• 제목/요약/키워드: natural / forced convection

검색결과 89건 처리시간 0.022초

CFD를 이용한 히트싱크의 열 해석 (Thermal Analysis of Heat Sink Models using CFD simulation)

  • 임송철;이명호;강계명
    • 한국재료학회지
    • /
    • 제15권12호
    • /
    • pp.829-832
    • /
    • 2005
  • Thermal analysis of new designed heat-sink models was carried out according to the natural ana the forced convection using computational fluid dynamics(CFD). Heat resistance of wave type, top vented wave type and plate type of heat sink was compared with each other As the direction of fin and air flow are vertical(z-axis), it is shown that radiant heat performance of all of heat sinks was superior than other experimental conditions. Especially, the heat resistance of top vented wave heat sink was $0.17^{\circ}C/W$(forced convection) and $0.48^{\circ}C/W$(natural convection). The radiant heat performance of heat sink was increased with increasing the height of fin and the width of fin pitch.

BLDC 모터의 온도 및 진동 특성 연구 (Study on Temperature and Vibration of BLDC Motor)

  • 예정우;손문규;최명환;김대화;조연수;이현석;심재술
    • 동력기계공학회지
    • /
    • 제18권4호
    • /
    • pp.43-51
    • /
    • 2014
  • In this paper, transient temperature and vibration characteristics of a brushless DC (BLD(c) motor are studied for external load (165W~495W) and rotational speed (2000 rpm~4000 rpm). For experiment, a simple measurement system is developed to allow a change in load and speed for measuring transient temperature and vibration simultaneously. Temperature and vibration were also measured under the conditions of natural convection and forced convection. Vibrations in the directions of x-axis (#Ch1), y -axis (#Ch2) and z -axis (#Ch3) were obtained by three accelerometers and temperature was obtained by a thermo-couple with respect to time until the motor is steady. Experimental results show that the amplitude of vibration is higher in the order of z-axis (#Ch3), x -axis (#Ch1) and y-axis (#Ch2) and the amplitude of vibration at the forced convection conditions is 10.6% to 17.8% lower than that of vibration at the natural convection. However, the ratio of the vibration value is similar on average regardless of external convection condition.

Flow Visualization and Measurement of Velocity and Temperature in Parallel Plates

  • Piao, R.-L;Bae, D.-S
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제28권2호
    • /
    • pp.277-284
    • /
    • 2004
  • This paper describes the influence of through-flow on the mixed convection in a parallel plates with the upper part is cooled and the lower part heated. When forced convection is imposed on natural convection, it is found that the flow pattern of mixed convection in the parallel plates can be classified into three patterns which were affected by Reynolds number. In such a mixed convection, the flow pattern plays an important role in the heat transfer process. In this study, thermo-sensitive liquid crystal suspension method is employed, then the visualization image acquired through the above method is processed by the color image processing technique and the two-dimensional velocity vector and temperature configuration are measured simultaneously.

튜브의 열전도도와 튜브 외면에서의 대류열전달이 보텍스튜브의 에너지 분리에 미치는 영향 (The Effect of the Thermal Conductivity of a Tube and the Convective Heat Transfer on the Outer Surface of a Tube on the Energy Separation in Vortex Tubes)

  • 유갑중;이병화;최병철
    • 설비공학논문집
    • /
    • 제13권9호
    • /
    • pp.845-852
    • /
    • 2001
  • The phenomena of energy separation in vortex tubes was investigated experimentally to see the effects of the conductivity of a tube and convective heat transfer on the outer surface of a tube. The experiment was carried out with different conductivity (pyrex, stainless steel and copper) of a tube and three kinds of convective heat transfer modes (adiabatic condition, natural convection (air) and forced convection (water) on the outer surface of a tube. the results were obtained that hot exit fluid temperature was highly affected by a change of conductivity of a tube when the outer surface was cooled by the forced convection of water. However, the cold exit temperature was little affected by heat transfer modes on the outer surface in vortex tubes.

  • PDF

보일러용 裸管 및 리브붙이管 의 熱傳達 特性 에 관한 硏究 (A Study on Heat Trasfer Characteristics of Smooth and Ribbed Tubes for Boiler)

  • 김종보;한승탁
    • 대한기계학회논문집
    • /
    • 제9권6호
    • /
    • pp.699-705
    • /
    • 1985
  • 본 논문에서는 자연 및 강제순환 모두를 실험 했으며 사용한 리브붙이 관은 관의 두께와 직경, 리브수, 리브 피치(Pitch), 높이 및 폭등을 사용 하려는 열교환기 나 보일러에 합당하도록 설계, 선정하면, 그 적용 범위는 매우 넓다고 생각돼 연구 검 토 하고자 한다.

감자의 품질특성에 대한 저온스팀 열처리 방식의 효과 (Effects of Soft Steam Treatments on Quality Characteristics of Potatoes)

  • 최찬익;이진희;정명수
    • 한국식품영양학회지
    • /
    • 제25권1호
    • /
    • pp.50-56
    • /
    • 2012
  • This paper examines the effects of various methods of soft steaming(i.e., forced convection-boiler, forced convection-fan, and natural convection) on the quality of potatoes. In particular, the paper investigates the effects of cooking conditions (the steaming method, the treatment time, and the temperature) on the color(L, a, b), moisture content, texture profile, and ascorbic acid of potatoes. The results indicate that not only the cooking method, the treatment time, and the temperature but also the heat transfer mechanism had considerable influence on potato quality. In addition, natural convection steaming was superior to other treatment methods in terms of nutrient retention and texture maintenance. The results of this study should be useful for establishing commercial standards for processing potatoes and improving the quality of thermally processed foods.

Vertical arrangement of coils for efficient cargo tank heating

  • Magazinovic, Gojko
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • 제11권2호
    • /
    • pp.662-670
    • /
    • 2019
  • Tanker cargo tanks are equipped with the means of raising and maintaining the cargo discharge temperature to a suitable level. In this paper, a new heating coil design is proposed and analyzed. Contrary to conventional designs, wherein the heating coils are evenly distributed over the tank bottom, the proposed design arranges the heating coils in the central part of the tank bottom, in a vertical direction. Due to the intensive cargo circulation generated, a forced convection is superimposed on a buoyancy-driven natural convection, providing a more efficient mixed convection heat transfer mechanism. Numerical simulations performed by using a finite volume method show that in the case of 7-bar steam Bunker C heavy fuel oil heating, a five-hour circulation phase average heat transfer coefficient equals 199.2 W/m2K. This result might be taken as an impetus for the more thorough experimental examination.

제너 다이오드를 이용한 공기 유속계측 장치개발

  • 김영재;김희식;조흥근
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1996년도 추계학술대회 논문집
    • /
    • pp.496-500
    • /
    • 1996
  • An air flow measurement device is proposed. The thermal characteristic of a semiconductor element is adopted as a cooling parameter of thermal convection rate. The difference between forced convection and natural convection of two Zener diodes results enough difference in temperature. Experiment at various air flow conditions shows the measuring capability of the air flow in a duct. This measuring device has some merits, such as a reliability n hard field condition, simple circuit for signal processing, small volume of the element, less air flow resistance, independance of various ai temperature. The experimental result shows that it is an exact and usefull air flow measurement device.

  • PDF

격판을 가진 수평환상공간에서의 자연대류 열전달 (Natural Convection Heat Transfer from a Horizontal Annulus with Spacers)

  • 이범철;정한식;권순석
    • 대한기계학회논문집
    • /
    • 제13권1호
    • /
    • pp.153-160
    • /
    • 1989
  • 본 연구는 수평전도관과 수평원통 사이의 환상공간에 수직격판이 부착된 경우와 수평직판이 부착된 경우에 Rayleigh수와 무차원 관열전도율을 변수로하여 수직해석과 Mach-Mehnder 간섭계를 이용한 실험으로 자연대류 열전달특성을 연구 하였다.

팬과 히트 싱크를 이용한 LED 전조등의 냉각성능 해석 (Cooling Performance of LED Head Lamp with Heat Sink and Cooling Fan)

  • 고만석;이주한;오상준;조현석;서태범
    • 대한기계학회논문집B
    • /
    • 제33권12호
    • /
    • pp.947-951
    • /
    • 2009
  • LED has the merits of high reliability, semi-permanent life, rapid-response and its small size for use as light source of head lamp. But the dependence of its performance and life on temperature affect on its practical use. Which dependence makes problem when the LED is heated up to a higher temperature level by self-generation of heat, due to "highly integration" to get enough quantity of light. To solve this problem, effective cooling system is needed that consider conduction, convection and radiation. This study points out the limits of natural convection cooling system and propose of forced convection with heat sink. Also, it describes a correlation between heat sink area and fluid velocity using numerical analysis to optimize the cooling system.