• Title/Summary/Keyword: near infrared spectroscopy (NIR)

Search Result 373, Processing Time 0.029 seconds

A PRELIMINARY STUDY ON THE CHARACTERIZATION OF HONEY BY NEAR INFRARED SPECTROSCOPY

  • Davies, Anthony M.C.;Radovic, Branka;Fearn, Tom;Anklam, Elke
    • Proceedings of the Korean Society of Near Infrared Spectroscopy Conference
    • /
    • 2001.06a
    • /
    • pp.1052-1052
    • /
    • 2001
  • Hear infrared (NIR) spectra were measured, at five temperatures, for forty-eight samples of honey, from a variety of geographical and botanical sources, and the data has been used to explore the possibility of using NIR spectroscopy for testing label claims concerning the geographical and botanical source of honey being offered for sale to the public. These results demonstrate that the successful characterization of the botanical source of a honey may be obtained by NIR spectroscopy. Further work with large numbers of samples and groups will be required to realized this potential. Additional analysis of these data suggest that research into new ways of obtaining information on the change of absorption with temperature might be beneficial for a range of technologies.

  • PDF

Cure Kinetics for the Acid Anhydride-cured Epoxy System Using a Near-infrared Reflection Spectroscopy (근적외선 분광분석을 통한 산무수물경화 에폭시 시스템의 경화 동력학)

  • 곽근호;박수진;이재락
    • Polymer(Korea)
    • /
    • v.24 no.1
    • /
    • pp.65-71
    • /
    • 2000
  • The latent properties and cure kinetics of an acid anhydride-cured epoxy resin have been investigated by a near-infrared (NIR) reflection spectroscopy. The assignments of the latent properties and cure behaviors were performed by the measurements of the NIR reflectance for epoxide and hydroxyl groups at different temperatures. A comprehensive analysis of the origin, location, and shifts during reaction of all major NIR absorption peaks in the spectral range from 4000 to 7100 $cm^{-1}$ / was provided. The extent of reaction was determined from NIR absorption band at the 4530 $cm^{-1}$ / depending on epoxide concentration and cure temperature.

  • PDF

Near Infrared Reflectance Spectroscopy for Non-Invasive Measuring of Internal Quality of Apple Fruit

  • Sohn, Mi-Ryeong;Park, Woo-Churl;Cho, Rae-Kwang
    • Near Infrared Analysis
    • /
    • v.1 no.1
    • /
    • pp.27-30
    • /
    • 2000
  • In this study, we investigated the feasibility of non-destructive determination of internal quality factors of Fuji apple fruit using near infrared(NIR) reflectance spectroscopy and developed the calibration models. As the reference methods, refractometer, titration and texture analyzer for sugar content, acidity and firmness were used, respectively. Samples were scanned from 1100∼2500nm with InfraAlyzer 500C spectrometer and SESAME software was used for data analysis. A multiple linear regression(MLR) analysis was performed to develop the calibrations. The correlation coefficient(R) and standard error of prediction(SEP) were as follows; 0.91, 0.41$^{\circ}$Brix for sugar content, 0.90, 0.04% for acidity and 0.84, 0.094 kg for firmness, respectively. This study shows that NIR spectroscopy can be used to evaluate the sugar content acidity and firmness of apple fruit with acceptable accuracy.

Evaluation of Drainage by Near Infrared Spectroscopy

  • Takamura, Hitoshi;Miyamoto, Hiroko;Mori, Yoshikuni;Matoba, Teruyoshi
    • Proceedings of the Korean Society of Near Infrared Spectroscopy Conference
    • /
    • 2001.06a
    • /
    • pp.1271-1271
    • /
    • 2001
  • Water pollutants in drainage mainly consist of organic compounds. Hence, total organic carbon (TOC), chemical oxygen demand (COD), and biochemical oxygen demand (BOD) were generally used as the indices of pollution. However, these values are determined by special analyzer (TOC), titration method (COD), or microbe culture (BOD). Therefore, the development of simple and easy methods for the determination of water pollution is required. The authors reported the evaluation of water pollution by near infrared (NIR) spectroscopy in a model system with food components (Takamura et al. (200) Near Infrared Spectroscopy: Proceedings of 9th International Conference, pp. 503-507). In this study, the relationship between NIR spectra and drainage was investigated in order to develop a method for evaluation of drainage by NIR. Drainage was obtained in Nara Purification Center. The ranges of TOC, COD, and BOD were 0-130, 0-100 and 0-200, respectively. NIR transmittance spectra were recorded on NIR Systems Model 6250 Research Composition Analyzer in the wavelength range of 680-1235 and 1100-2500 nm with a quartz cell (light path: 0.5, 1, 2, 4 and 10mm) at 10-40. Statistical analysis was performed using NSAS program. A partial least squares (PLS) regression analysis was used for calibration. As the result, a good correlation between the raw NIR spectra and OC was obtained in the calibration. The best light path was 10 and 0.5mm in the wavelength range of 680-1235 and 110-2500nm, respectively. In the calibration, correlation coefficients(R) were 096-0.97 in the both range. In the prediction, however, a good correlation (R=0.89-0.96) was obtained only in the range of 6801235 nm, Similar results were obtained in the cases of COD and BOD. These results suggest the possibility that NIR spectroscopy can be used to evaluate drainage.

  • PDF

Compensation of Variation from Long-Term Spectral Measurement for Non-invasive Blood Glucose in Mouse by Near-Infrared Spectroscopy (근적외분광분석법을 이용한 생쥐꼬리에서의 비침습 혈당 정량시 장기간 측정에 따른 변이 요인의 보정)

  • 백주현;강나루;우영아;김효진
    • YAKHAK HOEJI
    • /
    • v.48 no.3
    • /
    • pp.177-181
    • /
    • 2004
  • Non-invasive blood glucose measurement from mouse tail was performed by near-infrared (NIR) spectroscopy. Three groups; normal, type I diabetes (insulin dependent diabetes mellitus, IDDM), type II diabetes (non-insulin dependent diabetes mellitus, NIDDM) group, were studied over a 10 weeks period with the collection of near-infrared (NIR) spectra. Spectral variations from long-term measurement (10 weeks) from dramatic and nonlinear changes in the optical properties of the live tissue sample were compensated by chemometrics techniques such as principle component analysis (PCA) and partial least squares (PLS) regression. The effect from mouse body temperature changes on NIR spectral data was also considered. This study showed that the compensation of variations from long-term measurement and temperature changes improved calibration accuracy of non-invasive blood glucose measurement.

Quantification of Naproxen in Pharmaceutical Formulation using Near-Infrared Spectrometry (근적외 분광분석법을 이용한 나프록센 정제의 정량분석)

  • Kim Do Hyung;Woo Young Ah;Kim Hyo Jin
    • YAKHAK HOEJI
    • /
    • v.49 no.1
    • /
    • pp.1-5
    • /
    • 2005
  • Near-infrared (NIR) spectroscopy has been widely applied in various field, since it is nondestructive and no sample preparation is required. In this paper, NIR spectroscopy was used for the determination of naproxen in a commercial pharmaceutical preparation. NIR spectroscopy was used to determine the content of naproxen in intact naproxen tablets containing 250 mg ($65.8\%$ nominal concentration) by collecting NIR spectra in the range of $1100{\sim}1750nm$. The laboratory-made samples had $46.1{\sim}85.5\%$ nominal naproxen concentration. The measurements were made by reflection using a fiber-optic probe and calibration was carried out by partial least square regression (PLSR). Model validation was performed by randomly splitting the data set into calibration and validation data set (63 samples as a calibration data set and 42 samples as a validation data set). The developed NIR calibration gave results comparable to the known values of tablets in a laboratorial manufacturing process with standard error of calibration (SEC) and standard error of prediction (SEP) of $1.06\%\;and\;1.04\%$, respectively. The NIR method showed good accuracy and repeatability. NIR spectroscopic determination in intact tablets allowed the potential use of real time monitoring for a running production process.

ANALYTICAL APPLICATIONS OF NEW PORTABLE NEAR INFRARED (NIR) SPECTROMETER SYSTEM

  • Ahn, Jhii-Weon;Kang, Na-Roo;Lim, Hung-Rang;Lee, Jung-Hun;Woo, Young-Ah;Kim, Hyo-Jin
    • Proceedings of the Korean Society of Near Infrared Spectroscopy Conference
    • /
    • 2001.06a
    • /
    • pp.1122-1122
    • /
    • 2001
  • A compact and handhold near infrared (NIR) system using microspectrometer was developed. This system was suitable not only in the laboratory, but also in the field or in the process. This system was first applied for classification of geographical origin of herbal medicine such as ginseng and sesame. To identify the origin of ginseng on site, the portable NIR system is more suitable for real field application. For this study, using the compact NIR system, soft independent modeling of class analogies (SIMCA) with 1100-1750 nm NIR spectra was utilized for classification of geographical origin (Korea and China) of both ginseng and sesame. The accuracy of results is more than 90%. Quantitative analysis for petroleum such as toluene, benzene, tri-methyl benzene, and ethyl benzene was performed with partial least squares (PLS) regression with NIR 1100-1750 nm spectra. This study showed that the NIR method and gas chromatography (GC), which is a standard method, have good correlations. Furthermore, the ash content of Cornu Cervi Parvum was analyzed and the accuracy was confirmed by the developed compact NIR system.

  • PDF

Nondestructive Quantification of Intact Ambroxol Tablet using Near-infrared Spectroscopy (근적외분광분석법을 사용한 암브록솔 정제의 비파괴적 정량분석)

  • 임현량;우영아;김도형;김효진;강신정;최현철;최한곤
    • YAKHAK HOEJI
    • /
    • v.48 no.1
    • /
    • pp.60-64
    • /
    • 2004
  • Near-infrared (NIR) spectroscopy was used to determine rapidly and nondestructively the content of ambroxol in intact ambroxol tablets containing 30 mg (12.5% m/m nominal concentration) by collecting NIR spectra in range 1100-1750 nm. The laboratory-made samples had 10.3∼15.9% m/m nominal ambroxol concentration. The measurements were made by reflection using a fiber-optic probe and calibration was carried out by partial least square regression (PLSR) with autoscaling. Model validation was performed by randomly splitting the data set into calibration and validation data set (7 samples as a calibration data set and 5 samples as a validation data set). The developed NIR method gave results comparable to the known values of tablets in a laboratorial manufacturing Process, standard error of calibration (SEC) and standard error of prediction (SEP) being 0.49% and 0.49% m/m respectively. The method showed good accuracy and repeatability NIR spectroscopic determination in intact tablets allowed the potential use of real time monitoring for a running production process.