• 제목/요약/키워드: multimodal imaging

검색결과 50건 처리시간 0.032초

수면 분석을 위한 다중 모달 생체신호 측정 시스템 (Multimodal Bio-signal Measurement System for Sleep Analysis)

  • 김상규;유선국
    • 한국멀티미디어학회논문지
    • /
    • 제21권5호
    • /
    • pp.609-616
    • /
    • 2018
  • In this paper, we designed a multimodal bio-signal measurement system to observe changes in the brain nervous system and vascular system during sleep. Changes in the nervous system and the cerebral blood flow system in the brain during sleep induce a unique correlation between the changes in the nervous system and the blood flow system. Therefore, it is necessary to simultaneously observe changes in the brain nervous system and changes in the blood flow system to observe the sleep state. To measure the change of the nervous system, EEG, EOG and EMG signal used for the sleep stage analysis were designed. We designed a system for measuring cerebral blood flow changes using functional near-infrared spectroscopy. Among the various imaging methods to measure blood flow and metabolism, it is easy to measure simultaneously with EEG signal and it can be easily designed for miniaturization of equipment. The sleep stage was analyzed by the measured data, and the change of the cerebral blood flow was confirmed by the change of the sleep stage.

신경교종 등급 분류를 위한 심층신경망 기반 멀티모달 MRI 영상 분석 모델 (Multimodal MRI analysis model based on deep neural network for glioma grading classification)

  • 김종훈;박현진
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2022년도 춘계학술대회
    • /
    • pp.425-427
    • /
    • 2022
  • 신경교종의 등급은 생존과 관련된 중요한 정보로 종양 진행을 평가하고 치료 계획을 세우기 위해 치료 전 신경교종의 등급을 분류하는 것이 중요하다. 신경교종 등급의 분류는 주로 고등급 신경교종과 저등급 신경교종으로 나누는 방식을 주로 사용한다. 본 연구에서는 심층신경망 모델을 활용하여 촬영된 MRI 영상을 분석하기 위해 이미지 전처리 기법을 적용하고 심층신경망 모델의 분류 성능을 평가한다. 가장 높은 성능의 EfficientNet-B6 모델은 5-fold 교차 검증에서 정확도 0.9046, 민감도 0.9570, 특이도 0.7976, AUC 0.8702, F1-Score 0.8152의 결과값을 보여준다.

  • PDF

Sentinel lymph node mapping using tri-modal human serum albumin conjugated with visible dye, near infrared fluorescent dye and radioisotope

  • Kang, Se Hun;Kim, Seo-il;Jung, So-Youn;Lee, Seeyoun;Kim, Seok Won;Kim, Seok-ki
    • 대한방사성의약품학회지
    • /
    • 제1권1호
    • /
    • pp.62-73
    • /
    • 2015
  • We developed an evans blue-indocyanine green-$^{99m}Tc$-human serum albumin conjugate for sentinel lymph node mapping and we describe its unique potential usage for clinical implications. This conjugate has combined the strengths of visible blue dye, near-infrared fluorescence and radioisotope into one single conjugate without any additional weakness/disadvantage. All the components of evans blue-indocyanine green-$^{99m}Tc$-human serum albumin are safe and of low cost, and they have already been clinically used. This conjugate was stable in the serum, it showed a long retention time in the lymphatic system and the lymph nodes showed a much higher signal-to-noise ratio after the conjugate was injected intradermally into the paw of mice. Both the single-photon emission computed tomography and near-infrared fluorescent images of the mice were successfully obtained at the same time as the excised sentinel lymph nodes showed blue color. The visual color, near-infrared fluorescence and gamma ray from this agent could be complementary for each other in all the steps of sentinel lymph node sampling: exploring and planning sentinel lymph node before excision with visualization of the exact sentinel lymph node location during an operation. Therefore, the triple modal agent will possibly be very ideal for sentinel lymph node mapping because of the high signal-to-noise ratio for non-invasive imaging and its complementary multimodal nature, easy preparation and safety. It is promising for clinical applications and it may have great advantages over the traditional single modal methods.

Accuracy of image registration for radiation treatment planning using a brain phantom

  • Jin, Ho-Sang;Suh, Tae-Suk;Song, Ju-Young;Juh, Ra-Hyeong;Kwark, Chul-Eun;Lee, Hyoung-Koo;Choe, Bo-Young
    • 대한자기공명의과학회:학술대회논문집
    • /
    • 대한자기공명의과학회 2002년도 제7차 학술대회 초록집
    • /
    • pp.106-106
    • /
    • 2002
  • Purpose: The purposes of our study are (1) to develop a brain phantom which can be used for multimodal image registration, (2) to evaluate the accuracy of image registration with the home-made phantom. Method: A brain phantom which could be used for image registration technique of CT-MR and CT-SPECT images using chamfer matching was developed. The brain phantom was specially designed to obtain imaging dataset of CT, MR, and SPECT. The phantom had an external frame with 4 N-shaped pipes filled with acryl rods for CT, MR imaging and Pb rods for SPECT imaging. 8 acrylic pipes were inserted into the empty space of the brain phantom to be imaged for geometric evaluation of the matching. Accuracy of image fusion was assessed by the comparison between the center points of the section of N-shaped bars in the external frame and the inserted pipes of the phantom. Technique with partially transparent, mixed images using color on gray was used for visual assessment of the image registration process.

  • PDF

Recent advances in spatially resolved transcriptomics: challenges and opportunities

  • Lee, Jongwon;Yoo, Minsu;Choi, Jungmin
    • BMB Reports
    • /
    • 제55권3호
    • /
    • pp.113-124
    • /
    • 2022
  • Single-cell RNA sequencing (scRNA-seq) has greatly advanced our understanding of cellular heterogeneity by profiling individual cell transcriptomes. However, cell dissociation from the tissue structure causes a loss of spatial information, which hinders the identification of intercellular communication networks and global transcriptional patterns present in the tissue architecture. To overcome this limitation, novel transcriptomic platforms that preserve spatial information have been actively developed. Significant achievements in imaging technologies have enabled in situ targeted transcriptomic profiling in single cells at single-molecule resolution. In addition, technologies based on mRNA capture followed by sequencing have made possible profiling of the genome-wide transcriptome at the 55-100 ㎛ resolution. Unfortunately, neither imaging-based technology nor capture-based method elucidates a complete picture of the spatial transcriptome in a tissue. Therefore, addressing specific biological questions requires balancing experimental throughput and spatial resolution, mandating the efforts to develop computational algorithms that are pivotal to circumvent technology-specific limitations. In this review, we focus on the current state-of-the-art spatially resolved transcriptomic technologies, describe their applications in a variety of biological domains, and explore recent discoveries demonstrating their enormous potential in biomedical research. We further highlight novel integrative computational methodologies with other data modalities that provide a framework to derive biological insight into heterogeneous and complex tissue organization.

How can neurological outcomes be predicted in comatose pediatric patients after out-of-hospital cardiac arrest?

  • Kim, Hyo Jeong
    • Clinical and Experimental Pediatrics
    • /
    • 제63권5호
    • /
    • pp.164-170
    • /
    • 2020
  • The prognosis of patients who are comatose after resuscitation remains uncertain. The accurate prediction of neurological outcome is important for management decisions and counseling. A neurological examination is an important factor for prognostication, but widely used sedatives alter the neurological examination and delay the response recovery. Additional studies including electroencephalography, somatosensory-evoked potentials, brain imaging, and blood biomarkers are useful for evaluating the extent of brain injury. This review aimed to assess the usefulness of and provide practical prognostic strategy for pediatric postresuscitation patients. The principles of prognostication are that the assessment should be delayed until at least 72 hours after cardiac arrest and the assessment should be multimodal. Furthermore, multiple factors including unmeasured confounders in individual patients should be considered when applying the prognostication strategy.

뇌팬톰을 이용한 삼차원 다중영상정합의 정확성 평가 (Accuracy Evaluation of Three-Dimensional Multimodal Image Registration Using a Brain Phantom)

  • 진호상;송주영;주라형;정수교;최보영;이형구;서태석
    • 대한의용생체공학회:의공학회지
    • /
    • 제25권1호
    • /
    • pp.33-41
    • /
    • 2004
  • 다양한 의학 영상장비로부터 획득된 영상들간의 정합의 정확성은 방사선치료계획에서 매우 중요한 쟁점 중의 하나이다. 본 연구에서는 수제작된 뇌팬톰(brain phantom)을 이용한 영상정합의 정확성 평가방법을 연구하였다. 다중영상정합을 위해 CT-MR, CT-SPECT간의 Chamfer 정합(Chamfer matching)법을 적용하였다 영상정합의 정회성은 팬톰 내에 삽입된 표적(target)들의 중심정의 비교를 통하여 평가되었다. CT-MR, CT-SPECT간의 삼차원 제곱근평균제곱(root-mean-square) 이동편차는 각각 2.1$\pm$0.8 mm와 2.8$\pm$1.4 mm이었다. 회전편차는 세 직교좌표축에서 2$^{\circ}$이내였다. 이 오차들은 기존의 팬톰연구와 비교하여 합리적인 오차 허용범위 내에 들었다. 중첩한 CT-MR, CT-SPECT영상의 육안검증 또한 좋은 정합 결과를 보였다.

적외선 체열촬영을 이용한 통증 치료효과의 평가 (Evaluation of the Therapeutic Effects in Pain Management Using Infrared Thermal Imaging)

  • 김민정;이승윤;김성협;임정애;강포순;우남식;이예철
    • The Korean Journal of Pain
    • /
    • 제14권2호
    • /
    • pp.164-170
    • /
    • 2001
  • Background: Infrared Thermal Imaging (ITI) is an effective tool for the diagnosis of disease and evaluation of the therapeutic effects following pain treatment. Patients who were treated for pain in pain clinic described the intensity of pain and the degree of change of their pain using a visual analogue scale (VAS). In this study, the usefulness of ITI following multimodal methods for pain management were compared with the change of VAS. Methods: 1119 patients were evaluated. The patients were treated with stellate ganglion block, epidural block or trigger points injection. Before treatment, the temperature difference (${\Delta}T$) of the involved area and the corresponding area on the opposite side of the body was measured using ITI and VAS was assessed. After treatment, the temperature difference (${\Delta}T$) between the normal and involved areas, the change of ${\Delta}T$ (${\Delta}dT$), VAS and the change of VAS (${\Delta}VAS$) were measured. Statistic correlations between ${\Delta}dT$and ${\Delta}VAS$ were calculated in all groups. Results: Correlation of the ${\Delta}dT$ and ${\Delta}VAS$ was significant by contingency coefficient test. (SGB group, C = 0.358, Epi group, C = 0.377, TPI group, C = 0.374, P < 0.05) Conclusions: ITI is a reliable tool for the assessment of therapeutic effects following multidimensional management of painful disease.

  • PDF

간질에서의 $^{18}F-FDG$ PET의 임상 이용 (Clinical Application of $^{18}F-FDG$ PET in Epilepsy)

  • 김유경
    • Nuclear Medicine and Molecular Imaging
    • /
    • 제42권sup1호
    • /
    • pp.172-176
    • /
    • 2008
  • FDG PET has been used as a diagnostic tool for localization of seizure focus for last 2-3 decades. In this article, the clinical usefulness of FDG PET in the management of patients with epilepsy has been reviewed, which provided the evidences to justify the medicare reimbursement for FDG PET in management of patients with epilepsy. Literature review demonstrated that FDG PET provides an important information in localization of seizure focus and determination whether a patients is a surgical candidate or not. FDG PET has been reported to have high diagnostic performance in localization of seizure focus in neocortical epilepsy as well as temporal lobe epilepsy regardless of the presence of structural lesion on MRI. Particularly, FDG PET can provide the additional information when the results from standard diagnositic modality such as interictal or video-monitored EEG, and MRI are inconclusive or discordant, and make to avoid invasive study. Furthermore, the presence of hypometabolism and extent of metabolic extent has been reported as an important predictor for seizure free outcome. However, studies suggested that more accurate localization and better surgical outcome could be expected with multimodal approach by combination of EEG, MRI, and functional studies using FDG PET or perfusion SPECT rather than using a single diagnostic modality in management of patients with epilepsy. Complementary use of FDG PET in management of epilepsy is worth for good surgical outcome in epilepsy patients.

Feasibility Study of Determining the Healing Phase of Achilles Tendon Rupture in Rats Using Optical Coherence Tomography

  • Kim, Young-Sik;Chae, Yu-Gyeong;Jeon, Min Yong;Kim, Dong Kyu;Ahn, Yeh-Chan
    • Journal of the Optical Society of Korea
    • /
    • 제19권2호
    • /
    • pp.175-181
    • /
    • 2015
  • Optical coherence tomography (OCT) is a noninvasive technique for microscopic investigation of tissue. We thought that the OCT method could be a potential tool for monitoring the healing process of a tendon. In this study we used two rat models, denervated and non-denervated groups, to observe a variety of healing phases of Achilles tendon (AT) injury. We made samples of AT injury lesions, to take OCT images and to make histopathological samples of serial sectional tissue. In an OCT image the denervated rat showed no specific finding, but the non-denervated rat showed a large defect lesion that was scaffolding tissue. OCT findings combined with pathologic findings showed advantages in visualization of tendon microstructure over other imaging modalities such as MRI and US, and OCT is beneficial to making a treatment plan, especially the timing and intensity of rehabilitation. Therefore a multimodal platform using OCT for evaluation of tendon injury may be potentially useful for many applications.