability at their tips.

ACCURATE SYNTHESIS OF SEEDLING SEPARATING-PLANTING MECHANISM OF RICE TRANSPLANTER

  • Hu, Hanxiang;Chen, Dejun;Wang, Changbing;Li, Zhenyong;Wu, Jienian;Xu, Jinda
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 1993.10a
    • /
    • pp.284-290
    • /
    • 1993
  • In order to improve the adaptability of rice transplanter to seeding with different length when transplanting multicropping rice in south China. The seedling separating planting mechanism is resynthesized in the paper. According to the agronomy requirements of seedling's transplanting, optimum motional path of the tip point of planting needle is obtained. by applying the established kinematic model of the separating planting mechanism, the relevant software is compiled. On the basis of the features of the problem, the constrained optimization method is utilized to solve the problem with 24 restrictions. Thus, the optimum structure parameters are obtained to satisfy the path points accurately.

  • PDF

Simulation of Fuel Injection System and Model of Spray Behavior in Liquefied Butane (액상부탄 분사시스템의 수치시뮬레이션 및 분무특성 예측)

  • Kim, J.H.;Koo, J.Y.
    • Journal of ILASS-Korea
    • /
    • v.3 no.2
    • /
    • pp.24-33
    • /
    • 1998
  • The characteristics of liquefied butane spray are expected to be different from conventional diesel fuel spray, because a kind of flash boiling spray is expected when the back pressure is below the saturation vapor pressure of the butane(0.23MPa at $25^{\circ}C$). An accumulator type pintle injector and its fuel delivery system has been simulated in ruder to give injection pressure, needle lift and rate of fuel injected. The governing equation were solved by finite difference metho. The injection duration was controlled by solenoid valve. Spray behaviors such as a transient spray tip penetration, spray angle and SMD were calculated based on the empirical correlations in case that the back pressure is both above the vapor pressure of the butane and below that of butane. When the back preassure is below the vapor pressure of the fuel, conventional correlation is modified to represent the effect of flash boiling.

  • PDF