• Title/Summary/Keyword: multi-span greenhouse

Search Result 39, Processing Time 0.026 seconds

An Analysis of Wind Force Coefficient Distributions for Optimum Design of Multi-Span Arched Greenhouses (아치형 연동온실의 최적설계를 위한 풍력계수분포도의 분석)

  • 이현우;이석진
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.38 no.2
    • /
    • pp.145-151
    • /
    • 1996
  • Wind force coefficients of multi-span arched greenhouses with respect to wind direction of $0^{\circ}$ and $30^{\circ}$ were estimated to give more reasonable coefficient. The conventional and subdivided division types of wind force coefficient distribution diagrams were constructed by using the wind tunnel experimental data. Bending moments on the greenhouses were determined through structural analysis using obtained wind force coefficients, and were analyzed. Because actual wind pressure values on a face of greenhouse varied with locations, the more divisions of wind force coefficient distribution were subdivided, the better distribution type was coincided with actual state. In order to calculate the more accurate section force occurred on the arched greenhouse by the wind loads, it was recommendable that the wind force coefficient distribution should take more subdivision type. The maximum bending moment at the multi-span greenhouse frame at wind direction of $30^{\circ}$ was greater than that at O。, therefore the wind force coefficient at inclined wind direction to the wall was needed to be considered for the multi-span greenhouse structural design.

  • PDF

Analysis of Heating Characteristics of Multi-Layered Insulation Curtain with Silica Aerogel in Greenhouses (실리카 에어로겔을 이용한 다겹보온커튼의 온실 난방 특성 분석)

  • Jin, Byung-Ok;Kim, Hyung-Kweon;Ryou, Young-Sun;Lee, Tae-Seok;Kim, Young-Hwa;Oh, Sung-Sik;Kang, Geum-Choon
    • Journal of Bio-Environment Control
    • /
    • v.29 no.4
    • /
    • pp.320-325
    • /
    • 2020
  • This study aimed to analyze thermo-keeping and economic feasibility by utilizing silica aerogel, which has been attracting attention as a new material, complementing the disadvantages of the conventional multi-layered thermal screen, and producing and installing multi-layered thermal screen. The multi-layered thermal screen used in the experiment was produced in two combinations using a non-woven fabric containing silica aerogel and measured and compared the temperature and fuel consumption changes due to differences in practice with the multi-layered thermal screen being sold and used on the market. Experimental results show that the temperature and relative humidity changes due to the differences of the multi-layered thermal screens in the single-span greenhouse and the multi-span greenhouse were small but remained almost the same temperature and relative humidity. It is judged that this shows that the multi-layered thermal screen using silica aerogel is not inferior to the conventional multi-layered thermal screen. As a result of a comparative analysis of heating energy, the aerogel-based multi-layered thermal screen reduced fuel consumption by about 15% in the single-span greenhouse and about 20% in the multi-span greenhouse compared to the conventional multi-layered thermal screen. It is clear that heating energy is saved as a greenhouse size and duration increase. It was found that the silica aerogel-based multi-layered screen was more breathable and warmer than the conventional multi-layered thermal screen, but It was found that the multi-layered screen used in the multi-span greenhouse was heavier and stiff compared with the conventional multi-layered thermal screen, indicating less workability and operability. Therefore, improvements were applied to the multi-layered screens used in the single-span greenhouses. It was confirmed that the replacement of internal insulation materials reduced thickness and improved stiffness so that there could be sufficient possibility for farmers to use.

Evaluation of Natural Ventilation Performance for Multi-span Plastic Greenhouses (다연동 플라스틱 온실의 자연환기성능 평가)

  • Nam, Sang-Woon;Kim, Young-Shik;Seo, Dong-Uk
    • Journal of Bio-Environment Control
    • /
    • v.22 no.1
    • /
    • pp.7-12
    • /
    • 2013
  • Environmental measurements in the many different types of horticultural farms were carried out to evaluate the ventilation performance for multi-span plastic greenhouses according to the eaves height, the number of spans, the existence of side wall vents and the position of roof vents. Hydroponic tomatoes were being cultivated in all experimental greenhouses, and ventilation rates of the greenhouses were analyzed by the heat balance method. It showed that the ventilation rate in the greenhouse with 4 m eaves height increased about 22% compared to the greenhouse with 2 m eaves height. The ventilation rate in the greenhouse with 9 spans decreased about 17% compared to the greenhouse with 5 spans. In the greenhouse with 9 spans, if there were no side wall vents, the ventilation rate showed about a third of the case that side wall vents were open. Overall, as the eaves height was higher and the number of spans was smaller in multi-span greenhouses, the natural ventilation performance was better. And the ventilation performance was best in the greenhouse which the eaves height was high and the position of roof vents was ridge, not gutter. Therefore, in order to maximize the natural ventilation performance, multi-span plastic greenhouses need to improve their structures such as that make the eaves height higher, place the roof vents on the ridge, install the side wall vents as much as possible, and the number of spans is limited to about 10 spans.

Evaluation of Computational Fluid Dynamics for Analysis of Aerodynamics in Naturally Ventilated Multi-span Greenhouse

  • Lee, In Bok;Short, Ted H.;Sase, Sadanori;Lee, Seung Kee
    • Agricultural and Biosystems Engineering
    • /
    • v.1 no.2
    • /
    • pp.73-80
    • /
    • 2000
  • Aerodynamics in a naturally ventilated multi-span greenhouse with plants was analyzed numerically by the computational fluid dynamics (CFD) simulation. To investigate the potential application of CFD techniques to greenhouse design and analysis, the numerical results of the CFD model were compared with the results of a steady-state mass and energy balance numerical model. Assuming the results of the mass and energy balance model as the standard, reasonably good agreement was obtained between the natural ventilation rates computed by the CFD numerical model and the mass and energy balance model. The steady-state CFD model during a sunny day showed negative errors as high as 15% in the morning and comparable positive errors in the afternoon. Such errors assumed to be due to heat storage in the floor, benches, and greenhouse structure. For a west wind of 2.5 m s$^{-1}$ , the internal nonporous shading screens that opened to the east were predicted to have a 15.6% better air exchange rate than opened to the west. It was generally predicted that the presence of nonporous internal shading screens significantly reduced natural ventilation if the horizontal opening of the screen for each span was smaller that the effective roof vent opening.

  • PDF

Field Survey and Structural Safety Analysis of Pipe Framed Greenhouses (파이프 골조 온실의 구조 실태 및 안전성 검토(농업시설))

  • 남상운;김문기;유인호
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 2000.10a
    • /
    • pp.315-320
    • /
    • 2000
  • An investigation and structural safety analysis was conducted to get the basic data for establishing maintenance strategy of pipe framed greenhouses. The number of greenhouses investigated was 108 in total. Most multi-span greenhouses had narrower width and lower height than the standard 1-2W greenhouse, and most of single-span greenhouses were tunnel type. In multi-span greenhouses, the size and interval of frameworks such as rafter, purline, column, and cross beam were mostly suitable, but frameworks of single-span greenhouses were mostly insufficient.

  • PDF

Rotational Stiffness of Connection in Multi-span Vinyl Greenhouse (내재해형 연동 비닐하우스 접합부의 회전강성)

  • Kim, Min-Sun;Choi, Ki-Sun;Shin, Ji-Uk
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.34 no.12
    • /
    • pp.3-10
    • /
    • 2018
  • Recently, severe damage to domestic horticultural structures is frequently observed due to extreme climate effects. To minimize the structures' damage, a study on the structural stability of multi-span vinyl greenhouses is needed. This paper presents to measure the rotational stiffness of different connectors to improve the design capacities of the specification. The paper investigated fourteen types of the different connectors, which was commonly used in the multi-span greenhouses, and three different types of the connectors predicted to be under moment-connection were selected: i) T-clamp, ii) U-clamp, iii) C-clamp. Static loading tests for three different connectors were performed to measure the rotational stiffness. Additionally, the boundary condition for the structural design was proposed based on the experimental results of the rotational stiffness. One of three connectors, C-clamp had larger rotational stiffness than other connectors, and the experimental results presented the three connectors had boundary conditions; i) T-clamp was pinned-connection, ii) U-clamp was semi-rigid connection, iii) C-clamp was semi-rigid connection.

An Experimental Study for Deriving Design Factors of Snow Removal Machines for Multi-span Greenhouse (연동온실 곡부 제설장치의 설계인자 도출을 위한 실험적 연구)

  • Song, Hosung;Kim, Yu Yong;Yun, Nam Kyu;Lim, Seong Yoon
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.57 no.6
    • /
    • pp.131-140
    • /
    • 2015
  • This paper presents overall procedure by experimental study in order to deriving design factors of snow removal machine on roof of multi-span greenhouse. For the purpose of the testing, the scale model of the machine was made in the form to drive above the monorail. The test was performed in order to calculating friction coefficient of the machine and shear coefficient between sliced horizontal section of snow at constant temperature and humidity room in National Academic of Agricultural Science. As a result of the laboratory test, shear coefficient between sliced horizontal section of snow were calculated 1.60~2.37. Further investigation, we will study to derive the relationship between the real and scaled model through the field test.

Comparative Study on Efficiencies of Naturally-Ventilated Multi-Span Greenhouses in Korea (다연동 온실의 자연환기효율성 비교 분석)

  • Kwon, Soon-Hong;Jung, Sung-Won;Kwon, Soon-Gu;Park, Jong-Min;Choi, Won-Sik;Kim, Jong-Soon
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.20 no.1
    • /
    • pp.8-18
    • /
    • 2017
  • This research analyzed the ventilation effect of the multi-span greenhouse based on the types of greenhouse structure, weather conditions, and locations inside the greenhouse. To compare and analyze the ventilation effects with different types of greenhouse, the uniform environmental conditions should be selected in advance. But these factors are not controlled and require tense many precision facilities and labor forces. Thus, the CFD simulation was used for the air stream to be analyzed qualitatively and quantitatively. In addition, for the ventilation effect analysis, the TGD (Tracer Gas Decay) was used to overcome the shortcomings of the current ventilation measurement method. The calculation error of ventilation rate using TGD was low (10.5%). Thus, the TGD is very effective in calculating the ventilation efficiency. The wind direction of 90 degrees showed the best ventilation effect. The ventilation rate also decreased along the air circulation path, and the rate was the lowest around the outlet. The computed fluid method (CFD) turned out to be a power tool for simulating flow behavior in greenhouse.

An Analysis of Optimal Production Scales by Greenhouse Types using Long-run Average Cost in Controlled Tomato (비닐하우스 토마토의 온실유형에 따른 장기평균비용을 고려한 적정 생산규모 분석)

  • Rhee, Zae-Woong;Hong, Na-Kyoung;Kim, Tae-Kyun
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.57 no.5
    • /
    • pp.29-35
    • /
    • 2015
  • The optimal greenhouse scales for controlled tomato should be studied because the increase of oil price and labor costs following the shortage of workforce makes greenhouse cultivation hard to gain profits. The purpose of this study is to estimate optimal production scales by greenhouse types for controlled tomato. The translog cost function is estimated based on the production cost survey data. The results can be summarized as follows: First, the average production cost of controlled tomato per kg decreases as the production scale increases. Second, according to the tomatoes farm of standard farming income data of RDA, the minimum production scale is 23 ton. Third, the estimated output of single-span greenhouse considering production scale with minimum average cost is 345 ton and production cost per kg is 1,476 won. The corresponding figures of multi-span greenhouse are 415 ton and 936 won, respectively. The study results can be used as basic materials for efficient decision making of tomato farmhouses and novice farmers. Also, the study shows that multi-span greenhouse should be encouraged to be built, since it requires lower marginal cost than single greenhouse. The results of this paper will help increase the income of farmhouses and cut expenses for the coming years.

Analysis of the efficiency of natural ventilation in a multi-span greenhouse using CFD simulation (CFD 시뮬레이션을 이용한 연동형 온실 내 자연환기의 효율성 분석)

  • Short, Ted H.
    • Journal of Bio-Environment Control
    • /
    • v.8 no.1
    • /
    • pp.9-18
    • /
    • 1999
  • Natural ventilation in a four and one-half span, double polyethylene commercial greenhouse was investigated with actual data collected at Quailcrest Farm near Wooster, Ohio. Moreover, a computational fluid dynamics (CFD) numerical technique, FLUENT V4.3, was used to predict natural ventilation rates, thermal conditions, and airflow distributions in the greenhouse. The collected climate data showed that the multi-span greenhouse was well ventilated by the natural ventilation system during the typical summer weather conditions. The maximum recorded air temperature difference between inside and outside the greenhouse was 3.5$^{\circ}C$ during the hottest (34.7$^{\circ}C$) recorded sunny day; the air temperatures in the greenhouse were very uniform with the maximum temperature difference between six widely dispersed locations being only 1.7$^{\circ}C$. The CFD models predicted that air exchange rates were as high as 0.9 volume per minute (A.C. .min$^{-1}$ ) with 2.5m.s$^{-1}$ winds from the west as designed.

  • PDF