• Title/Summary/Keyword: needle characteristics

Search Result 571, Processing Time 0.024 seconds

Fabrication and Characterization of Gas-liquid Hybrid Reactor Equipped with Atmospheric Pressure Plasma (기-액 하이브리드 대기압 플라즈마 반응기 제작 및 특성 분석)

  • Kwon, Heoung Su;Lee, Won Gyu
    • Korean Chemical Engineering Research
    • /
    • v.60 no.3
    • /
    • pp.452-458
    • /
    • 2022
  • Three types of gas-liquid hybrid horizontal, vertical and needle-to-cylinder plasma reactors were fabricated. Through these reactors, a high-efficiency, eco-friendly cleaning concept that generates reactive active species generated in atmospheric plasma discharge and gas-liquid activation reaction of cleaning components through the potential difference within the electrode was presented. As a result of comparing the efficiency for cleaning performance, the needle-to-cylinder type reactor had the best characteristics. Through this study, it was confirmed that the gas-liquid hybrid atmospheric pressure plasma reactor has the potential to be applied to ultra-precision cleaning processes such as semiconductor processes.

Usefulness of X-ray Guided Biopsy and Ultrasound Guided Biopsy in Breast Microcalcification Biopsy (유방 미세석회화 조직검사에서 X선 유도 하 조직검사와 초음파 유도 하 조직검사의 유용성)

  • Choi, Miseon;Song, Jongnam
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.3
    • /
    • pp.201-206
    • /
    • 2016
  • Social interest in breast cancer has increased. The most basic exams for diagnosis include breast X-ray and breast ultrasound. In particular, breast microcalcification requires histological diagnosis, and breast microcalcification biopsy is commonly performed. Therefore, this study aimed to analyze and assess X-ray guided biopsy (needle localized open biopsy) and ultrasound guided biopsy (sono guided core needle biopsy), which are basics in diagnosis of microcalcification. Targeting 241 cases in which magnification mammography was performed for patients who visited the hospital due to breast microcalcification, age distribution and the location of lesions were analyzed in X-ray guided biopsy and ultrasound guided biopsy. By classifying exams performed after magnification mammography, the frequencies of X-ray guided biopsy and ultrasound guided biopsy were analyzed, and malignant and benign results were confirmed. The results showed that 64 cases(26.6%) were X-ray guided biopsy, which was 5.4 times higher than 12 cases(4.9%) of ultrasound guided biopsy. Due to development of ultrasound equipments, stereotactic vacuum-assisted biopsy, etc. the methods of histological diagnosis of microcalcification have become diverse, but when considering characteristics and limitations of each exam, X-ray guided biopsy is thought to be most accurate and useful.

A Study on Nozzle Flow and Spray Characteristics of Piezo Injector for Next Generation High Response Injection (차세대 고응답 분사용 피에조 인젝터의 노즐유동 및 분무특성에 관한 연구)

  • Lee Jin-Wook;Min Kyoung-Doug
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.30 no.6 s.249
    • /
    • pp.553-559
    • /
    • 2006
  • Most diesel injector, which is currently used in high-pressure common rail fuel injection system of diesel engine, is driven by the solenoid coil energy for its needle movement. The main disadvantage of this solenoid-driven injector is a high power consumption, high power loss through solenoid coil and relatively fixed needle response's problem. In this study, a prototype piezo-driven injector, as a new injector mechanism driven by piezoelectric energy based on the concept of inverse piezo-electric effect, has been designed and fabricated to know the effect of piezo-driven injection processes on the diesel spray structure and internal nozzle flow. Firstly we investigated the spray characteristics in a constant volume chamber pressurized by nitrogen gas using the back diffusion light illumination method for high-speed temporal photography and also analyzed the inside nozzle flow by a fully transient simulation with cavitation model using VOF(volume of fraction) method. The numerical calculation has been performed to simulate the cavitating flow of 3-dimensional real size single hole nozzle along the injection duration. Results were compared between a conventional solenoid-driven injector and piezo-driven injector, both equipped with the same micro-sac multi-hole injection nozzle. The experimental results show that the piezo-driven injector has short injection delay and a faster spray development and produces higher injection velocity than the solenoid-driven injector. And the predicted simulation results with the degree of cavitation's generation inside nozzle for faster needle response In a piezo-driven injector were reflected to spray development in agreement with the experimental spray images.

Analysis of Hydraulic Characteristics of Two Solenoid-driven Injectors for CRDi System (2개 솔레노이드 구동방식별 CRDi용 인젝터의 유압 동특성 해석)

  • Lee, Jin-Wook;Lee, Jung-Hyup;Kim, Min-Sik
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.19 no.6
    • /
    • pp.140-147
    • /
    • 2011
  • The injection nozzle of an electro-hydraulic injector for the common rail Diesel fuel injection system is being opened and closed by movement of a injector's needle which is balanced by pressure at the nozzle seat and at the needle control chamber, at the opposite end of the needle. In this study, the slenoid actuator was considered as a prime movers in high pressure Diesel injector. Namely a solenoid-driven Diesel injector with different driving current types, as a general method driven by solenoid coil energy, has been applied with a purpose to develop the analysis model of the solenoid actuator to predict the dynamics characteristics of the hydraulic component (injector) by using the AMESim code. Aimed at simulating the hydraulic behavior of the solenoid-driven injector, the circuit model has been developed as a unified approach to mechanical modeling in this study. As this analytic results, we know the suction force and first order time lag for driving force can be endowed in solenoid-driven injector in controlling the injection rate. Also it can predict that the input current wave exerted on solenoid coil is the dominant factor which affects on the initial needle behavior of solenoid-driven injector than the hydraulic force generated by the constant injection pressure.

A Comparative Study of the Literature on Fire Acupuncture (Hwachim) between South and North Korea (남, 북한의 화침 연구문헌에 대한 비교연구)

  • Lim, Su-ran;Jin, Shi-hui;Kim, Yu-ra;Kim, Youn-Sub;Kim, Song-Yi
    • Korean Journal of Acupuncture
    • /
    • v.38 no.4
    • /
    • pp.209-221
    • /
    • 2021
  • Objectives : The aim of this study was to compare and analyze studies related to fire acupuncture (FA) published in South and North Korea. Methods : FA studies published in South Korea were searched through domestic and overseas databases (KISS, RISS, OASIS, and EMBASE). For North Korean studies, databases from the Information Center on North Korea and Korea Institute of Science and Technology Information were used. Among the searched literatures, clinical studies using FA as a treatment intervention were selected (i.e., randomized controlled trials, and case reports). Finally, information such as the disease for which FA was used, the characteristics of FA, and details of treatment methods for FA were extracted from the screened literatures and the results of South and North Korean studies were compared and analyzed. Results : This review included 28 South Korean studies and 9 North Korean studies. All studies in South Korea, except for the three articles that used traditional FA treatment, applied "warm needling"-like acupuncture (WA) in the form of heating the handle of the needle after inserting the needle into the skin, and most studies were conducted on diseases of the musculoskeletal system. Whereas in the North Korean studies, FA was applied to various diseases such as trigeminal neuralgia, skin diseases, and gastrointestinal diseases, and standardized FA tools were used. Conclusions : Studies on traditional FA treatment have rarely been reported in South Korea. The amount of information described in the FA studies in North Korea was limited. In this review, the characteristics of FA treatment tools in South and North Korean studies were mainly analyzed. In the future, FA studies from more diverse perspectives are needed.

Electrical Characteristics Analysis According to Electrode Shape and Distance Between Electrodes (전극 형태와 전극 간 거리에 따른 전기적 특성 분석)

  • Tae-Hee Kim;Soon-Hyung Lee;Mi-Yong Hwang;Yong-Sung Choi
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.36 no.4
    • /
    • pp.408-412
    • /
    • 2023
  • In this paper, in order to analyze high electrical insulation and cooling performance using mineral oil, the liquid insulating oil was changed in electrode shape and distance between electrodes to compare and analyze electrical characteristics according to equal electric field, quasi-equivalent electric field, and unequal electric field. As a result, the breakdown voltages were 36,875 V and 36,875 V in the form of sphere-sphere and plate-plate electrodes with equal electric fields. The breakdown voltage was 31,475 V in the sphere-plate electrode type, which is a quasi-equilibrium field, and the breakdown voltage was 28,592 V, 27,050 V, and 22,750 V in the needle-needle, sphere-needle, and needle-plate electrode types, which are unequal fields. Through this, it is possible to know the difference in breakdown voltage according to the type of electric field. The more equal the field, the higher the breakdown voltage, and the more unequal field, the lower the breakdown voltage. The difference in insulation breakdown voltage could be seen depending on the type of electric field, the insulation breakdown voltage was higher for the more equal electric field, and the insulation breakdown voltage was lower for the more unequal electric field. Also, it was confirmed that the closer the distance between the electrodes, the higher the insulation breakdown voltage, the higher the insulation breakdown current, and the insulation breakdown voltage and the insulation breakdown current were proportional.

Discharge Characteristics of Air according to the Shapes of Rod Electrode in the Rod-Plane Gap having Flame on the Plane Electrode (연소화염이 존재하는 봉대평판 갭에서 봉전극 형상에 따른 공기의 방전 특성)

  • Kim, In-Sik
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.27 no.8
    • /
    • pp.83-89
    • /
    • 2013
  • In this paper, discharge characteristics of air in the vertical arrangement of three rods(dome-shaped, cylinder-shaped, and needle-shaped rod) and plane gap having propane flame on the plane electrode are examined under the application of a.c. and d.c. high-voltages. As the result of the experiment, flashover voltages in the presence of the flame are substantially lowered than those in the absence of flame, and relative a.c. flashover voltages in the dome-shaped, cylinder-shaped, and needle-shaped rod gaps are found 32.5%, 32.1%, and 26.4% respectively. The polarity effects with the d.c. voltages are shown, and flashover voltages in negative polarity are much lowered than those in positive one. The negative flashover voltages in the dome-shaped and cylinder-shaped gaps are found 18.3% and 18.7% respectively, but the positive ones are found 53.5% and 43.2% respectively. In the needle-shaped rod gaps, meanwhile, the flame is extinguished by corona wind, and the quenching voltages are found 28.4% under the application of a.c. voltages. The ion winds of corona and the reduction of air density are the main factors of flashover reduction owing to the flame in the case of a.c. voltages, but the electrifications of the positive ion by thermal ionization besides the above factors are remarkably found in the case of d.c. voltages.

Dielectric Characteristics of Subcooled $LN_2$ for Insulation Design of HTS Fault Current Limiters (고온초전도 한류기의 절연설계를 위한 과냉각 액체질소의 절연내력 특성)

  • 백승명;정종만;김상현
    • Progress in Superconductivity and Cryogenics
    • /
    • v.5 no.2
    • /
    • pp.46-50
    • /
    • 2003
  • In the dielectric insulation design of any high temperature superconducting (HTS) apparatus as well as HTS fault current limiter in the electrical power systems, the breakdown characteristics of cryogenic coolants such as liquid nitrogen ($LN_2$) are an important factor of the insulating engineering. Previous reports concerned with the breakdown characteristics of liquid nitrogen have pointed out that bubbles and gaseous nitrogen have a treat influence on their breakdown phenomena, However, useful data for practical insulation design of HTS fault CUITent limiter operating at subcooled L$N_2$ have not been obtained enough. Therefore, this paper presents an experimental investigate of breakdown phenomena in liquid nitrogen under AC voltage, And, we observed the breakdown voltage (BDV) of liquid nitrogen with lowering temperature. The Weibull plots of the breakdown voltage of subcooled $LN_2$ for the needle-plane electrode with d= 10 mm are studied, The dependence of breakdown voltage for needle-plane and pancake coil-pancake coil electrode on temperature is illustrated, The relationship between the AC breakdown characteristics and the temperature were clarified.

Study on the Heat Transfer Characteristics of Warm Needle Materials in Korean Medicine (온침소재의 열전달특성에 관한 연구)

  • Yeo, Sujung;Chung, Jee Hyun;Kim, Young-Kon;Koo, Sungtae;Lee, Min Kyu;Lim, Sabina
    • Korean Journal of Acupuncture
    • /
    • v.31 no.3
    • /
    • pp.125-135
    • /
    • 2014
  • Objectives : Warm needling is the method combining the effects of acupuncture and moxibustion. In modern clinics, warm needling is only affected by treatment time or frequency. We need to study the physical characteristics of warm needles currently used in clinics in order to develop more efficient and economical treatments. Methods : We collected various warm needle specimens and analyzed chemical constitutions, measured heat transfer velocity, micro Vicker's hardness and specific resistance. We studied the relationship between heat transfer velocity and micro Vicker's hardness as well as that between heat transfer velocity and specific resistance. Results : The heat transfer velocity of the Silver_HL was 3.3 mm/sec, of the Au alloy group was 1.3~2.6 mm/sec, and Silver_IN, Silver_ZK and SS groups was less than 0.3 mm/sec. We therefore concluded that the needle composed of Ag has the best heat transfer velocity. In the Micro Vicker's hardness test, Vicker's hardness of the Au alloy group was 159~170 Hv, of Silver_HL was 181 Hv, and of the Silver_IN, Silver_ZK, SS group was 450.8~519 Hv. In the Silver_IN, Silver_ZK and SS groups, hardness was inversely proportial to thermal conductivity. In the specific resistance test, the specific resistance of Silver_HL was the lowest, that of the Au alloy group was the second lowest, and that of the Silver_IN, Silver_ZK, SS groups were the highest. Conclusions : We concluded that the needle composed of Ag has the best heat transfer velocity, highest electric conductivity and thermal conductivity, therefore the needle composed of Ag is suitable for warm needling.

The Effect of Valve Geometry Variation on Injection Characteristics of Injection Valve for Marine Diesel Engines (선박디젤기관용 분사밸브의 형상변화가 분사특성에 미치는 영향에 관한 계산적 고찰)

  • Park, K.;Kim, S.Y.;Choi, C.W.
    • Journal of ILASS-Korea
    • /
    • v.10 no.1
    • /
    • pp.24-34
    • /
    • 2005
  • Injection technology is one of the important technologies in a diesel engine. Many studies have done on the injection system. In this study, the fuel chamber geometry, the orifice ratio and the needle lift of the injection valve for a marine diesel engine are varied, and simulated. The result shows that the nozzle hole size has influence on the rail pressure and injection duration sensitively. The decrease of the static pressure at the nozzle hole entrance and the increase of the dynamic pressure on the outlet surface are occurred with the increase of the nozzle hole diameter. The highest dynamic pressure of the outlet was occurred at the needle lift of 0.4mm and the nozzle hole diameter of 0.328mm in this test nozzle.

  • PDF