• Title/Summary/Keyword: nearly m-compact

Search Result 14, Processing Time 0.015 seconds

니켈-흑연복합분말의 흑연코어 기화거동에 관한 연구

  • Yun, Gi-Byeong;Kim, Dong-Jin;Jeong, Heon-Saeng
    • Korean Journal of Materials Research
    • /
    • v.3 no.3
    • /
    • pp.300-309
    • /
    • 1993
  • Abstract In this work. gasification of graphite cores from nickel-coated graphite composite powders was carried out to munufacture the hollow nickel metal powders which can be used as a raw materials for porous nickel metal strips. Graphite cores were gasified by $H_2O-H_2$ mixture gases at the temperature between $800^{\circ}C$ and $900^{\circ}C$ and nearly all removed from the composite powders within 1 hour. The hollow nickel metal powders prepared from 82.2wt. % Ni-17.8wt. % C composite powders which have the graphite cores of 21${\mu}$m average size were pressed and sintered at $1150^{\circ}C$ for 1 hour in vacuum furnace. The porosities of green and sintered compacts were 45% and 30%. respectively, and pores were distributed very homogeneously in the sintered compact. It was confirmed that pore distribution and porosity in porous materials can be easily controlled by using hollow powders as a raw materials.

  • PDF

Compact Infrared/Visible Laser Transmitter Featuring an Extended Detectable Trajectory

  • Kim, Haeng-In;Lee, Hong-Shik;Lee, Sang-Shin
    • Journal of the Optical Society of Korea
    • /
    • v.16 no.4
    • /
    • pp.331-335
    • /
    • 2012
  • A miniaturized laser beam transmitter, in which a visible laser module at ${\lambda}$=650 nm is precisely stacked upon an infrared (IR) module at ${\lambda}$=905 nm, has been proposed and constructed to provide an IR collimated beam in conjunction with a collinear monitoring visible beam. In particular, the IR beam is selectively dispersed through a perforated sheet diffuser, so as to create a rapidly diverging close-range beam in addition to a highly defined long-range beam simultaneously. The complementary close-range beam plays a role in mitigating the blind region in the vicinity of the transmitter, which is inevitably missed by the main long-range beam, thereby uniformly extending the transmitter's effective trajectory that is sensed by a receiver. The proposed transmitter was designed through numerical simulations and then fabricated by incorporating a diffuser sheet, perforated with an aperture of 2 mm. For the manufactured transmitter, the IR long-range beam was observed to have divergences of ~2.3 and 1.6 mrad in the fast and slow axes, respectively, while the short-range beam yielded a divergence of ~24 mrad. The angular alignment between the long-range IR and visible beams was as accurate as ~0.5 mrad. According to an outdoor feasibility test involving a receiver, the combination of the IR long- and short-range beams was proven to achieve a nearly uniform trajectory over a distance ranging up to ~600 m, with an average detectable cross-section of ${\sim}60{\times}80cm^2$.

IGRINS Design and Performance Report

  • Park, Chan;Jaffe, Daniel T.;Yuk, In-Soo;Chun, Moo-Young;Pak, Soojong;Kim, Kang-Min;Pavel, Michael;Lee, Hanshin;Oh, Heeyoung;Jeong, Ueejeong;Sim, Chae Kyung;Lee, Hye-In;Le, Huynh Anh Nguyen;Strubhar, Joseph;Gully-Santiago, Michael;Oh, Jae Sok;Cha, Sang-Mok;Moon, Bongkon;Park, Kwijong;Brooks, Cynthia;Ko, Kyeongyeon;Han, Jeong-Yeol;Nah, Jakyuong;Hill, Peter C.;Lee, Sungho;Barnes, Stuart;Yu, Young Sam;Kaplan, Kyle;Mace, Gregory;Kim, Hwihyun;Lee, Jae-Joon;Hwang, Narae;Kang, Wonseok;Park, Byeong-Gon
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.39 no.2
    • /
    • pp.90-90
    • /
    • 2014
  • The Immersion Grating Infrared Spectrometer (IGRINS) is the first astronomical spectrograph that uses a silicon immersion grating as its dispersive element. IGRINS fully covers the H and K band atmospheric transmission windows in a single exposure. It is a compact high-resolution cross-dispersion spectrometer whose resolving power R is 40,000. An individual volume phase holographic grating serves as a secondary dispersing element for each of the H and K spectrograph arms. On the 2.7m Harlan J. Smith telescope at the McDonald Observatory, the slit size is $1^{{\prime}{\prime}}{\times}15^{{\prime}{\prime}}$. IGRINS has a plate scale of 0.27" pixel-1 on a $2048{\times}2048$ pixel Teledyne Scientific & Imaging HAWAII-2RG detector with a SIDECAR ASIC cryogenic controller. The instrument includes four subsystems; a calibration unit, an input relay optics module, a slit-viewing camera, and nearly identical H and K spectrograph modules. The use of a silicon immersion grating and a compact white pupil design allows the spectrograph collimated beam size to be 25mm, which permits the entire cryogenic system to be contained in a moderately sized ($0.96m{\times}0.6m{\times}0.38m$) rectangular Dewar. The fabrication and assembly of the optical and mechanical components were completed in 2013. From January to July of this year, we completed the system optical alignment and carried out commissioning observations on three runs to improve the efficiency of the instrument software and hardware. We describe the major design characteristics of the instrument including the system requirements and the technical strategy to meet them. We also present the instrumental performance test results derived from the commissioning runs at the McDonald Observatory.

  • PDF

IGRINS First Light Instrumental Performance

  • Park, Chan;Yuk, In-Soo;Chun, Moo-Young;Pak, Soojong;Kim, Kang-Min;Pavel, Michael;Lee, Hanshin;Oh, Heeyoung;Jeong, Ueejeong;Sim, Chae Kyung;Lee, Hye-In;Le, Huynh Anh Nguyen;Strubhar, Joseph;Gully-Santiago, Michael;Oh, Jae Sok;Cha, Sang-Mok;Moon, Bongkon;Park, Kwijong;Brooks, Cynthia;Ko, Kyeongyeon;Han, Jeong-Yeol;Nah, Jakyuong;Hill, Peter C.;Lee, Sungho;Barnes, Stuart;Park, Byeong-Gon;T., Daniel
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.39 no.1
    • /
    • pp.52.2-52.2
    • /
    • 2014
  • The Immersion Grating Infrared Spectrometer (IGRINS) is an unprecedentedly minimized infrared cross-dispersed echelle spectrograph with a high-resolution and high-sensitivity optical performance. A silicon immersion grating features the instrument for the first time in this field. IGRINS will cover the entire portion of the wavelength range between 1.45 and $2.45{\mu}m$ accessible from the ground in a single exposure with spectral resolution of 40,000. Individual volume phase holographic (VPH) gratings serve as cross-dispersing elements for separate spectrograph arms covering the H and K bands. On the 2.7m Harlan J. Smith telescope at the McDonald Observatory, the slit size is $1^{\prime\prime}{\times}15^{\prime\prime}$. IGRINS has a $0.27^{\prime\prime}$ pixel-1 plate scale on a $2048{\times}2048$ pixel Teledyne Scientific & Imaging HAWAII-2RG detector with SIDECAR ASIC cryogenic controller. The instrument includes four subsystems; a calibration unit, an input relay optics module, a slit-viewing camera, and nearly identical H and K spectrograph modules. The use of a silicon immersion grating and a compact white pupil design allows the spectrograph collimated beam size to be 25mm, which permits the entire cryogenic system to be contained in a moderately sized rectangular vacuum chamber. The fabrication and assembly of the optical and mechanical hardware components were completed in 2013. In this presentation, we describe the major design characteristics of the instrument and the early performance estimated from the first light commissioning at the McDonald Observatory.

  • PDF