• Title/Summary/Keyword: near-P.D-B

Search Result 80, Processing Time 0.03 seconds

An efficient genetic algorithm for the design optimization of cold-formed steel portal frame buildings

  • Phan, D.T.;Lim, J.B.P.;Tanyimboh, T.T.;Sha, W.
    • Steel and Composite Structures
    • /
    • v.15 no.5
    • /
    • pp.519-538
    • /
    • 2013
  • The design optimization of a cold-formed steel portal frame building is considered in this paper. The proposed genetic algorithm (GA) optimizer considers both topology (i.e., frame spacing and pitch) and cross-sectional sizes of the main structural members as the decision variables. Previous GAs in the literature were characterized by poor convergence, including slow progress, that usually results in excessive computation times and/or frequent failure to achieve an optimal or near-optimal solution. This is the main issue addressed in this paper. In an effort to improve the performance of the conventional GA, a niching strategy is presented that is shown to be an effective means of enhancing the dissimilarity of the solutions in each generation of the GA. Thus, population diversity is maintained and premature convergence is reduced significantly. Through benchmark examples, it is shown that the efficient GA proposed generates optimal solutions more consistently. A parametric study was carried out, and the results included. They show significant variation in the optimal topology in terms of pitch and frame spacing for a range of typical column heights. They also show that the optimized design achieved large savings based on the cost of the main structural elements; the inclusion of knee braces at the eaves yield further savings in cost, that are significant.

The Effects of Operating Conditions and Injector Geometry on the Spray Characteristics of Swirl Injectors (스월 인젝터의 작동조건 및 인젝터 형상에 따른 분무특성)

  • Kim, D.J.;Im, J.H.;Han, P.G.;Yoon, Y.B.
    • Journal of ILASS-Korea
    • /
    • v.9 no.1
    • /
    • pp.21-29
    • /
    • 2004
  • The flow characteristics of a swirl injector were investigated with the variation of the flow condition and geometric dimensions, such as orifice length for considering the viscous effect and tangential entry port area for considering the swirl intensity. The liquid film thickness strongly influencing on the formed drop size of the spray was measured using a new technique. The film thickness measurement technique proposed here, used the attenuation of fluorescence signal near the injector exit. The breakup length that is important for the flame location as well as the spray cone angle which influences on the ignition performance was measured using a backlit stroboscopic photography technique. From the experimental results, it is found that an increase in injection pressure decreased the film thickness and breakup length, and also enlarged the spray cone angle. A decrease in orifice length and tangential entry port area has a similar tendency of thinner film thickness, shorter breakup length and larger spray cone angle. In the present study, we proposed empirical models of the flow characteristics of the swirl injectors.

  • PDF

The Application of Al-foil Electrode for Detecting Partial Discharge Signal in Middle Joint Box of EHV Power Cable (초고압 전력케이블용 중간 접속부 내의 부분방전신호 검출을 위한 박전극 응용)

  • Lee, Yong-Sung;Yang, Jong-Kyung;Yang, Jong-Keok;Choi, Yong-Sung;Park, Dae-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2005.11a
    • /
    • pp.142-144
    • /
    • 2005
  • To detect partial discharge of 154kV joint box, we have made experiment by using the Al-foil electrode sensor. Generally the signals which are detected in partial discharge test of underground power transmission cable are accompanied wi th both noises of high voltage and noises of surrounding power cable. The most noise in near to end part of joint box is corona, beside other noises flowed from surrounding area. Partial discharge test is difficulty due to these noises. First, we had used Al-Foi1 sensor on middle joint box of 154[kV] underground transmission power cable, and then analyzed reliability of calibration signal by using the Al-Foi1 electrode sensor of NJB. From above results, decrement properties measured highly. But incase of injecting calibration signal of 500[pC] after measuring signals in IJB, the S/N ratio had about 25[dB] acquisition.

  • PDF

CALIBRATION PROCESS OF THE COSMIC INFRARED BACKGROUND EXPERIMENT (적외선 우주배경복사 관측 실험 검교정)

  • Lee, D.H.;Nam, U.W.;Kim, G.H.;Pak, S.;Zemcov, M.;Bock, J.J.;Battle, J.;Sullivan, I.;Mason, P.;Tsumura, K.;Matsumoto, T.;Matsuura, S.;Renbarger, T.;Keating, B.
    • Publications of The Korean Astronomical Society
    • /
    • v.22 no.4
    • /
    • pp.169-175
    • /
    • 2007
  • The international cooperation project CIBER (Cosmic Infrared Background ExpeRiment) is a rocket-borne instrument, of which the scientific goal is to measure the cosmic near-infrared extra-galactic background to search for signatures of primordial galaxy formation. CIBER consists of a wide-field two-color camera, a low-resolution absolute spectrometer, and a high-resolution narrow-band imaging spectrometer. Currently, all the subsystems have been built, and the integration, testing, and calibration of the CIBER system are on process for the scheduled launch in June 2008.

Application of AI-foil Electrode for Detecting Partial Discharge in Middle Joint Box (초고압 전력케이블용 중간접속부내 부분방전 검출을 위한 박전극 응용)

  • Kim, Dae-Yeol;Yun, Ju-Ho;Choi, Yong-Sung;Park, Dae-Hee;Lee, Kyung-Sup
    • Proceedings of the KIEE Conference
    • /
    • 2007.04b
    • /
    • pp.79-81
    • /
    • 2007
  • To detect partial discharge of 154kV joint box, we have made experiment by using the Al-foil electrode sensor. Generally the signals which are detected in partial discharge test of underground power transmission cable are accompanied with both noises of high voltage and noises of surrounding power cable. The most noise in near to end part of joint box is corona, beside other noises flowed from surrounding area. Partial discharge test is difficulty due to these noises. First, we had used Al-Foil sensor on middle joint box of 154[kV] underground transmission power cable, and then analyzed reliability of calibration signal by using the Al-Foil electrode sensor of NJB. From above results, decrement properties measured highly. But incase of injecting calibration signal of 500[pC] after measuring signals in IJB, the S/N ratio had about 25[dB] acquisition.

  • PDF

Characteristics of Environmental Contamination for the Groundwater and Stream Water in the Vicinity of the Woonjeongdong Sanitary Landfill Area in Kwangju-city, Korea (광주광역시 운정동 위생매립장 주변 지하수와 하천수의 환경지구화학적 오염특성)

  • 오근창;윤정환;김경웅;박천영;김정빈
    • Economic and Environmental Geology
    • /
    • v.34 no.6
    • /
    • pp.523-537
    • /
    • 2001
  • The physical properties of pH, turbidity, TDS and salt contents in the stream water near the entrance of Woonjcongdong sanitary landfill area with a drainage pipe are higher than those in neighbored drainage system, but DO it lower than that in neighbored drainage system blue to the eutrophication. In the ground water, pH, turbidity, TDS and salt contents at A ,F and C where may be under effect of the Woonjeongdong sanitary landfill area, are also shown higher values in contrast to other groundwater site, like B , D , and E , Particularly, the groundwater in A , F and C are plotted in Na-Cl type (If the piper diagram, which is an another important prolf of the contaminapion by the leachate and washing water from the Woonjeongdong sanitary landfill area. Some elements and physical properties of the waters in rainy season are desplayed a clear characteristics of contaminaton, compared to the theose of winter in thes study. Elements such as Ca, Mg, Na, K, Cl­,$SO_4^{2-} , \;and \;F­^-$) are accompanied well with each other by the result of water in the vicinity of landfillarea.

  • PDF

Studies on Raw Silk Cohesion for Promotion (생사의 포합향상에 관한 연구)

  • 최병희;김병호;원성희
    • Journal of Sericultural and Entomological Science
    • /
    • v.15 no.1
    • /
    • pp.37-48
    • /
    • 1973
  • The purpose of this studies is to improve the cohesion of raw silk through various analyses on cocoon drying, cooking, reeling, re-reeling, and on the properties of water. Also we investigated the correlation between silk testing items which we have reached to the following results. 1. Drying of cocoon When cocoons were slowly dried with 100$^{\circ}C$, the results of cohesion became much better. On the other hand, the results were considerably decreased in case the temperature with 115$^{\circ}C$. 2. Cooking of cocoon In case of the cooking of cocoon, we found that the result of cohesion was best with incomplete cooking, that of the control was next, while in over cooking, the results were very low. Also the results of cohesion were much better when using the method of over cooking with sericin arrestive agent than that of incomplete cooking with sericin agglutinating agent. 3. Reeling of cocoon A) When the temperature of reeling bath was 25-45$^{\circ}C$, the results of cohesion test were much better, but at the temperature below 25$^{\circ}C$ or above 45$^{\circ}C$, the results became worse. B) With out the process of croissieur, the results of cohesion were too bad, but in case of croissieur more than 1cm, cohesion became better rapidly. Further more, we understood that the results of cohesion were improving slightly with longer length of croissieur. C) When the velocity of reeling was increased, the results of cohesion also improved. The best results were shown when reeling velocity was 180-220 r.p.m. But when the velocity was increased more than 220 r.p.m., the results of cohesion got worse more or less. D) When the temperature of the drying pipe in reeling machine was raised, the results of cohesion also showed a tendency to improve. 4. Re-reeling A) We could net reach a conclusion as to have correlation between the number of dipping repeat in vacuum tank and the results of cohesion before re-reeling process. B) When we used Seracol 500 as an agglutination protective agent with l/1000 to l/2000 of water, the results of cohesion test were better. C) When we used Pearl-lite as an agglutination protective agent with 1/1000 to 1/2000 of water, the results of cohesion were considerably better. D) We gained tile best results when used Cohesion Improving Chemical, A-80, with 500-1500 times diluted. 1) Results of cohesion was improved when humidity was low or temperature was high in the rereeling machine. 5. Filature water A) The water pH near the isoelectric point of protein showed the best cohesion, but the farther water pH, the worser results were obtained. B) With the increasing of M-alkalinity in filature water, the results of cohesion were worse. Above all, we understood the tendency of the results of cohesion get worse when the M-alkalinity is increased above 200 ppm. C) By increasing the total hardness of the filature water, it improved the results of cohesion. Especially, when the total hardness was above 300ppm, the results were extremely high. 6. Effects combination of each results A) The result of effects combination in filature processes with the obtained best conditions was distinctively improved. But the results could not reach in mathematicaly double effect. When reelied under worse conditions, the results of cohesion test were too bad. There was "effect limit" for the promotion. B) Generally the results of cohesion were bad when the filature conditions(the temperature, pressure and the properties of water, etc) are processed as sericin loss to be high. On the other hand, the results were very good when lower sericin loss was controlled in filature conditions. C) When filature conditions such as reeling velocity and croissieur length provide pysical cohesion ability and when raw silk dry fast during reeling and re-reeling, we found the result of cohesion was better. 7. Correlation of silk testing items. A) A negative correlation exists between the results of cohesion test and cleanness defect. Another word, the result of cohesion test was found to be worse as cleanness defect increased. B) In cleanness, cohesion has negative correlation against the number of slugs, but we could not find any correlation against long loops, loose ends. C) Cohesion has negative correlation against average neatness and low neatness defect. The better the results of neatness respectively, the better the results of cohesion found. D) There is no correlation between tenacity and the results of cohesion test, but there was high positive correlation between the results of elongation and those of cohesion test. The more elongation, the better the results of cohesion was found.

  • PDF

Experimental Study of Heat/Mass Transfer in Rotating Cooling Passages with Discrete Ribs (단락 요철이 설치된 내부 냉각유로에서 회전에 따른 열/물질전달 특성 연구)

  • Kim Kyung Min;Kim Sang In;Lee Dong Ho;Cho Hyung Hee
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.29 no.5 s.236
    • /
    • pp.590-598
    • /
    • 2005
  • The present study has been conducted to investigate the effect of discrete ribs and rotation on heat/mass transfer characteristics in a two-pass square duct with $90^{\circ}-rib$ turbulators. The rib turbulator has a square cross section of 1.5 mm. The rib height-to-hydraulic diameter ratio $({e/D_{h})$ is 0.056, and the rib pitch-to-rib height ratio (p/e) is 10. The gap width is the same as the rib height. The rotation number ranges from 0.0 to 0.2 while Reynolds number is fixed to 10,000. In a stationary duct, the heat/mass transfer on the surfaces with discrete ribs is enhanced because the gap flow promotes local turbulence and flow mixing near the ribbed surface. In a rotating duct, the gap flow affects differently the heat/mass transfer on leading and trailing surfaces with discrete ribs. On the leading surface of the first pass, heat/mass transfer is increased due to the gap flow. On the trailing surface of the first pass, however, heat/mass transfer is decreased because the gap flow disturbs reattachment of main flow. The phenomenon, that is, the difference of heat transfer between the leading and the trailing surfaces is distinctly presented by rotation.

Biochemical and Ultrastructural Trends in Proteolysis of the $\beta$-subunit of 7S Protein in the Cotyledons During Germination of Soybean Seeds

  • Krishnan, Hari B.
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.47 no.2
    • /
    • pp.85-94
    • /
    • 2002
  • Antibodies raised against the purified p-subunit of $\beta$-conglycinin were used in immunohistochemical studies to monitor the pattern of $\beta$-conglycinin mobilization in the cotyledons during soybean [Glycine max (L.) Merr.] seed germination. Western blot analysis revealed that the break down of the $\beta$-subunit of $\beta$-conglycinin commenced as early as 2 days after seed imbibition (DAI). Concurrent with the degradation of the $\beta$-subunit of $\beta$-conglycinin, accumulation of 48, 28, and 26 kD proteolytic intermediates was observed from 2 to 6 DAI. Western blot analysis also revealed that the acidic subunit of glycinin was mobilized earlier than the basic subunit. The basic glycinin subunit was subjected to proteolysis within 2 DAI resulting in the appearance of an intermediate product approximately 2 kD smaller than the native basic glycinin subunit. In contrast to the major seed storage proteins, lipoxygenase was subjected to limited proteolysis and was detected even after 8 DAI. The first sign of $\beta$-conglycinin breakdown was observed near the vascular strands and proceeded from the vascular strands towards the epidermis. Protein A-gold localization studies using thin sections of soybean cotyledons and antibodies raised against the $\beta$-subunit of $\beta$-conglycinin revealed intense labeling over protein bodies. A pronounced decrease in the protein A-gold labeling intensity over protein bodies was observed at later stages of seed germination. The protein bodies, which were converted into a large central vacuole by 8 DAI, contained very little 7S protein as evidenced by sparse protein A-gold labeling in the vacuoles.

Characteristic of Damping Curve for the Directional System of Magnetic Compass (자기컴퍼스 방위지시부의 제진특성)

  • An, Yeong-Hwa;Jeong, Gong-Heun
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.21 no.1
    • /
    • pp.28-34
    • /
    • 1985
  • This paper describes that the characteristic of movement and the performance of the directional system of the liquid magnetic compass analyze and investigate in the kinds of compass and the coefficient of viscosity of the liquid of compass, which the horizontal magnetic field of the geo-magnetic is varied from the equator to the polar region (0.39 gauss-0.03 gauss) by use of apparatus generating artificial magnetic fields. The results are as follows; 1. It is confirmed that the measured values and the calculated values on the characteristic of damping curve by the type of compass and coefficient of viscosity has almost agree with one another. 2. As the horizontal magnetic force geo-magnetic field approaches around the equator (0.39 gauss), the horizontal magnetic field get near the polar region (0.03 gauss), its period is to be longer and the compass card prove not to be more stabilized. 3. The coefficient of viscosity of the liquid in the A, B, C, D and E compasses used in the experiment is estimated 0.03 poises, 0.02 poises, 0.02 poises, 0.015 poises and 0.048 poises respectively by computer simulation.

  • PDF