• Title/Summary/Keyword: near-infrared light

Search Result 256, Processing Time 0.027 seconds

Skin depth profiling by using fiber optic probes in the near infrared

  • Woo, Young-Ah;jung, Suh-Eun;Kim, Hyo-Jin
    • Proceedings of the SCSK Conference
    • /
    • 2003.09b
    • /
    • pp.218-218
    • /
    • 2003
  • Recently we showed the prototype portable device for the determination of human skin moisture by using near infrared spectroscopy. In order to optimize the acquiring condition of NIR spectrum of skin and control the target information of water depending the site such as epidermis and dermis, skin depth profiling was investigated changing the distance between illuminations and receiving of radiation in the terminal of fiber probe. The colleted light information could be controlled by changing the distance of the fiber optic probes. It was confirmed that the longer distance we used, the deeper site from the skin surface we could get information from in this study. Four kinds of probes with distances such as 0.03 mm, 0.1 mm, 0.5 mm, and 1.0 mm were used. In addition, the gap size from 0.3 mm to 3.0 mm was studied to control the intensity of water absorbance effectively and to avoid saturation of water absorption. We also investigated the reference materials depending the reflectance ratio for water absorption not to be saturated because of the strong absorptivity of water. Furthermore, spectroscopic information regarding free water and bound water around 1850 nm was investigated by using the different distance of fiber optic probes. This study would be great help to control the spectroscopic information of water to be measured depending the site where water exists.

  • PDF

Near-infrared polarimetric study of near-Earth object 252P/LINEAR: An implication of scattered light from the evolved dust particles

  • Kwon, Yuna G.;Ishiguro, Masateru;Kwon, Jungmi;Kuroda, Daisuke;Im, Myungshin;Choi, Changsu;Tamura, Motohide;Nagayama, Takahiro;Kawai, Nobuyuki;Watanabe, Jun-Ichi
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.44 no.2
    • /
    • pp.44.2-44.2
    • /
    • 2019
  • Comets, one of the least-altered leftovers from the nascent solar system, have probably preserved the primitive structure inside, whereas their surfaces become modified from the initial states after repetitive orbital revolutions around the Sun. Resurfacing makes the surface drier and more consolidated than the bulk nuclei, creating inert refractory dust layer ("dust mantle"). Near-infrared (NIR; 1.25-2.25 m) polarimetry is theoretically expected to maximize contrast of the porosity between inner fresh and evolved dust particles, by harboring more dust constituents in the single wavelength than the optical; thus, intensifies electromagnetic interaction in dust aggregates. Despite such an advantage, only a few studies have been made in this approach mainly due to the limited accessibility of available facilities. Herein, we present our new multi-band NIR polarimetric study of near-Earth object 252P/LINEAR over 12 days near perihelion, together with the results of optical (0.48-0.80m) imaging observations and backward dynamical simulation of the comet. Based on the results, we will characterize the dust properties of the comet and discuss the possible environmental (temperature and UV radiation) effects that could produce the observed phenomena.

  • PDF

Measurement Reliability of Axial Length of the Human Eye by using Partial Coherence Interferometry

  • Kim, Jae-Hyung;Moon, Tae Hwan;Chae, Ju Byung;Hyung, Sungmin
    • Journal of the Optical Society of Korea
    • /
    • v.18 no.5
    • /
    • pp.546-550
    • /
    • 2014
  • To investigate the minimum near-infrared ray intensity required (quantifiable threshold value) for consistent measurements of axial length (AL) using partial coherence interferometry (PCI), we attached two polarizing lenses (PL) to two types of PCI (IOLmaster, ALscan). The near-infrared ray intensity of PCI was modified by rotating the axis of one PL at intervals of 5 degrees. The right eye of each volunteer was measured three times and the AL and signal-to-noise ratio (SNR) was recorded five times for each measurement. Reduction of light intensity was theoretically estimated using Malus' Law. AL was measured consistently with both IOLmaster and ALscan until they reached 55 degrees (1.33 % of intensity) and 60 degrees (0.77%), respectively (P = 0.343, Log-rank test). In contrast, SNR decreased as light intensity decreased. In addition, to analyze media opacities that precluded measurement of AL, we retrospectively reviewed the medical records of patients unmeasurable by PCI (ALscan) from May to November 2013. Thirty-eight of 473 eyes (8.0%) could not be measured using ALscan due to media opacities, such as severe posterior subcapsular cataract (PSC, 11 eyes), hypermature cataract (9 eyes), and vitreous hemorrhage (18 eyes). The mean grades of vitreous haze and PSC were $7.72{\pm}0.96$ and $4.45{\pm}1.04$, respectively. In conclusion, up to 0.77-1.33% of near-infrared rays decreased, and AL could be measured consistently.

Real-Time Localization of Parathyroid Glands with Near Infrared Light during Thyroid and Parathyroid Surgery (갑상선·부갑상선 수술 중 근적외선을 이용한 실시간 부갑상선의 국소화)

  • Kim, Sung Won;Jeong, Yeong Wook;Koh, Yoon Woo;Lee, Kang Dae
    • International journal of thyroidology
    • /
    • v.11 no.2
    • /
    • pp.92-98
    • /
    • 2018
  • Intraoperative identification and localization of parathyroid glands are crucial step in preventing postoperative hypocalcemia during thyroid and parathyroid surgery. If there is a method to predict the parathyroid's location rather than detecting and verifying with naked eye, it would make the operator easier to find and identify the parathyroid. Recently, near-infrared light imaging technologies have been introduced in the fields of thyroid and parathyroid surgery to predict the localization of the parathyroid. These are being conducted in two ways: autofluorescence imaging with a unique intrinsic fluorophore in the parathyroid tissues and fluorescence imaging with external fluorescence materials specially absorbed into parathyroid tissues. We are suggest that parathyroid glands can be detected by surgeon with NIR autofluorescence imaging even if they are covered by fibrofatty tissues before they are detected by surgeon's naked eye. These novel techniques are very useful to identify and preserve parathyroid glands during thyroidectomy. In this article, we reviewed the latest papers that describe autofluorescence imaging and exogenous ICG fluorescence imaging of parathyroid glands during thyroid and parathyroid surgery.

Development of Automatic Peach Grading System using NIR Spectroscopy

  • Lee, Kang-J.;Choi, Kyu H.;Choi, Dong S.
    • Proceedings of the Korean Society of Near Infrared Spectroscopy Conference
    • /
    • 2001.06a
    • /
    • pp.1267-1267
    • /
    • 2001
  • The existing fruit sorter has the method of tilting tray and extracting fruits by the action of solenoid or springs. In peaches, the most sort processing is supported by man because the sorter make fatal damage to peaches. In order to sustain commodity and quality of peach non-destructive, non-contact and real time based sorter was needed. This study was performed to develop peach sorter using near-infrared spectroscopy in real time and nondestructively. The prototype was developed to decrease internal and external damage of peach caused by the sorter, which had a way of extracting tray with it. To decrease positioning error of measuring sugar contents in peaches, fiber optic with two direction diverged was developed and attached to the prototype. The program for sorting and operating the prototype was developed using visual basic 6.0 language to measure several quality index such as chlorophyll, some defect, sugar contents. The all sorting result was saved to return farmers for being index of good quality production. Using the prototype, program and MLR(multiple linear regression) model, it was possible to estimate sugar content of peaches with the determination coefficient of 0.71 and SEC of 0.42bx using 16 wavelengths. The developed MLR model had determination coefficient of 0.69, and SEP of 0.49bx, it was better result than single point measurement of 1999's. The peach sweetness grading system based on NIR reflectance method, which consists of photodiode-array sensor, quartz-halogen lamp and fiber optic diverged two bundles for transmitting the light and detecting the reflected light, was developed and evaluated. It was possible to predict the soluble solid contents of peaches in real time and nondestructively using the system which had the accuracy of 91 percentage and the capacity of 7,200 peaches per an hour for grading 2 classes by sugar contents. Draining is one of important factors for production peaches having good qualities. The reason why one farm's product belows others could be estimated for bad draining, over-much nitrogen fertilizer, soil characteristics, etc. After this, the report saved by the peach grading system will have to be good materials to farmers for production high quality peaches. They could share the result or compare with others and diagnose their cultural practice.

  • PDF

A measurement of wave length response on light emitting diode by a simplified wavemeter with a semiconductor color sensor

  • Muraoka, Tetsuya
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1991.10b
    • /
    • pp.1956-1960
    • /
    • 1991
  • This paper describes the measured results upon monochromatic light, compound light, and light emanated from light emitting diodes by a simplified wavemeter with a semiconductor color sensor. Since a single unit element of a semiconductor color sensor with two PN junction photodiodes has been developed, the author has fabricated the simplified wave detector by using the element. The simplified wive detector has been measured results upon monochromatic light, compound light, and light emanated from light emitting diodes. Since luminescent color of each diode locates in luminosity region, comparison of measured values of PD-150 and PD-151 resulted no remarkable difference in averaged wave length. As for monochromatic light, PD-151 showed very cross value to the color filter peak value rather than PD-150. As for compound light, PD-150 has shown such influence of long wave length light which reaches to near infrared ray with respect to PD-151.

  • PDF

SPECTROSCOPIC AND PHOTOMETRIC STUDY OF STARBURST GALAXIES: OPTICAL AND NEAR INFRARED PROPERTIES OF A BLUE COMPACT DWARF GALAXY MRK 49 IN THE VIRGO CLUSTER

  • Sung, Eon-Chang;Kyeong, Jae-Mann;Byun, Yong-Ik
    • Journal of The Korean Astronomical Society
    • /
    • v.41 no.5
    • /
    • pp.121-137
    • /
    • 2008
  • We present optical and near-infrared imaging and long-slit spectroscopy for the blue compact dwarf galaxy (BCD) Mrk 49 in the Virgo Cluster. The surface brightness distribution analysis shows that Mrk 49 consists of an off-centered blue bright compact core of r = 10" and a red faint outer exponential envelope. The $H_{\alpha}$ image and color difference suggest that these two components have different stellar populations: a high surface brightness population of massive young stars and an underlying low surface brightness population of older stars. The redder near-infrared colors of the inner most region suggest that the near-infrared flux of Mrk 49 originates from evolved massive stars associated with the current star-forming activity. The total apparent magnitude is $B_T\;=\;14.32$ mag and the mean effective surface brightness is ${\mu}_{eff}(B)\;=\;21.56$ mag $arcsec^{-2}$. Long-slit spectroscopy shows that Mrk 49 rotates apparently as a solid body within r = 10" in a plane at position angle 55 degrees with an amplitude of about $20\;km\;sec^{-1}$. The measured radial velocity of Mrk 49 was derived as $1,535\;km\;sec^{-1}$; and the total mass of stars and gases is in the range of 3 to $6\;{\times}\;10^9\;M_{\odot}$. The mass-to-light ratios for the central region of Mrk 49 in I and B band are estimated 1.0 and 0.5, respectively. The upper limit of the dark matter to visible matter ratio seems to be < 5. The oxygen abundance is $12\;+\;\log(O/H)\;=\;8.21\;{\pm}\; 0.1$ which is about one quarter of the solar value while the relative helium abundance appears to be similar to that of the sun.

A Study on Performance for Camouflage of Domestic and Foreign Combat Uniforms (국내·외 전투복의 카무플라주(Camouflage) 성능 연구)

  • Kang, Jinwoo;Lee, Minhee;Hong, Seongdon;Moon, Sunjeong
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.40 no.6
    • /
    • pp.1025-1033
    • /
    • 2016
  • It is important to compare and analyze digital camouflage from different countries to promote the continuous development of a camouflage combat uniform. This effort should lead to developing a camouflage pattern suitable for the domestic environment and expand its performance of night camouflage. This study investigates digital camouflage by comparing camouflage fabrics sampled from Korea and eight other countries (USA, UK, Singapore, Croatia, Colombia, and Mongolia) in terms of textile, near-infrared reflectivity of colors, and color distribution. First, the fabric construction of camouflage from Korea, UK, US, Singapore, Span, and Croatia were all characterized by derivative plain weaves, while derivative twill weaves were generally used in Croatia and Mongolia. It is assumed that derivative plain weaves are adopted to improve the tearing strength of fine yarns. However, twill weaves enhance the flexibility of coarse yarn fabrics. Next, reflectivity change was analyzed based on camouflage color. The reflectivity of a combat uniform in Korea, Colombia, Croatia, and UK increased before 780nm in the visible light range, but remained consistent from 800nm which falls under the near-infrared range. In contrast, camouflage samples in Mongolia, Span, Singapore and USA showed a gradual increase of reflectivity in the near-infrared range. Finally, the color distribution analysis of digital camouflage found that camouflage of countries with desert or woodland combat settings dominantly contained brown colors. It indicates the color pattern consideration of different geographic regions is important to determine camouflage performance. This research involves basic study that will have implications for developing patterns and colors suitable for the South Korean environment and expand its use as night camouflage that helps achieve continuous improved camouflage performance.

Research on a Non-invasive Blood Glucose level Estimation Algorithm based on Near- infrared Spectroscopy (근적외선 분광법 기반 비침습식 혈당 수치 추정 알고리즘 연구)

  • Young-Man Kang;Soon-Hee Han
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.18 no.6
    • /
    • pp.1353-1362
    • /
    • 2023
  • Various methods are being attempted to resolve the inconvenience of blood glucose meters used to check blood sugar levels. In this paper, we attempted to estimate blood sugar levels non-invasively using machine learning technology from spectral data acquired using a near-infrared sensor. The non-invasive blood glucose meter used in the study has a total of six near-infrared ray emitters, including visible rays, and a light receiver that receives them. It is a device created to collect spectral data on specific parts of the human body, such as the fingers. To verify whether there was a significant difference depending on blood sugar level, we attempted to estimate blood sugar level through machine learning algorithms. As a result of applying five machine learning algorithm techniques to the collected data and adjusting various hyper parameters, it was confirmed that the support vector regression algorithm showed the best performance.

Electrophotographic properties of $\tau$-H$_2$Pc/oxadiazole photoreceptor (I) ($\tau$-H$_2$PC/oxadiazole 유기이층막의 감광특성 연구 (I))

  • 이덕출;박구범;조기선;오승현
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1993.11a
    • /
    • pp.141-143
    • /
    • 1993
  • A nontoxic organic photoreceptor for near infrared light has been developed. A double layered photoreceptor using $\tau$-H$_2$Pc as the CGL was made. The CTL was formed by oxadiazole derivative dispersed in two other host polymers. This photoreceptor has a charge acceptance of -900 V when a corona charge is used, and has residual potentials of -20 V for PC, and -10 V for PVB by light irradiation.

  • PDF