• 제목/요약/키워드: near target

검색결과 600건 처리시간 0.031초

결합재량 및 다짐에너지에 따른 포러스콘크리트의 특성에 관한 연구 (A Study on the Properties of Porous Concrete according to Volume of Binder and Compaction Energy)

  • 이준;박승범;김정환;서대석;김범규;김형석
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2004년도 추계 학술발표회 제16권2호
    • /
    • pp.513-516
    • /
    • 2004
  • The purpose of this study is to investigate properties of porous concrete according to volume of binder and compaction energy. The result of this study, as compaction energy goes on increasing, the actual measured void ratio is decreased according as a change of compaction energy and volume of binder. The compaction energy has a very near value by target void ratio on the whole when it is $50kN{\cdot}m/m^2,\;50\~75kN{\cdot}m/m^2$ in case of target void ratio is $15\%\;and\;25\%$. As compaction energy goes on increasing, compressive strength of specimens picked up when target void ratio is $20\%\;and\;25\%$. Also, compressive strength of specimens bluntly picked up when compaction energy is over $50\~75kN{\cdot}m/m^2$.

  • PDF

Integrated Guidance and Control Design for the Near Space Interceptor

  • WANG, Fei;LIU, Gang;LIANG, Xiao-Geng
    • International Journal of Aeronautical and Space Sciences
    • /
    • 제16권2호
    • /
    • pp.278-294
    • /
    • 2015
  • Considering the guidance and control problem of the near space interceptor (NSI) during the terminal course, this paper proposes a three-channel independent integrated guidance and control (IGC) scheme based on the backstepping sliding mode and finite time disturbance observer (FTDO). Initially, the three-channel independent IGC model is constructed based on the interceptor-target relative motion and nonlinear dynamic model of the interceptor, in which the channel coupling term and external disturbance are regarded as the total disturbances of the corresponding channel. Then, the FTDO is introduced to estimate the target acceleration and control system loop disturbances, and the feed-forward compensation term based on the estimated values is employed to effectively remove the effect of disturbances in finite time. Subsequently, the IGC algorithm based on the backstepping sliding mode is also given to obtain the virtual control moment. Furthermore, a robust least-squares weighted control allocation (RLSWCA) algorithm is employed to distribute the previous virtual control moment among the corresponding aerodynamic fins and reaction jets, which also takes into account the uncertainty in the control effectiveness matrix. Finally, simulation results show that the proposed IGC method can obtain the small miss distance and smooth interceptor trajectories.

대구지역 공단과 인근 주거지역의 휘발성유기화합물질 오염도 평가 (Evaluation of Volatile Organic Compounds Levels in Industrial Complex and Nearby Residential Areas of Daegu)

  • 조완근;이진우
    • 한국환경과학회지
    • /
    • 제13권6호
    • /
    • pp.519-525
    • /
    • 2004
  • Air pollution from the Daegu industrial complex (Die) in Korea has been a common nuisance and cause of complaints for nearby residents. The current study measured the indoor and outdoor levels of six VOC (benzene, toluene, ethylbenzene, and three isomeric xylenes) at two residential areas with a different proximity to the ODIC, plus the ambient levels at two industrial areas within the boundary of the DDIC. The QA/QC program included the range of correlation coefficient (0.94-0.99) for calibration curves, within the permissible range. Toluene was the most abundant VOC in the ambient air both in residential and industrial areas. Both indoor and outdoor air concentrations of all target VOC except benzene were higher in residential area near the DIC compared to that further away from the DIC. Moreover, the ambient air concentrations of all target VOC except benzene for two industrial sites (A and B) were significantly higher than the outdoor or indoor air concentrations in the two residential areas. The findings further suggested that VOC ambient levels measured in a residential area near the DIC be used as a potential indicator of odor-causing unidentified air pollutants transported from the DIC. Moreover, it was found that the elevated ambient toluene levels outweighed the indoor sources with respect to the environmental exposure of residents nearby the DIC. However, in the residential area further away from the DIC, the toluene indoor sources outweighed the outdoor sources.

전방지역주민(前方地域住民)의 영양(營養) 및 식습관(食習慣) 실태조사(實態調査) (제(第)1보(報)) (Nutrition and Food Habit Survey in a Near by Area of Demilitarized Zone in Korea)

  • 이성동;이정숙;장수경
    • 한국식품영양과학회지
    • /
    • 제12권3호
    • /
    • pp.240-250
    • /
    • 1983
  • This survey was carried out to obtain an information for the improvement of nutrition and the enlightment of dietary life in a near by area of DMZ during the later part of July, 1981. A total of 50 households were selected from Tonghyun-ri, Yunchun-eup, Yunchun, Gyunggi province. As a results of survey, the average intake of vegetable food was as high as 98% and that of the protein intake of good quality was not sufficient. Generally energy and nutrition intake were higher than the recommended dietary allowances and national nutrition survey data of Korean. There were no remarkable clinical symptoms related with nutritional deficiency on the entire target, but were some clinical symptoms related with vitamin deficiency on the children. The housewives lived at target area have a tendency to like the food which they are sued to eat daily and that food was mostly self-supplyed.

  • PDF

Failure analysis of damaged tungsten monoblock components of upper divertor outer target in EAST fusion device

  • Kang Wang;Ya Xi;Xiang Zan;Dahuan Zhu;Laima Luo;Rui Ding;Yucheng Wu
    • Nuclear Engineering and Technology
    • /
    • 제56권6호
    • /
    • pp.2307-2316
    • /
    • 2024
  • A melting failure of W monoblock components of the upper divertor outer target in EAST occurred during the plasma campaigns in 2019. The failure characters and microstructure evolution of the failed W monoblock have been well investigated on one string (W436 string). Near the strike point region where heat flux density is highest, macroscopic cracks and severe surface damage such as dimensional change, melting and solidification are visible in several W monoblocks. At the same time, debonding, melting and migration of Cu/CuCrZr cooling tube components introduced fatal damage to the structure and function. The heat-induced microstructure evolution in the rest part has been examined via hardness tests and metallography. From the heat flux surface to the cooling tube, hardness increased gradually and the recrystallized grains could be found in the region with the highest temperature, while recrystallization grains also appear in some W monoblocks near the cooling tube area. The detailed microstructure has been investigated by metallography and EBSD. Such cases in EAST provide experiences on the extreme condition of accidental loss of coolant or higher discharge power in future devices.

Modeling Study on Dispersion and Scavenging of Traffic Pollutants at the Location Near a Busy Road

  • Ma, Chang-Jin
    • Asian Journal of Atmospheric Environment
    • /
    • 제9권4호
    • /
    • pp.272-279
    • /
    • 2015
  • The information about the dispersion and scavenging of traffic-related pollutants at the locations near busy expressways is very helpful to highway planners for developing better plans to reduce exposures to air pollution for people living as well as children attending schools and child care centers near roadways. The objective of the current study was to give information in the dispersion and scavenging of vehicle-derived pollutants at the region near a busy urban expressway by a combination of two different model calculations. The modified Gaussian dispersion model and the Lagrange type below-cloud scavenging model were applied to evaluate $NO_x$ dispersion and DEP (Diesel exhaust particles) wet removal, respectively. The highest $NO_x$ was marked 53.17 ppb within 20-30 meters from the target urban expressway during the heaviest traffic hours (08:00AM-09:00AM) and it was 2.8 times higher than that of really measured at a nearby ambient measuring station. The calculated DEP concentration in size-resolved raindrops showed a continuous decreasing with increasing raindrop size. Especially, a noticeable decrease was found between 0.2 mm and 1.0 mm raindrop diameter.

근거리 쉐이딩 함수를 이용한 표적 거리 추정 빔형성 기법 (Beamforming Method for Target Range Estimation Using Near Field Shading Function)

  • 최주평;이원철
    • 한국음향학회지
    • /
    • 제27권7호
    • /
    • pp.350-356
    • /
    • 2008
  • 본 논문에서는 근거리 표적 탐지 빔형성 기법에 적합한 체비셰프 (Chebyshev) 및 해닝 (Hanning) 쉐이딩 함수를 제안하였다. 제안된 근거리 표적 탐지용 쉐이딩 함수는 최적의 센서 가중치를 얻기 위하여 비균일 견인 배열의 센서 위치 정보를 사전에 정확히 알고 있다고 가정하였으며, FFT (Fast Fourier Transform)를 통하여 시간영역으로 표현되어 있는 쉐이딩 함수 가중치를 주파수 영역으로 변환시키는 과정을 수행하였다. 이러한 과정을 통하여 산출된 쉐이딩 함수 가중치는 개별 센서에 대한 가중치 값으로 부여하였다. 또한 제안한 근거리 쉐이딩 기법을 기반으로 빔 패턴의 부엽 준위 저하 효과와 더불어 표적에 대한 방위각 및 거리 추정 성능이 향상됨을 모의실험을 통하여 확인하였다. 이와 더불어 수신신호 주파수 대역에 따라 차별적으로 구성된 비균일 견인 배열을 이용함으로 인해 다양한 수신신호 주파수에 따른 성능 감쇄 현상을 최소화하는 배열구조를 제안하였다.

이중 적층 구조 표적을 갖는 투과형 엑스선관의 몬테카를로 전산모사 (Monte Carlo Simulation of Transmission-Type X-ray Tube with Dual-Structured Target)

  • 천권수
    • 한국방사선학회논문지
    • /
    • 제17권1호
    • /
    • pp.107-114
    • /
    • 2023
  • 엑스선형광분석은 비파괴적으로 시료에 포함된 원소와 농도를 분석할 수 있는 기법으로 과학 및 산업 분야에 광범위하게 사용되고 있다. 다양한 물질을 포함한 혼합물 또는 화합물 분석의 정밀도 향상을 위해 10 keV 근방의 저에너지와 20 keV 근방의 에너지 영역에 높은 강도 분포를 갖는 엑스선관이 요구된다. 두 에너지 영역에서 높은 강도 분포를 갖는 스펙트럼을 얻기 위하여 9.65 keV의 특성엑스선을 가지는 텅스텐과 17.48 keV의 몰리브덴 두 물질을 적층한 구조의 표적을 가지는 투과형 엑스선관을 몬테카를로 전산모사를 통해 스펙트럼을 분석하였다. W-Mo 구조의 표적을 통해 10 keV와 20 keV 근방의 강한 강도를 갖는 특성엑스선을 얻었다. 또한 4 ㎛ 두께의 Mo-W multilayers 구조의 표적을 통해 최적의 강도 분포를 갖는 스펙트럼을 얻을 수 있음을 확인하였다. 다양한 표적 물질을 선택 조합하고 두께 최적화를 통해 원하는 에너지 대역에서 높은 강도 분포를 갖는 스펙트럼을 얻는 것이 가능하다.

RF마그네트론 스퍼터 증착장치 개발연구(I) (Study on the Development of RF Magnetron Sputter-Deposition System(I))

  • 김희제;문덕쇠;진윤식;이홍식
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1993년도 하계학술대회 논문집 B
    • /
    • pp.612-614
    • /
    • 1993
  • Sputtering requires a way to bombard the target with sufficient momentum. Positive ions are the most convenient source since their energy and momentum can be controlled by applying a potential to the target. Although many types of discharges have been used for sputtering, magnetrons are now the most widely used because of the high ion current densities. Namely, plasma near the target electrode is confined by magnetic field using permanent magnet, so that the collision probability is increased. It is important to develop RF magnetron sputtering system which has many excellent merits compared with conventional methods. Our study aims to develop 1 kW RF source(13.56 MHz, TR type) and to accumulate the design and construction technology of RF magnetron sputter-deposition system. We developed 1 kW RF sputtering system to deposit thin film. These films are deposited by this RF source matched by auto-matching system using primarily argon gas. Target of Au, Ni, Al, and $SiO_2$ was well deposited on the argon pressure of 5-10 mTorr.

  • PDF

Assessment of Pollution Levels in the Jangsungcheon Watershed Using Load Duration Curves and Analysis of the Causes

  • Cho, Sohyun;Bak, Jonghun;Lee, Yeong Jae;Kim, Kyunghyun;Jung, Kang Young
    • 한국환경과학회지
    • /
    • 제28권10호
    • /
    • pp.873-885
    • /
    • 2019
  • In this study, a load duration curve was applied to the Jangseongcheon, one of the tributaries of the Yeongsan River, to assess whether the target water quality was achieved. In addition, pollution of the water body was investigated to develop and suggest the optimal management time with respect to polluted flow sections and monthly conditions. The average flow rates of sections JS1 and JS2 were $0.25m^3/s$ and $1.08m^3/s$, respectively. The BOD and T-P for water-quality standards at JS1 were rated at II, whereas the COD and TOC were rated at III, thus indicating a fair level of water quality. By contrast, the BOD at JS2 was rated at III, the T-P at IV, and the TOC at V, indicating poor water quality in this section. The load duration curve was plotted using the actual flow data measured in eight-day intervals for eight years from 2011 to 2018 at locations JS1 and JS2 in the Jangsungcheon Basin. In an assessment using the load duration curve on whether the target water quality was met at location JS1, all of the water quality parameters (BOD, COD, TOC, T-N, T-P, and SS) satisfied the target water quality. By contrast, at location JS2, parameters COD, TOC, T-N, and T-P exceeded target values by more than 50%, indicating the target water quality was not met. The discharge loads of locations JS1 and JS2 were analyzed to identify the reasons the target water quality was exceeded. Results revealed that the land system contributed considerably. Furthermore, the discharge load of JS2 accounted for more than 80% of the load on the entire basin, excluding that of JS1. Therefore, the best method for restraining the inflow of pollutants into the stream near location JS2 must be applied to manage the water quality of the Jangsungcheon.