• Title/Summary/Keyword: near-infrared

Search Result 1,696, Processing Time 0.026 seconds

Assessment and Comparison of Three Dimensional Exoscopes for Near-Infrared Fluorescence-Guided Surgery Using Second-Window Indocyanine-Green

  • Cho, Steve S.;Teng, Clare W.;Ravin, Emma De;Singh, Yash B.;Lee, John Y.K.
    • Journal of Korean Neurosurgical Society
    • /
    • v.65 no.4
    • /
    • pp.572-581
    • /
    • 2022
  • Objective : Compared to microscopes, exoscopes have advantages in field-depth, ergonomics, and educational value. Exoscopes are especially well-poised for adaptation into fluorescence-guided surgery (FGS) due to their excitation source, light path, and image processing capabilities. We evaluated the feasibility of near-infrared FGS using a 3-dimensional (3D), 4 K exoscope with near-infrared fluorescence imaging capability. We then compared it to the most sensitive, commercially-available near-infrared exoscope system (3D and 960 p). In-vitro and intraoperative comparisons were performed. Methods : Serial dilutions of indocyanine-green (1-2000 ㎍/mL) were imaged with the 3D, 4 K Olympus Orbeye (system 1) and the 3D, 960 p VisionSense Iridium (system 2). Near-infrared sensitivity was calculated using signal-to-background ratios (SBRs). In addition, three patients with brain tumors were administered indocyanine-green and imaged with system 1, with two also imaged with system 2 for comparison. Results : Systems 1 and 2 detected near-infrared fluorescence from indocyanine green concentrations of >250 ㎍/L and >31.3 ㎍/L, respectively. Intraoperatively, system 1 visualized strong near-infrared fluorescence from two, strongly gadolinium-enhancing meningiomas (SBR=2.4, 1.7). The high-resolution, bright images were sufficient for the surgeon to appreciate the underlying anatomy in the near-infrared mode. However, system 1 was not able to visualize fluorescence from a weakly-enhancing intraparenchymal metastasis. In contrast, system 2 successfully visualized both the meningioma and the metastasis but lacked high resolution stereopsis. Conclusion : Three-dimensional exoscope systems provide an alternative visualization platform for both standard microsurgery and near-infrared fluorescent guided surgery. However, when tumor fluorescence is weak (i.e., low fluorophore uptake, deep tumors), highly sensitive near-infrared visualization systems may be required.

JK PHOTOMETRY OF BRIGHT GIANTS IN NGC6712

  • KYEONG JAE-MANN;BYUN YONG-IK
    • Journal of The Korean Astronomical Society
    • /
    • v.31 no.2
    • /
    • pp.127-140
    • /
    • 1998
  • With a large format near-infrared camera at the 2.2-m telescope on Mauna Kea Observatory, we performed J K near-infrared observations for the metal rich globular cluster NGC6712. This cluster lies near the galactic plane and therefore suffers heavy reddening. We present the near-infrared color-magnitude diagram and also derive the metallicity ([Fe/H] ${\~}-0.96{\pm}0.27$) as well as its distance modulus ((m - M) ${\~}13.42{\pm}0.12$).

  • PDF

Near-infrared face recognition by fusion of E-GV-LBP and FKNN

  • Li, Weisheng;Wang, Lidou
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.9 no.1
    • /
    • pp.208-223
    • /
    • 2015
  • To solve the problem of face recognition with complex changes and further improve the efficiency, a new near-infrared face recognition algorithm which fuses E-GV-LBP and FKNN algorithm is proposed. Firstly, it transforms near infrared face image by Gabor wavelet. Then, it extracts LBP coding feature that contains space, scale and direction information. Finally, this paper introduces an improved FKNN algorithm which is based on spatial domain. The proposed approach has brought face recognition more quickly and accurately. The experiment results show that the new algorithm has improved the recognition accuracy and computing time under the near-infrared light and other complex changes. In addition, this method can be used for face recognition under visible light as well.

ESTIMATION OF SUGAR AND REDUCING SUGAR IN MOLASSES USING NEAR INFRARED REFLECTANCE SPECTROSCOPY

  • Mehrotra, Ranjana;Gupta, Alka;Tewari, Jagdish;Varma, S.P.
    • Proceedings of the Korean Society of Near Infrared Spectroscopy Conference
    • /
    • 2001.06a
    • /
    • pp.1258-1258
    • /
    • 2001
  • Estimation of sugar and reducing sugar content in molasses is very important task in sugar refineries. Conventional methods of determination of sugar content in molasses samples are highly time consuming and employ hazardous chemicals. Due to the physical properties of molasses, probability of error in conventional analytical techniques is high. These methods have proven to be inefficient for a process control in any sugar industry. Hence development of a rapid, inexpensive, physical and also accurate method for sugar determination in molasses will be highly useful. Near Infrared spectroscopy is being widely used worldwide as an analytical technique in food industry. The technique offers the advantage of being non-destructive and rapid. The present paper highlights the potential of near infrared reflectance spectroscopy as a rapid and automated analytical technique for determination of sugar and reducing sugar content in molasses. A number of molasses samples were collected during and after the sugar season from Havana Sugar Industry, Havana. The samples were chosen so as to obtain a wide range of concentration of sugar and reducing sugars. This was done in order to achieve a good calibration curve with widely spread data points. These samples were scanned in the region of 1100 - 2500 nm in diffuse reflectance mode. An indigenous ELICO NIR spectrophotometer, modified according to the requirements of sugar industry was used for this purpose. Each sample was also analyzed simultaneously by standard chemical methods. Chemical values were taken as reference for near infrared analysis. In order to obtain the most accurate calibration for the set of samples, various mathematical treatments were employed. Partial Least Square method was found to be most suitable for the analysis. A comparison is made between the actual values (chemical values) and the predicted values (NIR values). The actual values agree very well with the predicted values showing the accuracy of the technique. The validity of the technique is checked by predicting the concentration of sugar in unknown molasses samples using the calibration curve. The present investigation assesses the feasibility of the technique for on-line monitoring of sugars present in molasses in sugar industries.

  • PDF

Near Infrared Diffuse Reflectance Spectroscopy to Measure Pulmonary Edema

  • Larry Leonardi;David H.Burns;Luis Openheimer;Rene P.Michel
    • Near Infrared Analysis
    • /
    • v.2 no.1
    • /
    • pp.43-53
    • /
    • 2001
  • A non-invasive spectroscopic method is presented for the measurement of pulmonary edema. Both early diagnosis and quantitative edema estimates were investigated. The spectroscopic determination of pulmonary edema involved the acquisition of diffuse reflectance spectra in the near-infrared (NIR) region with change in water concentration - water is the main constituent of edema fluid. Pulmonary edema was induced into the excised perfused lungs of seven animals by elevating the hydrostatic pressure. Estimates of edema were ascertained from a partial least squares regression of the measured spectral response. Actual edema was determined from the change (increase) in total lung weight. Estimates in relative lung weight increases due to in vitro edema were made with the near infrared spectra. The results revealed that fluid accumulation produced spectral changes in the O-H and C-H absorptions as well as scattering changes in the spectra. Histology of the lung was used to verify the presence or absence of interstitial and alveolar edema. Results demonstrated that near infrared spectroscopy might provide a new tool for clinical assessment of pulmonary edema.

DETERMINATION OF SUGARS AND ORGANIC ACIDS IN ORAGE JUICES USING NEAR INFRARED DIFFUSE REFLECTANCE SPECTROSCOPY

  • Tewari, Jagdish;Mehrotra, Ranajana;Gupta, Alka;Varma, S.P.
    • Proceedings of the Korean Society of Near Infrared Spectroscopy Conference
    • /
    • 2001.06a
    • /
    • pp.1522-1522
    • /
    • 2001
  • Beverages based on fruit juices are among the most popular commercially available drinks. There is an ever-increasing demand for these juices in the market. Orange juice is one of the most common as well as most favorite flavor. The fruit processing industries have a tremendous responsibility of quality control. For quality evaluation estimation of various components of the juice is necessary. Sucrose, glucose, fructose, citric acid and malic acid are the prime components of orange juice. Little information is available on analysis of orange juice. However, conventional and general wet chemistry procedures are currently being used which are no longer desired by the industry owing to the time involved, labor input and harmful chemicals required for each analysis. Need to replace these techniques with new, highly specific and automated sophisticated techniques viz. HPLC and spectroscopy has been realized since long time. Potential of Near Infrared Spectroscopy in quantitative analysis of different components of food samples has also been well established. A rapid, non-destructive and accurate technique based on Near Infrared Spectroscopy for determination of sugars and organic acids in orange juice will be highly useful. The current study is an investigation into the potential of Near Infrared Diffuse Reflectance Spectroscopy for rapid quantitative analysis of sucrose, glucose, fructose citric acid and malic acid in orange juice. All the Near Infrared measurements were peformed on a dispersive NIR spectrophotometer (ELICO 153) in diffuse reflectance mode. The spectral region from 1100 to 2500nm has been explored. The calibration has been performed on synthetic samples that are mixtures of sucrose, glucose, fructose, citric acid and malic acid in different concentration ranges typically encountered real orange juice. These synthetic samples are therefore considered to be representatives of natural juices. All the Near Infrared spectra of synthetic samples were subjected to mathematical analysis using Partial Least Square (PLS) algorithm. After the validation, calibration was applied to commercially available real samples and freshly squeezed natural juice samples. The actual concentrations were compared with those predicted from calibration curve. A good correlation is obtained between actual and predicted values as indicated by correlation coefficient ($R^2$) value, which is close to unity, showing the feasibility of the technique.

  • PDF